• Title/Summary/Keyword: group detection

Search Result 1,677, Processing Time 0.029 seconds

A Correlation Analysis between Land Surface Temperature and NDVI in Kunsan City using Landsat 7 TM/ETM+ Satellite Images (Landsat 7 TM/ETM+ 위성영상을 이용한 군산지역 지표 온도와 NDVI에 대한 상관분석)

  • Lee, Hong-Ro;Kim, Hyung-Moo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.2
    • /
    • pp.31-43
    • /
    • 2005
  • Four time points of the fractional area data during the 15 years of the highest group of land surface temperature and the lowest group of NDVl of the Kunsan city Chollabuk_do, Korea located beneath the Yellow sea coast, are observed and analyzed their correlations for the intention to detect the changes of urban land cover. As long as the effective contributions of satellite images in the continuous monitoring of the wide area for wide range of time period, Landsat-5 TM and Landsat-7 ETM+ artificial satellite images, acquisited over the Kunsan city area, are surveyed by the compared calibration after quantization and classification of the deviations between TM and ETM+ images substituted approved error correction thresholds such as gains and biases or offsets. This experiment and research applied Landsat-5 TM and Landsat-7 ETM+ artificial satellite images in change detection of urban land cover in urbanized Kunsan city, then detected strong and proportional correlation relationship between the highest group of land surface temperature and the lowest group of NDVI which exceeded R=(+)0.9478, so the proposed Correlation Analysis Model between the highest group of land surface temperature and the lowest group of NDVI will be able to give proof an effective suitability to the land city change detection monitoring.

  • PDF

Development of a pretreatment method for determination of levels of perfluorinated compounds in foods according to fat and protein contents (지방과 단백질 함량에 따른 식품의 과불화화합물 분석을 위한 전처리 방법 확립)

  • Bang, Sunah;Park, Na-youn;Hwang, Youngrim;Kang, Gil Jin;Kim, Hye-Jeong;Kang, Young-Woon;Kho, Younglim;Kim, Jung Hoan
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.14-20
    • /
    • 2018
  • Perfluorinated compounds (PFCs) have recently been recognized as global environmental pollutants. This study was performed to develop an analytical method for determination of levels of PFCs in food by LC-MS/MS. One hundred and nine food products were divided into two groups based on their fat and protein contents (high and low), following which samples containing high fat and protein contents were pooled and subjected to pretreatment consisting of enzymatic degradation and hexane extraction. The limit of detection of 17 PFCs in the samples were in the range of 0.013-0.145 ng/g. The degrees of precision of detection for group 1 (samples with low fat and protein contents) and group 2 (samples with high fat and protein contents) were 0.8-21.1 and 1.7-28.2%, respectively, with an accuracy of 78.8-109.8% for group 1 and 80-114.5% for group 2. This study indicated that pretreatment of high fat and protein foods with enzymatic degradation and hexane extraction would improve the detection of PFCs in food.

Qualitative Assessment of Breast Cancer Early Detection Services Provided through Well Woman Clinics in the District of Gampaha in Sri Lanka

  • Vithana, Palatiyana Vithanage Sajeewanie Chiranthika;Hemachandra, Nilmini Nilangani;Ariyaratne, Yasantha;Jayawardana, Pushpa Lalani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7639-7644
    • /
    • 2013
  • Background: Breast cancer is the most common cancer diagnosed among women in Sri Lanka. Early detection can lead to reduction in morbidity and mortality. The objective here was to identify perceptions of public health midwives (PHMs) on the importance of early detection of breast cancer and deficiencies of and suggestions on improving existing breast cancer early detection services provided through Well Woman Clinics. Materials and Methods: A qualitative study using four focus group discussions (FGDs) were conducted among 38 PHMs in the Gampaha district in Sri Lanka and the meetings were audio-recorded, transcribed and analyzed using constant comparison and identifying themes and categories. Results: All the PHMs had a firm realization on the need of breast cancer early detection. The four FGDs among PHMs revealed non-availability of guidelines, inadequacy of training, lack of skills and material to provide health education, inability to provide privacy during clinical examination, shortage of stationery, lack of community awareness and motivation. The suggestions for the improvements of the programme identified in FGDs were capacity building of PHMs, making availability of guidelines, rescheduling clinics, improving the supervision, strengthening the monitoring, improving coordination between clinical and preventive sectors, and improving community awareness. Conclusions: Results of the FGDs can provide useful information on components to be improved in breast cancer early detection services. Study recommendations were training programmes at basic and post basic levels on a regular basis and supervision for the sustainance of the breast cancer early detection program.

Tumor Inhibition Effects and Mechanisms of Angelica sinensis and Sophorae flavescentis ait Decoction Combined with Cisplatin in Xenograft Mice

  • Yan, De-Qi;Liu, Yong-Qi;Li, Ying-Dong;Li, Dou;Cheng, Xiao-Li;Wu, Zhi-Wei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4609-4615
    • /
    • 2014
  • Background: To investigate tumor inhibition effects and mechanisms of Angelica sinensis and Sophorae flavescentis ait decoction (ASSF) combined with diamine-dichloroplatinum (DDP). Materials and Methods: Bodyweight, tumor inhibition rate and q value were calculated for single ASSF or ASSF combined with DDP on H22 carcinoma xenograft KM mice. Biochemical methods for serum LDH, AST, ALT, and AKP, ELISA method for serum HIF-$1{\alpha}$, pathological assessemnt of thymus, immunohistochemistry detection of tumor tissue caspase3 and mutant p53 protein, and qRT-PCR detection of bax/ bcl-2 mRNA were applied. Results: Compared with DDP control group, the bodyweight increased in ASSF-DDP group (p<0.01). Tumor inhibition rates for DDP, ASSF, ASSF-DDP were 62.7%. 43.7% and 71.0% respectively, with a q value of 0.90. Compared with other groups, thymus of DDP control group had obvious pathological injury (p<0.01), serum LDH, AST, ALT, AKP increased significantly in DDP control group (p<0.01), while serum HIF-$1{\alpha}$ was increased in the model control group. Compared with this latter, the expression of mutant p53 protein and bcl-2 mRNA were decreased in all treatment groups (p<0.01), but there were no statistical difference between DDP control p and ASSF-DDP groups. The expression of caspase3 protein and bax mRNA was increased in all treatment groups, with statistical differences between the DDP and ASSF-DDP groups (p<0.01). Conclusions: ASSF can inhibit bodyweight decrease caused by DDP, can inhibit tumor growth synergistically with DDP mainly through increasing serum HIF-$1{\alpha}$ and pro-apoptotic molecules such as caspase 3 and bax, rather than through decreasing anti-apoptotic mutant p53 and bcl-2. ASSF can reduce DDP toxicity due to decreasing the release of LDH, AST, ALT, AKP into blood and enhancing thymus protection.

Development of an Axially Viewed Inductively Coupled Plasma for Atomic Emission Spectrometry and Comparison between the Detection Limits of Lead (원자방출 분광분석을 위한 수평형 유도결합 플라스마의 개발과 납 검출한계 비교)

  • Cho, Sung Il;Han, Myung Sub;Lee, Sang Hwa;Lee, Joung Hae;Woo, Jin Chun
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.6
    • /
    • pp.292-298
    • /
    • 1997
  • An ICP(Inductively Coupled Plasma) emission spectrometer was developed with an axially viewed ICP source incorporated by a 5-turned induction coil and a torch, outer quartz tube of which was 50 mm longer than that used in conventional ICP/AES(Inductively Coupled Plasma Atomic Emission Spectrometry). The Optimization of the system has been performed in terms of the determination of signal-to-noise ratio and background intensity at various rf powers, sample flow rates, argon gas flow rates and cut-off gas flow rates. The spectro-analytical characteristics of the spectrum obtained between 200 and 500 nm was revealed to be similar compared with a vertically viewed ICP source. The detection limit of Pb(Ⅱ) at 220.35 nm was 11 ppb which was 5 times lower than that obtained with a vertically viewed ICP source.

  • PDF

Ultrasonographic Mass Screening for Thyroid Carcinoma (초음파를 이용한 갑상선암의 집단검진)

  • Chung Woong-Yoon;Chang Hang-Seok;Kim Eun-Kyung;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.177-181
    • /
    • 1999
  • Objective: The clinical significance of mass screening for thyroid carcinoma remains unclear. This study was carried out to clarify the value of mass screening for thyroid carcinoma. Materials and Methods: From December 1997 through July 1998, a total of 1,401 subjects who were enrolled to receive breast screening or follow-up examination for breast cancer were included in this study. Thyroid glands were examined by 10 MHz ultrasonography by one experienced radiologist. The patients with thyroid nodules were classified into 2 groups according to their potential risk of malignancy by ultrasonographic findings(high-risk : hypoechogenicity, microcalcification, irregular margin, taller than wider shape). High-risk patients were advised to undergo fine-needle aspiration biopsy and thyroidectomy. The characteristics of the thyroid cancers detected by ultrasonographic mass screening were compared by those of clinical thyroid cancer excluding male patients during the same period. Results: Thyroid nodules were detected in 353(25.2%) of the subjects and 259(73.4%) were listed in the low-risk group and 94(26.6%) in high-risk group. Among 94 patients in the high-risk group, 43 underwent thyroidectomy and 37 turned out to have thyroid carcinomas. Thus, the detection rates for carcinoma were 2.6% of all subject, 10.5% of the detected nodules, 36.4% of the high risk women and 86.0% of the operated cases. The tumor size was significantly smaller in the mass-screening group than in the clinical cancer group(p<0.05). However, there was no statistical differences between two groups in the prevalences of neck node involvement and extracapsular invasion and the patients distributions by AMES score, MACIS score and TNM stage. Conclusion: Ultrasonogrpahic mass screening may be useful for the early detection of thyroid carcinoma in women who are scheduled to have breast examination.

  • PDF

Pulsed Terahertz Emission and Detection Properties from ZnTe Crystal (ZnTe 결정을 이용한 테라헤르츠파의 발생 및 검출 특성)

  • Jin, Yun-Sik;Jeon, Seuk-Gy;Kim, Keun-Ju;Sohn, Chae-Hwa;Jung, Sun-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.553-559
    • /
    • 2005
  • Pulsed terahertz (THz) radiation was generated by optical rectification and detected by a fee space electro-optic sampling (FS-EOS) method. We used ZnTe (110) crystals for both generation and detection. By coating dielectric anti-reflection film on the ZnTe crystal surface, we can reduce the reflectance of a pump laser beam from $30\%$ to $2\%$, and the terahertz pulse amplitude increased $27\%$ compared with an uncoated crystal. A wider bandwidth of THz radiation was obtained by using a thinner crystal but the signal intensity was decreased in this case. And variations of THz radiation by changing orientation of the ZnTe crystal with respect to the pump (or probe) laser polarization, and by changing the power of the pump laser have also been investigated and discussed.

Protective effects of IgY against diarrhea in suckling piglets -I. Serological result, FA test and RT-PCR- (IgY 투여에 따른 포유자돈의 설사에 대한 예방효과 -I. 혈청학적 결과, 형광항체검사 및 RT-PCT 검사-)

  • Jin, Wen;Yoon, Byung-Il;Han, Jeong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.1
    • /
    • pp.101-111
    • /
    • 2008
  • The purpose of this study was to investigate the protective effects against porcine epidemic diarrhea virus (PEDV) and transmissible gastroenteritis virus (TGEV) in suckling piglets by oral administration of IgY. Twenty piglets were divided into two groups with the same number: group I (treated with IgY) and group II (not treated). Group I was administerd orally with IgY for three days from one-day-old and experimentally challenged with PEDV and TGEV at four-day-old. The other was administered with saline solution and challenged with PEDV and TGEV at four-day-old. Serum antibody titers against PEDV and TGEV were examined by enzyme-linked immunosorbent assay (ELISA) and the detection of PEDV or TGEV antigen from feces and small intestines was performed by reverse transcription-polymerase chain reaction (RT-PCR) and indirect immunofluorescence (IFA). The antibody titers of the group I was higher than that of the other, and lasted at the end of experiment. In the detection tests of both virus from feces and small intestine, the rate of the group I was lower. Based on these results, oral administration of IgY may be effective to prevent the diarrhea caused by PEDV and TGEV.

Detection method of proximal caries using line profile in digital intra-oral radiography (디지털 구내방사선사진에서 라인 프로파일을 이용한 인접면우증식의 인지 방법)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Kim, Gyu-Tae;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.185-189
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. Materials and Methods : The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Results : Mean values of D were $0.0354{\pm}0.0155$ in non-caries and $0.2632{\pm}0.0982$ in caries (p<0.001). Conclusion : The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  • PDF

Numerical simulation of localization of a sub-assembly with failed fuel pins in the prototype fast breeder reactor

  • Abhitab Bachchan;Puspendu Hazra;Nimala Sundaram;Subhadip Kirtan;Nakul Chaudhary;A. Riyas;K. Devan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3648-3658
    • /
    • 2023
  • The early localization of a fuel subassembly with a failed (wet rupture) fuel pin is very important in reactors to limit the associated radiological and operational consequences. This requires a fast and reliable system for failure detection and their localization in the core. In the Prototype Fast Breeder Reactor, the system specially designed for this purpose is Failed Fuel Location Modules (FFLM) housed in the control plug region. It identifies a failed sub-assembly by detecting the presence of delayed neutrons in the sodium from a failed sub-assembly. During the commissioning phase of PFBR, it is mandatory to demonstrate the FFLM effectiveness. The paper highlights the engineering and physics design aspects of FFLM and the integrated simulation towards its function demonstration with a source assembly containing a perforated metallic fuel pin. This test pin mimics a MOX pin of 1 cm2 of geometrical defect area. At 10% power and 20% sodium flow rate, the counts rate in the BCCs of FFLM system range from 75 cps to 145 cps depending upon the position of DN source assembly. The model developed for the counts simulation is applicable to both metal and MOX pins with proper values of k-factor and escape coefficient.