Numerical Investigation on Soot Primary Particle Size Using Time Resolved Laser Induced Incandescence (TIRE-LII) (시분해 레이저 유도 백열법을 이용한 매연 입자 크기에 관한 수치적 연구)

  • Lee, Jong-Ho;Kim, Jeong-Yong;Jeong, Dong-Soo;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1022-1031
    • /
    • 2005
  • Temporal behavior of the laser induced incandescence (LII) signal is often used for soot particle sizing, which is possible because the cooling behavior of a laser heated particle is dependent on the particle size. In present study, LII signals of soot particles are modeled using two non-linear coupled differential equations deduced from the energy- and mass-balance of the process. The objective of this study is to obtain an appropriate calibration curve for determining primary particle size by comparing the gated signal ratio and double-exponential curve fitting methods. Not only the effects of laser fluence and gas temperature on the cooling behavior but also heat transfer mechanisms of heated soot particle have been investigated. The second-order exponential curve fitting showed better agreements with the LII signals than the gated signal ratio method which was based on the lust-order exponential curve fit. And the temporal decay rate of the LII signal and primary particle size showed nearly linear relationship, which was little dependent on the laser fluence. And it also could be reconfirmed that vaporization was dominant process of heat loss during first loons after laser pulse, then heat conduction played most important role while thermal radiation had little influence all the time.

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Effect of heat stress on growth performance and blood profiles in finishing pigs

  • Kim, Byeonghyeon;Kim, Hye Ran;Kim, Ki Hyun;Kim, Minji;Baek, Youl-Chang;Lee, Sung Dae;Jeong, Jin Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.683-691
    • /
    • 2020
  • A biomarker is needed to monitor and manage the health of pigs from heat stress (HS). Therefore, we investigated the effects of HS on growth performance, nutrient digestibility, and blood profiles in finishing pigs. A total of 12 finishing pigs (n = 12) were raised in thermal neutral (TN; 25℃) conditions for a 3-d adaptation period. After the adaption, 6 pigs were exposed to HS at 33℃ (HS33) for 5 d. The pigs were fed the same diet based on corn and soybean meal. Chromic oxide was added to all the diets at a level of 2 g·kg-1 as an indigestible marker for the determination of the apparent total track digestibility (ATTD) of nutrients and amino acids. Blood samples were collected after the adaptation and heat treatment to verify the blood profiles. The HS33 pigs had a lower (p < 0.01) average daily feed intake (ADFI) and higher (p < 0.05) rectal temperature compared to the TN pigs. However, there was no difference in the ATTD of nutrients and amino acids. The HS33 pigs had reduced (p < 0.05) levels of serum glucose, non-esterified fatty acids (NEFA), total protein, albumin, and calcium compared to the TN pigs. However, the level of total bilirubin was increased (p < 0.05) in the HS pigs. In conclusion, HS reduced the feed intake and had an adverse effect on health. Altered blood profiles as a result of a negative energy balance are expected to be biomarkers of HS in finishing pigs.

Optimal Analysis of Irreversible Carnot Cycle Based on Entransy Dissipation (엔트랜시 소산에 기반한 비가역 카르노 사이클의 최적 해석)

  • Kim, Kyoung Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • The concept of entransy has been proposed recently as a potential heat transfer mechanism and could be useful in analyzing and optimizing the heat-work conversion systems. This work presents an entransy analysis for the irreversible Carnot cycle by systematic balance formulations of the entransy loss, work entransy, and entransy dissipations, which are consistent with exergy balances. Additionally, several forms of system efficiency are introduced based on entransy for the appreciation of the optimal system performance. The effects of the source temperature and irreversible efficiencies on the optimal conditions for system efficiencies are systematically investigated for both dumping and non-dumping cases of used source fluid. The results show different trends in entransy efficiencies when compared to the conventional efficiencies of energy and exergy, and represent another method to assess the effective use of heat source in power generation systems.

Theoretical approach on the heating and cooling system design for an effective operation of Li-ion batteries for electric vehicles (전기구동 자동차용 리튬이온 배터리의 고효율 운전을 위한 냉방 및 난방 시스템 설계에 대한 이론적 접근법)

  • Kim, Dae-Wan;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2545-2552
    • /
    • 2014
  • This study is aiming to suggest the effective thermal management system design technologies for the high voltage and capacity battery system of the electricity driven vehicles and introduce the theoretical designing methods. In order to investigate the effective operation of the battery system for the electricity driven vehicles, the heat generation model for Li-ion battery system using the chemical reaction while charging and discharging was suggested and the thermal loads of the heat sources (air or liquid) for cooling and heating were calculated using energy balance. Especially, the design methods for the cooling and heating of the battery system for maintaining the optimum operation temperature were investigated under heating, cooling and generated heat (during charging and discharging) conditions. The battery thermal management system for the effective battery operation of the electricity driven vehicles was suggested reasonably depending on the variation of the season and operation conditions. In addition, at the same conditions under summer season, the cooling method using the liquid and active cooling technique showed a relatively high capacity, while cooling method using the passive cooling technique showed a relatively low capacity.

Changes in milk production and blood metabolism of lactating dairy cows fed Saccharomyces cerevisiae culture fluid under heat stress

  • Lim, Dong-Hyun;Han, Man-Hye;Ki, Kwang-Seok;Kim, Tae-Il;Park, Sung-Min;Kim, Dong-Hyeon;Kim, Younghoon
    • Journal of Animal Science and Technology
    • /
    • v.63 no.6
    • /
    • pp.1433-1442
    • /
    • 2021
  • In this study, Saccharomyces cerevisiae culture fluid (SCCF) has been added to a diet of lactating dairy cows to attempt to improve the ruminal fermentation and potentially increase the dry matter intake (DMI) and milk yield. This study was conducted to investigate the effects of SCCF on the milk yield and blood biochemistry in lactating cows during the summer. Twenty-four Holstein dairy cows were randomly assigned to one of four treatments: (1) total mixed ration (TMR-1) (Control); (2) TMR-1 supplemented with SCCF (T1); (3) TMR-2 (containing alfalfa hay) (T2); and (4) TMR-2 supplemented with SCCF (T3). SCCF (5 ml/head, 2.0×107 CFU/mL) was mixed with TMRs daily before feeding to dairy cows. The mean daily temperature-humidity index (THI) during this trial was 76.92 ± 0.51 on average and ranged from 73.04 to 81.19. For particle size distribution, TMR-2 had a lower >19 mm fraction and a higher 8-9 mm fraction than TMR-1 (p < 0.05). The type of TMR did not influence the DMI, body weight (BW), milk yield and composition, or blood metabolites. The milk yield and composition were not affected by the SCCF supplementation, but somatic cell counts were reduced by feeding SCCF (p < 0.05). Feeding SCCF significantly increased the DMI but did not affect the milk yield of dairy cows. The NEFA concentration was slightly decreased compared to that in the control and T2 groups without SCCF. Feeding a yeast culture of S. cerevisiae may improve the feed intake, milk quality and energy balance of dairy cows under heat stress.

Computer Program Development for D$_2$O Upgrader Performance Management (중수승급기 성능관리 프로그램 개발)

  • Ahn, Do-Hee;Kim, Kwang-Rag;Chung, Hong-Suck;Kim, Yong-Eak;Jeong, Ill-Seok;Hon, Sung-Yull;Ko, Jae-Wook
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 1990
  • Heavy water is used as a moderator and a coolant in the pressurized heavy water reactor Because of the high cost of heavy water, downgraded heavy water generated in the reactor system is recycled to the reactor after being concentrated up to 99.8% or more in heavy water upgraders. This study investigates the process of upgraders and then suggests a theoretical model. The relations between process variables are derived from tower packing characteristics, vapour-liquid equilibria, and mass-heat balance equations at a steady state operation of the upgrader h computer program UPGR is developed, using the algorithm that solves the nonlinear equations step by step. It shows that the results of computer simulation are in good agreement with the operating data of the Wolsung upgrader. Thus, this computer code offers the optimum operating guide and is now applied to manage the performance of upgraders for the effective operation of the heavy water upgraders.

  • PDF

A Numerical Study on the Efficiency of an Industrial Furnace for Oxygen Combustion Conditions (산소부화용 공업로의 운전조건이 열효율에 미치는 영향)

  • Kim, Kang-Min;Lee, Yeon-Kyung;Ahn, Seok-Gi;Kim, Gyu-Bo;Yoo, In;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.82-88
    • /
    • 2015
  • After a reheating furnace installation, the modification of the size and the heat capacity is very difficult. Therefore, the development of design package tool is required for the computation on the correct specifications before the design and the installation. Prior to development of the design tool, a module that calculates the amount of heat loss of each part according to the specifications for determining the thermal efficiency of a continuous heating furnace was developed and applied to the oxy-fuel industrial furnace. Through this, the effects of fuel type, oxygen fraction and recirculation on the efficiency of the furnace of which the output is 110Ton/hour were analyzed. In oxy-fuel combustion condition, the efficiency was 15% higher than air combustion conditions. With the using COG(Coke Oven Gas) instead of LNG, the efficiency was slightly increased. In the air combustion condition, the efficiency was increased about 33% with the preheated air. But, in oxy-fuel condition, the amount of exhaust gas was reduced, so the efficiency was increased about 7%.

Estimation of Surface Fluxes Using Noah LSM and Assessment of the Applicability in Korean Peninsula (Noah LSM을 이용한 지표 플럭스 산정 및 한반도에서의 적용성 검토)

  • Jang, Ehsun;Moon, Heewon;Hwang, Seok Hwan;Choi, Minha
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.509-518
    • /
    • 2013
  • Understanding of the exchange between the water and energy which is happening between the surface and atmosphere is the basic of studying water resources. To study these, lots of researches using Noah Land Surface Model(LSM) are in progress. Noah LSM is based on energy and water balance equation and simulates various hydrological factors. There are diverse researches with Noah LSM are ongoing in overseas, on the other hand not enough study has been done. Especially there is almost no study using uncoupled Noah LSM in Korea. In this study we used data from Korea Flux Tower in Haenam(HFK) and Gwangneung(GDK) as forcing data to simulate the model and compared its result of net radiation, sensible heat flux and latent heat flux with the observation data to assess the applicability of Noah LSM in Korea. Regression coefficients of the comparison results of Noah LSM and observation show good agreement with the value of 0.83~0.99 at Haenam and 0.64~0.99 at Gwangneung which means Noah LSM can be trusted.

Validation of Net Radiation Measured from Fluxtower Based on Eddy Covariance Method: Case Study in Seolmacheon and Cheongmicheon Watersheds (에디공분산 방법 기반의 플럭스 타워 순 복사에너지 검증: 설마천, 청미천 유역)

  • Byun, Kyuhyun;Shin, Jiyae;Lee, Yeon-Kil;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • The necessity of clear understanding of water and energy cycles has been attracted recently due to the climate change. The micrometeorological flux tower networks play a role of cornerstone of the hydrological and ecological analyses. Although the eddy covariance techniques used for flux tower have been proven to be applicable for estimation of latent heat flux, the raw data are often underestimated and needs to be corrected. Among several methods, the Bowen ratio is recognized as the most useful method in which the net radiation and other flux data (Ground heat flux, Sensible heat flux) are used and needed to be validated. In this study, in order to validate the net radiation from flux tower in Seolmacheon and Cheongmicheon watersheds, we compare it with two version of calculated net radiation: (1) FAO 56 Daily net radiation proposed by Allen et al. (1998). (2) Instantaneous net radiation proposed by Bastiaanssen (1995). The results showed that the net radiation from the flux data had similar tendency with those calculated based on physical theory. In addition, after it was applied to Bowen ratio method, the corrected latent heat flux was considerably improved with making the energy balance much more closed.