• Title/Summary/Keyword: guide

Search Result 7,489, Processing Time 0.039 seconds

Influence of Guide Vane Setting in Pump Mode on Performance Characteristics of a Pump-Turbine

  • Li, Deyou;Wang, Hongjie;Nielsen, Torbjorn K.;Gong, Ruzhi;Wei, Xianzhu;Qin, Daqing
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.154-163
    • /
    • 2017
  • Performance characteristics in pump mode of pump-turbines are vital for the safe and effective operation of pumped storage power plants. However, the head characteristics are different under different guide vane openings. In this paper, 3-D steady simulations were performed under 13mm, 19mm and 25mm guide vane openings. Three groups of operating points under the three GVOs were chosen based on experimental validation to investigate the influence of guide vane setting on flow patterns upstream and downstream. The results reveal that, the guide vane setting will obviously change the flow pattern downstream, which in turn influences the flow upstream. It shows a strong effect on hydraulic loss (power dissipation) in the guide and stay vanes. It is also found that the hydraulic loss mainly comes from the flow separation and vortices. In addition, in some operating conditions, the change of guide vane opening will change the flow angle at the runner inlet and outlet, which will change the Euler momentum (power input). The joint action of Euler momentum and hydraulic loss results in the change of the head characteristics.

Micro-Machined Capacitive Linear Encoder with a Mechanical Guide (마이크로 머시닝으로 제작한 기계적 가이드를 갖는 정전용량 선형 인코더)

  • Kang, Daesil;Moon, Wonkyu
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.440-445
    • /
    • 2012
  • Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) is a novel displacement sensor which has wide measurable range with high resolution. The sensor, however, is very sensitive to relative rotational alignment between stator and mover of the sensor as well as its displacement. In addition to, there can be some disturbances in the relative rotational alignment, so some noises occur in the sensor's output signal by the disturbances. This negative effect of the high sensitivity may become larger as increasing sensitivity. Therefore, this negative effect of the high sensitivity has to be compensated and reduced to achieve nanometer resolution of the sensor. In this study, a new type capacitive linear encoder with a mechanical guide is presented to reduce the relative rotational alignment problem. The presented method is not only to reduce the alignment problem, but also to assemble the sensor to the stage conveniently. The method is based on a new type CLECDiS that has mechanical guide autonomously. In the presented sensor, when the device is fabricated by micro-machining, the guide-rail is also fabricated on the surface of the sensor. By the direct fabrication of the guide-rail with high precision micro-machining, errors of the guide-rail can be reduced significantly. In addition, a manual yaw alignment is not required to obtain large magnitude of the output signal after the assembly of the sensor and the stage. The sensor movement is going to follow the guide-rail automatically. The prototype sensor was fabricated using the presented method, and we verify the feasibility experimentally.

A Study on Improvement of Inhalation Efficiency of Hood in Ventilation System for Elimination of Industrial Dust (산업용 분진 제거를 위한 배기장치 내 후드의 흡입성능 개선에 관한 연구)

  • Yang, Ho-Dong;Oh, Yool-Kwon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • The present study investigates on improvement of inhalation efficiency of hood in ventilation system for elimination of industrial dust. The hood, one of local exhaust ventilation system, has an important function to inhale a pollution source such as harmful dust and industrial waste. In this study, in order to improve the inhalation efficiency of the industrial hood, a new device named "gas-guide-device" was attached to inside of hood. The thermal fluid commercial code "Phoenics ver 3.1" was used to analyze the flow velocity distribution at the hood inlet and around the hood after gas-guide-device was installed. And the flow velocity on each position inside and around the hood was actually measured using the hot wire type anemometer under the same condition as that of numerical analysis. Also, in order to identify the optimum shape of gas-guide-device, numerical analysis and experiments are performed under various conditions and their results are presented. The results of this study revealed that the hood attached with gas-guide-device was higher the inhalation efficiency than that for without one and can be possible to improve the capture velocity of the industrial dust. And the optimum shape of gas-guide-device was identified that the ratio of two sizes of gas-guide-device, X to Y, has 4 to 6 on the basis of the hood size in use and the width (b) of gas-guide-device.

The Need for Web Style Guide and a case study of this the Development in the Domestic University Web sites (국내 대학 웹사이트에서 스타일 가이드의 필요성과 개발 사례 분석)

  • 제형건;최인규
    • Archives of design research
    • /
    • v.15 no.2
    • /
    • pp.137-146
    • /
    • 2002
  • From the early period of web design, there has discussed the need for style guide. But, it has not known specifically 'what it is' and 'how it should be applied'in the actual situation. Most web sites seem to be considered as 'would-be-same or similar'in those impressions. In case of domestic companies or corporations, the development of web style guide has been established, in addition to the trials to adopt Cl(corperate identity) into the web sites. In the universities, with the advent of the era of unlimited competitions among the universities, the need and the importance of web sites has been increasingly emphasized because most internet users, teenagers and twenties, have great interests in the universities and they actually constitute the university societies. But, in reality, the effort to adopt Ul(university identity) into the web sites has left so much to be desired. As one methodology, reflecting the characteristics of the university web sites and the financial reasons, it is assorted that the development of 'web style guide'is urgent. This report explains web style guide and its importance, in addition to the suggestion for the development of web style guide for the domestic university.

  • PDF

Invention of the Guide Catheter Irrigation Monitoring Device for Neuroendovascular Therapy

  • Ozkul, Ayca;Park, Jong-Hyun;Shin, Dong-Seung;Yilmaz, Ali;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.471-474
    • /
    • 2017
  • Objective : The thromboembolic events during neuroendovascular therapy (NET) are the major complications of concern that can be occasionally fatal. The thrombotic occlusion of the guide catheter for NET is thought to be the risk of the thromboembolic events. We have developed an idea for inventing the monitoring system of the continuous irrigation through the guide catheter. We herein present a unique invention of the guide catheter irrigation monitoring device. Methods : We have developed ideas for preventing the thrombotic occlusion of the guide catheter. In order to design a convenient device working in the practical use, we have consulted and shared the ideas with the electrical engineers about putting the invention. Results : The guide catheter irrigation monitoring device (GCIMD) consisted of three parts of optical sensor, main body and electric adapter. In brief, the basic principles of working of the GCIMD are as follows. The optical sensor is attached to the dripping chamber of the line to irrigation solution. The main body had the small light and speaker to make an alarm sounds. The sensor monitors the dripping of flush solution. If the dripping stops more than three seconds, a warning alarm has been activated. So, the operating physicians can concentrate and check the guide catheter irrigation. After the use of the GCIMD, there was no major thromboembolic complication in conjunction with the thrombotic occlusion of the guide catheter in our institute. Conclusion : We have developed a brilliant invention of the GCIMD for NET.

Development of Teflon Coating Equipment Used in Medical Treatment (의료용 가이드 와이어의 테프론 코팅 장치 개발)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.344-349
    • /
    • 2018
  • This paper proposes a method of designing the main parameters of the Teflon coating equipment of a guide wire used in medical treatment. The proposed device was designed to be guided by a reel-to-reel method in which the guide wire performs all processes continuously, such as Teflon coating and heat treatment. At this time, the conveyed guide wire vibrates between the rollers, which affects the quality of the coating. Therefore, this paper proposes a dynamic equation of the guide wire to be transported in the longitudinal direction, and design parameters setting method of the feed speed and the interval of the roller supporting the wire is proposed to minimize the vibration amplitude of the guide wire during transport. The Teflon coating of the medical guide wire was carried out based on the developed coating equipment. The target coating thickness of the guide wire was set to less than $10{\mu}m$ in the circumferential direction, and the results were examined by optical microscopy.

Development of a General Occupational Safety and Health (OSH) Guide for Maintenance in Etching, Deposition, and Ion Implantation Facilities (반도체 공정 설비 정비 작업 안전보건 가이드: 증착, 식각, 이온주입)

  • Kyung Ehi Zoh;Taek-hyeon Han;Jae-jin Moon;Ingyun Jung;Yeong Woo Hwang;Seyoung Kwon;Kyung-yoon Ko;Mingun Lee;Jaepil Chang;Dong-Uk Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.125-133
    • /
    • 2024
  • Objectives: The aim of this study is to develop a comprehensive Occupational Safety and Health (OSH) guide for maintenance tasks in semiconductor processing, specifically focusing on etching, deposition, and ion implantation processes. Methods: The development of the OSH guide involved a literature review, consultations with industry experts, and field investigations. It concentrates on Maintenance Work (MW) operations in these specialized areas. Results: The result is a detailed OSH guide tailored to MW in etching, deposition, and ion implantation facilities within semiconductor processing. This guide is structured to assist maintenance workers through pre-, during and post-MW phases, ensuring easy comprehension and adherence to safety protocols. It highlights the necessity of safety and health measures throughout the MW process to protect personnel. The guide is enriched with real-life scenarios and visual aids, including cartoons and photographs, to aid in the understanding and implementation of safety and health principles. Conclusions: This OSH guide is designed to enhance the protection of workers engaged in maintenance activities in the electronics sector, particularly in semiconductor manufacturing. It aims to improve compliance with safety and health standards in these high-risk environments.

Light guide based optical engine for light-valve-projection

  • Salters, B.A.;Krijn, M.P.C.M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.935-938
    • /
    • 2004
  • We have studied several light guide concepts for light-valve projection engines. The aim of the light guide is to replace the array of lenses and mirrors in conventional transmission-type projection engines. Volume, cost and weight can be reduced, at a similar or better performance level. Results of a first prototype are discussed.

  • PDF