• Title/Summary/Keyword: heart valve repair

Search Result 150, Processing Time 0.022 seconds

Tricuspid Valve Re-Repair in Ebstein Anomaly Using the Cone Technique

  • Kim, Do Jung;Suh, Jee Won;Shin, Yu Rim;Shin, Hong Ju;Park, Han Ki
    • Journal of Chest Surgery
    • /
    • v.49 no.1
    • /
    • pp.35-38
    • /
    • 2016
  • The management of recurrent tricuspid regurgitation after tricuspid valve repair in patients with Ebstein anomaly is difficult, and tricuspid valve replacement is most commonly performed in such patients. We report two cases of recurrent tricuspid regurgitation in patients with Ebstein anomaly that were successfully re-repaired using the cone technique. The cone repair technique is a useful surgical method for reconstructing a competent tricuspid valve, and can be applied in patients who have undergone previous tricuspid valve repair.

Robotically Assisted Mitral Valve Repair as the Treatment of Choice for Patients with Difficult Anatomies

  • Russo, Marco;Ouda, Hamed;Andreas, Martin;Taramasso, Maurizio;Benussi, Stefano;Maisano, Francesco;Weber, Alberto
    • Journal of Chest Surgery
    • /
    • v.52 no.1
    • /
    • pp.55-57
    • /
    • 2019
  • Robotically assisted mitral valve repair has proven its efficacy during the last decade. The most suitable approach for patients with difficult anatomies, such as morbid obesity, sternal deformities, cardiac rotation, or vascular anomalies, represents a current challenge in cardiac surgery. Herein, we present the case of a 71-year-old patient affected by severe degenerative mitral valve regurgitation with pectus excavatum and a right aortic arch with an anomalous course of the left subclavian artery who was successfully treated using a Da Vinci-assisted approach.

Tricuspid Edge-to-Edge Repair Versus Tricuspid Valve Replacement for Severe Tricuspid Regurgitation

  • Jihoon Kim;Heemoon Lee;Ji-Hyun Jung;Jae Suk Yoo
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.775-786
    • /
    • 2023
  • Background and Objectives: Tricuspid valve (TV) repair techniques other than annuloplasty remain challenging and frequently end in tricuspid valve replacement (TVR) in complicated cases. However, the results of TVR are suboptimal compared with TV repair. This study aimed to evaluate the clinical effectiveness of TV edge-to-edge repair (E2E) compared to TVR for severe tricuspid regurgitation (TR). Methods: We retrospectively reviewed 230 patients with severe TR who underwent E2E (n=139) or TVR (n=91) from 2001 to 2020. Clinical and echocardiographic results were analyzed using inverse probability of treatment weighting analysis and propensity score matching. Results: The two groups showed no significant differences in early mortality and morbidities. During the mean follow-up of 106.2±68.8 months, late severe TR and TV reoperation rates were not significantly different between groups. E2E group, however, showed better outcomes in overall survival (p=0.023), freedom from significant tricuspid stenosis (TS) (trans-tricuspid pressure gradient ≥5 mmHg, p=0.021), and freedom from TV-related events (p<0.001). Matched analysis showed consistent results. Conclusions: E2E for severe TR presented more favorable clinical outcomes than TVR. Our study supports that E2E might be a valuable option in severe TR surgery, avoiding TVR.

Surgical Treatment for Multivalvular Heart Disease (중복 심장판막 질환의 외과적 치료)

  • Kim, Jin; Jo, Jung-Ku;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.875-882
    • /
    • 1996
  • Multlvalvular heart surgery was performed In 78 cases, in the Department of Thoracic & Cardiovascu far Surgery of Chonbuk national University Hospital from november 1983 to March 1994. There Where 31 men and 47 women. whose ranged from 14 to 63 years. The causes of the valvular lesions were 57 rheumatic origin, 18 degenerative, 1 previous endocarditls, 1 prosthetic valve mal-function. There were 25 double valve replacement with or wit out tricuspid valve repair, i M VR and aortic valve repair, 18 MVR and tricuspid valve repair, 1 MVR and aortic and tricuspid valve repair, 10 AVR and mi- tral valve repair, 1 AVR and tricuspid valve repair, 8 mitral aortic valve repair, 13 mitral and tricuspid valve repair. They were improved mean New York Heart Association functional cldss, from 2.72% 121 Early deaths were 5 cases(6.4%). The cause of death wet'e low cArdiac output syndrome. veritricular tachycardia, massive bleeding and cerebral thromboembolism. All the survivors belonged to New York Heart Association functional class I or ll at discharge. The patients who had had valve replacement operation were medicated with warfarin to maintain the level of 30∼ 50% of normal prothrombin time. During follow-up(93.6%, mean 49.9 months), 2 late deaths were developed. One was due to intracranial hemorrhage and the other congestive heart failure. The pre-operative New York Heart Association Functional class IV was statistically sig ificant operat- ive risk factors(p< 0.05).

  • PDF

Numerical Investigation of Hemodynamics in a Bileaflet Mechanical Heart Valve using an Implicit FSI Based on the ALE Approach

  • Hong, Tae-Hyub;Choi, Choeng-Ryul;Kim, Chang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2410-2414
    • /
    • 2008
  • Human heart valves diseased by congenital heart defects, rheumatic fever, bacterial infection, cancer may cause stenosis or insufficiency in the valves. Treatment may be with medication but often involves valve repair or replacement (insertion of an artificial heart valve). Bileaflet mechanical heart valves (BMHVs) are widely implanted to replace the diseased heart valves, but still suffer from complications such as hemolysis, platelet activation, tissue overgrowth and device failure. These complications are closely related to both flow characteristics through the valves and leaflet dynamics. In this study, the physiological flow interacting with the moving leaflets in a bileaflet mechanical heart valve (BMHV) is simulated with a strongly coupled implicit fluid-structure interaction (FSI) method which is newly organized based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (remeshing) in FLUENT. The simulated results are in good agreement with previous experimental studies. This study shows the applicability of the present FSI model to the complicated physics interacting between fluid flow and moving boundary.

  • PDF

Outcomes of Combined Mitral Valve Repair and Aortic Valve Replacement (대동맥판막 치환술과 동반시행한 승모판막 성형술 결과)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Soo-Cheol;Lim, Cheong;Kim, Wook-Sung;Lee, Young-Tak;Choi, Hyun-Seok;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.463-471
    • /
    • 2003
  • The long-term results of combined mitral valve repair and aortic valve replacement (AVR) have not been well evaluated. This study was performed to investigate the early and long-term results of mitral valve repair with AVR. Material and Method: We retrospectively reviewed 45 patients who underwent mitral valve repair and AVR between September 1990 and April 2002. The average age was 47 years: 28 were men and 17 women. Twelve patients had atrial fibrillation and three had a previous cardiac operation. The mitral valve disease consisted of pure insufficiency (MR) in 34 patients, mitral stenosis (MS) in 3, and mixed lesion in 8. Mitral valve disease was due to rheumatic origin in 24 patients, degenerative in 11, annular dilatation in 8, and ischemia or endocarditis in 2. The functional anatomy of mitral valve was annular dilatation in 31 patients, chordal elongation in 19, leaflet thickening in 19, commissural fusion in 13, chordal fusion in 10, chordal rupture in 6, and so on. Aortic prostheses used included mechanical valve in 32 patients, tissue valve in 12, and pulmonary autograft in one. The techniques of mitral valve repair included annuloplasty in 32 patients and various valvuloplasty of 54 techniques in 29 patients. Total cardiopulmonary bypass and aortic cross clamp time were 204$\pm$62 minute and 153$\pm$57 minutes, respectively. Result: Early death was in one patient due to low output syndrome (2.2%). After follow up of 57$\pm$37 months, late death was in one patient and the actuarial survival at 10 years was 96$\pm$4%. Recurrent MR developed grade II or III in 11 patients and moderate MS in 3. Three patients required reoperation for valve-related complications. The actuarial freedom from recurrent MR, MS, and reoperation were 64$\pm$11%, 86$\pm$8%, and 89$\pm$7% respectively. Conclusion: Combined mitral valve repair with AVR offers good early and long-term survival, and adequate techniques and selection of indication of mitral valve repair, especially in rheumatic disease, are prerequisites for better long-term results.

Mitral Valve Repair for Active and Healed Endocarditis (급성 혹은 치유된 심내막염 환자에서의 승모판막성형술)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Sae;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Kang, Chang-Hyun;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Wook-Sung;Lee, Young-Tak;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.820-827
    • /
    • 2003
  • Background: Mitral valve repair rather than replacement for mitral regurgitation (MR) offers a number of well-accepted benefits. However, the surgical results of repair for mitral valve endocarditis remain largely unknown. Material and Method: Fourteen patients who underwent mitral valve repair for MR caused by mitral valve endocarditis from April 1995 through October 2001 were reviewed retrospectively. There were 9 male patients and mean age was 32$\pm$10 years. Four patients had previous embolism and 2 had active infections. The grade of MR were III in 6 patients and IV in 8. Operatively, mitral annuloplasty was performed in 12 patients and various valvuloplasty techniques were applied in all patients. One patient had immediate valve replacement due to residual MR after weaning of cardiopulmonary bypass. Result: There was no early operative death. Early postoperative transthoracic echocardiography revealed no or grade I of MR and no or mild mitral stenosis in 13 patients. After the mean follow-up of 36 months, there was no late death, and no or grade I of MR in 11 patients (84.6%) and no or mild mitral stenosis in 12 patients (92.3%). Reoperation required in one patient (7.1%). The cumulative freedom from recurrent MR and valve-related reoperation at 5 years were 91$\pm$9% and 75$\pm$22%, respectively. Conclusion: This study suggests that mitral valve repair for mitral regurgitation caused by endocarditis offers good early and intermediate survival and functional improvement without reinfection, and it is an attractive alternative to valve replacement in selective patients with bacterial endocariditis.

Mitral Valve Repair for Barlow's Disease with Mitral Annular and Subvalvular Calcification: A Case Report

  • Nakamae, Kosuke;Oshitomi, Takashi;Takaji, Kentaro;Uesugi, Hideyuki
    • Journal of Chest Surgery
    • /
    • v.55 no.2
    • /
    • pp.177-179
    • /
    • 2022
  • Barlow's disease with mitral annular calcification encompassing the subvalvular apparatus, including the valve leaflet and chordae, is extremely rare, and mitral valve repair in such cases is challenging. We report a case of a 60-year-old woman with mitral valve regurgitation that was successfully controlled by resecting the rough zone of P2 and calcifications on the excess leaflet regions and subvalvular apparatus, while retaining the calcification of P3 and implanting artificial chordae and an annuloplasty ring. Mitral valve repair for such cases requires an individualized and compounded surgical strategy for the technique to treat Barlow's disease and manage calcification to control mitral regurgitation.

Development and Animal Tests of Artificial Heart Valves (인공심장판막의 개발 및 동물실)

  • 이재영
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

Bentall Operation in a Patient with a Unicommissural Unicuspid Aortic Valve

  • Park, Sung Joon;Lee, Jae Hoon;Chung, Eui Suk
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.368-371
    • /
    • 2019
  • A unicuspid aortic valve is a rare congenital malformation that frequently presents with valvular dysfunction and dilatation or aortic aneurysm, requiring combined aortic valve surgery and aortic repair. Some patients show severe valve calcification extending into the interventricular septum, possibly resulting in damage to the conduction system during debridement for valve replacement. We present a rare case of severe aortic stenosis with a unicommissural unicuspid aortic valve diagnosed by preoperative transesophageal echocardiography in a 36-year-old man. After composite graft replacement of the aortic valve, aortic root, and ascending aorta, a permanent pacemaker was placed because of postoperative complete heart block.