• Title/Summary/Keyword: harmonic measure

Search Result 134, Processing Time 0.028 seconds

A Study on the Real Features of Harmonic Obstacle (고조파 장해의 진상에 관한 연구)

  • 이해기
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.162-171
    • /
    • 1998
  • This paper presents the harmonics obstacle analysis and countermeasure of electrical consumption a place. Harmonics that can be cosidered as a environmental pollution of the power systems become the cause of the accidents and damages. The responsibility of eliminating the harmonics firstly lies on the generating side. But the original characteristics of the system sush as the harmonic transfer characteristics and the impedance of the system affect each other in the process of the generation and transmission of the harmonic. Therefore it is very difficult to specify clearly the harmonic controlling responsibility, because electric machinery generating harmonics are various in the industrial fields. The output of a inverter has a high harmonic content. There are several ways of minimizing the output harmonic content. One way is to use pulse width modulation techniques within inverter. An alternative method is to combine a number of square-wave inverters. In this research, we measure the harmonic of the countermeasure of electrical consumption a place. The paper present the problem of new harmonic elimination method of PWM inverter fed induction motor system using W-FT series. In the future, the proposed PWM pattern by W-FT series is effective not only to the induction motor but also to the electromagnetic machine such as voltage reglator, UPS.

  • PDF

Harmonic Optimization Techniques in Multi-Level Voltage-Source Inverter with Unequal DC Sources

  • Aghdam, M. Ghasem Hosseini;Fathi, S. Hamid;Gharehpetian, Gevorg B.
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.171-180
    • /
    • 2008
  • One of the major problems in electric power quality is the harmonic contents. There are several methods of indicating the quantity of harmonic contents. The most widely used measure is the total harmonic distortion (THD). Various switching techniques have been used in static converters to reduce the output harmonic content. This paper presents and compares the two harmonic optimization techniques, known as optimal minimization of the total harmonic distortion (OMTHD) technique and optimized harmonic stepped-waveform (OHSW) technique used in multi-level inverters with unequal dc sources. Both techniques are very effective and efficient for improving the quality of the inverter output voltage. First, we describe briefly the cascaded H-bridge multi-level inverter structure. Then, we present the switching algorithm for the inverter based on OHSW and OMTHD techniques. Finally, the results obtained for the two techniques are analyzed and compared. The results verify the effectiveness of the both techniques in multi-level voltage-source inverter with non-equal dc sources, clarifying the advantages of each technique.

A Study on the Hormonic Analysis of on Electronic Ballast (전자식 안정기의 고조파 저감 대책)

  • Hong, Soon-Seuk;Oh, Jung-Suk;Yoo, Tae-Kun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.35-41
    • /
    • 2005
  • Electric ballast is widely used to turn on the fluorescent. Electric ballast measure occurrence of harmonic through the actual measurement and it is simulated by modeling equivalent circuit for harmonic analysis. The purpose of this paper is to give an equivalent circuit modeling methodology for the harmonic currents generated by single-phase loads to evaluate a commercially available series resonant filter for the harmonic currents compensation based on the IEC 61000-3-2 and IEEE Std 519-1992 standards for limiting harmonic distortion.

A Study on Measurement and Analysis of Harmonics in Substation (변전소 고조파 측정 및 분석에 관한 연구)

  • Han Mu-Ho;Park Tae-Joon;Lee Seung-Hee;Lee Chi-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator (풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향)

  • Rho, Sang-Pil;Park, Jung-Seok;Lee, Young-Gil;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

Effect Investigation of Resonance by Harmonic Components on Structures with Velocity Seismoprobes in a Turbine Rotor System (속도계가 부착된 구조물에서 조화성분의 공진이 미치는 영향 고찰)

  • Yang, Kyeong-Hyeon;Cho, Chul-Whan;Bae, Chun-Hee;Song, Oh-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.98-102
    • /
    • 2005
  • Most bearing casings are designed to focus on strength and weight of themselves because rotor speed passes through the critical speed when operation begins in large plants such as power plants. And It is treated importantly the relation between rotating frequency of the rotor and the natural frequency of casings to prevent resonance. But there is some cases that it is overlooked for harmonic components above rotating frequency. So we present experimentally a case that harmonic forces may make a resonance on casing fixing probes to measure vibration in a turbine-generator system and the vibration is generated when one component of harmonic forces excites the mode that the natural frequency of a certain bearing casing is close to one of harmonics of basic rotating frequency (1x).

  • PDF

Measurements of Sub- and Super Harmonic Waves at the Interfaces of Fatigue-Cracked CT Specimen

  • Jeong, Hyun-Jo;Barnard, Dan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Nonlinear harmonic waves generated at cracked interfaces are investigated both experimentally and theoretically. A compact tension specimen is fabricated and the amplitude of transmitted wave is analyzed as a function of position along the fatigued crack surface. In order to measure as many nonlinear harmonic components as possible a broadband Lithium Niobate ($LiNbO_3$) transducers are employed together with a calibration technique for making absolute amplitude measurements with fluid-coupled receiving transducers. Cracked interfaces are shown to generate high acoustic nonlinearities which are manifested as harmonies in the power spectrum of the received signal. The first subharmonic (f/2) and the second harmonic (2f) waves are found to be dominant nonlinear components for an incident toneburst signal of frequency f. To explain the observed nonlinear behavior a partially closed crack is modeled by planar half interfaces that can account for crack parameters such as crack opening displacement and crack surface conditions. The simulation results show reasonable agreements with the experimental results.

Harmonics Analysis of AC High Speed Railroad(HSR) System using Probabilistic Approach (확률론적 방법을 이용한 교류 고속철도 시스템의 고조파 해석)

  • Song Hak-Seon;Lee Jun-Kyong;Kim Jin-O;Kim Hyong-Chul
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.782-787
    • /
    • 2005
  • Magnitude of generated harmonic currents along with the operation of AC traction has nonlinear characteristics, and generated harmonic currents for high speed traction are more and more in high speed railroad(HSR) systems, especially. This paper presents probabilistic approximation method for the harmonic currents analysis about the operating speed of AC traction. To use probabilistic method for HSR system, probability density function(PDF) for collected operating speed based measure data is calculated. Mean and variance of harmonic currents of single traction are obtained based on the operating speed PDF and electrical traction model. The results of Monte Carlo Simulation(MCS) are in well accordance with the experimental and analytic methods. The harmonics of different number of trainloads are systematically investigated. It is assessed by the total demand distortion(TDD) for the HSR system.

  • PDF

Efficient Variable Dimension Quantization of Harmonic Magnitude (효율적인 가변차원 하모닉 크기 양자화기법)

  • 신경진;이인성
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.7
    • /
    • pp.47-54
    • /
    • 2001
  • In this paper, we present a variable dimension vector quantization for spectral magnitudes. Espectially, spectral magnitudes of the Harmonic coder, need variable dimension quantizer because those are not fixed dimension. So, this paper present efficient quantization methods. These methods use variable Discrete Cosine Transform(DCT) for spectral magnitude parameters and NSTVQ which is combined odd/even, split and multi-stage structure, proposed quantization methods use Spectral Distortion(SD) for performance measure. Consequently, Multi-Stage Nonsquare Transform Vector Quantization(MSNSTVQ) is the best in performance measure.

  • PDF

HARMONIC DOUBLING CONDITION AND JOHN DISKS

  • Kim, Ki-Won
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.1
    • /
    • pp.145-153
    • /
    • 1995
  • A Jordan domain D in C is said to be a c-quasidisk if there exists a constant $c \geq 1$ such that each two points $z_1$ and $z_2$ in D can be joined by an arc $\tau$ in D such that $$ \ell(\tau) \leq c$\mid$z_1 - z_2$\mid$ $$ and $$ (1.1) min(\ell(\tau_1),\ell(\tau_2)) \leq c d(z, \partial D) $$ for all $z \in \tau$, where $\tau_1$ and $\tau_2$ are the components of $\tau\{z}$. Quasidisks have been extensively studied and can be characterized in many different ways [1],[2],[3].

  • PDF