• 제목/요약/키워드: harmonic response

검색결과 556건 처리시간 0.023초

Beating phenomena in spacecraft sine testing and an attempt to include the sine sweep rate effect in the test-prediction

  • Nali, Pietro;Bettacchioli, Alain
    • Advances in aircraft and spacecraft science
    • /
    • 제3권2호
    • /
    • pp.197-209
    • /
    • 2016
  • The Spacecraft (S/C) numerical sine test-predictions are usually performed through Finite Element Method (FEM) Frequency Response Analysis (FRA), that is the hypothesis of steady-state responses to harmonic excitation to the S/C base is made. In the test practice, the responses are transient and may be significantly different from those predicted through FRA. One of the most significant causes of discrepancy between prediction and test consists in the beating phenomena. After a brief overview of the topic, the typical causes of beating are described in the first part of the paper. Subsequently, focus is made on the sine sweep rate effect, which often leads to have beatings after the resonance of weakly damped modes. In this work, the approach illustrated in the literature for calculating the sine sweep rate effect in the case of Single-Degree-Of-Freedom (SDOF) oscillators is extended to Multi-Degrees-Of-Freedom (MDOF) systems, with the aim of increasing the accuracy of the numerical sine test-predictions. Assumptions and limitations of the proposed methodology are detailed along the paper. Several assessments with test results are discussed and commented.

공기 가진력에 의한 팬 블레이드 구조 안정성 평가에 관한 연구 (A study on the Structural Stability about the Fan Blade by the Air Excited Forces.)

  • 정규강;김경희;조생현
    • 한국추진공학회지
    • /
    • 제4권1호
    • /
    • pp.93-101
    • /
    • 2000
  • 엔진 운용 중에 유로(flow Path)에 놓여 있는 팬 블레이드(blade)들은 많은 외부하중에 노출되어 있어서 고주기 피로(high cycle fatigue)에 의한 피로 파괴의 위험성이 크다. 그 중 가장 중요하게 평가되는 것이 주기적인 가진력에 의한 공진 현상과 그에 따른 피로파괴 가능성이다. 본 논문에서는 유동장 (flow field)이 지주(struts)에 의해 영향을 받게 되고, 이러한 유동장의 분포가 지주 후방에서 주기함수 형태로 팬 블레이드를 가진 할 때, 팬 블레이드에서의 진동 응답 특성과 구조적인 안정성을 평가하였다. 팬 블레이드의 피로강도를 시험적으로 평가하고, 팬 블레이드 전방 지주에 의한 공기 가진력을 가정하여 유한 요소 해석을 통한 구조적 안정성을 평가하였다. 그리고 엔진 시험에서 측정된 서지 압력 하중을 팬 블레이드의 유한요소 모델에 적용하여 구조적 영향을 평가함으로써 팬 블레이드의 구조적인 안정성을 확인하였다.

  • PDF

Improving a current method for predicting walking-induced floor vibration

  • Nguyen, T.H.;Gad, E.F.;Wilson, J.L.;Haritos, N.
    • Steel and Composite Structures
    • /
    • 제13권2호
    • /
    • pp.139-155
    • /
    • 2012
  • Serviceability rather than strength is the most critical design requirement for vibration-vulnerable floor constructions. Annoying vibrations due to normal walking activity have been observed more frequently on long-span lightweight floor systems in office and commercial retail buildings, raising the need for the development of floor vibration design procedures. This paper highlights some limitations of one of the most commonly used guidelines AISC/CISC DG11, and proposes improvements to this method. Design charts and approximate closed form formulas to estimate the walking response are developed in which various factors relating to the dynamic characteristics of both the floor and the excitation are considered. The accuracy of the proposed formulas and other proposals found in the literature is examined. The proposed modifications would be significant, especially with long-span floors where vibration levels may be underestimated by the current design procedure. The application of the proposed prediction method is illustrated by worked examples that reveal a good agreement with results obtained from finite element analyses and experiments. The presented work would enhance the accuracy and maintain the simplicity and convenience of the design guideline.

박테리아 셀룰로오스 기반 생체모방 작동기 개발 및 평가 (Development and Evaluation of the Biomimetic Actuator based on Bacterial Cellulose)

  • 김시습;기창두
    • 한국정밀공학회지
    • /
    • 제29권3호
    • /
    • pp.302-306
    • /
    • 2012
  • Bacterial cellulose based actuator with large displacement was developed for biomimetic robots. Bacterial cellulose has 3D nanostructure with high porosity which was composed of the nanofibers. Freeze dried bacterial cellulose was dipped into ionic liquid solution such as 1-butyl-3-methylimidazolium(BMIMCl) to enhance the actuation performance due to increase the ionexchange capacity and ionic conductivity. And Poly(3,4-ethylenedioxythiophene)-poly (styrnenesulfonate)(PEDOT:PSS) was used for the electrodes of both side of bacterial cellulose actuator by dipping and drying method. The FT-IR and XRD were conducted to examine the electrochemical changes of developed bacterial cellulose actuator. The biomimetic caudal fin was designed using bacterial cellulose actuator and PDMS to verify the possibility for biomimetic robot. The step and harmonic response were conducted to evaluate the performance of developed biomimetic actuator.

FACTS 적용을 위한 직렬형 멀티레벨 전압형 인버터를 사용한 1MVar STATCON의 새로운 스위칭기법 (Novel Switching Strategy of 1MVar STATCON using Cascade Multilevel Voltage Source Inverter for FACTS Application)

  • 민완기;민준기;최재호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.691-700
    • /
    • 1999
  • This paper proposes a novel switching strategy of 1Mvar STATCON using cascade multilevel H-bridge inverter(HBI) for FACTS application. To control the reactive power instantaneously, the d-q dynamic system model is described and analyzed. A single pulse pattern based on the SHEM(Selective Harmonic Elimination Method) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is presented to adjust the DC voltage of each inverter capacitor at the same value. So the voltage unbalance problem between separately DC bus voltage is improved by using the proposed switching scheme. As a result, the presented inverter configuration not only reduces the system complexity by eliminating the isolation at the AC input side transformer but also improves the dynamic response to the step change of reactive power.

  • PDF

Robust Deadbeat Current Control Method for Three-Phase Voltage-Source Active Power Filter

  • Nishida, Katsumi;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.102-111
    • /
    • 2004
  • This paper is concerned with a deadbeat current control implementation of shunt-type three-phase active power filter (APF). Although the one-dimensional deadbeat control method can attain time-optimal response of APF compensating current, one sampling period is actually required fur its settling time. This delay is a serious drawback for this control technique. To cancel such a delay and one more delay caused by DSP execution time, the desired APF compensating current has to be predicted two sampling periods ahead. Therefore an adaptive predictor is adopted for the purpose of both predicting the control error of two sampling periods ahead and bringing the robustness to the deadbeat current control system. By adding the adaptive predictor output as an adjustment term to the reference value of half a source voltage period before, settling time is made short in a transient state. On the other hand, in a steady state, THD (total harmonic distortion) of the utility grid side AC source current can be reduced as much as possible, compared to the case that ideal identification of controlled system could be made.

Novel Control Method for a Hybrid Active Power Filter with Injection Circuit Using a Hybrid Fuzzy Controller

  • Chau, MinhThuyen;Luo, An;Shuai, Zhikang;Ma, Fujun;Xie, Ning;Chau, VanBao
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.800-812
    • /
    • 2012
  • This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closed-control loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.

Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) for quasi Z-Source Inverters based on a Current Observer

  • Bakeer, Abualkasim;Ismeil, Mohamed A.;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.610-620
    • /
    • 2017
  • The Finite Control Set-Model Predictive Controller (FCS-MPC) for quasi Z-Source Inverters (qZSIs) is designed to reduce the number of sensors by proposing a current observer for the inductor current. Unlike the traditional FCS-MPC algorithm, the proposed model removes the inductor current sensor and observes the inductor current value based on the deposited prior optimized state as well as the capacitor voltage during this state. The proposed observer has been validated versus a typical MPC. Then, a comparative study between the proposed Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) and a linear PID controller is provided under the same operating conditions. This study demonstrates that the dynamic response of the control objectives by MFCS-MPC is faster than that of the PID. On the other hand, the PID controller has a lower Total Harmonic Distortion (THD) when compared to the MFCS-MPC at the same average switching. Experimental results validate both methods using a DSP F28335.

지반특성에 따른 동조질량감쇠기의 지진응답특성 및 최적설계변수 (Investigation on Seismic-Response Characteristics and Optimal Design Parameters of Tuned Mass Damper Considering Site Effects)

  • 강경수
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5306-5313
    • /
    • 2011
  • 기존 동조질량감쇠기의 최적설계변수에 관한 연구는 풍하중과 같은 조화하중을 받는 구조물을 대상으로 연구가 수행되었다. 본 연구에서는 수치해석을 통하여 지진하중이 작용하는 건축물에 설치되는 동조질량감쇠기의 최적 감쇠비와 동조진동수비를 구하였다. 지반특성을 단단한 지반, 연약지반, 단층 근처 지반으로 분류하고, 이들 지반특성을 고려한 수치해석을 통해 구한 동조질량감쇠기의 설계변수를 기존 연구 결과와 비교하였다. 수치해석결과 본 연구로부터 구해진 동조질량감쇠기의 설계변수값을 적용한 경우 지진하중에 의한 응답제어에 기존 연구를 통해 얻어진 변수값을 적용한 경우에 비해 더 나은 제어효과를 얻을 수 있음을 알 수 있었다.

Study on a Novel Switching Pattern Current Control Scheme Applied to Three-Phase Voltage-Source Converters

  • Zhao, Hongyan;Li, Yan;Zheng, Trillion Q.
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1563-1576
    • /
    • 2017
  • This paper presents a novel switching pattern current control (SP-CC) scheme, which is applied in three-phase voltage-source converters (VSCs). This scheme can select the optimal output switching pattern (SP) by referring the basic principle of space vector modulation (SVM). Moreover, SP-CC is a method without a carrier wave. Thus, the implementation process is concise and easy. When compared with the conventional hysteresis current control (C-HCC) and the space vector-based hysteresis current control (SV-HCC), the SP-CC has the performances of faster dynamic response of C-HCC and less switching number (SN) of SV-HCC. In addition, it has less harmonic contents in the three-phase current, along with a lower switching loss and a higher efficiency. Moreover, the hysteresis bandwidth and Clarke conversion are not required in the SP-CC. The effectiveness of the presented SP-CC is verified by simulation and experimental test results. In addition, the advantages of the SP-CC, when compared with the C-HCC and SV-HCC, are verified as well.