• Title/Summary/Keyword: guided

Search Result 3,987, Processing Time 0.024 seconds

Fine Needle Aspiration Cytology vs. Core Needle Biopsy for Thyroid Nodules: A Prospective, Experimental Study Using Surgical Specimen (갑상선 결절에 대한 세침 흡인 세포 검사와 중심부 바늘 생검의 비교: 수술 검체를 기반으로 한 전향적, 실험적 비교 연구)

  • Hyuk Kwon;Jandee Lee;Soon Won Hong;Hyeong Ju Kwon;Jin Young Kwak;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.645-657
    • /
    • 2022
  • Purpose To evaluate and compare the diagnostic outcomes of ultrasonography (US)-guided fine needle aspiration (FNA) and core needle biopsy (CNB) performed on the same thyroid nodule using a surgical specimen for direct comparison. Materials and Methods We included 89 thyroid nodules from 88 patients from February 2015 to January 2016. The inclusion criterion was thyroid nodules measuring ≥ 20 mm (mean size: 40.0 ± 15.3 mm). Immediately after surgical resection, FNA and subsequent CNB were performed on the surgical specimen under US guidance. FNA and CNB cytopathologic results on the specimen were compared with the surgical diagnosis. Results Among the 89 nodules, 30 were malignant and 59 were benign. Significantly higher inconclusive rates were seen in FNA for malignant than benign nodules (80.0% vs. 39.0%, p < 0.001). For CNB, conclusive and inconclusive rates did not differ between benign and malignant nodules (p = 0.796). Higher inconclusive rates were seen for FNA among cancers regardless of US features, and in the subgroup of size ≥ 40 mm (62.5% vs. 22.9%, p = 0.028). Eleven cancers were diagnosed with CNB (36.7%, 11/30), while none was diagnosed using FNA. Conclusion In this experimental study using surgical specimens, CNB showed a potential to provide improved diagnostic sensitivity for thyroid cancer, especially when a conclusive diagnosis is limited with FNA.

Postpartum Galactocele in Augmented Breast after Using Breast Pump Mimicking Breast Implant-Associated Anaplastic Large Cell Lymphoma: A Case Report (유방확대술 받은 수유 중인 여성에서 유축기를 사용한 뒤 발생한 유방 보형물 관련 역형성 거대 세포 림프종 모방 산후 젖낭종: 증례 보고)

  • Ga Young Lee;Gi Won Shin;Young Mi Park;Anbok Lee;Ha Young Park;Yoo Jin Lee;Ji-Yeon Han
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1570-1574
    • /
    • 2021
  • Post-partum galactocele is a common benign disease among breastfeeding women, whereas retromammary and peri-implant galactocele are relatively rare conditions. Herein, a 34-year-old, 1 month-postpartum female, who had augmentation mammoplasty and a 1-month history of breast pump use, presented with left breast enlargement for 2 weeks. An initial left breast US revealed hyperechoic peri-implant fluid collection. Additional US-guided fine needle aspiration was done using a 21G-needle, draining the milk component in the process, and cytologic results revealed numerous crystals, suggestive of galactocele. Various diseases, especially breast implant-associated anaplastic large cell lymphoma, can cause peri-implant fluid collection in an augmented breast. Thus, correlating imaging features with clinical information and cytologic analysis plays an important role in appropriate management.

Technical and Clinical Considerations for Successful Management of Postoperative Bowel Perforation by Percutaneous Foley Catheter Placement (경피적 폴리 카테터 삽입을 이용하여 수술 후 장 누출을 성공적으로 관리하기 위한 기술적 및 임상적 요인들)

  • So young Cho;Jung Suk Oh;Hae Giu Lee;Byung Gil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1389-1396
    • /
    • 2020
  • Purpose The aim of this study was to analyze several technical and clinical factors associated with the successful management of postoperative leakage by percutaneous Foley catheter placement. Materials and Methods Thirty-two patients were included in this retrospective study. Postoperative gastrointestinal leakage was diagnosed by computed tomography (CT) and the patients underwent percutaneous Foley catheter placement into the leakage site through Jackson-Pratt tubes or imaging-guided methods. Clinical success was defined as successful Foley catheter removal without symptom recurrence within 1 week and the risk factors for clinical failure were analyzed. Results In all patients, percutaneous Foley catheter placement was successfully achieved without complications. Foley catheter was placed at a median of 10 days (range, 1-68) after the confirmation of leakage on CT. Clinical success was achieved in 26 of the 32 patients (81%). Systemic comorbidity (p < 0.001) and failed oral intake (p = 0.015) were the statistically significant risk factors for clinical failure. Conclusion Percutaneous Foley catheter placement can be considered an effective approach for the management of postoperative bowel leakage. The presence of systemic comorbidity and successful oral diet after Foley catheter placement are significant factors for successful clinical recovery.

The Value of Adding Ductography to Ultrasonography for the Evaluation of Pathologic Nipple Discharge in Women with Negative Mammography

  • Younjung Choi;Sun Mi Kim;Mijung Jang;Bo La Yun;Eunyoung Kang;Eun-Kyu Kim;So Yeon Park;Bohyoung Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.866-877
    • /
    • 2022
  • Objective: The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. Materials and Methods: From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23-75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of follow-up with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar's test or a generalized estimating equation. Results: In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). Conclusion: The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

Validation of CT-Based Risk Stratification System for Lymph Node Metastasis in Patients With Thyroid Cancer

  • Yun Hwa Roh;Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1028-1037
    • /
    • 2023
  • Objective: To evaluate the computed tomography (CT) features for diagnosing metastatic cervical lymph nodes (LNs) in patients with differentiated thyroid cancer (DTC) and validate the CT-based risk stratification system suggested by the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) guidelines. Materials and Methods: A total of 463 LNs from 399 patients with DTC who underwent preoperative CT staging and ultrasound-guided fine-needle aspiration were included. The following CT features for each LN were evaluated: absence of hilum, cystic changes, calcification, strong enhancement, and heterogeneous enhancement. Multivariable logistic regression analysis was performed to identify independent CT features associated with metastatic LNs, and their diagnostic performances were evaluated. LNs were classified into probably benign, indeterminate, and suspicious categories according to the K-TIRADS and the modified LN classification proposed in our study. The diagnostic performance of both classification systems was compared using the exact McNemar and Kosinski tests. Results: The absence of hilum (odds ratio [OR], 4.859; 95% confidence interval [CI], 1.593-14.823; P = 0.005), strong enhancement (OR, 28.755; 95% CI, 12.719-65.007; P < 0.001), and cystic changes (OR, 46.157; 95% CI, 5.07-420.234; P = 0.001) were independently associated with metastatic LNs. All LNs showing calcification were diagnosed as metastases. Heterogeneous enhancement did not show a significant independent association with metastatic LNs. Strong enhancement, calcification, and cystic changes showed moderate to high specificity (70.1%-100%) and positive predictive value (PPV) (91.8%-100%). The absence of the hilum showed high sensitivity (97.8%) but low specificity (34.0%). The modified LN classification, which excluded heterogeneous enhancement from the K-TIRADS, demonstrated higher specificity (70.1% vs. 62.9%, P = 0.016) and PPV (92.5% vs. 90.9%, P = 0.011) than the K-TIRADS. Conclusion: Excluding heterogeneous enhancement as a suspicious feature resulted in a higher specificity and PPV for diagnosing metastatic LNs than the K-TIRADS. Our research results may provide a basis for revising the LN classification in future guidelines.

Treatment Outcomes of Percutaneous Radiofrequency Ablation for Hepatocellular Carcinomas: Effects of the Electrode Type and Placement Method

  • Jiyeon Park;Min Woo Lee;Soo Hyun Ahn;Seungchul Han;Ji Hye Min;Dong Ik Cha;Kyoung Doo Song;Tae Wook Kang;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.761-771
    • /
    • 2023
  • Objective: To investigate the association among the electrode placement method, electrode type, and local tumor progression (LTP) following percutaneous radiofrequency ablation (RFA) for small hepatocellular carcinomas (HCCs) and to assess the risk factors for LTP. Materials and Methods: In this retrospective study, we enrolled 211 patients, including 150 males and 61 females, who had undergone ultrasound-guided RFA for a single HCC < 3 cm. Patients were divided into four combination groups of the electrode type and placement method: 1) tumor-puncturing with an internally cooled tip (ICT), 2) tumor-puncturing with an internally cooled wet tip (ICWT), 3) no-touch with ICT, and 4) no-touch with ICWT. Univariable and multivariable Cox proportional-hazards regression analyses were performed to evaluate the risk factors for LTP. The major RFA-related complications were assessed. Results: Overall, 83, 34, 80, and 14 patients were included in the ICT, ICWT, no-touch with ICT, and no-touch with ICWT groups, respectively. The cumulative LTP rates differed significantly among the four groups. Compared to tumor puncturing with ICT, tumor puncturing with ICWT was associated with a lower LTP risk (adjusted hazard ratio [aHR] = 0.11, 95% confidence interval [CI] = 0-0.88, P = 0.034). However, the cumulative LTP rate did not differ significantly between tumor-puncturing with ICT and no-touch RFA with ICT (aHR = 0.34, 95% CI = 0.03-1.62, P = 0.188) or ICWT (aHR = 0.28, 95% CI = 0-2.28, P = 0.294). An insufficient ablative margin was a risk factor for LTP (aHR = 6.13, 95% CI = 1.41-22.49, P = 0.019). The major complication rates were 1.2%, 0%, 2.5%, and 21.4% in the ICT, ICWT, no-touch with ICT, and no-touch with ICWT groups, respectively. Conclusion: ICWT was associated with a lower LTP rate compared to ICT when performing tumor-puncturing RFA. An insufficient ablation margin was a risk factor for LTP.

Sonographic Diagnosis of Cervical Lymph Node Metastasis in Patients with Thyroid Cancer and Comparison of European and Korean Guidelines for Stratifying the Risk of Malignant Lymph Node

  • Sae Rom Chung;Jung Hwan Baek;Yun Hwa Rho;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1102-1111
    • /
    • 2022
  • Objective: To evaluate the ultrasonography (US) features for diagnosing metastasis in cervical lymph nodes (LNs) in patients with thyroid cancer and compare the US classification of risk of LN metastasis between European and Korean guidelines. Materials and Methods: From January 2014 to December 2018, US-guided fine-needle aspiration was performed on 836 LNs from 714 patients for the preoperative nodal staging of thyroid cancer. The US features of LNs were retrospectively reviewed for the following features: size, presence of hilum, margin, orientation, cystic change, punctate echogenic foci (PEF), large echogenic foci, eccentric cortical thickening, abnormal vascularity, and cortical hyperechogenicity. A multiple logistic regression analysis was performed to identify the independent US features for the diagnosis of metastatic LNs. The diagnostic performance of independent US features was subsequently evaluated. LNs were categorized according to the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and European Thyroid Association (ETA) guidelines, and the correlation between the two sets of classifications was assessed. Results: Absence of the hilum, presence of cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity were independent US features of metastatic LNs. Cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity showed high specificity (86.8%-99.6%). The absence of the hilum had the highest sensitivity yet low specificity (66.4%). When LNs were classified according to the ETA guidelines and K-TIRADS, they yielded similar categorizations of malignancy risks and were strongly correlated (Spearman coefficient, 0.9766 [95% confidence interval, 0.973-0.979]). According to the ETA guidelines, 9.8% (82/836) of LNs were classified as "not specified." Conclusion: Absence of hilum, cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity were independent US features suggestive of metastatic LNs in thyroid cancer. Both K-TIRADS and the ETA guidelines provided similar risk stratification for metastatic LNs with a high correlation; however, the ETA guidelines failed to classify 9.8% of LNs into a specific risk stratum. These results may provide a basis for revising LN classification in future guidelines.

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

  • Kyung Hee Lee;Kun Young Lim;Young Joo Suh;Jin Hur;Dae Hee Han;Mi-Jin Kang;Ji Yung Choo;Cherry Kim;Jung Im Kim;Soon Ho Yoon;Woojoo Lee;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1300-1310
    • /
    • 2019
  • Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

Primary Invasive Ductal Carcinoma Arising in Axillary Accessory Breast: A Case Report (겨드랑이 부유방 조직에서 발생한 원발성 유방암: 증례 보고)

  • Seo Young Park;Jeeyeon Lee;Ji Young Park;Gab Chul Kim;Jongmin Park;Jung Geun Cha;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.421-427
    • /
    • 2024
  • Ectopic breast tissue can develop along the mammary ridge from the axilla to the groin, and the most common site is the axillae. Primary carcinoma of ectopic breast tissue is extremely rare. We report a rare case of a 61-year-old woman with a palpable mass in her left axilla who had a history of surgical excision of accessory breast tissue in the same area. Mammography (MMG), including axillary tail view, ultrasound (US), and breast MRI were performed. We evaluated the extent and characteristics of the microcalcifications in the axillary tail view. A US-guided biopsy was done, and histopathology revealed an invasive ductal carcinoma. Enhanced abdominal CT revealed multiple hepatic masses consistent with metastases, and the patient received palliative chemotherapy. Herein, we present a rare case of breast cancer arising from accessory breast tissue in the axilla, best appreciated on the axillary tail view of the patient's MMG.