• Title/Summary/Keyword: heart rate band

Search Result 54, Processing Time 0.028 seconds

Autonomic Neurocardiac Function in Patients with Major Depressive Disorder - Using a Heart Rate Variability Test Battery - (주요우울장애 환자에서의 자율신경심장기능 - Heart Rate Variability 검사를 사용하여 -)

  • Park, Young-Su;Lee, Kang-Joon;Kim, Hyun;Chung, Young-Cho
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.2
    • /
    • pp.100-105
    • /
    • 2004
  • Objectives: Major depression is associated with an increased risk of cardiovascular mortality. One possible explanation for this association is that major depression influences autonomic neurocardiac regulation. However, previous studies on the relationship between heart rate variability (HRV) and major depression have revealed conflicting results. The purpose of this study is to clarify that major depressive patients compared to healthy controls show a reduction in HRV as an expression of reduced modulation of vagal activity to the heart. Methods: According to DSM-IV, the time and frequency domain HRV indices (5-min resting study) of 30 patients with major depressive disorder were compared with those of 30 healthy controls. Standardized HRV tests enable quantitative estimation of autonomic nervous system function. Results: After controlling for age and gender, subjects with major depression showed a higher heart rate and significantly lower modulation of cardiovagal activity compared to controls. The total power (TP) band, very low frequency (VLF: 0.003-0.04 Hz) band, low frequency (LF: 0.04-0.15 Hz) band, and high frequency (HF: 0.15-0.4 Hz) band were significantly reduced in subjects with major depression compared to control subjects. Conclusion: Patients with major depression may suffer from functional disturbances in the interaction between the sympathetic and parasympathetic autonomic systems.

  • PDF

Wearable Human Health-monitoring Band using Inkjet-printed Flexible Temperature Sensor

  • Han, Dong Cheul;Shin, Han Jae;Yeom, Se Hyeok;Lee, Wanghoon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.301-305
    • /
    • 2017
  • This paper presents a wearable human health-monitoring band. The band consists of a body temperature detector (BTD) and a hear rate detector (HRD). The BTD and HRD are realized using an inkjet-printed flexible temperature sensor and a commercial heart rate sensor module, respectively. The sensitivity of the fabricated BTD was found to be $-31/^{\circ}C$ with a linearity of 99.82%. The HRD using the commercial heart rate sensor module has a good performance with a standard deviation of 0.85 between the data of a commercial smart watch and the fabricated HRD.

The heart rate variability(HRV) of the headache patients caused by Chiljungsang (칠정상(七情傷)으로 인한 두통 환자의 심박변이도(Heart Rate Variability)에 관한 고찰)

  • Park, Sun-Yong;Choi, Cheol-Hong;Chung, Dae-Kyoo;Ko, Kyung-Mo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.3
    • /
    • pp.45-54
    • /
    • 2008
  • Objective: To treat psychogenic headache patients, doctors have to amplify on the headache caused by emotional stress to patients, and assist the patients to cope with difficulties. So, we investigated HRV of the headache patients caused by Chiljungsang and would like to apply to the clinical treatment. Method: Our study measured time and frequency domain HRV indicies(5-min resting study) of 123 headache patients caused by emotional stress. Standardized tests of HRV allow a quantitative estimation of autonomic nervous system function. Results & Conclusions: 1. The study classed as aspects of the head pain showed the differences in RMS-SD(square root of mean squared difference of successive NN intervals) band, HF(high frequency) band significantly. 2. The male headache patients showed higher all the indicies except heart rate compared to the female patients, significantly in SDNN(standard deviation of NN interval), TP(total Power), HF band. 3. As the patients grow older, SDNN, RMS-SD band was lower and LF(low frequency) band, LF/HF ratio higher significantly. The beginning age lower, SDNN, RMS-SD band was higher significantly. The duration of the disease longer, LF band, LF/HF ratio was higher significantly.

  • PDF

Ballistocardiographical Heart Rate Measurement Using Head Mounted 6-axis Accelerometer (머리 착용형 6축 가속도계를 사용한 심탄도 심박수 측정)

  • Jinman Kim;Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.33-37
    • /
    • 2024
  • Recently, wearable virtual reality devices are widely used. These instruments include a 3-axis accelerometer. User's heart rate information in virtual reality contents can be useful for measuring user experience. In this paper, we propose a method to measure the heart rate through a 3-axis accelerometer based on the principle of ballistocardiography without additional sensors. The angular velocity was successively measured in a time series by the 3-axis accelerometer mounted to the head. The frequency of the maximum magnitude is determined as the heart rate through frequency transform and band pass filtering of the time series signal. For verification, the heart rate calculated from photoplethysmography sensors acquired at the same time was compared as ground-truth. In the virtual reality, the user's heart rate information can be extracted without additional heart rate sensor, and the emotional state and fatigue can be measured.

  • PDF

A Comparative Study on the Conductivity and Physical Properties of Conductive Materials for Heart Rate Monitoring (심박 모니터링을 위한 전도성 소재의 전도성 및 물성 비교 연구)

  • Kim, Jimin;Kim, Jongjun
    • Journal of Fashion Business
    • /
    • v.22 no.4
    • /
    • pp.118-129
    • /
    • 2018
  • The purpose of this study is to develop ECG electrode materials for the heart rate monitoring smart band, a smart device used for ECG and heart rate measurement. The purpose of the evaluation is to assess properties and conductivity of electrodes of the existing heart rate monitoring smart band, and to determine suitability through a representative conductive sample. Because level of thickness does not differ significantly from value of conductive specimen from thickness of the smart band, it can be used as a conductive electrode. Surface conductivity of conductive samples and smart bands, is expected to be available as electrodes except for conductive film. Also, since the knit have conductivity only in the metal processing layer, it is necessary to use electrodes on the part of the metal processing layer that is conductive when applying the knit. Tensile strength and electrical conductivity of the tensile were generally revealed to have a tendency. Thickness of the specimen that can be used as an electrode for the smart band is suitable for all samples, electrical resistance, conductive woven, conductive knit, and conductive cord. In the case of conductive cord, however, the electrode attached to the human body will not conform to the flat shape of the electrode attached to the human body. Therefore, the conductive woven and the conductive knit will be available as an electrode.

Effect of the Korean Skirt-Band Size on Pressure and Cardiopulmonary Function of Human Body (한복 치마허리 치수가 인체의 압력과 심폐기능에 미치는 영향)

  • Rhie JeonSook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.2 s.30
    • /
    • pp.109-116
    • /
    • 1989
  • Korean clothings are admired for their beauty and traditional value. On the other hand, many of Korean women complain of chest restriction. Korean skirts may give high garment pressure to the wearers because the Korean skirt-band do not resolve physical tensions in size or in stretch. This paper aims at the identification of the garment pressure caused by the Korean skirt-band and the cardiopulmonary change caused by garment pressure. The Korean skirt-band were made in 3 kinds of size, and 21 women were selected for wearing test. The garment pressure was measured in front, side, and back parts of the body. The measured cardiopulmonary parameters were vital capacity, respiratory rate, heart rate, and blood pressure. The results were as follows: 1. The smaller the size of the Korean skirt-band, the greater the garment pressure. The pressure during inspiration was significantly greater than the pressure during expiration. 2. The pressure in side part was the greatest of the three measurements and the pressure in back part was the smallest. 3. The small size of the Korean skirt-band revealed low vital capcity and great respiratory rate. 4. As the small size grement was dressed, the respiratory rate and the heart rate during walking and rest after walking were significantly high. 5. Subjects felt uncomfortable when they wore small sized garment.

  • PDF

Heart Rate Signal Extraction by Using Finger vein Recognition System (지정맥 인식 시스템을 이용한 심박신호 검출)

  • Bok, Jin Yeong;Suh, Kun Ha;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.701-709
    • /
    • 2019
  • Recently, heart rate signal, which is one of biological signals, have been used in various fields related to healthcare. Conventionally, most of the proposed heart rate signal detection methods are contact type methods, but there is a problem of discomfort that the subject have to contact with the device. In order to solve the problem, detection study by non-contact method has been progressed recently. The detected heart rate signal can be used for finger vein liveness detection and various application using heart rate. In this paper, we propose a method to obtain heart rate signal by using finger vein imaging system. The proposed method detected the signal from the changes of the brightness value in the time domain of the infrared finger vein images and converted it into the frequency domain using the image processing algorithm. After the conversion, we removed the noise not related to the heart rate signal through band-pass filtering. In order to evaluate the accuracy of the signal, we analyzed the correlation with the signal obtained simultaneously with the finger vein acquisition device and contact type PPG sensor approved by KFDA. As a result, it was possible to confirm that the heart rate signal detected in non-contact method through the finger vein image coincides with the waveform of actual heart rate signal.

Respiration and Heartbeat detection algorithm using UWB radar (UWB 레이더를 사용한 호흡 및 심박 감지 알고리즘)

  • Le, Minhhuy;Hwang, Lan-mi;Fedotov, Dmitry
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2019
  • Ultra Wideband (UWB) Radar is a high-resolution radar for short distance detection which uses signals transmitted and received by each antennas in order to detect a target. It is possible to detect the respiration and heartbeat of a person without contact It is getting more and more often utilized since it is not affected by physical environment. In this paper, we implement an algorithm to detect human respiration and heartbeat rate using UWB radar signal. We process radar signals reflected from human body using Median filter, Kalman filter, Band Pass filter and so on. We also use CZT to extract breathing and heart rate. ECG (Electrocardiogram) was used for comparison of heartbeat data and we confirm that each data of ECG and UWB Radar were more than 98% identical each other.

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.

The Effect of Electroacupuncture at Sobu(HT8) on the EEG and HRV (소부(HT8) 전침이 뇌파(EEG)와 심박변이도(HRV)에 미치는 영향)

  • Yoon, Dae Shik;Hong, Seung-Won;Lee, Yong-Sub
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.305-318
    • /
    • 2013
  • Objectives : The aim of this study was to examine the effect of electroacupuncture(EA) at an acupoint, HT8(Sobu), on normal humans by using power spectral analysis. We examined the effect on the Heart Rate Variability(HRV), and the balance of the autonomic nervous system. Methods : Thirty-two healthy volunteers participated in this study. EEG(Electroencephalogram) power spectrum exhibits site-specific and state-related differences in specific frequency bands. A thirty-two channel EEG study was carried out on thirty-two subjects(14 males; mean age=23.5 years old, 18 females; mean age=21.5 years old). HRV and EEG were simultaneously recorded before and after acupuncture. Results : In the ${\alpha}$(alpha) band, during the HT8-acupoint treatment, the power values in the ${\alpha}$(alpha) band significantly decreased(p<0.05) at 28 channels. In the ${\beta}$(beta) band significantly decreased(p<0.05) at 26 channels. In ${\delta}$(delta) band significantly decreased(p<0.05) at 18 channels. In ${\theta}$(theta) band significantly decreased(p<0.05) at 20 channels. ${\alpha}/{\beta}$ values were increased at 6 channels and decreased at 10 channels.${\beta}/{\theta}$ values were increased at 10 channels and decreased at 19 channels. Mean-RR(RR-interval), Complexity, RMSSD(Root mean square of successive differences), SDSD(Standard deviations differences between adjacent normal R-R intervals), norm HF showed a significantly increased and mean-HRV, norm LF, LHR(LF/HF Ratio) showed a significantly decreased after HT8-acupoint treatment(p<0.05). Conclusions : These results suggest that EA at the HT8 mostly causes significant changes on alpha(28 channels), beta(26 channels), delta(18 channels), theta(20 channels) bands and mean-HRV, mean-RR, complexity, RMSSD, SDSD, norm LF, norm HF and LHR. If practicing EA at the HT8, it will regulate the function of the cerebral cortex, decrease activity of the sympathetic and increase parasympathetic nervous activity.