• Title/Summary/Keyword: headed studs

Search Result 38, Processing Time 0.024 seconds

Seismic design of connections between steel outrigger beams and reinforced concrete walls

  • Deason, Jeremy T.;Tunc, Gokhan;Shahrooz, Bahram M.
    • Steel and Composite Structures
    • /
    • v.1 no.3
    • /
    • pp.329-340
    • /
    • 2001
  • Cyclic response of "shear" connections between steel outrigger beams and reinforced concrete core walls is presented in this paper. The connections investigated in this paper consisted of a shear tab welded onto a plate that was connected to the core walls through multiple headed studs. The experimental data from six specimens point to a capacity larger than the design value. However, the mode of failure was through pullout of the embedded plate, or fracture of the weld between the studs and plate. Such brittle modes of failure need to be avoided through proper design. A capacity design method based on dissipating the input energy through yielding and fracture of the shear tab was developed. This approach requires a good understanding of the expected capacity of headed studs under combined gravity shear and cyclic axial load (tension and compression). A model was developed and verified against test results from six specimens. A specimen designed based on the proposed design methodology performed very well, and the connection did not fail until shear tab fractured after extensive yielding. The proposed design method is recommended for design of outrigger beam-wall connections.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • v.17 no.6
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.

Experimental analysis on steel and lightweight concrete composite beams

  • Valente, Isabel B.;Cruz, Paulo J.S.
    • Steel and Composite Structures
    • /
    • v.10 no.2
    • /
    • pp.169-185
    • /
    • 2010
  • The present work describes the experimental tests on steel and lightweight concrete composite beams performed at University of Minho, Portugal. The study involves tests on simply supported composite beams of 4.5 m span, with the same geometrical disposition, supports and materials. The geometrical configuration for the cross section and supports is identical for every beam, varying the shear connectors' distribution and the loading conditions. Headed studs are used to provide the connection between the steel profile and the concrete slab. The parameters in study are the stud disposition and the load distribution. The main objective is to describe the composite beams behaviour, focused on its connection, and to analyse the contribution of the different components to the beams load and deformation capacity. All the tests explored the beams maximum load and deformation capacity and different types of failure were observed.

Effect of local small diameter stud connectors on behavior of partially encased composite beams

  • Nguyen, Giang Bergerova;Machacek, Josef
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.251-266
    • /
    • 2016
  • The paper combines two distinct parts. First the behavior of welded headed studs with small diameters of 10 and 13 mm acting as shear connectors (which are not embraced in current standards) is studied. Based on standard push tests the load-slip relationships and strengths are evaluated. While the current standard (Eurocode 4 and AISC) formulas used for such studs give reasonable but too conservative strengths, less conservative and full load-slip rigidities are evaluated and recommended for a subsequent investigation or design. In the second part of the paper the partially encased beams under bending are analyzed. Following former experiments showing rather indistinct role of studs used for shear connection in such beams their role is studied. Numerical model employing ANSYS software is presented and validated using former experimental data. Subsequent parametric studies investigate the longitudinal shear between steel and concrete parts of the beams with respect to friction at the steel and concrete interface and contribution of studs with small diameters required predominantly for assembly stages (concreting). Substantial influence of the friction and effect of concrete confinement was observed with rather less noticeable contribution of the studs. Distribution of the longitudinal shear and its sharing between friction and studs is presented with concluding remarks.

Experimental and numerical study on static behavior of grouped large-headed studs embedded in UHPC

  • Hu, Yuqing;Zhao, Guotang;He, Zhiqi;Qi, Jianan;Wang, Jingquan
    • Steel and Composite Structures
    • /
    • v.36 no.1
    • /
    • pp.103-118
    • /
    • 2020
  • The static behavior of grouped large-headed studs (d = 30 mm) embedded in ultra-high performance concrete (UHPC) was investigated by conducting push-out tests and numerical analysis. In the push-out test, no splitting cracks were found in the UHPC slab, and the shank failure control the shear capacity, indicating the large-headed stud matches well with the mechanical properties of UHPC. Besides, it is found that the shear resistance of the stud embedded in UHPC is 11.4% higher than that embedded in normal strength concrete, indicating that the shear resistance was improved. Regarding the numerical analysis, the parametric study was conducted to investigate the influence of the concrete strength, aspect ratio of stud, stud diameter, and the spacing of stud in the direction of shear force on the shear performance of the large-headed stud. It is found that the stud diameter and stud spacing have an obvious influence on the shear resistance. Based on the test and numerical analysis results, a formula was established to predict the load-slip relationship. The comparison indicates that the predicted results agree well with the test results. To accurately predict the shear resistance of the stud embedded in UHPC, a design equation for shear strength is proposed. The ratio of the calculation results to the test results is 0.99.

Behaviour and design of bolted endplate joints between composite walls and steel beams

  • Li, Dongxu;Uy, Brian;Mo, Jun;Thai, Huu-Tai
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.33-47
    • /
    • 2022
  • This paper presents a finite element model for predicting the monotonic behaviour of bolted endplate joints connecting steel-concrete composite walls and steel beams. The demountable Hollo-bolts are utilised to facilitate the quick installation and dismantling for replacement and reuse. In the developed model, material and geometric nonlinearities were included. The accuracy of the developed model was assessed by comparing the numerical results with previous experimental tests on hollow/composite column-to-steel beam joints that incorporated endplates and Hollo-bolts. In particular, the Hollo-bolts were modelled with the expanded sleeves involved, and different material properties of the Hollo-bolt shank and sleeves were considered based on the information provided by the manufacture. The developed models, therefore, can be applied in the present study to simulate the wall-to-beam joints with similar structural components and characteristics. Based on the validated model, the authors herein compared the behaviour of wall-to-beam joints of two commonly utilised composite walling systems (Case 1: flat steel plates with headed studs; Case 2: lipped channel section with partition plates). Considering the ease of manufacturing, onsite erection and the pertinent costs, composite walling system with flat steel plates and conventional headed studs (Case 1) was the focus of present study. Specifically, additional headed studs were pre-welded inside the front wall plates to enhance the joint performance. On this basis, a series of parametric studies were conducted to assess the influences of five design parameters on the behaviour of bolted endplate wall-to-beam joints. The initial stiffness, plastic moment capacity, as well as the rotational capacity of the composite wall-to-beam joints based on the numerical analysis were further compared with the current design provision.

Modelling of headed stud in steel-precast composite beams

  • El-Lobody, Ehab;Lam, Dennis
    • Steel and Composite Structures
    • /
    • v.2 no.5
    • /
    • pp.355-378
    • /
    • 2002
  • Use of composite steel construction with precast hollow core slabs is now popular in the UK, but the present knowledge in shear capacity of the headed shear studs for this type of composite construction is very limited. Currently, all the information is based on the results obtained from experimental push-off tests. A finite element model to simulate the behaviour of headed stud shear connection in composite beam with precast hollow core slabs is described. The model is based on finite element method and takes into account the linear and non-linear behaviour of all the materials. The model has been validated against the test results, for which the accuracy of the model used is demonstrated. Parametric studies showing the effect of the change in transverse gap size, transverse reinforcement diameter and in-situ concrete strength on the shear connection capacity are presented.

Determination of shear stiffness for headed-stud shear connectors using energy balance approach

  • Ye, Huawen;Huang, Ruosen;Tang, Shiqing;Zhou, Yu;Liu, Jilin
    • Steel and Composite Structures
    • /
    • v.42 no.4
    • /
    • pp.477-487
    • /
    • 2022
  • The shear stiffness of headed-stud shear connectors has no unified definition due to the nonlinear characteristics of its load-slip relationship. A unified framework was firstly adopted to develop a general expression of shear load-slip equation for headed-stud shear connectors varying in a large parameter range based on both force and energy balance. The pre- and post-yield shear stiffness were then determined through bilinear idealization of proposed shear load-slip equation. An updated and carefully selected push-out test database of 157 stud shear connectors, conducting on studs 13~30mm in diameter and on concretes 30~180 MPa in cubic compressive strength, was used for model regression and sensitivity analysis of shear stiffness. An empirical calculation model was also established for the stud shear stiffness. Compared with the previous models through statistical analysis, the proposed model demonstrates a better performance to predict the shear load-slip response and stiffness of the stud shear connectors.

Study on Fire Performance of Stud Connectors (스터드커넥터의 내화성능에 관한 연구)

  • Kim, Sung-Bae;Han, Sang-Hoon;Choi, Seng-Kwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2009
  • This research aims to conduct a pilot study for the in-fire performance of headed studs, commonly used in composite structures over the world. The robustness of the shear studs in fire appears to be a key element to govern the composite behaviour after a sudden local instability developed in structures such as trusses and cellular beams. In order to experimentally evaluate the residual strength of studs in fire, the standard push-out test was modified for a half of the original set-up to be equipped with a furnace. The adjustments allow the steel section to have a 3-sided exposure against fire. Under the Standard ISO fire, the modified push-out tests under loading were conducted to identify the failure mechanism of the studs in relation to temperature developments.