• Title/Summary/Keyword: heart valve

Search Result 814, Processing Time 0.021 seconds

Bentall Operation in a Patient with a Unicommissural Unicuspid Aortic Valve

  • Park, Sung Joon;Lee, Jae Hoon;Chung, Eui Suk
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.368-371
    • /
    • 2019
  • A unicuspid aortic valve is a rare congenital malformation that frequently presents with valvular dysfunction and dilatation or aortic aneurysm, requiring combined aortic valve surgery and aortic repair. Some patients show severe valve calcification extending into the interventricular septum, possibly resulting in damage to the conduction system during debridement for valve replacement. We present a rare case of severe aortic stenosis with a unicommissural unicuspid aortic valve diagnosed by preoperative transesophageal echocardiography in a 36-year-old man. After composite graft replacement of the aortic valve, aortic root, and ascending aorta, a permanent pacemaker was placed because of postoperative complete heart block.

Transcatheter Mitral Valve Implantation in Open Heart Surgery: An Off-Label Technique

  • Alfonsi, Jacopo;Murana, Giacomo;Corsini, Anna;Savini, Carlo;Di Bartolomeo, Roberto;Pacini, Davide
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.467-470
    • /
    • 2017
  • Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. The aortic valve was replaced using a stentless valve prosthesis (LivaNova S OLO; LivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.

clinical experience of cardiovascular surgery -An Analysis of 116 cases- (심장혈관질환의 수술치험)

  • Ahn Byoung-Hai;Kim, Seong-Hwan;Youm, Wook
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.250-258
    • /
    • 1986
  • From Aug. 1984 to May 1986, 116 cases of cardiovascular surgery including 85 cases of open heart surgery were performed at Korea Veterans Hospital. There were 108 congenital anomalies and 8 acquired valvular heart diseases. Among 108 congenital malformations 92 operations were done for acyanotic group, and 16 operations for cyanotic group. Thirteen cases of open heart surgery for infants or small children under 10kg of body weight were performed, which occupied 15.3 percent of total open heart surgery done in the same period. Common congenital cardiovascular anomalies were ventricular septal defect [40.7%], patent ductus arteriosus [29.6%], tetralogy of Fallot [12.[%], atrial septal defect [11.1%], and pulmonary stenosis [1.9%] in order of frequency. Valve replacement using lonescu-Shiley or Carpentier-Edwards valve was performed for 8 cases of acquired mitral valve disease, and valve replacement using St. Jude valve was done for a case of patent ductus arteriosus with severe mitral insufficiency. There was no mortality in acyanotic congenital malformations and acquired valve lesions, and 5 cases of mortality in cyanotic congenital malformations. Overall mortality was 4.3 percent for total cases and 5.9 percent for 85 cases of open heart surgery.

  • PDF

Design of a Mechanical Artificial Heart Valve Prosthesis Appliing Design Methodology (설계방법론을 이용한 기계식 인공심장판막의 설계)

  • 천길정;류형태
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.291-296
    • /
    • 1998
  • A new mechanical heart valve prosthesis has been designed appling systematic design methodology. The function of the heart valve was defined, and search for design variation has been carried out according to the functional structure, Optimal model among the various variations was determined in view of the design specificationn. Proto type valve was fabricated and test has been carried out using a mock circulation system. It has been observed that the pressure profile, cardiac output and behavior characteristics are generally satisfactory.

  • PDF

Surgical Treatment of Native Valve Endocarditis (감염성 심내막염의 외과적 치료)

  • Kim, Ae-Jung;Kim, Min-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.28 no.9
    • /
    • pp.822-828
    • /
    • 1995
  • This paper reports 15 native valve endocarditis cases had surgical operation in the past 10 years at the department of Cardiovascular and Thoracic Surgery, Chonbuk National University Hospital. In this study, 10 cases out of 15 were in class I or II by the New York Heart Association functional classification. None of the cases had a history of taking addictive drugs. Five cases were congenital heart disease, three cases were rheumatic heart disease and two cases were degenerative heart disease. Thus 10 cases had the underlying disease. All cases had antibiotics treatment for 3 to 6 weeks before operation. In the culture test, only four cases were positive in the blood culture and one case was positive in the excised valve culture. Organisms on blood and valve culture were Streptococcus epidermis, Streptococcus viridans, Staphylococcus aureus and Staphylococcus epidermidis. In the 10 cases without ventricular septal defect, the aortic valve was involved in four, mitral in four, both in two and involved valves in the 5 cases with ventricular septal defect were tricuspid in three, pulmonic in two. Eight cases had operation because they showed moderate congestive heart failure due to valvular insufficiency and vegetation with or without embolism. Seven cases had operation because they showed persistent or progressive congestive heart failure and/or uncontrolled infection. Five cases with ventricular septal defect underwent the closure of ventricular septal defect, vegetectomy and leaflet excision of the affected valves without valve replacement. In the cases without ventricular septal defect, the affected valves were replaced with St. Jude mechanical prosthesis. Postoperative complications were recurrent endocarditis in two, embolism in one, allergic vasculitis in two, spleen rupture in one and postpericardiotomy syndrome in one. At the first postoperative day, one case died of cerebral embolism. At the 11th postoperative month, one case died of recurrent endocarditis and paravalvular leakage in spite of a couple of aortic valve replacement. In the survived cases[13 cases in this study , all cases but one became class I or II by the New York Heart Association functional classification.

  • PDF

Clinical Evaluation of Multiple Valve Replacement (심장다판치환술의 임상적 고찰)

  • 오상기
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.160-166
    • /
    • 2000
  • Background: The purpose of this study is to evaluate and analyze the surgical results in patients undergoing operations for multiple for multiple valvular heart diseases. Material and method: From April 1982 to June 1997 multiple valve replacement was performed in 150 patients mitral and aortic valve replacement were done in 135 patients mitral and tricuspid valve replacements in 10 patients triple replacements in 4 patients and aortic and tricuspid valve replacement in 1 patient. Of the valves implanted 157 were St. Jude 104 Duromedics 20 Carpenter-Edwards 6 Bjork-Shiley 6 Ionescu-Shiley and 2 Medtronics. Result: The hospital mortality rate was 10.7% (16/150) and the late mortality rate was 7.2% (8/134) The mortality rate was high in early operative period but decreased with time. The causes of death were low cardiac output in 9 sudden death in 3 congestive heart failure in 3 bleeding in 2 cerebral thrombosis in 1 leukemia in 1 multiorgan failure in 1 and so on . The actuarial survival rate excluding operative death was 83.1% at 15 years. Conclusion: With a follow-up now extending to 15 years the multiple valve replacement continues to be reliable procedure with relatively low mortality and morbidity.

  • PDF

Open Heart Surgery 110 Cases in One Year(1987) (연간 (1987년) 개심술 110례에 대한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.351-365
    • /
    • 1988
  • During one year[1987], 110 cases of open heart surgeries were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje Medical College. And the results were summarized as follows. 1. Among the 110 cases, there were 77 cases of congenital heart diseases and 33 cases of acquired heart diseases. Age range of the congenital patients was 8 months to 30 years with the mean age of 8 years, and acquired patients was 16 to 56 years with the mean age was 32 years. 2. The heart lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 50 of membrane type and 60 of bubble type. For all cases GIK[glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 77 congenital anomalies, there were 67 cases of acyanotic patients[ASD: 12, VSD: 50, PS: 1, AP window: 1, Gerbode defect: 1, ECD: 2] and 10 cases of cyanotic patients[TOF: 10], and to all of which the appropriate radical operations were applied. 4. Among the 33 acquired diseases, there were one case of left atrial myxoma, one of annuloaortic ectasia, 20 of mitral valve diseases[MS: 2, MSr: 8, MR: 2, MRs: 8], 9 of double valve diseases[MRs+AR: 1, MRs+ARs: 2, MRs+TR: 1, MSr+TR: 3, MSr+ASr: 1, MSr+ARs: 1], 2 of triple valve diseases[MSr+AR+TR: 1, MSr+ASr+TR: 1]. The left atrial myxoma was removed well with right atriotomy and atrial septal approach. And to the annuloaortic ectasia, Bentall operation was applied with good result. Mitral valve replacement[MVR] was applied to 20 cases of mitral valve diseases, double valve replacement[MVR+AVR] was applied to 6 cases of double valve diseases, MVR & tricuspid annuloplasty[TVA] was applied to 3 cases of mitral 5. The number of replaced valve were 39 in 31 cases. In MVR, 5 of mechanical valves[St. Jude Medical Valve] and 26 of tissue valves[Carpentier-Edward valve] were used. In AVR, 3 of mechanical valves and 5 of tissue valves were used. 6. Postoperative complications were occurred in 23 cases, and among them 21 cases were recovered with intensive cares, but 2 cases were expired[mortality: 1.8%].

  • PDF

Papillary Fibroelastoma of Pulmonary Valve with Congestive Heart Failure -A case report- (심부전을 동반한 폐동맥 판막의 유두상 섬유탄력종 - 1예 보고 -)

  • CheKar, Jay-Key;Ahn, Byoung-Hee;Oh, Sang-Gi;Jeong, In-Seok;Yun, Chi-Hyeong;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.176-179
    • /
    • 2010
  • Cardiac papillary fibroelastomas are the second most common primary tumor of the heart and they most commonly affect the left cardiac valves. However, occurrence of this tumor on the right side of the heart has been rarely reported, with only a few cases having been documented on the pulmonary valve. We present here a rare case of a papillary fibroelastoma that occurred on the pulmonary valve and this was successfully managed by replacing the pulmonary valve in a patient with congestive heart failure.

In Vitro Motion Analysis of Supplementary Valve (생체외 실험을 이용한 보조판막의 운동 연구)

  • 김상현;박영환
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • To develop the supplementary heart valve which could reduce the complications of prosthetic heart valve, in vitro experiments were performed to analyze the movement of the supplement valves from the view point of the flow dynamics and leaflet dynamics. The autologous pericardium was attached to deficient portion of the porcine valve which was dissected completely and partially. The pericardium was treated by buffered glutaraldehyde solution in the preshaped mould to preserve the shape of the leaflet. The function of the valves were evaluated in the mock circulatory system and three sets of experiment were performed. The instantaneous motion of the leaflet was pictured by the 35mm camera and the pressure drop through the valve and cardiac output were measured. The supplementary valve which was replaced completely performed better thatn the valve replaced partially. In vitro experiments showed that the supplementary valve which was replaced completely performed better than the valve replaced partially. In vitro experiments showed that the supplementary valve could undertake the prosthetic heart valve in clinic.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF