• 제목/요약/키워드: groundwater quality

검색결과 617건 처리시간 0.024초

Prediction of Groundwater Level in Chojung Area (초정지역의 지하수 유동해석)

  • 안상도;김경호;정영훈
    • Journal of the Korean Society of Groundwater Environment
    • /
    • 제7권3호
    • /
    • pp.133-140
    • /
    • 2000
  • The area of Chojung is famous for its mineral water quality. Because of this reason, massive groundwater development was induced in the area. As a result of excessive pumping. the depletion of the groundwater resources is expected seriously. This study was conducted to analyse groundwater flow in Chojung using a numerical model. Simulation results show the groundwater level change slowly in the mountain area but steep groundwater drawdown occurred in the pumping area in the downstream. This steep groundwater drawdown is due to excessive pumping in the hilly region. Because of this excessive, desiccation of water resources were predicted and proper countermeasure is in great demand.

  • PDF

Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer (암반 대수층에서 개방형 지열 시스템의 개발 및 적용)

  • Shim, Byoung Ohan;Kim, Seong-Kyun;Choi, Hanna;Lee, Soo-Hyoung;Ha, Kyoochul;Kim, Yongchul
    • New & Renewable Energy
    • /
    • 제17권3호
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.

Management Plan for Rural Groundwater Resources in the Era of Post COVID-19 (포스트 코로나 시대 농어촌지하수 관리 방안)

  • Lee, Byung Sun;Seo, Sangjin;Lee, Gyusang;Yoon, Seok-Hwan;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • 제27권4호
    • /
    • pp.1-9
    • /
    • 2022
  • This study was conducted to supplement new-normal strategies on management plans of rural groundwater resources in the era of Post COVID-19. Global outbreak of COVID-19 has damaged across all areas including public policy, economics, industrial services, and others without exception, which has resulted in establishing new-normal strategies in order to restore balance and functions as for these areas. The new-normal ones were represented as enhancing preventative management on infectious diseases, expanding non face-to-face services, enhancing protective trades and food securities, and preparing growth policies on public services using the 4th industrial revolution techniques. In this study, G-WASH_AD (Groundwater supply, sanitation, and hygiene with attraction and digitization) was suggested to be new-normal strategies on rural groundwater resources. The G-WASH_AD was consisted of three detailed action plans: a preventative plan on waterborne-diseases of groundwater (PP), a groundwater-tourism plan with rural heritage (GP), and an application plan of the 4th industrial revolution techniques to groundwater facilities and its data (P4). The PP can contribute to protect human health from waterborne-diseases and minimize hazardous effects on crop cultivation. The GP accompanied with high-quality groundwater resources is able to strengthen rural tourism, to promote marketing activities on local agricultural products, and to increase household incomes of rural communities. The P4 can reinforce fast, comfortable, and scientific management on groundwater facilities and its data, creating a virtuous cycle between innovative management on groundwater and growth of technology related to it. Results of the G-WASH_AD strategies can encourage a green growth engine in field of rural groundwater management keeping up with Post COVID-19.

Assessing Groundwater Vulnerability Using DRASTIC Method and Groundwater Quality in Changwon City (DRASTIC과 지하수 수질에 의한 창원시 지하수 오염취약성 평가)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Moo-Jin;Kim In-Soo;Hwang Han-Seok
    • Economic and Environmental Geology
    • /
    • 제37권6호
    • /
    • pp.631-645
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in industrial and residential/commercial areas of the city of Changwon, using DRASTIC technique and groundwater data. The DRASTIC technique was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. Mostly the industrial area has higher DRASTIC indices than the residential/commercial area. However, a part of the residential/commercial area having much groundwater production and great drawdown is more contaminated in groundwater than other industrial and the residential/commercial areas even if it has lowest DRASTIC indices in the study area. It indicates that groundwater contamination in urban areas can be closely related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is as low as 0.40. On the other hand, the correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well distribution density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other human-made factors such as groundwater withdrawal rate and well distribution density per unit area as well as the existing seven DRASTIC factors.

Effect of Low Concentration Liquid Manure application on Soil Water and Groundwater Quality in Bio-Circulation Experimental Forest (바이오순환림의 저농도액비 시용에 따른 토양수 및 지하수 수질 영향 분석)

  • Hong, Eun-Mi;Choi, Jin-Yong;Yoo, Seung-Hwan;Nam, Won-Ho;Yeo, Jin-Kie;Choi, In-Gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제52권5호
    • /
    • pp.37-45
    • /
    • 2010
  • Manure recycling as fertilizer is one of solutions for the environmental problem related with livestock manure treatment as well as the ocean dumping ban act prohibiting manure disposal to the ocean. For the manure disposal, forest area can be a candidate place because the area has a wide range of applicable sites. However, the manure application to the forest has a possibility of causing environmental impacts including water quality problems due to nutrient loading. Therefore it is necessary to investigate water quality impact from manure disposal to the forestry plantation. In this study, ground and soil water quality had been monitored in the bio-circulation experimental forest where low concentration liquid manure (LCLM) was applied. Soil and groundwater samples were collected and analyzed weekly from April to October in 2008 and 2009. The mean and variation of NO3-N concentration in soil water of LCLM treatment places showed higher concentration than the reference places declining during growing season. In the case of groundwater from monitoring well in the downstream of disposal site, the $NO_3$-N concentration was 3.59 mg/L in 2008 and 3.26 mg/L in 2009 in average showing higher concentration than the reference well although the concentration was not exceed the national drinking water standard. To investigate the source of nitrate, $\delta^{15}N$ isotope analysis was also implemented. Its result showed that the LCLM application could be the nitrate source requiring further long-term monitoring soil and water quality.

Evaluation of Groundwater Quality Characteristics around Uncontrolled Closed Valley Landfill (사용종료 비위생매립지 주변 지하수의 수질변화 특성)

  • Park, Joung-Ku;Kim, Tae-Dong;Choi, Dong Hyuk;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • 제12권3호
    • /
    • pp.75-80
    • /
    • 2007
  • This study evaluated groundwater quality around an uncontrolled landfill in W sity, Korea, which was monitored for about two years (2005-2006). Parameters of concern include redox-sensitive indicators such as pH, DO, EC, ORP, DOC (dissolved organic carbon), NH3, NO3 and SO4. About 10 years have elapsed after closing dumping of municipal wastes in the landfill. Leachates showed widely varying concentrations in COD(136${\sim}$263 mg/L), T-N(121${\sim}$186 mg/L), and NH3-N(14${\sim}$369 mg/L). Groundwater at the immediate downgradient of the landfill showed weakly acidic pH condition but very high levels of EC (3,000-4,000 ${\mu}S/cm$), which indicated that the groundwater was largely affected by the landfill leachate. Cl, a conservative ion, showed over 200 mg/L at the landfill border, but a gradually decreasing level with distance from the landfill, representing dispersion and dilution (natural attenuation) due to mixing with surrounding groundwater and replenished rainwater. Redox potential showed negative value at the landfill border but it increased up to 350 mV at downgradient wells, which indicated conversion of redox condition from reducing oxic ones. Ammonia, was largely enriched at most of the monitoring wells and its level greatly exceeded drinking water standard. In summary, all the parameters evidenced occurrence of natural attenuation with distance and with time but further monitoring is still required.

Evaluation on Four Volatile Organic Compounds (VOCs) Contents in the Groundwater and Their Human Risk Level

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-Hyun;Lee, Gyeong-Mi;Kim, Ki-In;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • 제50권4호
    • /
    • pp.235-250
    • /
    • 2017
  • In this study, we monitored 4 volatile organic compounds (VOCs) such as chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane in groundwater samples to determine the detection frequency and their concentrations and evaluated the health risk level considering ingestion, inhalation, and skin contact. 75 groundwater wells were selected. 24 wells were from monitoring background groundwater quality level and 51 wells were from monitoring groundwater quality level in industrial or contamination source area. In the results, the detection frequency for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane was 42.3%, 8.1%, 6.0%, and 3.4%, respectively. The average concentrations of VOCs were high in the order of chloroform ($1.7{\mu}g\;L^{-1}$), dichloromethane ($0.08{\mu}g\;L^{-1}$), tetrachloromethane ($0.05{\mu}g\;L^{-1}$), and 1,2-dichloroethane ($0.05{\mu}g\;L^{-1}$). Chloroform had the highest detection frequency and average detection concentration. In the contaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, 1,2-dchloroethane, and tetrachloromethane. The average concentrations for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane were $2.23{\mu}g\;L^{-1}$, $0.08{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.06{\mu}g\;L^{-1}$, respectively. All the 4 compounds were detected at industrial complex and storage tank area. The maximum concentration of chloroform, dichloromethane, and 1,2-dichloroethane was detected at industrial complex area. Especially, the maximum concentration of chloroform and dichloromethane was detected at a chemical factory area. In the uncontaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, and 1,2-dchloroethane and tetrachloromethane was not detected. The average concentrations for chloroform, dichloromethane, and 1,2-dichloroethane were $0.57{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.03{\mu}g\;L^{-1}$, respectively. Although chloroform in the uncontaminated groundwater was detected the most, the concentration of chloroform was not exceeding water quality standards. By land use, the maximum detection frequency of 1,2-dichloroethane was found near a traffic area. For human risk assessment, the cancer risk for the 4 VOCs was $10^{-6}{\sim}10^{-9}$, while the non-cancer risk (HQ value) for the 4 VOCs is $10^{-2}{\sim}10^{-3}$.

Groundwater Contamination at the Seokdae Waste Landfill Area of Pusan City (부산 석대 폐기물 매립장 일대의 지하수 오염)

  • 정상용
    • Journal of the Korean Society of Groundwater Environment
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 1995
  • Wastes produce groundwater contamination, offensive odor, and hazardous gases. This study investigates the contamination of groundwater at the Seokdae waste landfill area and seeks the desirable ways to minimize the groundwater contamination. Groundwater levels, water chemistry and aquifer characteristics of wells were examined around the Seokdae waste landfill. The water chemistry of the Dong stream, the groundwater distribution and flow were also studied. The results of this research show that the estimated quantity of the percolation from the landfill base to the ground is 520 ㎥/day and the extent of groundwater contamination is about 1-1.5 km from the center of the waste landfill. The groundwater contains heavy metals and other toxic elements. The conservation and management of the groundwater of the waste landfill need several monitoring wells to check the quantity and quality of groundwater, pumping wells to extract the contaminated groundwater, and slurry walls to protect the movement of contaminated groundwater.

  • PDF

Analyzing the Effect of a Weir Construction on the Groundwater Flow System (보 건설이 주변지역 지하수 흐름계에 미치는 영향)

  • Jeong, Soo-Jeong;Koo, Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • 제17권3호
    • /
    • pp.39-48
    • /
    • 2012
  • Visual MODFLOW, a three dimensional groundwater flow model, was used to analyze effects of a weir construction in an alluvial stream on the nearby groundwater flow system. A hypothetical conceptual model was developed to investigate how the groundwater level and the water budget could change after a weir construction depending on the location of tributary streams. A site example, dealing with the Juksan weir installed in the Yeongsan River, was also demonstrated to predict the effects of the weir construction. Model results show that impacts of a weir construction on the groundwater flow system greatly vary depending on how far a tributary is located and whether it is located downstream or upstream from the weir. Therefore, consideration of the location of tributaries in planning the location of a weir could effectively minimize the impacts of a weir construction on the groundwater flow system. It is also demonstrated that model results are highly dependent upon how the model is dealing with small tributaries and agricultural drainage channels, which can be easily found nearby the main streams, acting as major water bodies for groundwater discharge. The model for the Juksan area shows that the weir construction will change the direction of groundwater flow in some areas, leading to changes of groundwater quality and interaction of the Yeongsan River to the aquifer from a gaining to a losing stream. The model also predicted the areas where rise of groundwater level caused by the Juksan weir could adversely affect plant growth, and thereby suggested installing new drainage channels as a countermeasure to drawdown the groundwater level.

Application and Assesment of Regrouting Method for Improperly Constructed Wells in Jeju Island (제주도의 오염 방지 시공이 부실한 지하수 관정에 대한 구간 차폐 공법의 적용과 평가)

  • Kim, Mijin;Kang, BongRae;Cho, Heuy Nam;Choi, Sung Ouk;Yang, Won-Seok;Park, Wonbae
    • Journal of Soil and Groundwater Environment
    • /
    • 제25권3호
    • /
    • pp.43-51
    • /
    • 2020
  • About 90% of groundwater wells in Jeju Island are reported to be under the threat of contamination by infiltration of the surface pollutants. Most of those wells have improperly grouted annulus which is an empty space between the well and the inner casing. As a remedy to this problem, some of the wells were re-grouted by filling the annulus with cement without lifting an inner casing. In order to evaluate whether this method is appropriate for the geological structure of Jeju Island, two wells (W1 and W2) were selected and this method was applied. The water holding capacity did not decrease while the nitrate levels decreased from 16.8 and 20.2 to 6.8 and 13.8 mg/L in W1 and W2, respectively. The higher nitrate level in W2 is deemed to be influenced by the livestock farms located in the upper area of the well. In addition, transmissivity of the vedose zone was higher in W2 than W1, potentially facilitating the transport of nitrate to the groundwater. The overall result of this study suggests re-grouting of wells for the purpose of protecting water quality of goundwater should take into account geological structure of vadose zone as well as appropriate source control of the contaminants.