• 제목/요약/키워드: groundwater resistivity

검색결과 150건 처리시간 0.023초

전기비저항 모니터링을 이용한 터널 주변 지반상태 변화 파악 (Analysis of Ground Deformation Deformation using Resistivity Monitoring Technique at a Tunnel Excavation Area)

  • 안희윤;정재형;조인기;박삼규;김기석;정래철
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.93-100
    • /
    • 2007
  • During tunnel excavation, drawdown of groundwater table or discharge from tunnel faces may not only reduce stability of tunnel and work efficiency but cause environmental problems. We have investigated the applicability of electrical resistivity survey for the establishment of the monitoring system for groundwater behavior and detecting flow channel of groundwater during tunnel excavation. The groundwater level was continuously measured at several points for 1 year. Survey was conduted at every 3 months using preinstalled electrical resistivity cables on site. The results show that observed changes in resistivity ratios in the area can be explained with observed changes in groundwater level. Thus, we believed that electrical resistivity analysed together with groundwater data can be applied for the monitoring of groundwater in tunnel area.

  • PDF

부산지역의 해저용출수 전기비저항탐사 (Resistivity Exploration of Submarine Groundwater Discharge in Busan Area)

  • 박준규;김성욱;이진혁;김인수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.711-716
    • /
    • 2010
  • This study selected the promising area of submarine groundwater discharge(SGD) that flows into the sea following unconfined physical aquifer through the electrical resistivity survey of the land and sea. The submarine groundwater discharge(SGD) mostly flows into the sea following fracture zones, and the detection of the fault zone becomes the important guideline of groundwater discharge. Electrical sounding of the land assessed the groundwater flow and integration possibility according to the location of a fault that is a water path between underground reservoir and surface water as well as a rock fracture. In addition, the study conducted sea electrical resistivity to expand the area with high potential and selected the expected water potential groundwater area. The areas of the study were Busan and coastal areas, and for the terrain analysis, the candidates of the ground exploration were selected after analyzing lineaments that is expanded to coast direction.

  • PDF

토양 및 지하수 오염지역에 대한 전기비저항탐사의 적용성 연구 (A Study on the Applicaton of Electrical Resistivity Survey in the Contaminated Soil and Groundwater Site)

  • 채승헌;이상은;정교철
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.525-539
    • /
    • 2020
  • 본 연구지역은 피혁 제조공정에서 발생된 고형폐기물, 처리용수 및 유류 저장용기 등이 매립되어 있는 지역이다. 피혁폐기물 매립으로 발생된 침출수에 의한 오염영역을 파악하기 위하여 토양·지하수 오염도 조사 및 전기비저항탐사를 수행하였다. 토양오염 분석 결과 TPH와 아연 항목에서 토양오염 우려기준을 초과하였으며, 침출수 및 지하수의 경우 6가 크롬 항목이 지하수 정화기준을 초과하는 것으로 파악되었다. 전기비저항탐사는 토양·지하수 오염특성 및 확산경로를 파악하기 위하여 쌍극자배열법으로 전극간격이 5 m인 총 10개의 측선을 설정하였다. 토양·지하수 오염도 조사의 결과와 저비저항이상대가 비교적 잘 일치하였다. 따라서 본 연구지역과 같이 폐기물 매립에 따른 불규칙한 지층분포와 토양·지하수가 복합적으로 오염된 지역에서 전기비저항탐사를 병행하면 오염원에 의한 수직?수평적인 확산경로, 오염영역 및 향후 오염 예상지역에 대한 모니터링을 계획하는데 있어서 유용한 조사기법으로 사용될 수 있을 것이다.

불포화 사질토 지반의 지반조건 및 침출수 오염도에 따른 전기비저항의 변화

  • 오명학;이주형;박준범;김형석
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.47-50
    • /
    • 2001
  • The laboratory tests were peformed to investigate the relationship between electrical resistivity and the unsaturated subsurface condition and to evaluate the contamination due to leachate based on measuring electrical resistivity. For weathered granite soil, the electrical resistivity of soil decreases as moisture density increases. The electrical resistivity of soil decreases as the concentration of leachate in pore fluid increases since leachate contains various ionic constituents. And the modified Archie's equation for applying to unsaturated sand is derived by regression analysis.

  • PDF

염수침입 현상의 전기비저항 분석에 대한 지구통계기법의 응용

  • 심병완;정상용;김병우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.92-96
    • /
    • 2001
  • Although the problem of seawater intrusion at the coastal aquifer was recognized before over one hundred years at the coastal aquifer, much groundwater keep on being salinitized by several reasons such as groundwater exhaustion, coastalline change, and human activities. The horizontal and vertical electrical soundings and geostatistical methods were used to define the local characteristics of saltwater intrusion and to estimate the saltwater interface in the southeastern area of the Pusan City. The 24 points of the Schlumberger vertical electrical soundings(VES) to loom depth and the 2 lines of dipole-dipole horizontal soundings are peformed. The resistivity data have lognormal distributions. The horizontal extents of saline water intrusion were estimated from the inversion of horizontal prospecting data. Lognormal ordinary kriging is used in A-A' resistivity profiles on May and July because the data have stationary models in semivariograms. Lognormal IRF-k kriging is used for the isopleth maps using vertical resistivity data. The 10 ohm-m resistivity line on the isopleth maps of 21m, 30m, 50m, and 70m depth using resisitivity data measured in July is sifted to the east, cpomparing that of the isopleth maps measured in May. The kriged vertical and horizontal resistivity isopleth maps suggested that the geostatistical methods can be used to define the variation of earth resistivity distribution at the saltwater interface.

  • PDF

전기비저항 모니터링 방법을 이용한 충적층 지하수위 변동 감지 (Detection of Groundwater Table Changes in Alluvium Using Electrical Resistivity Monitoring Method)

  • 김형수
    • 지질공학
    • /
    • 제7권2호
    • /
    • pp.139-149
    • /
    • 1997
  • 전기비저항 모니터링을 이용하여 충적층 지하수위의 변동을 감지 할 수 있는지의 여부가 연구되었다. 연구는 유한요소법을 이용한 전기비저항 수치 모델링 시험과 20일간의 장기 양수 시험이 수행된 금강 정동리 지역의 현장 자료를 이용하여 수행되었다. 수치 모델링 시험 및 현장 자료 획득은 전극 기본 간격이 4m인 21개의 고정전극을 이용하였으며, 전극배열은 "변형 웨너 배열"과 쌍극자 배열을 이용하였다. 현장 장기 양수 시험에서 관측된 수위 변화를 단순화하여 지하 2차원 비저항 모델로 사용한 사용한 결과, 겉보기 전기비저항의 변화 양상은 수위 변화보다 둔감한 변화 양상을 보여 주며, 수위 변화가 있는 부분뿐만 아니라하부 결정질 기반암의 경계 부위에 해당하는 심도에서도 겉보기 비저항 장치가 변화하는 현상이 관측되었다. 이러한 수치 결과와 부합되는 결과가 실제 현장에서 획득된 겉보기 전기 비저항 단면에서도 나타났다. 수치 계산결과 및 현장 자료는 전기 비저한 모니터링이 지하수위 변동을 유무 감지하는데 유용하게 사용될 수 있음을 보여주었다. 그러나 겉보기 전기비저항 단면이 수위 변동량을 정량적으로 규명할 만큼의 뚜렷한 변화를 보여주지는 못하기 때문에 전기비저항 방법만으로 정략적인 수위변동을 감지하는데 한계가 있는 것으로 판단되었다. 이러한 지하 수위 변동량 등을 명확히 규명하기 위해서는 고해상도 탄성파 또는 지하레이다 탐사처럼 지하의 모습을 영상화 할 수 있는 지구물리 탐사법이 병행되는 것이 바람직하다.

  • PDF

국내 서.남해 해안지역 지하수의 전기비저항과 등가 NaCl 염분도와의 관계 (Relationship Between the Groundwater Resistivity and NaCl Equivalent Salinity in Western and Southern Coastal Areas, Korea)

  • 황세호;박권규;신제현;이상규
    • 지구물리와물리탐사
    • /
    • 제10권4호
    • /
    • pp.361-368
    • /
    • 2007
  • 본 논문은 지표 및 시추공 전기 전자탐사 결과의 정량적인 해석을 위하여 해안 지하수의 전기비저항과 등가 NaCl 염분도와의 관계식을 제안하였다. 해안에서 10 km 이내에 위치하고 전기전도도가 1,000 ${\mu}S/cm$ 이상인 38개의 지하수 시료에 대한 수리지구화학 분석 결과를 이용하여 전기비저항과 등가 NaCl 염분도와의 관계식을 유도하였다. 수리지구 화학분석 결과의 등가 NaCl 염분도 환산은 Schlumberger 도표 GEN-8을 이용하였으며 전기전도도는 현장에서 휴대용 장비로 측정하였다. 본 논문에서 해안 지하수의 수리지구화학분석 결과를 이용하여 제안한 해안 지하수의 전기비저항$(R_w)$ 과 등가 NaCl 염분도(Eq_NaCl)와의 관계식은 Eq_NaCl=$5935.3551{\times}R_w^{-1.0993}$이며 전기전도도(EC)와 용존고형물총량(TDS)과의 관계식은 TDS=0.721${times}$EC와 같다. 해안대수층 지하수의 전기비저항과 등가 NaCl 염분도 및 TDS와의 관계식은 서 남해 해안지역의 해수침투 평가에 유용하게 이용될 것으로 판단된다.

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

충적층 조사를 위한 모래와 점토의 유도분극 특성 고찰 (A study on induced polarization characteristics of sand and clay for alluvium investigation)

  • 최상혁;김형수;김지수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.179-184
    • /
    • 2008
  • 충적층 구성 물질 중 포화된 실트 혹은 점토층은 상대적으로 낮은 전기비저항 값을 나타낸다. 낮은 전기비저항 값은 이 지층을 투수성이 높은 대수층으로 오인하는 문제를 발생시킨다. 이러한 문제를 극복하고 충적층 내 포화된 실트 혹은 점토층과 모래 혹은 자갈 대수층을 구분하기 위해 전기비저항 조사와 함께 유도분극 조사를 활용하는 방안을 검토하였다. 본 연구에서는 우선, 실내 실험을 통해 충적층 구성 물질별 전기비저항(resistivity)과 충전성(chargeability)을 조사하였고, 비분극 전극을 활용한 현장 수직 전기비저항/유도분극 조사를 수행하였다. 실내 실험을 통해 모래/점토 혼합층에서 점토함량이 증가함에 따라 비저항은 낮아지고, 충전성은 높아짐을 확인하였다. 이러한 실험 결과를 바탕으로 강변여과 현장에서 전기비저항/유도분극 조사를 수행하였다. 자료의 정량적 해석을 통해, 낮은 비저항과 낮은 충전성을 갖는 지층이 상대적으로 투수성이 우수하고 지하수 산출성이 높은 충적 대수층에 해당되는 것으로 최종 해석하였다.

  • PDF