• 제목/요약/키워드: heat pump system

검색결과 1,120건 처리시간 0.029초

겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석 (Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter)

  • 정성일;성내리;김두현;이재근;황유진;박종훈;서석장
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.402-408
    • /
    • 2009
  • In this paper, the effects of ventilation and humidification on thermal comfort and indoor air quality(IAQ) were evaluated in a classroom when a heat pump system was operated in winter. Thermal comfort parameters, such as temperature, relative humidity, globe temperature and air velocity, were measured at 9 points in the classroom. The concentration of $CO_2$ and total suspended particles(TSP) in the classroom were measured in order to analyze IAQ. Temperature distribution in the classroom was decreased by $2{\sim}5^{\circ}C$ when the ventilation system and the humidifier were operated. When the relative humidity was adjusted to 60% by operating the humidifier and the ventilation system, the predicted mean vote(PMV) in the classroom was within the comfortable range of $-0.5{\sim}0.5$. When the ventilation system was operated, the average concentration of $CO_2$ and TSP were decreased by 645 ppm and 0.17 $mg/m^3$, respectively. This paper suggests the humidification and ventilation conditions to maintain the comfortable environment in the school classroom in winter experimentally.

지열 냉방시스템을 이용한 분만돈사의 냉방효과 분석 (Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House)

  • 최희철;송준익;나재천;김민지;방한태;강환구;박성복;채현석;서옥석;유영선;김태원;박재홍
    • 한국축산시설환경학회지
    • /
    • 제16권2호
    • /
    • pp.99-108
    • /
    • 2010
  • 지열냉방시스템을 분만돈사에 적용하여 냉방효과 및 분만돈과 자돈의 생산성을 조사하였다. 처리구는 지열냉방돈사와 관행돈사로 2개로 나누였으며, 돈사당 각각 모돈 48두씩를 수용하여 하절기 4주간 시험을 실시하였다. 시험결과, 외부기온이 $33.0^{\circ}C$ 이상으로 더운 날에는 냉방을 위한 지하수 순환량이 많이 소요되어 최고기온과 지하수 순환량이 아주 밀접한 정의 상관관계가 있는 것으로 나타났다. 지열냉방 돈사의 온 습도 변화의 경우 최고기온은 관행돈사에 비하여 낮게 유지되고, 최저기온도 많이 떨어지지 않아 일교차가 훨씬 적었다. 미세먼지 입자가 상대적으로 큰 PM 10은 지열냉방돈사가 관행돈사에 비하여 최고 61.4% (111.1 vs 42.9) 까지 감소되었다. 그러나 작은 입자의 분진은 오히려 지열 냉방구에서 약간 높은 경향이었다. 암모니아가스 배출량의 경우 지열냉방돈사는 관행돈사에 비하여 유의하게 (p<0.05) 감소하였다. 총 3회에 걸쳐 측정된 임신돈의 호흡수는 지열냉방돈사에서 유의적으로 (p<0.05) 감소하였고, 에피네프린과 노르에피네프린 호르몬의 경우에 지열냉방돈사에서 감소하는 경향을 보였다. 이유시 체중은 지열 냉방돈사가 관행돈사에 비하여 유의적으로 (p<0.05) 증가하였으며, 여름철 모돈의 사료 섭취량은 관행돈사에서 유의적으로(p<0.05) 감소하였다. 따라서 지열냉방시스템은 여름철 분만사의 온 습도를 낮게 유지시킬 수 있을 뿐만 아니라 분진, 암모니아 가스 발생량 빛 모돈의 호흡수 감소에 영향을 주어 모돈과 포유자돈의 생산성을 개선시킬 수 있다.

버즈 두바이 콘크리트 건물의 설계와 시공 (Design and Construction of the Burj Dubai Concrete Building Project)

  • Abdelrazaq, Ahmad
    • 콘크리트학회지
    • /
    • 제20권6호
    • /
    • pp.28-35
    • /
    • 2008
  • 700미터 이상의 높이와 160층 이상으로 설계된 버즈두바이가 완공되면 버즈두바이는 인간이 건축한 건축물 중에서 최고높이의 건축물이 될 것이다. 바람의 동적효과를 완화하고 제어시키는 것이 가장 중요한 설계요소중의 하나이며, 설계초기의 공기역학적 형상과 풍공학에 대한 고려가 이러한 주상복합건물의 건축적 형상 및 디자인에 있어 큰 역할을 하는 반면, 건물의 구조시스템을 위한 재료 선택 또한 디자인의 중요한 요소이고 그 다음으로 세부적인 재료기술에 대한 평가 및 기술자 수급이 요구되어진다. 콘크리트는 콘크리트의 강도, 강성, 감쇠, 잉여력, 형틀성, 내화성, 시공성, 원가 등을 고려하여 선정된다. 이 논문은 콘크리트를 활용한 구조시스템을 적용하면서의 설계적으로 도전되었던 부분과 버즈두바이의 콘크리트공사의 초기계획에 대해 집중적으로 다룰 것이다.

Establishment of the Measurement System of the Magnetic Field for the Study on the Magnetic Field Tolerance of TMP

  • Baik, Kyungmin;Cheung, Wan-Sup;Lim, Jong-Yeon;Choi, Kyoung-Min;Nam, Seung-Hwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.106.1-106.1
    • /
    • 2013
  • When strong static magnetic field is applied to the TMP, it is expected that the presence of the magnetic field might retard the velocity of the blades which results in the change of the pumping speed of the TMP. However, such effect of the magnetic field on the TMP has not been well characterized. Thus, under the strong magnetic field, monitoring pumping speed as well as generated heat, pressure, and vibration of the TMP may be an important issue to understand the magnetic field tolerance of the TMP and the development of magnetic shielding technique for the key components of the pump. For this purpose, magnetic field generation system to the vertical direction by a circular current source was firstly designed and suggested [K. Baik et al., 44th Annual Conf. KVS, 22(1), 153, (2012)]. In the current study, another magnetic field generation systems are presented to apply the magnetic field to the horizontal and radial directions by the rectangular current sources and the permanent magnets respectively. Such systems were made to generate at least 50 Gauss of magnetic field along the vertical direction and at least 25 Gauss of magnetic field along the horizontal or radial direction. Current study introduces the evaluation system of the magnetic field along the vertical, horizontal, and radial directions and presents the measured experimental results of the magnetic field when such systems are combined with the equipment where TMP will be installed.

  • PDF

Conceptual design of small modular reactor driven by natural circulation and study of design characteristics using CFD & RELAP5 code

  • Kim, Mun Soo;Jeong, Yong Hoon
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2743-2759
    • /
    • 2020
  • A detailed computational fluid dynamics (CFD) simulation analysis model was developed using ANSYS CFX 16.1 and analyzed to simulate the basic design and internal flow characteristics of a 180 MW small modular reactor (SMR) with a natural circulation flow system. To analyze the natural circulation phenomena without a pump for the initial flow generation inside the reactor, the flow characteristics were evaluated for each output assuming various initial powers relative to the critical condition. The eddy phenomenon and the flow imbalance phenomenon at each output were confirmed, and a flow leveling structure under the core was proposed for an optimization of the internal natural circulation flow. In the steady-state analysis, the temperature distribution and heat transfer speed at each position considering an increase in the output power of the core were calculated, and the conceptual design of the SMR had a sufficient thermal margin (31.4 K). A transient model with the output ranging from 0% to 100% was analyzed, and the obtained values were close to the Thot and Tcold temperature difference value estimated in the conceptual design of the SMR. The K-factor was calculated from the flow analysis data of the CFX model and applied to an analysis model in RELAP5/MOD3.3, the optimal analysis system code for nuclear power plants. The CFX analysis results and RELAP analysis results were evaluated in terms of the internal flow characteristics per core output. The two codes, which model the same nuclear power plant, have different flow analysis schemes but can be used complementarily. In particular, it will be useful to carry out detailed studies of the timing of the steam generator intervention when an SMR is activated. The thermal and hydraulic characteristics of the models that applied porous media to the core & steam generators and the models that embodied the entire detail shape were compared and analyzed. Although there were differences in the ability to analyze detailed flow characteristics at some low powers, it was confirmed that there was no significant difference in the thermal hydraulic characteristics' analysis of the SMR system's conceptual design.

수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침 (Design Guidlines of Geothermal Heat Pump System Using Standing Column Well)

  • 한정상;한혁상;한찬;김형수;전재수
    • 자원환경지질
    • /
    • 제39권5호
    • /
    • pp.607-613
    • /
    • 2006
  • 내 수문지열계 가운데 수주지열정(SCW)시스템을 합리적으로 설치이용할 수 있는 조건들은 심도별 지온증가율이 명확하고($2^{\circ}C/100m$심도), 기존의 지하수 열펌프가 필요로 하는 순환수의 유량에 비해 최소 $10{\sim}30%$의 중온의 심부지하수가 산출될 수 있어야 하며, 순환수를 공내로 재주입시 공내붕괴가 일어나지 않는 견고한 암석들이 존재 하여야 한다. 수주지열정의 1개공당 굴착심도는 평균 $400{\sim}500m$이며, 이로 부터 개발가능한 지열에너지는 공당 약 $30{\sim}40RT$ 규모인데 비해 1개 수직지중열교환기가 공급가능한 지열에너지는 $2{\sim}3RT$ 정도이다. 즉 수주지열정 1개공은 $10{\sim}15$개의 수직지중열교환기 역할을 한다. 따라서 이 방식은 수직루프 설치장소의 공간 문제를 해소할 수 있는 유일한 대안으로 인식되어, 현재 전국 각지에서 많은 수의 SCW들이 무분별 하게 비과학적으로 설치되고 있다. 이와 같이 해당지역 수문지열계의 수리 지질학적인 특성과 열적인 특성을 명확히 파악하지 않은 상태에서 수주지열정을 설계 시공하는 경우에 나타날 문제점들은 추후 합리적인 천부지열 개발 이용에 지대한 장애요인이 될 것이다. 따라서 본고는 국내 수문지열계에 적합한 수주지열정을 설계 하는데 있어 필요한 일종의 지침서를 제시하기 위해 작성되었다.

일사영향권내 비균질 토양의 열적거동 예측 모델 (Model to Predict Non-Homogeneous Soil Temperature Variation Influenced by Solar Irradiation)

  • 김용환;현명택;강은철;박용정;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.1-7
    • /
    • 2006
  • This study is to develop a model to predict the soil temperature variation in Korea Institute of Energy Research using its thermal properties, such as thermal conductivity and diffusivity. Soil depth temperature variation is very important in the design of a proper Ground Source Heat Pump (GSHP) system. This is because the size of the borehole depends on the soil temperature distribution, and this can decrease GSHP system cost. If the thermal diffusivity and thermal conductivity are known, the soil temperature can be predicted by either the Krarti equation or the Spitler equation. Then a comparison with the Krarti equation and Spitler equation data with the real measured data can be performed. Also, the thermal properties can be reasonably approximated by performing a fit of the Krarti and Spitler equations with measured temperature data. This was done and, as a result, the Krarti equation and Spitler equation predicted values very close to the measured data. Although there is about a $0.5^{\circ}C$ difference between the deep subsurface prediction (16m - 60m), with this equation, were expected to have model this Non-Homogeneous Soil Temperature phenomenon properly. So, it has been shown that a prediction of non-homogeneous soil temperature variation influenced by solar radiation can be achieved with a model.

가스냉방 보급효과에 대한 연구 (Study on The Supplying effect of Gas Air Conditioning Systems)

  • 한정옥;채정민;최경식;홍성호
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.19-25
    • /
    • 2011
  • 냉방용 에너지는 크게 전력과 가스로 대별할 수 있는데, 전기냉방 시스템은 하절기 최대전력을 상승시키는 요인이 되고 있다. 전기에너지는 수요 공급 특성상 저장이 불가능하기 때문에 예상되는 최대전력을 상회하는 공급능력을 보유해야 하며 매년 하절기의 사회문제로 대두되어 왔다. 한편 가스냉방의 경우 흡수식 시스템과 GHP 시스템이 있다. 그러나 가스냉방 보급용량은 전기 냉방에 비해 매우 적으며 소형시장은 대부분 전기냉방에 의존하고 있는 상황이다. 본 논문에서는 국내 냉방에너지 현황을 살펴보고 에너지원간의 부하분담 비중을 분석하여 냉방에너지의 합리적인 방향을 제시하고자 2024년까지 장기적인 가스냉방 보급 규모를 전망하였으며, 이를 바탕으로 가스냉방 보급효과를 분석하여 가스냉방의 확대 필요성을 뒷받침 하고자 하였다.

2-Propanol/Acetone/Hydrogen 반응계로 구성된 화학적 열펌프 시스템의 모사 연구 (A Study on the Simulation of Chemical Heat Pump System Based on 2-Propanol /Acetone/Hydrogen System)

  • 김범재;여영구;정연수;송형근
    • 한국시뮬레이션학회논문지
    • /
    • 제5권1호
    • /
    • pp.43-50
    • /
    • 1996
  • 2-propanol /acetone/hydrogen 반응계로 구성된 화학적 열펌프 시스템은 낮은 온도(82.5~$90^{\circ}C$)에서의 2-propanol의 탈수소화 반응과 높은 온도(약 $200^{\circ}C$ 부근)에서의 acetone 의 수소화반응을 이용하여 열을 고품위화 시키는 장치이다. 본 연구에서는 이 시스템의 해석 및 설계를 목적으로 이 시스템에 대한 수치적인 모델들을 세우고 Sequential modular approach를 이용하여 시스템의 모사를 수행하였다. 또한 에너지 효율을 최대화하기 위하여 열펌프 시스템에서의 환류비의 영향을 규명하였다. 모사결과 이 시스템의 scale up을 위한 정량적인 정상상태 운전조건들을 구할수 있었으며 두 반응의 반응 전화율이 다르더라도 반응물의 유량의 차이를 통하여 두 반응열이 거의 같아지는 것을 알수 있었다. 아울러 주어진 운전조건에서 증류의 환류비는 최소환류비 근처의 최적값이 존재함을 알수 있었다.

  • PDF

방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구 (The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building)

  • 김배영;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.