• 제목/요약/키워드: heart valve prosthesis

검색결과 116건 처리시간 0.023초

Edwards Duromedics 기계판막의 판엽 이탈 -1예 보고- (Leaflet Escape of Edwards Duromedics Mechanical Heart Valve -Report of 1 case-)

  • 김재현;나찬영;백만종;서홍주;김종환;오삼세
    • Journal of Chest Surgery
    • /
    • 제37권4호
    • /
    • pp.373-375
    • /
    • 2004
  • Edwards Duromedics 기계판막은 잦은 판엽 이탈로 인해 1988년 5월부터 판매가 중지된 판막으로 국내에서는 현재까지 2예의 판엽 이탈이 보고되었다. 본원에서는 Edwards Duromedics 기계판막을 이용하여 승모판치환술을 받은 환자에서 발생한 판엽 이탈을 경험하였기에 증례 보고하는 바이다

ATS 인공 심장 판막의 단기 및 중기 임상성적 (Short and Intermediate Term Results of the ATS Heart Valve Replacement)

  • 임창영;문승철;양진영;구원모;김대식;이건;이헌재
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

스퀴즈필름효과를 고려한 인공심장밸브의 닫힘시 동적거동 해석 (Dynamic Behavior Analysis of the Heart Valve Prostheses Considering Squeeze Film Effect During Closing Phase)

  • 천길정
    • 대한기계학회논문집
    • /
    • 제19권2호
    • /
    • pp.443-450
    • /
    • 1995
  • An analysis of the dynamics of a mechanical monoleaflet heart valve prosthesis in the closing phase is presented. Employing the moment equilibrium principles on the occluder motion and the squeeze film dynamics of the fluid between the occluder and the guiding strut at the instant of impact, the velocity of the occluder tip and the impact force were computed. The dynamics of fluid being squeezed between the occluder and the guiding struts is accounted for by Reynold's equation. The effect of the fluid being squeezed between the occluder and the guiding strut was to reduce the velocity of the occluder tip at the instant of valve closure as well as dampen the fluttering of the occluder before coming to rest in the fully closed position. The squeeze film fluid pressure changed rapidly from a high positive value to a relatively large negative value in less than 1 msec. The results of this study may be extended for the analysis of cavitation inception, mechanical stresses on the formed elements and valve components as well as to estimate the endurance limits of the prosthetic valves.

인공심방판막실패에 대한 임상적 고찰 (Reoperation for prosthetic valve failure -clinical analysis of 15 cases-)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • 제19권4호
    • /
    • pp.584-594
    • /
    • 1986
  • Despite the multivariate improvements in tissue treatment, material, and design of prosthetic heart valves in recent years, numerous complications that may lead to valve dysfunction remain a constant threat after valve replacement. Most common indications for prosthetic valve failure are primary valve failure, infective endocarditis, paravalvular leakage, and thromboembolism. From 1977 to 1986, 15 patients underwent reoperation for prosthetic valve failure in 278 cases of valve surgery. The etiology of prosthetic valve failure were primary valve failure in 12 patients [80 %], infective endocarditis in 2 patients [13.3 %], and a paravalvular leakage [6.7 %]. The average durations of implantation were 45.5 months; 53.9 months in primary valve failure, 16 months in infective endocarditis, and 4 months in paravalvular leakage. The rate of valve failure was high under age of 30 [11/15]. Calcifications and collagen disruption of prosthesis were main cause of primary valve failure in macro- & micropathology. Prosthesis used in reoperation were 5 tissue valves and 10 mechanical valves. Operative mortality were 13.3 % [2/15], due to intractable endocarditis and ventricular arrhythmia.

  • PDF

CarboMedics 기계판막의 임상경험 (Mid term experience with CarboMedics Medical Valve)

  • 김기출
    • Journal of Chest Surgery
    • /
    • 제26권10호
    • /
    • pp.753-760
    • /
    • 1993
  • The CarboMedics valve is a bileaflet prosthesis with excellent hemodynamic characteristics, but the long term surgical experience with this valve, its durability and its biocompatibility are unknown. During a 5 year period from october 1988 to July 1993, 748 prostheses [402 mitral, 261 aortic, 58 tricuspid, 27 pulmonic] were inserted in 552 patients [mean age 40.2 years]. The operative mortality was 6.6% [37/560, 13.2% in age group below 15 years and 5.7% above 15 years]. and the main causes of death were complex congenital malformation and left ventricular failure. Follow up was totaled 1182 patient- years and mean follow up was 28.3 months/patient. No structural failure has been observed. Hemorrhage was the most frequent valve related complication[1.78% / Patient-year]. Embolism occurred at a rate of 0.93% / Patient-year. There were 5 cases of valve thrombosis [0.42% / Patient-year, two fatal]. There occurred 11 late deaths[6 valve related] and 42 valve related complications. Actuarial survival at 5 years is 97.18 0.94% and actuarial complication free survival at 5 years is 89.07 1.54%. In summary, the CarboMedics valve stands for a durable valve substitute, with low valve related complications.

  • PDF

인공심장판막의 재치환술 (Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases-)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • 제29권2호
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

PIV를 이용한 인공심장용 폴리우레탄 인공판막 하류의 유동 측정 : 맥동유동실험 (PIV Measurements of Flow Downstream of Polyurethane Heart Valve Prosthesis for Artificial Heart: Pulsatile Flow Experiment)

  • 유정열;김중경;성재용;장준근;민병구
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.629-639
    • /
    • 2002
  • In-vitro flow characteristics downstream of a polyurethane artificial heart valve and a Bjork-Shiley Monostrut mechanical valve have been comparatively investigated in pulsatile flow using particle image velocimetry (PIV). With a triggering system and a time-delayed circuit the velocity distributions on the two perpendicular measurement planes downstream of the valves are evaluated at any given instant in conjunction with the opening behaviors of valve leaflets during a cardiac cycle. The regions of stasis and high shear stress can be found simultaneously by examining the entire view of the instantaneous velocity and Reynolds shear stress fields. It is known that high shear stress regions exist at the interface between strong axial jet flows along the wall and vortical flows in the central area distal to the valves. In addition. there are large stagnation or recirculation regions in the vicinity of the valve leaflet, where thrombus formation can be induced by accumulation of blood elements damaged in the high shear stress zones. A correlation between the unsteady flow patterns downstream of the valve and the corresponding opening postures of the polyurethane valve membrane gives useful data necessary for improved design of the frame structure and leaflet geometry of the polyurethane valve.

Duromedics 승모판막의 판엽파손 (Duromedics Mitral Valve Leaflet Escape)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • 제25권7호
    • /
    • pp.750-755
    • /
    • 1992
  • We report a case of leaflet embolization of central leaflet fracture a 31mm mitral Edw-ards-Duromedics prosthesis. A leaflet was fractured to two segments, a larger one embolized to right common iliac artery and a smaller one to left femoral artery, respectively. Patient was reoperated with 29mm mitral Carbomedics prosthesis and incidentally found of smaller segment in left femoral artery at cannulation site. The embolectomy was done 15 days after cardiac operation through midline abdominal incision, Leaflet escape of a mitral Edward-Duromedics prosthesis is a rare, potentially curable mode of valve failure. After mechanical valve replacement, unexplained heart failure and acute pulmonary edema, mechanical valve failure should be suspected. Correct interpretation of clinical signs, symptoms and fluroscopy should allow early diagnosis of leaflet escape and prompt surgical therapy.

  • PDF

Effects of a Personalized Nurse-Led Educational Program for New Patients Receiving Oral Anticoagulant Therapy after Mechanical Heart Valve Prosthesis Implantation on Adherence to Treatment

  • Eltheni, Rokeia;Schizas, Nikolaos;Michopanou, Nektaria;Fildissis, Georgios
    • Journal of Chest Surgery
    • /
    • 제54권1호
    • /
    • pp.25-30
    • /
    • 2021
  • Background: Life-long anticoagulant therapy is mandatory for patients who undergo heart valve replacement with implantation of a mechanical prosthesis. The aim of this study was to investigate the effects of a nurse-led patient educational program concerning oral anticoagulant therapy intake after heart valve replacement surgery on patients' knowledge of important parameters of anticoagulant administration. Methods: In this single-center study, 200 patients who underwent surgical implantation of a mechanical prosthesis were divided into 2 groups. The control group received the basic education concerning oral anticoagulants, while the intervention group received a personalized educational program. Results: Personalized education was correlated with a better regulation of therapeutic international normalized ratio (INR) levels and adequate knowledge among patients. Therapeutic levels of INR were achieved in 45% of the patients during the first month, 71% in the third month, and 89% in the sixth month after discharge in the intervention group, compared to 25%, 47%, and 76% in the control group, respectively. Patients' satisfaction with the information was higher in the intervention group than in the control group. The percentage of satisfaction reached 80% for the intervention group versus 37% for the patients of the control group. Conclusion: The implementation of the nurse-led educational programs was associated with improved clinical results and increased adherence to oral anticoagulant treatment.