• Title/Summary/Keyword: heat index

Search Result 855, Processing Time 0.021 seconds

A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers (서버 컴퓨터의 발열량이 변화한 경우의 데이터센터 내의 기류 및 온도분포 특성에 대한 연구)

  • Chang, Hyun-Jae;Kim, Je-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.3
    • /
    • pp.108-114
    • /
    • 2014
  • On a large scale of data center, heat generation rates from sever computers occupy almost the entire cooling load of the building, and it is gradually increasing. The efficiency of air distribution system in data centers can be affected by heat generation rates of server computers. In this study, the distributions of airflow and temperature in a data center have been investigated by CFD simulations under various conditions of heat generation rates for server computers. From the results, air around the cold aisle which has high temperature flows tremendously into the cold aisle according to the increase of heat generation rates for server computers and the air temperature in the cold aisle becomes higher. The SHI (supply heat index) and RHI (return temperature index) show almost similar values to the cases study because the air inflow rates to server computers increase with the heat generation rates of server computers.

Comparison of Temperature Indexes for the Impact Assessment of Heat Stress on Heat-Related Mortality

  • Kim, Young-Min;Kim, So-Yeon;Cheong, Hae-Kwan;Kim, Eun-Hye
    • Environmental Analysis Health and Toxicology
    • /
    • v.26
    • /
    • pp.9.1-9.9
    • /
    • 2011
  • Objectives: In order to evaluate which temperature index is the best predictor for the health impact assessment of heat stress in Korea, several indexes were compared. Methods: We adopted temperature, perceived temperature (PT), and apparent temperature (AT), as a heat stress index, and changes in the risk of death for Seoul and Daegu were estimated with $^1{\circ}C$ increases in those temperature indexes using generalized additive model (GAM) adjusted for the non-temperature related factors: time trends, seasonality, and air pollution. The estimated excess mortality and Akaike's Information Criterion (AIC) due to the increased temperature indexes for the $75^{th}$ percentile in the summers from 2001 to 2008 were compared and analyzed to define the best predictor. Results: For Seoul, all-cause mortality presented the highest percent increase (2.99% [95% CI, 2.43 to 3.54%]) in maximum temperature while AIC showed the lowest value when the all-cause daily death counts were fitted with the maximum PT for the $75^{th}$ percentile of summer. For Daegu, all-cause mortality presented the greatest percent increase (3.52% [95% CI, 2.23 to 4.80%]) in minimum temperature and AIC showed the lowest value in maximum temperature. No lag effect was found in the association between temperature and mortality for Seoul, whereas for Daegu one-day lag effect was noted. Conclusions: There was no one temperature measure that was superior to the others in summer. To adopt an appropriate temperature index, regional meteorological characteristics and the disease status of population should be considered.

Experimental Study on Combustion Instability Mechanism in a Lean Premixed Model Gas Turbine Combustor using OH Chemiluminescence Images (희박 예혼합 모형 가스터빈 연소기의 OH 자발광을 이용한 연소불안정성에 대한 실험적 연구)

  • Lee Jae Ho;Lee Jong Ho;Chang Young June;Jeon Chung Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.259-264
    • /
    • 2005
  • Measurements of heat release are very important for controling combustion instabilities, which are closely connected with combustion instabilities. $OH^{\ast}$ images were acquired through a ICCD in this study, which were in use as indicating index of the reacting region, global and local heat release rate in the lean premixed combustion. The objectives of this study are to see the effect of equivalence ratio on global heat release rate and local Rayleigh index distribution. The local Rayleigh index distribution was acquired by information from central section of flame. This information was from the line-of-sight images which were inverted by the Abel de-convolution. In each condition, the mean value of heat release increased exponentially with equivalence for a periodic time. Local Rayleigh index distribution cleary showed the region of amplifying or damping the combustion instability as the equivalence ratio increased. This could provide an insight on the region of combustion instability and the structure of flames on the equivalence ratio.

  • PDF

Studies on the Preparation of Processed Aconiti Tubers (무독부자(無毒附子)의 제조에 관한 연구)

  • Park, Shin-Young;Chung, Bo-Sup;Lee, Hyeong-Kyu;Lee, Hyun-Sun;Ryu, Jong-Hyeon
    • Korean Journal of Pharmacognosy
    • /
    • v.20 no.1
    • /
    • pp.25-31
    • /
    • 1989
  • In order to establish the standard method for the preparation of processed Aconiti Tuber, Aconiti Tubers were processed under various conditions and the amount and the composition of alkaloids were determined by HPLC. The ratio of sum of benzoylhypaconine and benzoylmesaconine over the sum of acinitine, mesaconitine, benzoylmesaconine and benzoylhypaconine was used as a detoxification index ((BM+BH)${\times}$100/MA+AC+BM+BH). The adequate value of index was obtained from Japanese 'ka-gong bu-ja' which has been used in Japan. The processing procedure was largely devided into two categories. First is heat treating at $120^{\circ}$ and 1. 2 lbs for 60 min. Second is treatment with various kinds of alkaline solutions followed by heat treatment at $120^{\circ}$ and 1. 2 lbs for 60 min. Among the source of processed Aconiti Tubers, dried bu-ja and yom bu-ja, dried bu-ja was more adequate than yom bu-ja because yom bu-ja has the lower value of index than dried bu-ja and lost active components through the desalting periods. Dried bu-ja whish was treated with alkaline solutions followed by heat treatment has the detoxification index, 50% and dried bu-ja which was treated only with hear has 71. 8%. Compared to the value of index of Japanese 'ka-gong bu-ja', 72%, the dried bu-ja treated with heat at $120^{\circ}$ and 1, 2 lbs for 60min was the most adequate. The $LD_{50}$ value of the processed bu-ja was higher than 15 g crude drugs/kg, p.o. in mice.

  • PDF

Numerical Analysis on the Performance Improvement of Plate Heat Exchanger by Applying to CuO Nanofluid (CuO 나노유체를 적용한 판형열교환기 성능에 대한 수치해석적 연구)

  • Ham, Jeonggyun;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • In this study, a numerical study was conducted to evaluate the performance improvement when CuO nanofluid was used in the plate heat exchanger. As a result, the heat transfer amount is increased by 5.45% when 2 vol% CuO nanofluid is used. The influence on the CuO nanofluid on the performance of heat exchanger is decreased by increasing the flow rate of working fluid. In addition, the overall heat transfer coefficient using 2 vol% CuO nanofluid decreased compared to the base fluid. However, the pressure drop and the consumption of the pump power is increased as the concentration of CuO nanofluid increased because the increase of the viscosity. These are increased up to 15.4% compared to those of the base fluid. Moreover, the performance index of CuO nanofluid is decreased by 12.6% compared to that of the base fluid.

Evaluation of Thermal Environments during the Heat Waves of Summer 2013 in Busan Metropolitan Area (2013년 부산지역 폭염사례일의 열쾌적성 평가)

  • Kim, Young-Jun;Kim, Hyunsu;Kim, Yoo-Keun;Kim, Jin-Kuk;Kim, Yeon-Mai
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1929-1941
    • /
    • 2014
  • Now a days, frequency of abnormally high temperatures like heat wave by global warming and climate change is increasing constantly and the number of patient with heat related illness are jumping rapidly. In this study, we chose the case day for the heat wave in Busan area(Busan and Yangsan), 2013 which it was the most hottest year during 21th century. And then, we analysed the weather condition using automatic synoptic observing system(ASOS) data. Also, four indices, heat index(HI), wet bulb globe temperature(WBGT), Man-ENvironment heat EXchange model(MENEX)'s results like Physiological subjective temperature(PST), Physiological strain(PhS), were calculated to evaluate the thermal comfort and stress quantitatively. However, thermal comfort was different as the each station and thermal comfort index during same time. Busan's thermal indices (HI: hot, WBGT: sweltering, PST: very hot, PhS: very hot) indicated relatively higher than Yansan's (HI: very hot, WBGT: sweltering, PST: very hot, PhS: sweltering). It shows that Busan near coast is relatively more comfortable than Yangsan located in inland.

Effects of Warm-up Performance on SI Engine with Exhaust Heat Recovery System (배기열 회수장치 적용에 따른 SI 엔진의 웜업 성능에 미치는 영향)

  • Park, Kyoun-Suk;Suh, Ho-Cheol;Park, Sun-Hong;Kim, In-Tae;Jang, Sung-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.53-60
    • /
    • 2011
  • The effect of exhaust heat recovery system can be evaluated by two well known method. First method is to measure the time duration from engine start under cold coolant temperature till coolant get warmed. By this methodology coolant warming duration can be index of warm-up effect. Second method is to analyze heat balance of the engine during warm-up phase under steady engine operation so that wasted energy by losses such as cooling and exhaust can be index of warm-up effect. This study focused on evaluation of warming-up effect by both methodology above mentioned using 2L SI engine under from idle to 2000rpm steady condition. Results, idle operation showed low heat recovery efficiency but under higher engine speed condition, remarkable heat recovery efficiency improvement was observed. In 2000rpm steady condition, warm-up duration of engine is decreased by exhaust heat recovery system.

Correlation Analysis Between the Variation of Net Surface Heat Flux Around the East Asian Seas and the Air T emperature and Precipitation Over the Korean Peninsula (동아시아 해역의 표층 순열속 변동과 한반도 기온 및 강수량 변동의 상관성 분석)

  • Lee, Seok-Joon;Chang, You-Soon
    • Ocean and Polar Research
    • /
    • v.43 no.1
    • /
    • pp.15-30
    • /
    • 2021
  • In this study, using 16 ORA-IP (Ocean Reanalysis Intercomparison Project) data, we investigated spatial and temporal changes of net surface heat flux in the East Asian seas and presented a new ensemble net surface heat flux index. The ensemble net surface heat flux index is produced considering the data distribution and the standard deviation of each ORA-IP. From the correlation analysis with air temperature averaged over the Korean Peninsula, ensemble net heat flux around the Korea Strait shows the highest correlation (0.731) with a 3 month time lag. For the correlation study regarding precipitation over the Korean Peninsula, it also shows significant correlation especially in winter and spring seasons. Similar results are also found in comparison with climate indices (AO, PDO, and NINO3.4), but ensemble net surface heat flux data in winter season reveals the strongest correlation patterns especially with winter temperature and spring precipitation.

Effects of Sterilizing Methods on the Content of Index .Constituents of Herbal Medicines (품질 보증을 위한 멸균법이 수종 생약의 지표성분 함량에 미치는 영향)

  • Jeong, Choon-Sik;Cho, So-Yean;Lee, Yong-Soo
    • YAKHAK HOEJI
    • /
    • v.50 no.6
    • /
    • pp.415-420
    • /
    • 2006
  • The purpose of this study was to develop the best methods to sterilize herbal medicines which is frequently used and known to have high susceptibility to microbial contamination. We used dry heat, gamma irradiation and alcohol gas treatment for sterilization, and evaluated these methods in terms of the followings; i) the efficacy of sterilization, and ii) the chemical alteration of index constituents of herbal medicines. Treatment with dry heat effectively eliminated the contaminated microorganisms, and did not significantly alter the content of berberine chloride, paeoniflorin and amygdalin in Phellodendron Bark, Peony Root and Apricot Kernel, respectively: However it seriously changed the color and morphology which are essential criteria to estimate a measure of quality of herbal medicines. Treatment with gamma irradiation showed a strong sterilizing effect, and no alteration of the content of index constituents, color and morphology: Alcohol gas treatment resulted in similar effects as those in gamma irradiation. Collectively; these results suggest that treatment with gamma irradiation or alcohol gas may be useful methods for sterilizing herbal medicines without a decrease in their microbial quality.

Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change (기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구)

  • Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.