• Title/Summary/Keyword: hazard levels

Search Result 436, Processing Time 0.022 seconds

Establishment of Integrated Health Evaluation Criteria for Coastal Aquaculture System (살포식 패류 양식어장 건강도 평가기준 설정)

  • Young-Shin Go;Dong-Hun Lee;Young-Jae Lee;Won-Chan Lee;Un-Ki Hwang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.4
    • /
    • pp.462-472
    • /
    • 2023
  • We investigated the physio-chemical and geochemical parameters in the spraying shellfish aquacultures (Yeoja and Gangjin Bay) to establish the systematic strategy for effective environmental management. Spatial variation of each parameter showed partially significant difference (P<0.05) between Yeoja and Ganjin Bay, inferring the discriminative progress (i.e., accumulation and degradation) of the autochthonous organic matter within the aquaculture environments. We additionally integrated various properties (e.g., water/sediment quality, natural hazard, and biological health) which may affect the biological growth within the aquaculture habitats based on the biogeochemical cycles related to environmental components and aquaculture species. We used a screening approach (i.e., one out-all out; OOAO) which can permit the assessment of the health levels of aquaculture species, the scoring for other parameters (seawater, sediment, and natural hazard) as three levels (excellent, moderate and poor) depending on the complex interactive properties occurring in the aquaculture environments. Actual, discriminative scores obtained via our case studies may confirm that these stepwise processes are effectively evaluated for optimal health conditions within the aquaculture habitats. Thus, this approach may provide valuable insights for effective environmental management and sustainable growth of aquaculture operation.

Objective Quantitation of EGFR Protein Levels using Quantitative Dot Blot Method for the Prognosis of Gastric Cancer Patients

  • Xin, Lei;Tang, Fangrong;Song, Bo;Yang, Maozhou;Zhang, Jiandi
    • Journal of Gastric Cancer
    • /
    • v.21 no.4
    • /
    • pp.335-351
    • /
    • 2021
  • Purpose: An underlying factor for the failure of several clinical trials of anti-epidermal growth factor receptor (EGFR) therapies is the lack of an effective method to identify patients who overexpress EGFR protein. The quantitative dot blot method (QDB) was used to measure EGFR protein levels objectively, absolutely, and quantitatively. Its feasibility was evaluated for the prognosis of overall survival (OS) of patients with gastric cancer. Materials and Methods: Slices of 2×5 ㎛ from formalin-fixed paraffin-embedded gastric cancer specimens were used to extract total tissue lysates for QDB measurement. Absolutely quantitated EGFR protein levels were used for the Kaplan-Meier OS analysis. Results: EGFR protein levels ranged from 0 to 772.6 pmol/g (n=246) for all gastric cancer patients. A poor correlation was observed between quantitated EGFR levels and immunohistochemistry scores with ρ=0.024 and P=0.717 in Spearman's correlation analysis. EGFR was identified as an independent negative prognostic biomarker for gastric cancer patients only through absolute quantitation, with a hazard ratio of 1.92 (95% confidence interval, 1.05-3.53; P=0.034) in multivariate Cox regression OS analysis. A cutoff of 208 pmol/g was proposed to stratify patients with a 3-year survival probability of 44% for patients with EGFR levels above the cutoff versus 68% for those below the cutoff based on Kaplan-Meier OS analysis (log rank test, P=0.002). Conclusions: A QDB-based assay was developed for gastric cancer specimens to measure EGFR protein levels absolutely, quantitatively, and objectively. This assay should facilitate clinical trials aimed at evaluation of anti-EGFR therapies retrospectively and prospectively for gastric cancer.

Hazard Analysis of Tomato Farms at the Growing Stage for the Establishment of the Good Agricultural Practices (GAP) (토마토 농산물우수관리제도(GAP)모델 확립을 위한 재배단계 위해분석)

  • Park, Su-Hee;Kwon, Woo-Hyun;Heo, Rok-Won;Kim, Kyeong-Yeol;Shim, Won-Bo;Shim, Sang-In;Chung, Duck-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.152-160
    • /
    • 2012
  • The objective of this study was to analyze hazards for the growing stage of 6 tomato farms (A, B, C; soli farms, D, E, F; Nutriculture farms) located in Gyeongsangnam-do to establish the good agricultural practices (GAP). A total of 144 samples for analyzing hazards collected from cultivation environments (irrigation water, soil, nutrient solution, and air) and personal hygiene (hands, gloves, and cloths) were assessed for biological (sanitary indications and major food borne pathogens) and chemical hazards (heavy metals). Total bacteria, coliform, and fungi were detected at levels of 0.2-7.2, 0.0-6.1, and 0.0-5.4 log CFU/g, mL, hand or 100 $cm^2$, respectively. Escherichia coli were only detected in the soil sample from B farm. In case of pathogens, Bacillus cereus was detected at levels of 0.0-4.4 log CFU/(g, mL, hand or 100 $cm^2$), whereas Staphylococuus aureus, Listeria monocytogenes, E. coli O157, and Salmonella spp. were not detected in all samples. Heavy metals as a chemical hazard were detected in soil and irrigation water, but levels of them were lower than the permit limit. In conclusion, chemical hazard levels complied with GAP criteria, but biological hazards at the growing stage of tomato farms were confirmed. Therefore a proper management to prevent microbial contamination is needed.

Microbial Hazard Analysis of Manufacturing Processes for Starch Noodle (당면의 제조공정별 미생물학적 위해요소 분석)

  • Cheon, Jin-Young;Yang, Ji Hye;Kim, Min Jeong;Lee, Su-Mi;Cha, Myeonghwa;Park, Ki-Hwan;Ryu, Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.420-426
    • /
    • 2012
  • The purpose of this study was to identify control points through microbiological hazard analysis in the manufacturing processes of starch noodles. Samples were collected from the ingredients, manufacturing processes, equipment and environment. Microbiological hazard assessments were performed using aerobic plate counts (APC), Enterobacteriaceae (EB), E. coli and five pathogens including B. cereus, E. coli O157:H7, L. monocytogenes, Salmonella spp., and S. aureus. The APC levels in raw materials were from 2.12 to 3.83 log CFU/g. The contamination levels after kneading were 4.31 log CFU/g for APCs and 2.88 log CFU/g for EB counts. APCs decreased to 1.63 log CFU/g and EB were not detected after gelatinization, but their levels slightly increased upon cooling, cutting, ripening, freezing, thawing, and separating. The reuse of cooling and coating water would be a critical source of microbial increase after cooling. After drying, APCs and EB counts decreased to 5.05 log CFU/g and 2.74 log CFU/g, respectively, and the levels were maintained to final products. These results suggest that the cooling process is a critical control point for microbiological safety, and the cooling water should be treated and controlled to prevent cross contamination by pre-requisite program.

Evaluation of the HACCP System on Microbiological Hazard during Dressing Production (드레싱 제조업체의 HACCP 시스템 적용을 위한 미생물학적 위해도 평가)

  • Kwon, Sang-Chul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.457-463
    • /
    • 2013
  • The purpose of this study was to apply the Hazard Analysis Critical Control Point (HACCP) system to the production of dressing. The hazard analysis examined the main materials, industrial water, microbial evaluation, and airborne microorganisms of each working area, as well as the pathogenic microbial contamination risk. The survey was conducted at SJ Company in Jincheon (Chungchengbuk-do), Korea for 30 days from April 1, 2012 to April 30, 2012. The results showed that raw material microorganisms had a total plate count in industrial water below $3.00{\times}10$ CFU/mL in working room I, working room II, the packing room, washing water, and the inspection room for five times in each place. During dressing production (including heat treatment and mixing), general bacteria were detected at an average of $3{\times}10$ CFU/mL, but yeast, mold, and pathogenic bacteria were not detected. Airborne microbiological evaluation (for total plate count, yeast, and mold) found levels below the legal limit at each working area. While workers were positive for microbes in total plate counts, coliform and Staphylococcus aureus were not detected. In conclusion, standards for hygienic management should be established to prevent and decrease hazards, such as general bacteria and pathogenic microorganisms (for example, E. coli, B. cereus, Listeria spp, Salmonella spp, Staph. aureus, Clostridium perfringens, yeast, and mold), and to found critical limits for microorganisms with an HACCP system.

A Study on Health Impact Assessment and Emissions Reduction System Using AERMOD (AERMOD를 활용한 건강위해성평가 및 배출저감제도에 관한 연구)

  • Seong-Su Park;Duk-Han Kim;Hong-Kwan Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.93-105
    • /
    • 2024
  • Purpose: This study aims to quantitatively determine the impact on nearby risidents by selecting the amount of chemicals emitted from the workplace among the substances subject to the chemical emission plan and predicting the concentration with the atmospheric diffusion program. Method: The selection of research materials considered half-life, toxicity, and the presence or absence of available monitoring station data. The areas discharged from the materials to be studied were selected as the areas to be studied, and four areas with floating populations were selected to evaluate health risks. Result: AERMOD was executed after conducting terrain and meteorological processing to obtain predicted concentrations. The health hazard assessment results indicated that only dichloromethane exceeded the threshold for children, while tetrachloroethylene and chloroform appeared at levels that cannot be ignored for both children and adults. Conclusion: Currently, in the domestic context, health hazard assessments are conducted based on the regulations outlined in the "Environmental Health Act" where if the hazard index exceeds a certain threshold, it is considered to pose a health risk. The anticipated expansion of the list of substances subject to the chemical discharge plan to 415 types by 2030 suggests the need for efficient management within workplaces. In instances where the hazard index surpasses the threshold in health hazard assessments, it is judged that effective chemical management can be achieved by prioritizing based on considerations of background concentration and predicted concentration through atmospheric dispersion modeling.

On the Hazard Identification Methods for the Realization of Functional Safety Standards (기능안전 표준들의 구현을 위한 기능 중심의 위험원 식별 방법)

  • Jung, Ho Jeon;Lee, Jae Chon;Oh, Seong Keun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.105-112
    • /
    • 2013
  • To meet the growing needs from a variety of stakeholders, the development of modern systems is getting more complex and thus, the systems failure in the actual operations can potentially become more serious. This is why several international or military standards on systems safety have been published. In spite of the importance of meeting those standards such as IEC 61508 and ISO 26262 in the systems development, the associated practical methods seem deficient since those standards do not provide them. The objective of this paper is to present a method to identify potential hazards in fulfilling the requirements of the safety standards. In particular, the approach taken here is based on applying the functional analysis that covers several levels of the system under development. Note, however, that in the most of the conventional methods for hazards identification, the analysis has been focused on the failure at or underneath the component level of the system. The hazards identification method in this paper would cover the level up to the system by utilizing the functions-oriented approach. The case study of the safety enhancement for locomotive cabs is also discussed.

Minimum loading requirements for areas of low seismicity

  • Lam, Nelson T.K.;Tsang, Hing-Ho;Lumantarna, Elisa;Wilson, John L.
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.539-561
    • /
    • 2016
  • The rate of occurrence of intraplate earthquake events has been surveyed around the globe to ascertain the average level of intraplate seismic activities on land. Elastic response spectra corresponding to various levels of averaged (uniform) seismicity for a return period of 2475 years have then been derived along with modifying factors that can be used to infer ground motion and spectral response parameters for other return period values. Estimates derived from the assumption of uniform seismicity are intended to identify the minimum level of design seismic hazard in intraplate regions. The probabilistic seismic hazard assessment presented in the paper involved the use of ground motion models that have been developed for regions of different tectonic and crustal classifications. The proposed minimum earthquake loading model is illustrated by the case study of Peninsular Malaysia which has been identified with a minimum effective peak ground acceleration (EPGA) of 0.1 g for a return period of 2475 years, or 0.07 g for a notional return period of 475 years.

Seismic Performance of Internally Confined Hollow RC Column with Corrugated Steel Tube (파형강관 내부 구속 중공 철근 콘크리트 기둥의 내진 성능)

  • Han, Taek-Hee;Kim, Jong-Min;Kang, Jun-Suk;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • A column test was performed far a new-type column with a quasi static test. An internally confined hollow reinforced concrete column with a corrugated steel tube (ICH RC-CT column) was tested to evaluate its seismic performance. And also, a general solid RC column was tested fur the comparison. The test was performed as planned drift levels. The lateral displacements and the lateral loads of column specimens were measured during tests. From the test results, the ICH RC-CT column showed smaller energy absorbing capacity than a solid RC column but showed the almost equal energy ductility and equivalent viscous damping ratio to those of the solid RC column.

Performance-based earthquake engineering methodology for seismic analysis of nuclear cable tray system

  • Huang, Baofeng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2396-2406
    • /
    • 2021
  • The Pacific Earthquake Engineering Research (PEER) Center has been developing a performance-based earthquake engineering (PBEE) methodology, which is based on explicit determination of performance, e.g., monetary losses, in a probabilistic manner where uncertainties in earthquake ground motion, structural response, damage estimation, and losses are explicitly considered. To carry out the PEER PBEE procedure for a component of the nuclear power plant (NPP) such as the cable tray system, hazard curve and spectra were defined for two hazard levels of the ground motions, namely, operation basis earthquake, and safe shutdown earthquake. Accordingly, two sets of spectral compatible ground motions were selected for dynamic analysis of the cable tray system. In general, the PBEE analysis of the cable tray in NPP was introduced where the resulting floor motions from the time history analysis (THA) of the NPP structure should be used as the input motion to the cable tray. However, for simplicity, a finite element model of the cable tray was developed for THA under the effect of the selected ground motions. Based on the structural analysis results, fragility curves were generated in terms of specific engineering demand parameters. Loss analysis was performed considering monetary losses corresponding to the predefined damage states. Then, overall losses were evaluated for different damage groups using the PEER PBEE methodology.