• Title/Summary/Keyword: half-dose

Search Result 536, Processing Time 0.034 seconds

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

Improvement of Mutation Rate and Reduction of Somatic Effects by Double Treatment of Chemical Mutagens in Barley (화학 돌연변이제 이중처리에 의한 돌연변이율 향상 및 생장저해 경감)

  • 구본철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.3
    • /
    • pp.348-353
    • /
    • 1996
  • Mutation tachniques inducing more useful mutations and reducing somatic effects need to be improved for crop breeding. Seeds of barley varieties ; Dema, Grosso were treated with two types of mutagens ; 1) chemical treatment: single treatment or double treatment of two mutagens (N-nitroso-N-methylurea ; MNH, Sodium Azide; NaN$_3$) 2) gamma ray irradiation treatment. After treatment, half of seeds were used for germination test and half of seeds were sown to the field. With the higher dose of mutagen both chemical and gamma ray were plants treated, the higher rate of growth reduction rate was in M$_1$ seedling. In chemical treatment, germination rate of seeds, growth rate of coleoptile and root in double treatment of chemical mutagens were better than single treatments, especially in same dose. Growth inhibition rate of plant in double treatment of 1.0mM MNH(0.5mM MNH + 0.5mM MNH), for example, were less than one of plants of single treatment of 1.0mM MNH in pot and petri dish test. Growth reduction rate of culm and fertility rate in M$_1$ plants double treated in same dose of single treatment were also less than single one. With the higher dose of mutagen both chemical and gamma ray were plants treated, the higher frequency of chlorophyll mutants was in M$_2$ seedling. The rate of chlorophyll mutants in double treatment of chemical mutagens were higher than single treatment. Double treatment methods can be a improved method for induction of new good mutants, which were induced more useful mutations and reduced harmful somatic effects.

  • PDF

A Study on the Image Quality of Mammography and the Average Glandular Dose (맘모그래피의 화질과 평균유선조직선량에 관한 검토)

  • Lee, In-Ja;Kim, Hak-Sung;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.47-55
    • /
    • 2002
  • We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospitals in Seoul. 1. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. 2. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospitals. The unit at the B hospital exceeded the allowable limit by ${\pm}0.15$. 3. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. 4. The image quality of breast phantom photography was affected by the screen/film system among the hospitals. 5. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured $0.26{\sim}1.39\;mGy$ less than ACR standard 3.0 mGy.

  • PDF

Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source (Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자에너지 플루언스와 질량에너지흡수계수 유도)

  • Kim, Jong-Eon;Ahn, Il-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • The purpose of this study is to derive photon energy fluence and mass energy absorption coefficient for 1 Gy of absorbed dose of water in brachytherapy using an Ir192 source. From the radiotherapy physics written by Khan, the half-value of lead for the gamma ray beam of the Ir192 source was obtained. The linear attenuation coefficient and the mass attenuation coefficient were calculated from the obtained half-value layer of lead. By matching the calculated lead mass attenuation coefficient with the NIST mass attenuation coefficient data, the photon energy of the matching mass attenuation coefficient was determined as the effective energy. By matching the determined effective energy with the photon energy of the NIST data on the mass energy absorption coefficient of water, the mass energy absorption coefficient of water was obtained as 0.03273 cm2/g(32.73 cm2/kg). The photon energy fluence was calculated as 0.03055 J/cm2 by dividing the obtained mass energy absorption coefficient (32.73 cm2/kg) by the absorbed dose of water 1 Gy.

Pharmacokinetics of $[^{14}C]$DA-5018 after Subcutaneous Injection and Topical Application (피하주사 및 국소도포시 $[^{14}C]$DA-5018의 약동력학)

  • 이응두;이종진;심현주;이상득;기원배;양중익;이명걸
    • Biomolecules & Therapeutics
    • /
    • v.5 no.1
    • /
    • pp.82-86
    • /
    • 1997
  • Pharmacokinetics of a new capsaicin analog, DA-5018 were evaluated after a subcutaneous injection or topical application of $[^{14}C]$--labelled or unlabelled DA-5018 to rats and rabbits. After subcutaneous injection of $_{14}$c-labelled or unlabelled DA-5018, 0.5 mg/kg (equivalent to DA-5018) to rats, the plasma total activity peaked at 2 hr with the terminal half life of 5.34 hr, however, unlabelled-DA-5018 peaked at 1 hr with the terminal half life of 1.26 hr. Moreover, the AUC (0.726 versus 0.2337g hr/ml) and MRT (7.82 versus 3.55 hr) increased significantly based on total radioactivity compared with intact DA-5018. Above data indicated that DA-5018 is extensively metabolized in rats and the terminal half- life of the metabolite(5) had a longer half-life than that of DA-5018. The cumulative percentages of biliary excretion of dose after subcutaneous injection of $[^{14}C]$DA-5018 was 40.2%, however, the value was only 2.14% when unlabelled DA-5018 was injected. After topical application of 0.1% or 0.3% $_{14}$C-labelled or unlabelled DA-5018 cream, 500 mg/kg to rats, the plasma and tissue concentrations except applied skin were under the detection limit. After consecutive 7 days topical application of unlabelled DA-5018, 0.1% and 0.3% cream to rats, the plasma concentrations were also under the detection limit. But the urinary excretion of DA-5018 was significantly increased by repeated topical administration. After topical application of unlabelled DA-5018, 0.1% and 0.3% cream to rabbits, the plasma and urine concentrations were under the detection limit. Above data indicated that the skin permeation of DA-5018 was lower and the metabolism of DA-5018 was higher in rabbits than that in rats.

  • PDF

Changes of Microbiological and General Quality Characteristics of Gamma Irradiated Half-Cooked Noodle (감마선 조사 숙면의 미생물 및 일반 품질특성 변화)

  • 김동호;육홍선;안현주;조철훈;변명우
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.3
    • /
    • pp.256-261
    • /
    • 2000
  • Effect of gamma irradiation on quality properties of half·cooked noodle was studied. The noodle were treated with lactic acid(0.1%, w/w), heat(10 min in boiling water) or their combination after cooking for 3 min, and irradiated at 0, 5 and 10 kGy. The noodle were stored at 25。C for 5 weeks and microbial population, Aw, pH, and texture profiles were examined. Fungi were completely eliminated by gamma-irradiation with 5 or 10 kGy does. Number of aerobic bacteria were also decreased by 2 and 4 log cycles with dose of 5 and 10 kGy, respectively. The D10 values of aerobic bacteria were 2.34∼2.95 kGy. Growth of the aerobic bacteria that survived even at 10 kGy of irradiation were significantly inhibited during storage. Acidification of half-cooked noodle was suppressed by gamma irradiation but A${_w}$ were not affected. Stickiness was decreased at the beginning of storage by gamma irradiation but was restored after 3 weeks. The results indicated that the gamma irradiation would be useful to improve quality and storage stability of half-cooked noodle.

  • PDF

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

Pharmacokinetic profile and tissue distribution of sulfamethazine in pigs and rats (돼지와 랫트에서 sulfamethazine의 약물동태학 및 조직분포)

  • Yun, Hyo-in;Park, Seung-chun;Oh, Tae-kwang;Cho, Joon-hyoung;Park, Jong-myeong
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.2
    • /
    • pp.291-299
    • /
    • 1997
  • In order to establish optimal dosage schedules and withdrawal times for sulfamethazine(SMZ) in pigs, pharmacokinetic and tissue distribution experiments were conducted in pigs. For comparative purposes, tissue depletion kinetics are also studied in rats. From three pigs administered with SMZ i.v., the pharmacokinetic profile of SMZ in two pigs was adequately described by a one-compartment open model whereas that in one pig was patterned after a two-compartment open model. Volume of distribution(Vd) was 0.48~0.57 L/kg and biological half-life($t_{1/2}$) was 11.8-16.8 h. From three pigs dosed with SMZ p.o., pharmacokinetic profile was explainable with a one-compartment open model. Time to reach maximum SMZ concentration in serum (Tmax) was 2.8 h, 3.2 h and 7.5 h. Elimination half-life was 2.8-7.5 h. The descending order in concentration of SMZ was plsama > kidney > liver > lung > heart > pancreas > spleen > duodenum > ileum > brain > adipsoe tissue from three pigs sacrificed at 5h, 29h and 54h after the administration of SMZ, p.o.. The protein binding of SMZ in pigs was 55.2%($2.5{\mu}g/ml$), 71.5% ($5{\mu}g/kg$) and 71.5%($10{\mu}g/ml$). The mean systemic bioavailability (F) of SMZ p.o. was 49.1 %. Meanwhile the pharmacokinetic profile of SMZ in rats was adequately described by a one-compartment open model. Absorption of SMZ p.o. in the rat was very rapid. In conclusion, the oral optimal dosage regimen of SMZ for pigs was the initial dose of 45.7 mg/kg followed by the maintenance dose of 30.2 mg/kg for high specific pathogens to SMZ. The time to reach below the stipulated residual allowable concentration (0.1 ppm) was calculated 93 h after oral administration of 200 mg/kg recommended by manufactureres.

  • PDF

Pharmacokinetics of LB20304, a New Fluoroquinolone, in Rats and Dogs

  • Seo, Mi-Kyeong;Lee, Sun-Hwa;Choi, Yun-Jeong;Jeong, Yi-Na;Lee, Sung-Hack;Kim, In-Chull;Lee, Yong-Hee
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.359-367
    • /
    • 1996
  • The pharmacokinetics of LB20304 was investigated following intravenous (IV) and oral administration to rats and dogs. Additionally, in vitro metabolism and serum protein binding studies were also conducted. The total body clearance, apparent volume of distribution, terminal half-life, and extent of bioavailability were 21.8 ml/min/kg, 2265 ml/kg, 93.6 min, and 30.8% for rats; and 7.95 ml/min/kg, 4144 ml/kg, 363 min, and 81.1% for dogs, respectively. LB20304 was stable in the liver microsome containing NADPH generating system and its serum protein binding was 58.5-65.8% for rats, 19.1-29.6% for dogs, and 56.9-59.6% for humans. Its tissue concentration levels in lever, stomach, small intestine, and kidney were 9.5 to 26.1 times greater than plasma level, but the concentration in testis was quite low and that in brain was negligible in rats. The 48 hr urinary recovery of the dose was 44% for IV dosing and 14% for oral dosing, shereas the 48 hr biliary recovery of the dose was 6.4% for IV dosing and 4.5% for oral dosing in rats. In summary, the pharmacokinetic properties of LB20304 were characterized by its good oral absorption, long plasma half-life, and good tissue distribution.

  • PDF