• 제목/요약/키워드: head of an investigative body

검색결과 4건 처리시간 0.022초

High-Resolution Numerical Simulation of Respiration-Induced Dynamic B0 Shift in the Head in High-Field MRI

  • Lee, So-Hee;Barg, Ji-Seong;Yeo, Seok-Jin;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.38-45
    • /
    • 2019
  • Purpose: To demonstrate the high-resolution numerical simulation of the respiration-induced dynamic $B_0$ shift in the head using generalized susceptibility voxel convolution (gSVC). Materials and Methods: Previous dynamic $B_0$ simulation research has been limited to low-resolution numerical models due to the large computational demands of conventional Fourier-based $B_0$ calculation methods. Here, we show that a recently-proposed gSVC method can simulate dynamic $B_0$ maps from a realistic breathing human body model with high spatiotemporal resolution in a time-efficient manner. For a human body model, we used the Extended Cardiac And Torso (XCAT) phantom originally developed for computed tomography. The spatial resolution (voxel size) was kept isotropic and varied from 1 to 10 mm. We calculated $B_0$ maps in the brain of the model at 10 equally spaced points in a respiration cycle and analyzed the spatial gradients of each of them. The results were compared with experimental measurements in the literature. Results: The simulation predicted a maximum temporal variation of the $B_0$ shift in the brain of about 7 Hz at 7T. The magnitudes of the respiration-induced $B_0$ gradient in the x (right/left), y (anterior/posterior), and z (head/feet) directions determined by volumetric linear fitting, were < 0.01 Hz/cm, 0.18 Hz/cm, and 0.26 Hz/cm, respectively. These compared favorably with previous reports. We found that simulation voxel sizes greater than 5 mm can produce unreliable results. Conclusion: We have presented an efficient simulation framework for respiration-induced $B_0$ variation in the head. The method can be used to predict $B_0$ shifts with high spatiotemporal resolution under different breathing conditions and aid in the design of dynamic $B_0$ compensation strategies.

Russian and Foreign Experience in Implementing Departmental Control and Prosecutor's Supervision when Verifying Crime Reports

  • Ivanov, Dmitriy Aleksandrovich;Moskovtseva, Kristina Andreevna;Bui, Thien Thuong;Sheveleva, Kseniya Vladimirovna;Vetskaya, Svetlana Anatolyevna
    • International Journal of Computer Science & Network Security
    • /
    • 제22권8호
    • /
    • pp.299-303
    • /
    • 2022
  • The article examines the stage of verification of a crime report from the standpoint of the need for its legislative regulation. Moreover, it investigates the international experience in this field. The existing procedural models are described in detail on the example of the neighboring and faraway countries. An analysis of the provisions of the current criminal procedure law of Russia and foreign experience allowed the authors to identify existing problems in the implementation of departmental control and prosecutorial supervision at the stage of verifying a crime report. The aim of the study is to develop theoretical provisions and recommendations regarding the implementation of departmental procedural control and prosecutorial supervision over the activities of the investigator during the verification of reports of crimes, based on the study of experience, both in Russia and in a number of countries of the near and far abroad, which could find their reflection in law enforcement practice, as well as aimed at improving the current criminal procedure legislation. The authors substantiated the theory that a detailed examination of the foreign procedural foundations of checking a crime report will allow us to form the most suitable model for checking a crime report for our state, taking into account all possible features and successfully implement it into the current criminal procedural law of the Russian Federation.

MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석 (Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI)

  • 이항로;한재용;조민형;임창환;정현교;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.108-115
    • /
    • 2003
  • 목적 : MRI를 촬영하면서 동시에 측정한 뇌전도 신호에 가장 크게 영향을 미치는 것은 경사자계 유발 잡음이다. MRI와 동시에 측정한 뇌전도 신호에서 전류원 국지화를 수행할 때, 경사자계 유발 잡음이 미치는 영향을 분석하고자 한다. 대상 및 방법 : 사람의 머리와 유사하게 만든 뇌전도 팬텀과 MR compatible 뇌전도 측정시스템, 그리고 3.0 Tesla MRI 시스템을 실험에 사용하였다. 3.0 Tesla MRI 시스템 안에 전류원이 설치되어 있는 뇌전도 팬텀을 놓고, EPI 촬영을 하는 동안 뇌전도 신호를 측정하였다. 경사자계의 세기와 전류원의 위치를 조절하면서 뇌전도 신호 측정을 하였고, 측정된 뇌전도 신호에 대하여 전류원 국지화를 수행할 때 나타나는 국지화 오차를 평가하였다. 결과 : 경사자계 유발잡음에 의한 국지화 오차는 경사자계의 세기와 전류원의 위치에 따라 변화하는 것을 관찰하였다. 또한 경사자계 유발잡음이 Gaussian 잡음보다 전류원 국지화에 미치는 영향이 큰 것을 관찰하였으며, 경사자계 유발 잡음의 전력이 뇌전도 신호 전력의 $10\%$ 이하일 때는 전류원 국지화에 미치는 영향이 미미함을 관찰하였다. 결론 : 경사자계 유발 잡음 전력을 뇌전도 신호 전력의 $10\%$ 이하로 줄인다면 MRI를 하면서 동시에 측정한 뇌전도 신호로도 전류원 국지화를 할 수 있음을 알 수 있었다.

  • PDF

3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상 (High-resolution Spiral-scan Imaging at 3 Tesla MRI)

  • 김판기;임종우;강승원;조상흠;전수열;임헌진;박호종;오승준;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.108-116
    • /
    • 2006
  • 목적 : 3.0 Tesla 고 자장에서 고 해상도 나선주사영상을 수행하였다. 나선주사영상은 초고속 영상기법의 하나로서, Echo Planar Imaging(EPI)에 비하여 eddy current 가 작게 발생하고, 경사자계 파형의 기울기가 완만하여 상대적으로 낮은 slew rate 를 가진 경사자계시스템으로 구현이 가능한 장점이 있다. 또한 고 자장 영상에서 고속스핀에코(Fast Spin Echo: FSE) 등의 rf 에코 기반의 고속영상방법에서 심각하게 대두되는 SAR 문제가 근원적으로 발생하지 않는 장점이 있어 고 자장에서의 초고속영상방법으로 주목을 받고 있다. 본 연구에서는 3.0 Tesla 에서 나선주사방식으로 고 해상도 영상을 얻어 고 자장 MRI에서 나선주사영상기법의 다양한 응용 가능성을 살펴보고자 한다. 대상 및 방법 : 3 Tesla 전신 자기 공명 영상 시스템에서 다양한 해상도의 나선주사영상 방법을 개발하였다. 고차(higher-order) shimming 을 통하여 영상의 화질을 개선하였고, 해상도에 맞게 interleaves 수를 조절하였다. 스핀에코 와 gradient에코 기반 나선주사영상방법을 구현하였고, 에코 time 과 repetition time, rf 회전 각도를 조절하여 영상의 대조도(contrast)와 신호대잡음비를 조절하였다. 결과 : 3 Tesla 전신 자기 공명 영상 시스템에서 나선 주사 방법을 이용하여 다양한 해상도의 영상을 얻었다. 고 자장에서 주 자장의 불균일도(inhomogeneity) 의 절대 크기가 커지기 때문에 이를 줄이기 위한 shimming 이 더욱 중요해진다. 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구하여 spherical harmonics 분석으로 고차 shimming을 하였다. 팬텀과 in-vivo 두부 영상에서 single shot 나선주사 영상으로 $100{\times}100$ 정도의 영상과 6-12 정도의 interleaves 를 적용하여 $256{\times}256$ 의 고 해상도 영상을 얻을 수 있었다. 결론 : 신호대잡음비의 향상과 스펙트럼의 분리, 뇌기능영상에서 BOLD 효과 향상 등으로 고자장 영상에 대한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다.

  • PDF