• 제목/요약/키워드: heat production rate

검색결과 430건 처리시간 0.028초

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

Characteristics Analysis of the Heat Exchange Rate according to Soil Temperature and Grout Material using Numerical Simulation

  • Oh, Jin Hwan;Nam, Yu Jin
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.29-36
    • /
    • 2014
  • The ground source heat pump (GSHP) system has attracted much of attention, because of its stability of heat production and the high efficiency of the system. Performance of the heat exchanger is dependent on the soil temperature, the ground thermal conductivity, the operation schedule, the pipe placement and the design temperature. However, in spite of the many variables of these systems, there have been few research on the effect of the systems on system performance. In this study, analysis of the heat exchange rate according to soil temperature and grout material was conducted by numerical simulation. Furthermore, the heat distribution around the ground heat exchanger was presented on the different conditions of grout and underground temperature by the simulation.

마이크로 적층기술을 이용한 열교환기 생산모델 개발과 경제성 평가 (Development of Heat Exchanger Production Model Based on the Microlamination Technology and Estimation of its Economic Efficiency)

  • 유범상;김재희;박상민
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.97-103
    • /
    • 2006
  • The development of a heat exchanger production model based on the microlamination technology and it's economic efficiency is addressed. A microchannel production model is proposed for the high-volume production. The microlamination system is made up of lamina patterning, laminae sorting and laminae bonding. A cost estimation model is developed based on the hewn cycle time and capital equipment costs. An economic efficiency analysis is performed to determine the cost drivers under the different market and product scenarios. The result of the economic efficiency analysis indicated that the device size and the production rate have a great effect on the overall manufacturing cost of microlamination devices. And it can be concluded that the microlamination should focus on bonding larger laminae and reducing both cycle time and warpage.

연소 변수가 수증기-메탄 개질기의 특성에 미치는 영향 (The Effects of Combustion Parameters on the Characteristics of a Steam-Methane Reformer)

  • 이재성;김호영
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.29-31
    • /
    • 2012
  • The effects of combustion parameters on the characteristics of a steam-methane reformer. The reformer system was numerically simulated using a simplified two-dimensional axisymmetric model domain with an appropriate user-defined function. The fuel ratio, defined as the ratio of methane flow rate in the combustor to that in the reactor, was varied from 20 to 80%. The equivalence ratio was changed from 0.5 to 1.0. The results indicated that as the fuel ratio increased, the production rates of hydrogen and carbon monoxide increased, although their rates of increase diminished. In fact, at the highest heat supply rates, hydrogen production was actually slightly decreased. Simulations showed that equivalence ratio of 0.7 yielded the highest steam-methane mixture temperature despite a 43% higher air flow rate than the stoichiometric flow rate. This means that the production of hydrogen and carbon monoxide can be increased by adjusting the equivalence ratio, especially when the heat supply is insufficient.

  • PDF

천연가스 개질 방식 중소형 고순도 수소제조 장치 개발 연구 (Study on the development of small-scale hydrogen production unit using steam reforming of natural gas)

  • 서동주;주국택;정운호;박상호;윤왕래
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.720-722
    • /
    • 2009
  • This work is mainly focused at developing the hydrogen production unit with the capacity of 20 $Nm^3/h$ of high purity hydrogen. At present steam reforming of natural gas is the preferable method to produce hydrogen at the point of production cost. The developed hydrogen production unit composed of natural gas reformer and pressure swing adsorption system. To improve the thermal efficiency of steam reforming reactor, the internal heat recuperating structure was adopted. The heat contained in reformed gas which comes out of the catalytic beds recovered by reaction feed stream. These features of design reduce the fuel consumption into burner and the heat duty of external heat exchangers, such as feed pre-heater and steam generator. The production rate of natural gas reformer was 41.7 $Nm^3/h$ as a dryreformate basis. The composition of PSA feed gas was $H_2$ 78.26%, $CO_2$ 18.49%, CO 1.43% and $CH_4$ 1.85%. The integrated production unit can produce 21.1 $Nm^3/h$ of high-purity hydrogen (99.997%). The hydrogen production efficiency of the developed unit was more than 58% as an LHV basis.

  • PDF

RENAL REGULATION OF UREA EXCRETION DURING UREA INFUSION IN ACUTE HEAT EXPOSED BUFFALOES

  • Chaiyabutr, N.;Buranakarl, C.;Loypetjra, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권1호
    • /
    • pp.81-90
    • /
    • 1992
  • Five buffaloes kept in normal ambient temperature ($30^{\circ}C$) showed no significant changes in the heart rate, respiratory rate, packed cell volume, plasma constituents and renal hemodymics during intravenous infusion of urea for 4 h. The rate of urine flow, fractional urea excretion, urinary potassium excretion and osmolar clearance significantly decreased while the renal urea reabsorption markedly increased during urea infusion. The decrease of fractional potassium excretion was concomitant with the reduction of the rate of urine flow and urine pH. In animals exposed to heat ($40^{\circ}C$) the rectal temperature heart rate and respiratory rate significantly increased while no significant changes in GFR and ERPF were observed. An intravenous infusion of urea in heat exposed animals caused the reduction of the rate of urine flow with no changes in renal urea reabsorption, urine pH and fractional electrolyte excretions. During heat exposure, there were marked increases in concentrations of total plasma protein and plasma creatinine whereas plasma inorganic phosphorus concentration significantly decreased. It is concluded that an increase in renal urea reabsorption during urea infusion in buffaloes kept in normal ambient temperature depends on the rate of urine flow which affect by an osmotic diuretic effect of electrolytes. The limitation of renal urea reabsorption in heat stressed animals would be attributed to an increases in either plasma pool size of nitrogenous substance or body metabolism.

BODY HEAT CONTENT, HEAT PRODUCTION AND RESPIRATION IN SHEEP EXPOSED TO INTERMITTENT COLD

  • Lee, S.R.;Sasaki, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제7권3호
    • /
    • pp.357-362
    • /
    • 1994
  • Five adult sheep were exposed to intermittent cold for 12 h (18:00-06:00) at an air temperature of $5{\pm}1^{\circ}C$ followed by 12 h (06:00-18:00) at $25{\pm}2^{\circ}C$ over a period of 8 days continuously. Carotid artery blood (Tc), mean skin (Ts) and mean body (Tb = 0.86 Tc + 0.14 Ts) temperatures, heat production rate (HP), respiratory evaporative heat loss, respiration rate (RR) and volume were measured before and after exposure. Tc during the 12 h cold period of intermittent cold exposure was similar to that during the corresponding period in the warm environment, while Tc in the $25^{\circ}C$ of intermittent cold was higher (p < 0.05) than that in the corresponding period in the warm environment. Ts during the cold period markedly decreased (p < 0.001) by about $9^{\circ}C$ when compared with that in the corresponding time period in the warm environment, while Ts during the $25^{\circ}C$ period of intermittent cold recovered to a similar level to that in the warm environment. Tb was lower (p < 0.001) during the cold period of intermittent cold, whereas a slight increase in Tb during the $25^{\circ}C$ period of intermittent cold was significant (p < 0.05) when compared with the value during the similar period in the warm environment. HP was greatly increased (p < 0.001) by cold exposure, followed by an immediate decrease during the first one hour of the 12 h warm period, reaching a similar level to that in the warm environment. A lower (p < 0.05) RR was observed during both the cold and $25^{\circ}C$ period of intermittent cold than during the corresponding periods in the warm environment. The results of the present investigation clearly show that the body temperature of sheep increased during a 12 h warm period following 12 h of exposure to cold. These results suggest that during a warm period of an intermittent cold exposure cycle, heat could be shored in the animal body.

습공기사이클 냉동시스템의 성능해석 (Performance Analysis of a Wet Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

조사연구-콘칼로리메타를 이용한 화재시험에 대하여

  • 이두형
    • 방재기술
    • /
    • 통권19호
    • /
    • pp.22-28
    • /
    • 1995
  • The rate of heat release is probably the single most important measure of fire hazard. Several tech-niques were developed for the measurement of rate of heat release, but were not suitable for fire test-ing purpose. Recently the application of oxygen consumption principle made it possible to development of well-characterized heat release rate measurement apparatus, the furniture calorimeter for large-scale fire tests and the cone calorimeter for bench-scale fire tests. The cone calorimeter can be used to determine the ignitability as well as heat release rate and smoke development, mass loss rate, combustion gas production etc. from burning materials. Thus, test method using cone calorimeter, an internationally recognized and accepted for the evalua-tion of fire properties, is a very promising tool for combustion study on various kind of materials and products.

  • PDF

Heat Production and Thermoregulatory Responses of Sheep Fed Different Roughage Proportion Diets and Intake Levels When Exposed to a High Ambient Temperature

  • Sudarman, A.;Ito, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권5호
    • /
    • pp.625-629
    • /
    • 2000
  • Six yearling Suffolk ewes were used to study the effect of different roughage proportion diets (30%=LR, and 70%=HR) and intake levels (0.7 M and 1.3 M) on heat production and thermoregulatory responses in sheep exposed to different ambient temperatures (20 and $30^{\circ}C$). Sheep fed HR had higher heat production (HP) and time spent eating (TSE) and lower time spent standing (TSS) than those fed LR. But effect of roughage proportion on vaginal temperature (Tv) was obvious only at high intake and at $30^{\circ}C$. Sheep fed high intake had higher Tv, HP, TSS, and TSE than those fed low intake. Roughage proportion and intake level did not have an effect on respiration rate (RR), but ambient temperature did. Ambient temperature did not have an effect on HP, TSS and TSE. At $30^{\circ}C$ sheep had higher Tv and RR than those at $20^{\circ}C$. There were interactions between intake level and ambient temperature in TSS, between intake level and roughage proportion in TSE, and between roughage proportion and ambient temperature in HP. Results indicate that high roughage diet imposes a greater potential heat load on animals than low roughage diet when given at high ambient temperature, but not at low ambient temperature. And the effects is more pronounced at high intake.