• 제목/요약/키워드: handpiece

검색결과 99건 처리시간 0.027초

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

치면열구전색제의 표면처리와 중합시간 증가에 따른 미반응 모노머 용리 평가 (MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING BY SURFACE TREATMENT AND CURING TIME)

  • 서현우
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.122-129
    • /
    • 2007
  • 본 연구는 복합 레진의 중합률에 영향을 미치는 광조사 시간을 달리하여 치면열구전색제를 중합하였을 경우 이로부터 용리되는 미반응 모노머들을 확인하고 정량화하고자 하였다. 그리고 치면열구전색제 중합 후 표면에 나타나는 미반응 모노머 층을 다양한 방법으로 제거한 후 용리되는 미반응 모노머들을 정량분석함으로써 미반응 모노머의 제거효과를 비교평가하고자 하였다. 광중합 시간에 따라 각각 20초, 40초, 60초간 중합한 후, 중합시간 별로 어떠한 처리도 시행하지 않은 군을 대조군, 증류수로 10초간 세척한 군을 I군(Group I), 75% 알콜에 젖은 면구로 10초간 문지른 군을 II군(Group II), 퍼미스와 러버컵을 이용하여 10초간 처리하고 증류수로 가볍게 세척한 군을 III군(Group III)으로 분류하였다. 표면처리 후 각 시편을 3차 증류수에 넣고 $37^{\circ}C$ 항온 수조에서 10분간 보관한 후 각각의 용리액을 고성능 액체 크로마토그래피를 이용하여 정성 및 정량 분석을 시행하였고 다음과 같은 결과를 얻었다. 1. 모든 대조군과 실험군에서 TEGDMA를 제외한 어떠한 모노머들도 검출되지 않았다. 2. 최소 중합시간, 권장 중합시간, 권장 중합시간 이상의 순으로 중합시간이 증가할수록 TEGDMA의 용리량은 감소하였다. 3. 표면처리를 한 군들은 대조군에 비하여 TEGDMA의 용리량이 유의할 만하게 감소하였다. 4. 표면처리를 한 군 가운데 퍼미스와 러버컵을 이용한 경우 잔존 모노머의 제거 효과가 다른 군에 비하여 유의성 있게 높았다. 5. 권장 중합시간 이상인 60초 중합 후, 퍼미스와 러버컵을 이용하여 표면처리한 경우 가장 적은 양의 모노머 용리량을 보였다.

  • PDF

도말층 제거와 상아질의 부위가 치수강 내부 상아질에 대한 수종 상아질 결합제의 전단결합성질에 미치는 영향 (THE EFFECT OF SMEAR LAYER REMOVAL AND POSITION OF DENTIN ON SHEAR BOND PROPERTIES OF DENTIN BONDING SYSTEMS TO INTERNAL CERVICAL DENTIN)

  • 임연아;유영대;이용근;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.465-472
    • /
    • 1999
  • The aim of this study was to determine the shear bond properties of four dentin bonding systems to internal cervical dentin, and to investigate the effect of the pretreatment for removing smear layer and position of dentin on shear bond strength of dentin bonding agents. The materials tested in this study were consisted of four commercially available dentin bonding systems[Allbond 2(AB), Clearfil Linerbond 2(CL), Optibond FL(OP), Scotchbond Multi-purpose(SB)], a restorative light-cured composite resin[Z100]J and a chelating agent[RC-prep(RC)]. Fifty-six freshly extracted human molars were used in this study. Dentin specimens were prepared by first cutting the root of the tooth 1mm below the cementoenamel junction with a diamond bur in a high speed handpiece under air-water coolant, and then removing occlusal part at pulp horn level by means of a second parallel section, The root canal areas were exposed by means of cutting the dent in specimens perpendicular to the root axis. Dentin specimens were randomly assigned to two groups(pretreated group, not-pretreated group) based on the pretreatment method of dentin surface. In pretreated group, RC was applied to dentin surface for 1minute and then rinsed with NaOCl. In not-pretreated group, dentin surface was rinsed with saline Each groups were subdevided into four groups according to dentin bonding systems. Four dentin bonding systems and a restorative resin were applied according to the directions of manufacturer. The dentin-resin specimens were embedded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of $1{\times}1mm$. The cut specimens were divided into three groups according to the position of internal cervical dentin. The shear bond properties of dentin-resin specimens were measured with Universal testing machine (Zwick, 020, Germany) with the cross head speed of 0.5mm/min. From this experiment. the following results were obtained : 1. In case of shear bond strength, there was no significant difference among dentin bonding systems in not-pretreated groups, whereas in pretreated groups, the shear bond strengths of AB and of SB were statistically significantly higher than those of CL and of OP. 2. The shear bond strengths of AB and of SB in pretreated groups were significantly higher than those in not-pretreated groups. 3. The shear bond strengths of radicular layer of OP were higher than those of occlusal layer of OP in not-pretreated groups, and of AB in pretreated groups. The shear bond strengths of radicular layer of AB and of CL in not-pretreated groups were higher than those in pretreated group.

  • PDF

아말감 수복시(修復時) Cavity varnish와 Bonding agent 도포(塗布)에 따른 접합성(接合性)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究) (A SCANNING ELECTRON MICROSCOPIC STUDY ON THE MARGINAL ADAPTIBILITY IN APPLYING THE CAVITY VARNISH AND DENTIN BONDING AGENT IN AMALGAM RESTORATIONS)

  • 김석훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.107-119
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal adaptability of the amalgam restorations in applying the cavity varnish (Copalite$^{(R)}$) and dentin bonding agent (Scotchbond 2$^{(R)}$) under the scanning electron microscope. For this study, eighteen sound extracted human molars were selected. Class I cavities in 12 teeth and class V cavities in 6 teeth were prepared using an air turbine with No. 701 tungsten carbide bur and finished using a low speed handpiece with No. 557 fissure bur. The prepared specimens were then divided into three groups including 4 class I cavities and 2 class V cavities in each group and restored as follows ; Group I. All the prepared cavities were restored with amalgam only (Control). Group II. Two layers of Copalite$^{(R)}$ cavity varnish were applied to the cavities with a gentle stream of air after each application and cavities were restored with amalgam. Group III. The enamel cavity margins were etched with 37% phosphoric acid gel for 60 sec., rinsed for 30 sec. and dried. One layer of visible lightcured Scotchbond Dental Adhesive$^{(R)}$ was applied and immediately cured for 20 seconds with visible light-cure unit and cavities were restored with amalgam. All the specimens were cut at the neck of the teeth and the occlusal halves of specimens were sectioned buccolingually in the longitudinal axis centering the amalgam restorations, using the disk. The cut specimens were ground with sandpapers (400, 600, 800, 1000 grit), and cleaned for 5 minutes in the ultrasonic cleaner (Brason Co. U.S.A.). In the cut surfaces, the amalgam - tooth interfaces were examined under the scanning electron microscope (JSM, 35C type, JEOL). The obtained results were as follows ; 1. The amalgam-tooth interfaces were reduced more significantly in the Copalite$^{(R)}$ and Scotchbond 2$^{(R)}$ application group than in the control group. 2. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed the findings similar to the Copalite$^{(R)}$ application group in the cavity floor, and the marginal adaptability was better in the side wall than in the cavity floor. 3. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed better marginal adaptability in the occlusal margin than in the gingival margin. 4. The marginal adaptability was in the order of the Scothbond 2$^{(R)}$ application group, the Copalite$^{(R)}$ application group and the control group.

  • PDF

구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발 (Development and application of stent-based image guided navigation system for oral and maxillofacial surgery)

  • 이우진;김대승;이원진;이삼선;최순철;허민석;허경회;김명진;이지호
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

치면열구전색제의 광중합 후 표면 처리 방법에 따른 미반응 모노머 용리 비교 (COMPARISON OF MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING VARIOUS SURFACE TREATMENT)

  • 이상우;이주현;서현우;박호원
    • 대한소아치과학회지
    • /
    • 제33권1호
    • /
    • pp.70-76
    • /
    • 2006
  • 본 연구에서는 치면열구전색제 중합 후 표면의 미반응 모노머 층을 임상에서 이용할 수 있는 다양한 방법으로 제거하고, 고성능 액체 크로마토그래피를 이용하여 미반응 모노머를 정량분석 함으로써 미반응 모노머의 제거효과를 비교 평가하고자 하였다. 표면처리 방법에 따라 광중합 후 표면을 어떤 처리도 시행하지 않은 군을 대조군, 증류수로 10초간 세척한 군을 I군(Group I), 75% 알콜에 젖은 면구로 10초간 문지른 군을 II군(Group II), 퍼미스와 러버컵을 이용하여 10초간 처리하고 증류수로 가볍게 세척한 군을 III군(Group III)으로 분류하였다. 표면처리 후 각각의 시편을 3차 증류수에 넣은 후 $37^{\circ}C$ 항온수조에서 10분간 보관한 후 각각의 용리액을 HPLC를 이용하여 정성 및 정량 분석하여 다음과 같은 결과를 얻었다. 1. 표면처리를 하지 않은 군과 표면처 리를 시행한 모든 군에서 TEGDMA를 제외한 어떠한 모노머들도 검출되지 않았다. 2. 표면처리를 한 모든 군은 표면처리를 하지 않은 군에 비하여, 용리되는 모노머량이 유의할 만하게 감소하였다(P<0.05). 3. 퍼미스와 러버컵을 이용해 표면처리한 군에서 잔존 모노머 제거효과가 다른 군에 비해 유의성 있게 높았다(P<0.05).

  • PDF

치과드릴 구동용 신 소형 2축 및 3축형 증속기어 강도특성 비교 (Strength Analyses of New 2- and 3-Axis-Type Small Multiplying Gears in Dental Hand-Pieces)

  • 김철;김주영;이중호;곽세호
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1027-1032
    • /
    • 2012
  • 치과 드릴치료기기 내부에 장착되는 신개념 소형 증속기어 및 그 배열의 2가지 개념설계안을 도출하고, 증속비, 모듈, 이의 수, 기어지름, 기어의 형태를 기구학적 계산으로 했으며, 이 두 형태의 증속기어열에 대해서 이의 접촉과 굽힘 강도특성을 AGMA식과 유한요소해석으로 분석하고, DLC 재료를 이에 코팅했을 때의 접촉강도를 계산하였다. 또한 기어재료에 대한 피로강도시험 및 인장시험을 수행하여 강도해석에 활용하였다. 3축방식보다 좀더 단순한 2축방식의 2번 맞물린 기어에 약간 더 큰 응력이 발생했으며, 피로해석 결과를 S-N 선도와 비교할 때 요구되는 수명을 만족함을 알 수 있었다. 고경도의 DLC 코팅된 기어의 접촉응력이 동일한 기어에서 그렇지 않은 기어에 비해 약 30% 정도 감소하여서 이 표면의 코팅이 중요함을 알 수 있다. 이러한 연구결과를 기초로 초소형 2축방식의 기어열과 핸드피스를 시제작하여 작동성능을 평가하였다.

Photobiomodulation and Miescher's cheilitis granulomatosa: case report

  • Porrini, Massimo;Garagiola, Umberto;Rossi, Margherita;Bosotti, Moreno;Marino, Sonia;Gianni, Aldo Bruno;Runza, Letterio;Spadari, Francesco
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.35.1-35.6
    • /
    • 2020
  • Background: Miescher's cheilitis granulomatosa (MCG) is a rare chronic inflammatory disease and is known as the monosymptomatic clinical form of Melkersson-Rosenthal syndrome (MRS). It is characterised by swelling of one or both lips and more frequently affects the upper lip. Histopathological findings show the presence of numerous inflammatory infiltrates and granuloma formations. Pharmacological treatments and surgery have provided results that are positive yet insufficiently stable in the long term. The clinical case described is of a 68-year-old female patient with a diagnosis of MCG of the upper lip. Case presentation: The patient was diagnosed and treated at the Oral Medicine and Oral Pathology outpatient clinic of Maxillofacial and Odontostomatology Unit, Fondazione Cà Granda IRCCS Ospedale Maggiore Policlinico. The patient was recommended localised treatments of photobiomodulation (PBM) using a diode laser with a 635 nm and 980 nm dual-wavelength (λ) approach, a 600-micron fibre, and a handpiece with a 1-cm-diameter lens at 300 mW. Three treatments a week were administered for four weeks for a total of 12 treatment sessions (T1-T12). After that, the patient had a long follow-up period of about 2 years. The therapeutic results were clear from the initial stages of treatment. There was an immediate, gradual, and consistent reduction in labial swelling. A reduction in the size of the lip by about 35% at T10-T12 was observed, returning the size and volume of the upper lip within the normal clinical range. The painful symptoms subsided after the seventh treatment (T7). The histopathological check at 3 months and the follow-up in particular confirmed the disease was in remission with satisfactorily stable treatment results. Moreover, the patient did not use any other treatments on the area from the early laser treatments through to the end of the follow-up period. Conclusions: Our experience describes a clinical case of MCG treated with PBM and effectively resolved with a reduction of the lip swelling. The real success of the treatment emerged over time, showing that the tissue healing was stable. In absence of any collateral phenomena, this confirms the effective and documented therapeutic potential of PBM for chronic inflammatory infiltrates.

수종의 CLEAN-UP technique이 법랑질 표면거칠기에 미치는 영향 (Effects of various CLEAN-UP techniques on enamel surface roughness)

  • 조상완;권오원
    • 대한치과교정학회지
    • /
    • 제27권5호
    • /
    • pp.791-800
    • /
    • 1997
  • 교정치료를 목적으로 발거한 소구치 60개를 4군으로 나누고 치과용 저속 절삭기에서 $18,500{\pm}300rpm$으로 회전속도를 일정하게 하여 4가지 회전 마무리 기구(G1; No. 169L carbide fissure bur, G2; No.2 round bur, G3; No.4 round bur, G4; No.8 round bur)로 잔여 레진을 제거하고 러버컵과 pumice로 법랑질을 5초간 마무리하였을 때 법랑질 손상에 미치는 정도를 알아보기 위해 브라켓 부착전 러버컵과 pumice로 전처치한 후(P1), 각 군에 해당하는 방법으로 잔여 레진을 제거한 후(P2), 러버컵과 pumice로 마지막 마무리 후(P3)의 법랑질 표면거칠기를 표면거칠기 측정기에서 각각 측정하고 주사전자현미경하에서 관찰하여 다음과 같은 결과를 얻었다. 1. P2에서 법랑질의 표면거칠기는 G1군의 경우 $2.60{\pm}0.55{\mu}m$으로 가장 매끄럽게 나타났고 G2군의 경우 $3.24{\pm}0.80{\mu}m$, G3군의 경우 $3.44{\pm}0.94{\mu}m$으로 나타났고 G4군의 경우 $3.89{\pm}0.54{\mu}m$으로 가장 거칠게 나타났으며 G2군과 G3군은 통계학적으로 유의성이 없었다(p>0.05). 2. P3에서 법랑질의 표면거칠기는 G1군의 경우 $2.29{\pm}0.47{\mu}m$으로 가장 매끄럽게 나타났고 G2군의 경우 $2.44{\pm}0.56{\mu}m$, G3군의 경우 $2.44{\pm}0.58{\mu}m$으로 나타났고 G4군의 경우 $2.92{\pm}0.43{\mu}m$으로 가장 거칠게 나타났으며 G1군은 G2군, G3군과, G2군은 G3군과 통계학적으로 유의성이 없었다(p>0.05). 3. 모든 군에서 P2, P3는 P1보다. P2는 P3보다 표면거칠기가 거칠게 나타났다(p<0.01). 4. 아무 처치도 하지 않은 정상 법랑질에 러버컵과 pumice로 5초간 전처치한 경우 주사전자현미경관찰에서 미세한 긁힘을 발견할 수 있었고 네군 모두에서 러버컵과 pumice로 연마 후에도 제거할 수 없는 흠을 남기며 러버컵과 pumice로 마무리 후 육안관찰시 잔여 레진을 발견할 수 없었으나 주사전자현미경하에서는 레진 잔사 등을 관찰할 수 있었다.

  • PDF

금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구 (Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis)

  • 조재영;강선녀;정창모;윤미정;허중보;전영찬
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.29-35
    • /
    • 2012
  • 연구 목적: 임플란트-골 계면에서 발생하는 과도한 열은 골유착을 저해하여 임플란트의 실패를 유발한다. 이에 이번 연구에서는 임플란트 금 합금 보철물의 교합면 삭제시 임플란트-골 계면으로의 열전달 양상과 냉각 방식의 효율성을 알아 보고자 하였다. 연구 재료 및 방법: 온도 감지 장치 제작을 위하여 Internal cone 연결형태의 임플란트에 16개의 K형 열전대를 부착하여 아크릴릭 레진에 포매하였다. 치과용 금 합금과 주조용 abutment를 사용하여 교합면에 3개의 요철을 가지는 시편을 10개 제작하였고, 연결 나사를 이용하여 임플란트와 연결한 뒤 온도 감지 장치를 $37^{\circ}C$ 유지되는 수조에 위치시켰다. 저속 핸드피스와 green stone bur를 이용하여 30초 동안 보철물의 요철을 삭제하였는데, 무냉각군, 공기 냉각 군, 물 분사 냉각 군으로 나누어 요철을 삭제하였다. 보철물이 삭제 되는 동안 임플란트의 부위별로 온도가 0.05초 간격으로 기록되었고, 삭제를 멈춘 뒤에도 무 냉각 군의 경우 임계 온도인 $47^{\circ}C$ 이하로 온도가 하강할 때까지, 공기 냉각군과 물 분사 냉각군의 경우 삭제 중단 후 30초 동안 추가로 온도를 기록하였다. 냉각 방식에 따른 임플란트-골 계면의 온도를 알아보고, 임플란트의 부위별 온도변화의 유의차를 알아보기 위하여 one-way ANOVA를 실시하였고, Turkey HSD 이용하여 95% 유의수준에서 사후 검증하였다. 결과: 무 냉각 군은 임플란트-골 계면의 온도가 $47^{\circ}C$ 이상으로 상승하였으며, 임플란트의 경부에서 유의하게 높은 열이 측정되었다(P>.05). 공기냉각군과물분사냉각군은 임플란트-골 계면의 온도가 $47^{\circ}C$ 이하로 유지되었다. 무 냉각 군에서 임플란트 경부의 온도가 $47^{\circ}C$에 도달되는 데는 약 $10.8{\pm}1.5$초가 소요되었다. 공기 냉각 군과 물 분사 냉각 군 사이에서는 임플란트-골 계면 온도의 유의차가 없었다(P>.05). 결론: 이상의 결과로부터 임플란트 금 합금 보철물의 교합면 삭제 시, 임플란트 주위 조직에 위해를 가할 수 있는 임계 온도 이상의 열이 발생했음을 알 수 있었으며, 냉각 방식은 공기 냉각과 물 분사 냉각 모두 효과적이라고 생각된다.