• Title/Summary/Keyword: harmonic performance.

Search Result 838, Processing Time 0.026 seconds

Acoustic Sources Localization in 3D Using Multiple Spherical Arrays

  • Wang, Fangzhou;Pan, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.759-768
    • /
    • 2016
  • Direction of arrival (DOA) estimation of multiple sources using sensor arrays has been widely studied in the last few decades, particularly, the spherical harmonic analysis utilizing a spherical array. Both the number of sensors on the aperture and size of the sphere can affect the estimation accuracy dramatically. However, those two factors are conflicted to each other in a single spherical array. In this paper, a multiple spherical arrays structure is proposed to provide an alternative design to the traditional single spherical array for the spherical harmonic decomposition, to obtain better localization performance. The new structure consists of several identical spheres in a given area, and the microphones are placed identically on each sphere. The spherical harmonic analysis algorithm using the new multiple array structure for the problem of multiple acoustic sources localization is presented. Simulation results show that the multiple spherical arrays can provide a more accurate direction of arrival (DOA) estimation for the multiple sources than that of a single spherical array, distinguish several adjacent sources more efficiently, and reduce the number of microphones on each sphere without decreasing its’ estimation accuracy.

A Study on the Intelligent Electronic Device for Non-Linear Loads (비선형 부하에 적용이 가능한 IED에 관한 연구)

  • 박종찬;김병진;김수곤;전희종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.381-388
    • /
    • 2003
  • In this paper, the IED(Intelligent Electronic Devices) with the consideration of harmonic problems is discussed, With significant development of power electronics technology, the proliferation of a nonlinear load has more deteriorated power quality, As continuous harmonic current makes for a shortening lifetime, overheat and abnormal operation, it should be considered to improve these problems. However, the conventional digital protective relay which eliminates harmonic elements with orthogonal filter has a defect on actually implementation. The prototype IED is constructed with Digital Signal Processor(TMS320C32) and Complex Programmable Logic Device. According to the experiment and simulation results, it is proved that the proposed system has good performance of measuring harmonic factors and protecting electrical equipment.

An Iterative Technique for Real-Time Tracking of Power System Harmonics

  • Sidhu, T.S.;Zadeh, M.R.D.;Pooranalingam, P.J.;Oh, Yong-Taek
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.319-327
    • /
    • 2011
  • An iterative technique based on orthogonal filters and frequency tracking is proposed to estimate harmonic components in power systems. The technique uses frequency interpolation to estimate fundamental frequency and harmonics when the nominal frequency of the signal is a non-integer value. Due to the number of computations involved during the generation of filter coefficients, an offline computation is suggested. Beneficial features of the proposed technique include fixed sampling rate and fixed data window size. The performance of the proposed technique is examined by simulating different power system operating conditions and evaluating the data from these simulations. A technique based on Fast Fourier Transform is also used to estimate the harmonic components for all the simulated signals. These estimates are compared with those obtained from the proposed technique. Results show that the proposed technique can converge to the accurate fundamental frequency and therefore, provide accurate harmonic components even when the fundamental frequency is not equal to the nominal frequency.

Analysis of Surface Tracking of Micro and Nano Size Alumina Filled Silicone Rubber for High Voltage AC Transmission

  • Loganathan, N.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.345-353
    • /
    • 2013
  • This paper discusses the experimental results in an effort to understand the tracking and erosion resistance of the micro and nano size $Al_2O_3$ filled silicone rubber (SIR) material which has been studied under the AC voltages, with ammonium chloride as a contaminant, as per IEC 60587 test procedures. The characteristic changes in the tracking resistance of the micro and nano size filled specimens were analyzed through leakage current measurement and the eroded masses were used to evaluate the relative erosion and tracking resistance of the composites. The fundamental, third and fifth harmonic of the leakage current during the tracking study were analyzed using moving average current technique. It was observed that the harmonic components of leakage current show good correlation with the tracking and erosion resistance of the material. The thermogravimetry-derivative thermo gravimetric (TG-DTG) studies were performed to understand the thermal degradation of the composites. The physical and chemical studies were carried out by using scanning electron microscope (SEM), Energy Dispersive X-ray analysis (EDAX) and Fourier Transform Infra-red (FTIR) Spectroscopy. The obtained result indicated that the performance of nano filled SIR was better than the micro filled SIR material when the % wt. of filler increased.

Enhanced Variable On-time Control of Critical Conduction Mode Boost Power Factor Correction Converters

  • Kim, Jung-Won;Yi, Je-Hyun;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.890-898
    • /
    • 2014
  • Critical conduction mode boost power factor correction converters operating at the boundary of continuous conduction mode and discontinuous conduction mode have been widely used for power applications lower than 300W. This paper proposes an enhanced variable on-time control method for the critical conduction mode boost PFC converter to improve the total harmonic distortion characteristic. The inductor current, which varies according to the input voltage, is analyzed in detail and the optimal on-time is obtained to minimize the total harmonic distortion with a digital controller using a TMS320F28335. The switch on-time varies according to the input voltage based on the computed optimal on-time. The performance of the proposed control method is verified by a 100W PFC converter. It is shown that the optimized on-time reduces the total harmonic distortion about 52% (from 10.48% to 5.5%) at 220V when compared to the variable on-time control method.

Study on the Islanding Detection Technique of the Grid-Connected Photovoltaic System using Grid Voltage Harmonic Coefficients (계통전원 하모닉을 이용한 태양광 발전 시스템의 단독운전 검출기법에 관한 연구)

  • Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.417-424
    • /
    • 2010
  • This paper proposes a new islanding detection method for a grid-connected photovoltaic system. It is based on the fact that the equivalent harmonic components vary according to the grid connection status. The advantage of the proposed method is the reduced Non-Detection Zone and fast detection time. Also it can have the robust detection capability against grid disturbances. The theoretic analysis using grid-harmonic modeling is performed and verified by test result using 32-bit high performance DSP processor.

A Novel Digital Lock-In Amplifier Based Harmonics Compensation Method for the Grid Connected Inverter Systems (계통연계 인버터를 위한 디지털 록인 앰프 기반의 새로운 고조파 보상법)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.358-368
    • /
    • 2020
  • Grid-connected inverters (GCIs) based on renewable energy sources play an important role in enhancing the sustainability of a society. Harmonic standards, such as IEEE 519 and P1547, which require the total harmonic distortion (THD) of the output current to be less than 5%, should be satisfied when GCIs are connected to a grid. However, achieving a current THD of less than 5% is difficult for GCIs with an output filter under a distorted grid condition. In this study, a novel harmonic compensation method that uses a digital lock-in amplifier (DLA) is proposed to eliminate harmonics effectively at the output of GCIs. Accurate information regarding harmonics can be obtained due to the outstanding performance of DLA, and such information is used to eliminate harmonics with a simple proportional-integral controller in a feedforward manner. The validity of the proposed method is verified through experiments with a 5 kW single-phase GCI connected to a real grid.

A Hybrid Static Compensator for Dynamic Reactive Power Compensation and Harmonic Suppression

  • Yang, Jia-qiang;Yang, Lei;Su, Zi-peng
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.798-810
    • /
    • 2017
  • This paper presents a combined system of a small-capacity inverter and multigroup delta-connected thyristor switched capacitors (TSCs). The system is referred to as a hybrid static compensator (HSC) and has the functions of dynamic reactive power compensation and harmonic suppression. In the proposed topology, the load reactive power is mainly compensated by the TSCs. Meanwhile the inverter is meant to cooperate with TSCs to achieve continuous reactive power compensation, and to filter the harmonics generated by nonlinear loads and the TSCs. First, the structure and mathematical model of the HSC are discussed Then the control method of the HSC is presented. An improved reduced order generalized integrator (ROGI)-based selective current control method is adopted in the inverter to achieve high-performance reactive and harmonic current compensation. Meanwhile, a switch control strategy is proposed to implement precise and fast switching of the TSCs and to avoid changing the time delay needed by the conventional switch strategy. Experiments are implemented on a 20 KVA HSC prototype and the obtained results verify the validity of the proposed HSC system.

Harmonic Mean Weight by Combining Content Based Filtering and Collaborative Filtering in a Recommender System (내용 기반 여과와 협력적 여과의 병합을 통한 추천 시스템에서 조화 평균 가중치)

  • 정경용;류중경;강운구;이정현
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.3_4
    • /
    • pp.239-250
    • /
    • 2003
  • Recent recommender system user a method of combining collaborative filtering system and content based filtering system in order to slove the problem of the Sparsity and First-Rater in collaborative filtering system. In this paper, to make up for the prediction accuracy in hybrid Recommender system, the harmonic mean weight(CBCF_harmonic_mean) is used for calculating the user similarity weight. After setting up the threshold as 45 considering the performance of content based filtering, we apply significance weight of n/45 to user similarity weight. To estimate the performance of the proposed method, it if compared with that of combing both the existing collaborative filtering system and the content- based filtering system. As a result, it confirms that the suggested method is efficient at improving the prediction accuracy as solving problems of the exiting collaborative filtering system.

A Study on the PWM Generation using Time Average Model (시평균화방법을 이용한 PWM 신호발생에 관한 연구)

  • Hong, Soon-Wook;Cha, Jae-Deok;Cho, Kyu-Bock
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1088-1091
    • /
    • 1992
  • Programmed PWM(Pulse Width Modulated) generation techniques eliminating several low order harmonics have been widely used in the inverter circuit which produces minimum current ripple, reduced torque pulsation and thereby improves overall system performance. However, the applications of the programmed PWM technique are limited to CVCF(Constant Voltage Constant Frequency) applications and various motor drives. Although the programmed PWM produces a lower harmonic distorted waveform than the carrier modulated PWM, real-time programming is not possible because of the complicated calculation required for the gating signal. In this paper, a new programmed PWM technique named TAM (time averaging model) is developed to compensate for the demerits of the conventional programmed PWM technique with moderate harmonic distortion. Computer simulations are performed to verify the performance of the proposed algorithm.

  • PDF