• 제목/요약/키워드: heat release capacity

검색결과 39건 처리시간 0.019초

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.

콘 칼로리미터의 배기 덕트 내부 유동 특성 기초 실험 (Fundamental Experiment on the Flow Characteristics inside the Exhaust Duct of Cone Calorimeter)

  • 신연제;유우준
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.35-40
    • /
    • 2019
  • 본 연구에서는 콘 칼로리미터의 발열량 산출 값에 대한 신뢰성 평가를 위한 기초 연구로 산소소모지수법의 주요 인자인 질량유량에 관한 측정 불확도 관계식을 분석하였다. 본 연구에서 사용한 콘 칼로리미터의 덕트는 길이가 5 m이고 직경이 0.2 m로 내부가 완전히 빈 공간인 경우와 기공의 직경이 3 mm인 격자망 그리고 기공의 직경 10 mm와 기공률 0.76인 허니컴 형상의 덕트를 각각 제작하였다. 덕트 내부로 유입되는 질량유량을 산출하기 위해서 양방향 차압계와 온도센서를 유동의 수직방향으로 균일한 위치에 4개씩 설치하였으며, 레이놀즈 수 증가에 따른 속도구배와 유동의 섭동을 측정하였다. 그 결과 흡입용량이 증가할수록 난류강도에 비례하여 세 가지 형상 모두 속도구배가 증가하였으며, 95% 신뢰수준에서 질량유량에 대한 확장 불확도의 편차는 완전히 빈 공간, 격자망(dp = 3 mm) 그리고 허니컴(dp = 10 mm, 𝜖 = 0.76) 순으로 낮게 나타났다. 주목할 만한 점으로는 송풍기의 흡입용량이 가장 높은 조건일 때 격자망(dp = 3 mm)이 허니컴(dp = 10 mm, 𝜖 = 0.76) 형상에 비해서 흡입용량의 저항성은 높은데 비해서 질량유량의 확장불확도는 오히려 증가하였으며, 본 연구의 결과는 콘 칼로리미터의 덕트 내부 유동 안정성 향상을 위한 설계 자료의 활용이 가능할 것으로 판단된다.

제트팬 용량이 도로터널 화재에 미치는 영향 (Effect of Re-ventilated Fan Capacity on Road Tunnel Fire)

  • 김강희;조목량;김태권
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.204-210
    • /
    • 2019
  • 터널 내부에서의 화재의 경우 일반도로와 달리 운전자의 시야 확보가 어려워 대형사고가 발생할 가능성이 매우 높다. 따라서 터널 내부 화재 발생 시 제트팬 용량에 따른 제연 효과에 관한 연구가 필요하다. 본 연구에서는 NIST에서 개발한 화재시뮬레이션인 FDS를 사용하여 제트팬의 유무, 제트팬의 용량에 의해 터널 내부에서 발생한 차량 화재에 대한 제트팬 용량에 따른 연기 거동 및 가시거리, 일산화탄소의 농도를 분석하였다. HRRPUA(Heat Release Rate Per Area)는 $3.6MW/m^2$로 설정하였으며, 모든 해석 시간은 총 600s로 설정하였다. CFD에 의한 가시거리, 일산화탄소 농도 해석은 y=30m, y=110m에서 결과를 확인하였으며 직경과 유량에 따라 연기거동 분석, 가시거리 분석, 일산화탄소 농도를 확인하였다. 제트팬의 직경과 유량이 커질수록 y=30m 후방에서 높은 가시거리를 확인할 수 있으며 일산화탄소 농도가 0ppm임을 확인하였다. 제트팬 직경과 유량이 큰 조건에서는 제트팬 유동의 상류 방향으로 대피하면 인명피해를 최대한 줄일 수 있을 것으로 판단된다.

제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구 (Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control)

  • 이재빈;문주현;이성혁;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2011
  • 본 연구에서는 초고층 건축물 화재 시 피난 안전 구역이 있는 피난 층에서 화재실로부터 발생하는 연기의 거동을 파악하기 위하여 상용코드를 사용하여 수치해석을 하였다. 화재를 모사하기 위하여 10 MW의 발열량에 해당하는 온도와 속도를 이용하여 부력 plume을 적용하였으며 종 보존 방정식을 이용하여 화재 연기 거동을 예측하였다. 피난 안전 구역에 제연 댐퍼를 설치하여 급기 가압 제연 시스템을 적용하였으며 화재실 문이 열린 경우 25 $m^3/s$, 화재실과 부속실 문이 동시에 열린 경우 50 $m^3/s$의 제연 댐퍼송풍량은 화재 안전 기준 NFSC 501-A를 만족하며 충분히 제연이 가능하다는 것을 확인하였다. 부속실문이 열린 경우, 화재실의 문이 닫혀 있더라도 문과 벽 사이의 틈새 면적으로 연기가 피난 안전 구역으로 유입될 가능성이 있다. 또한, 50 $m^3/s$ 높은 송풍량으로 제연 중 화재실 문이 닫힐 경우 피난자가 화재실에 고립될 가능성을 확인하였다. 그러므로 피난자의 안전을 위해 제연 송풍량의 조절이 필요하며 본 연구에서는 피난 시나리오에 따른 적절한 송풍량을 제안한다.

Effects of Ginseng Saponins in Energy Metabolism, Memory, and Anti-neurotoxicity

  • Wang Lawrence C.H.;Lee Tze-fun
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 2002년도 학술대회지
    • /
    • pp.55-65
    • /
    • 2002
  • Ginseng has been used as a key constituent in traditional medicine prescriptions for centuries. Other than its well-known anti-stress and adaptogenic properties, ginseng has also been shown to be very effective in treating age-related deterioration in metabolic and memory functions. Although it is generally believed that the saponin (GS) fraction of the ginseng root accounts for the bioactivity of ginseng, a direct demonstration on which ginsenoside does what is still generally lacking. In the past decade, our laboratory has endeavored to identify the active GS components involved in energy metabolism, memory, and anti-neurotoxicity. To examine the ergogenic effects of GS in enhancing aerobic capacity, rats were subjected to either severe cold ($40^{\circ}C$ under helium-oxygen, two hours) or exercise workload $(70\%\;VO_{2}max,$ to exhaustion). Acute systemic injection (i.p.) of ginseng GS (5-20 mg/kg) significantly elevated both the total and maximum heat production in rats and improved their cold tolerance. However, pretreating the animal with the optimal dose (10 mg/kg) of GS devoid of $Rg_1\;and\;Rb_1$ failed to elicit any beneficial effects in improving cold tolerance. This indicates that either $Rb_1\;and/or\;Rg_1$ may be essential in exemplifying the thermogenic effect of GS. Further studies showed that only pretreating the animals with $Rb_1(2.5-5\;mg/kg),\;but\;not\;Rg_l,$ resulted in an increase in thermogenesis and cold tolerance. In contrast to the acute effect of GS on cold tolerance, enhancement of exercise performance in rats was only observed after chronic treatment (4 days). Further, we were able to demonstrate that both $Rb_1\;and\;Rg_1$ are effective in enhancing aerobic endurance by exercise. To illustrate the beneficial effects of GS in learning and memory, a passive avoidance paradigm (shock prod) was used. Our results indicated that the scopolamineinduced amnesia can be significantly reversed by chronically treating (4 days) the rats with either $Rb_1\;or\;Rg_1$ (1.25 - 2.5 mg/kg). To further examine its underlying mechanisms, the effects of various GS on ${\beta}-amyloid-modulated$ acetylcholine (ACh) release from the hippocampal slices were examined. It was found that inclusion of $Rb_1$ (0.1 ${\mu}M$), but not $Rg_1$, can attenuate ${\beta}-amyloid-suppressed$ ACh release from the hippocampal slices. Our results demonstrated that $Rb_1\;and\;Rg_1$ are the key components involved in various beneficial effects of GS but they may elicit their effects through different mechanisms.

  • PDF

계면중합법에 의한 파라핀왁스의 마이크로캡슐화에 있어서 SDS 첨가량이 미치는 영향 (Effects of the SDS Dosage on the Paraffin Wax Micro-Capsulation by the Interfacial Polymerization)

  • 신세순;정재윤;김영호;임명관;최동욱
    • 한국건설순환자원학회논문집
    • /
    • 제7권1호
    • /
    • pp.60-68
    • /
    • 2012
  • 이 연구에서는 건물의 사용에 있어서 잠열의 축열 성능을 이용하여 에너지를 절감할 수 있는 축열 건자재로서 멜라민 수지를 콘크리트 벽체 물질로 하는 파라핀 왁스의 마이크로 캡슐화를 통한 축열미립자의 제조에 관하여 연구하였다. 마이크로 캡슐화 공정에 있어서 계면활성제로서 SDS의 첨가량이 미치는 영향을 검토하였으며 제조된 축열미립자의 축열 성질을 비교하였다. SDS가 첨가됨에 따라서 마이크로캡슐화가 가능하였으며 첨가량이 증가함에 따라서 보다 단단한 캡슐이 형성되었다. 또한 적정 첨가량에서는 매우 균일한 재료가 형성되었다. 또한 SDS 첨가량은 제조된 축열 미립자의 축열 성질에도 영향을 크게 미쳤으며 첨가량이 증가할수록 왁스의 융점 온도에서 열 저장 및 방출 현상이 뚜렷히 관찰되었다. 이 연구는 건물의 사용 에너지 절감을 위해 마이크로 캡슐화된 PCM을 콘크리트 벽체에 적용하는 연구 시리즈의 일부이다.

  • PDF

고준위폐기물처분장의 완충재 개념 도출: 접근방안 (Establishing the Concept of Buffer for a High-level Radioactive Waste Repository: An Approach)

  • 이재완;이민수;최희주
    • 방사성폐기물학회지
    • /
    • 제13권4호
    • /
    • pp.283-293
    • /
    • 2015
  • 고준위폐기물처분장에서 완충재는 공학적방벽의 주요 구성요소 중 하나이다. 본 연구에서는 국 내외의 완충재 요구사항과 성능기준을 분석하고, 우리나라 고준위폐기물처분장에 적합한 완충재 개념 도출을 위한 접근방안을 제시하였다. 완충재의 주요 성능기준 인자항목으로, 수리전도도, 핵종 저지능, 팽윤압, 열전도도, 역학적 특성치(mechanical properties), 유기물함량(organic carbon content), 일라이트화 속도(illitization rate) 등을 고려하였다. 우리나라 고준위폐기물처분장 완충재 물질로서 국산 벤토나이트(Ca-벤토나이트)와 대안재로 MX-80 벤토나이트(Na-벤토나이트)를 제안하였다. 완충재의 기술사양은 Ca-벤토나이트 경우엔 우리나라의 성능기준을, Na-벤토나이트의 경우는 스웨덴의 성능기준을 보수적으로 만족하는 값으로 설정하였다. 완충재의 두께는 전단거동, 핵종 유출, 열전도의 측면에서 평가하여 결정하였으며, 평가결과 완충재의 두께는 0.25 ~ 0.5 m 사이가 적절하였다. 그러나 최종적인 완충재의 두께는 향후 보다 심도 있는 열-수리-역학적 평가와 경제적, 공학적 측면을 고려하여 결정하여야 할 것이다.

고준위폐기물처분장 공학적방벽의 갭 공간이 미치는 영향 분석 (An Influence Analysis on the Gap Space of an Engineered Barrier for an HLW Repository)

  • 윤석;이창수;김민준
    • 한국지반공학회논문집
    • /
    • 제37권4호
    • /
    • pp.19-26
    • /
    • 2021
  • 원자력발전소에서 발생되는 고준위폐기물은 지하 수백 미터 깊이의 암반에 처분된다. 이러한 고준위폐기물은 인체에 유해하기에 공학적방벽시스템에 의해 안전하게 처분되어야 하며, 공학적방벽시스템은 처분용기, 뒤채움재, 완충재 등으로 구성된다. 고준위폐기물처분장에 이러한 공학적방벽시스템의 구성요소를 설치하게 되면, 처분용기 및 완충재 사이, 완충재와 자연 암반 사이 등에 갭이 존재하게 된다. 이러한 갭의 존재로 인해 공학적방벽재의 차수능과 열전달 효율이 떨어질 수 있기에, 갭 공간의 크기 및 갭채움재 특성 평가 등의 연구가 반드시 필요하다고 할 수 있다. 해외에 비해 국내 처분시스템을 고려한 갭 공간 및 갭채움재에 대한 연구는 아직 진행되고 있지 않는 상황이기에, 본 연구에서는 수치해석을 통해 국내 처분시스템을 고려한 갭 공간이 공기로 채워져 있는 조건하에서 갭의 크기에 따른 벤토나이트 완충재의 첨두 온도를 도출하였다. 처분용기와 완충재 사이의 갭 공간이 완충재의 첨두 온도에 미치는 영향은 미미하였으나, 완충재와 자연 암반 사이의 갭 공간에 따른 완충재의 첨두 온도는 최고 약 40%의 차이를 나타냈다.

RAW 264.7 대식세포에서 환원형 glutathione인 luthione의 면역 증강 활성 평가 (Evaluation of Immune Enhancing Activity of Luthione, a Reduced Glutathione, in RAW 264.7 Macrophages)

  • 지선영;권다혜;황혜진;최영현
    • 생명과학회지
    • /
    • 제33권5호
    • /
    • pp.397-405
    • /
    • 2023
  • 항산화제로서 산화적 손상의 방지에 중요한 역할을 하는 것으로 알려진 glutathione (GSH)의 면역 조절에 대한 연구는 현재까지 제대로 이루어지지 않았다. 본 연구에서 우리는 환원형 GSH인 luthione®이 RAW 264.7 세포에서 면역 강화 효과가 있는지를 조사하였다. 유세포 분석 및 면역 형광 실험의 결과에 의하면, luthione은 대조군 세포에 비해 대식세포의 대표적인 기능인 식세포 활성을 luthione 처리 농도 의적으로 증가시키는 것으로 나타났다. 또한, cytokine array의 결과에 의하면, IL-5, IL-1β와 IL-27의 발현이 luthione이 처리된 세포에서 유의하게 증가하였다. 아울러 luthione에 의한 TNF-α 및 IL-1β의 생성 증가는 그들의 단백질 발현 증가를 통해 이루어졌으며, NO 및 PGE2와 같은 면역 매개체 유리의 증가는 iNOS 및 COX-2의 발현 증가와 관련이 있었으며, 이는 M1 대식세포 분화 마커인 CD86 발현의 증가와 연관성이 있었다. 그리고 heatmap 분석을 통하여 SOCS1/3 매개 STAT/JAK 신호 전달 경로가 luthione에 의한 면역 조절 증가에 관여함을 확인하였다. 결론적으로, 우리의 결과는 luthione이 M1 macrophage polarization의 분자 조절자로 작용하여 면역 능력을 향상시킬 수 있음을 시사한다.