• Title/Summary/Keyword: hearing aid

Search Result 175, Processing Time 0.021 seconds

Investigating the Effects of Hearing Loss and Hearing Aid Digital Delay on Sound-Induced Flash Illusion

  • Moradi, Vahid;Kheirkhah, Kiana;Farahani, Saeid;Kavianpour, Iman
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.174-179
    • /
    • 2020
  • Background and Objectives: The integration of auditory-visual speech information improves speech perception; however, if the auditory system input is disrupted due to hearing loss, auditory and visual inputs cannot be fully integrated. Additionally, temporal coincidence of auditory and visual input is a significantly important factor in integrating the input of these two senses. Time delayed acoustic pathway caused by the signal passing through digital signal processing. Therefore, this study aimed to investigate the effects of hearing loss and hearing aid digital delay circuit on sound-induced flash illusion. Subjects and Methods: A total of 13 adults with normal hearing, 13 with mild to moderate hearing loss, and 13 with moderate to severe hearing loss were enrolled in this study. Subsequently, the sound-induced flash illusion test was conducted, and the results were analyzed. Results: The results showed that hearing aid digital delay and hearing loss had no detrimental effect on sound-induced flash illusion. Conclusions: Transmission velocity and neural transduction rate of the auditory inputs decreased in patients with hearing loss. Hence, the integrating auditory and visual sensory cannot be combined completely. Although the transmission rate of the auditory sense input was approximately normal when the hearing aid was prescribed. Thus, it can be concluded that the processing delay in the hearing aid circuit is insufficient to disrupt the integration of auditory and visual information.

A Development of Telephone for the Hearing Impaired to Improve Listening Ability of Telephone Speech (난청인의 통화 청취도 향상을 위한 전화기 개발)

  • 이상민;송철규;이영묵;김원기
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.457-466
    • /
    • 1997
  • We developed a new hearing aid telephone which helps the hearing impaired person to improve the listening ability of telephone speech. Recently, the hearing impaired person and the elderly who has hearing loss have been continuously increased and their desire for participating society as a producer has been increased also. So they strong1y want the hearing aid devices which make compensation fortheir handicap. The hearing aid telephone is one of the basic aid devices that helps the hearing impaired to communicate well with other poeple and to acquire easily useful information through the phone. We analyze the hearing ability of the hearing impaired, design the new model of the hearing aid telephone and test the telephone in three fields-electrical, word perception, user test. Our new tolephone has lour band pass filter channels and the center frequencies of these filters are 500, 1000, 2000, 3000Hz which are considered psychoacoustic factors and telephone line characteristics. The hearing impaired can adjust the total gain characteristics of receiving sound to his hearing ability by setting four volumes in the telelphone. This procedure is called fitting which is a very important factor for the hearing impaired to take meaning of speech. The total gain of this telephone is over 20dB from 250Hz to 3200Hz range. From the results of the tests we certify that our new model is better for the hearing impaired to understand the meaning or telephone speech than the old general models. The next step of developing the hearing aid telephone is to study about compressing sidetone and noise, dividing frequency bands, selecting hearing aid pattern and compensating psychoacoustic loudness. we expect that the advanced hearing aid telephone can be developed by the research about speech perception characteristics of the hearing impaired in engineering and clinical side.

  • PDF

Investigating the Effects of Hearing Loss and Hearing Aid Digital Delay on Sound-Induced Flash Illusion

  • Moradi, Vahid;Kheirkhah, Kiana;Farahani, Saeid;Kavianpour, Iman
    • Korean Journal of Audiology
    • /
    • v.24 no.4
    • /
    • pp.174-179
    • /
    • 2020
  • Background and Objectives: The integration of auditory-visual speech information improves speech perception; however, if the auditory system input is disrupted due to hearing loss, auditory and visual inputs cannot be fully integrated. Additionally, temporal coincidence of auditory and visual input is a significantly important factor in integrating the input of these two senses. Time delayed acoustic pathway caused by the signal passing through digital signal processing. Therefore, this study aimed to investigate the effects of hearing loss and hearing aid digital delay circuit on sound-induced flash illusion. Subjects and Methods: A total of 13 adults with normal hearing, 13 with mild to moderate hearing loss, and 13 with moderate to severe hearing loss were enrolled in this study. Subsequently, the sound-induced flash illusion test was conducted, and the results were analyzed. Results: The results showed that hearing aid digital delay and hearing loss had no detrimental effect on sound-induced flash illusion. Conclusions: Transmission velocity and neural transduction rate of the auditory inputs decreased in patients with hearing loss. Hence, the integrating auditory and visual sensory cannot be combined completely. Although the transmission rate of the auditory sense input was approximately normal when the hearing aid was prescribed. Thus, it can be concluded that the processing delay in the hearing aid circuit is insufficient to disrupt the integration of auditory and visual information.

The Effects of Hearing Aid Digital Noise Reduction and Directionality on Acceptable Noise Level

  • Ahmadi, Roghayeh;Jalilvand, Hamid;Mahdavi, Mohammad Ebrahim;Ahmadi, Fatemeh;Baghban, Ali Reza Akbarzade
    • Clinical and Experimental Otorhinolaryngology
    • /
    • v.11 no.4
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives. Two main digital signal processing technologies inside the modern hearing aid to provide the best conditions for hearing aid users are directionality (DIR) and digital noise reduction (DNR) algorithms. There are various possible settings for these algorithms. The present study evaluates the effects of various DIR and DNR conditions (both separately and in combination) on listening comfort among hearing aid users. Methods. In 18 participants who received hearing aid fitting services from the Rehabilitation School of Shahid Beheshti University of Medical Sciences regularly, we applied acceptable noise level (ANL) as our subjective measure of listening comfort. We evaluated both of these under six different hearing aid conditions: omnidirectional-baseline, omnidirectional-broadband DNR, omnidirectional-multichannel DNR, directional, directional-broadband DNR, and directional-multichannel DNR. Results. The ANL results ranged from -3 dB to 14 dB in all conditions. The results show, among all conditions, both the omnidirectional-baseline condition and the omnidirectional-broadband DNR condition are the worst conditions for listening in noise. The DIR always reduces the amount of noise that patients received during testing. The DNR algorithm does not improve listening in noise significantly when compared with the DIR algorithms. Although both DNR and DIR algorithms yielded a lower ANL, the DIR algorithm was more effective than the DNR. Conclusion. The DIR and DNR technologies provide listening comfort in the presence of noise. Thus, user benefit depends on how the digital signal processing settings inside the hearing aid are adjusted.

Developments of A Hearing Aid Algorithm with Emphasis on Adaptive Feedback Cancellation and Hardware Module (적응 궤환 제거가 강조된 보청기 알고리즘과 하드웨어 모듈 개발)

  • Jung, Sun-Yong;Ji, Yun-Sang;Kim, In-Young;Park, Young-Cheol;Kim, Nam-Gyun;Lee, Sang-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.282-290
    • /
    • 2006
  • We have developed a multi band digital hearing aid algorithm emphasizing feedback cancellation and a hardware module to evaluate the performance of our algorithm. The hearing aids should be able to compensate for individual hearing loss characteristics of hearing impaired person. Thus hearing aids need the function of multi-bands amplification and the capabilities of feedback cancellation that can remove howling caused by acoustic feedback. In this paper, we proposed a digital hearing aid algorithm which has multi-bands compensation using modified discrete cosine transform (MDCT) and can efficiently remove acoustic feedbacks. Moreover, we have developed digital hearing aid hardware module, which can evaluate hearing aid algorithms in real time operation. The developed algorithm and hardware module were verified through computer simulation and clinical tests. Through operational experiments, good performances in real time operation environment and an efficient howling cancellation were also observed. The developed hardware module can operate in stable condition and it is expected to become a good hardware platform for developing hearing aid algorithms.

64 Channel Noise Masking Digital Hearing Aid Firmware Development (64채널 소음 차폐 디지털 보청기 펌웨어 개발)

  • Jarng, Soon-Suck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.367-372
    • /
    • 2012
  • This paper introduces noise masking algorithm for 64 channel digital hearing aid. 125 Hz spectral resolution is maintained for 64 channels from 125 Hz to 8000 Hz. The same spectral masking processing effects as the cochlea are considered and applied for the present hearing aid noise reduction processing algorithm. Theoretical algorithm has been ported into assembler language program software and been embedded into a DSP IC chip for the digital hearing aid. Some parts of noise masking software program code are explained, and the results of the real-time noise reduction are verified by electro-acoustic measurements.

A Physical Cochlear Model for Transducer Performance Evaluation of Implantable Hearing Aid with Round Window Driver (정원창 구동기의 진동체 성능 평가를 위한 내이 물리모델)

  • Shin, Dong Ho;Lim, Hyung Gyu;Jung, Eui Sung;Seong, Ki Woong;Lee, Jyung Hyun;Cho, Jin Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.150-155
    • /
    • 2013
  • Recently, various hearing aids are developed to overcome hearing loss. There are available hearing aids, such as air conduction hearing aid, implantable middle ear hearing aid and so on. But air conduction hearing aid is inconvenience caused by howling, and ossicle chain driving type implantable middle ear hearing aid has some week point due to problem of possible nercobiosis of coupling spot along incus long process. In recent years, in order to improve these shortcomings round window (RW) driving hearing aid has been paying attention. In this paper, the physical cochlear model is proposed for a performance evaluation of the RW driving hearing aids of a transducer. In order to verify an experiment proposed on a performance of physical cochlear model, the transducer which has ossicles characteristics is used. By measuring and comparing the frequency characteristics of transducer with ossicles and human temporal bone, performance of physical cochlear model was verified. As from the result of experiment, it is expected that an implemented cochlear model is useful for evaluating characteristics of RW transducer.

Quality of Life Comparison between Suspicion Hearing Impaired and Hearing Aids Users in Elderly (노인에서 난청 의심자와 보청기 사용자의 삶의 질 비교)

  • Son, Byungchang;Heo, Seungdeok
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.141-147
    • /
    • 2018
  • Purpose : Aim of the this study was conducted to determine whether hearing aids are responsible for the quality of life by comparing quality of life between the elderly who are suspected of difficulty in hearing selected by Hearing Handicap Inventory of Elderly (HHIE) without using hearing aids and who are using hearing aids. Methods : For the study, two groups of 33 people were analyzed for independent t-test based on whether they wore Hearing Aids (HA) or not whom wearing hearing aids (hearing aids users) and suspected difficulty in hearing. who are attending the Religious organization Senior Welfare Center in the OO region. Result : The quality of life of hearing aid users is generally observed to be higher than that of non-users in general, and by the section, psychological (p=0.019) and living environment (p=0.032) were appeared statistically signigicant. The elderly showed a significant difference. In the section, "Operation Satisfaction (p=0.038)" in the physical health area, "relationship of reason (p=0.018)" in the social relationship area, "Economic margin (p=0.021)" in the environmental area, "Information accessibility (p=0.020)", In the psychological area, hearing aid was used for "self satisfaction (p=0.033)", "concentration of work (p=0.045)". Conclusion : The use of hearing aids by hearing loss elderly improves the quality of life in the psychological health and living environment section.

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

A New Hearing Aid Algorithm for Speech Discrimination using ICA and Multi-band Loudness Compensation

  • Lee Sangmin;Won Jong Ho;Park Hyung Min;Hong Sung Hwa;Kim In Young;Kim Sun I.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.177-184
    • /
    • 2005
  • In this paper, we proposed a new hearing aid algorithm to improve SNR(signal to noise ratio) of noisy speech signal and speech perception. The proposed hearing aid algorithm is a multi-band loudness compensation based independent component analysis (ICA). The proposed algorithm was compared with a conventional spectral subtraction algorithm on behind-the-ear type hearing aid. The proposed algorithm successfully separated a target speech signal from background noise and from a mixture of the speech signals. The algorithms were compared each other by means of SNR. The average improvement of SNR by ICA based algorithm was 16.64dB, whereas spectral subtraction algorithm was 8.67dB. From the clinical tests, we concluded that our proposed algorithm would help hearing aid user to hear clearly a target speech in noisy conditions.