• Title/Summary/Keyword: groundwater discharge equation

Search Result 16, Processing Time 0.023 seconds

A Study on the Development of Regional Master Recession Curve Model

  • Lee, Jae-Hyoung;Oh, Nam-Sun;Lee, Hee-Ju
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.61-71
    • /
    • 2001
  • A regional master recession curve model to predict groundwater discharges in a given basin was presented. Considering a stream-aquifer system, both theoretical and experimental baseflow equations were compared and a practical groundwater discharge equation was derived, The groundwater discharge equation was expanded and transformed to the discharge equation at the basin exit. For practical use, the equation was expressed as a function of watershed area, the mean slope of basin and the recession constant. To verify the model, the model was applied to Ssang-chi basin where long-term and temporal hydrological data at the upper basin were collected. Our results show that a master recession curve of unmeasured area can be predicted.

  • PDF

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

A Study on the Base Flow Recession Curve Development in the Ssangchi Basin of the Sumjin River (섬진강 쌍치유역의 기저유출 감수곡선식 개발에 관한 연구)

  • 김경수;조기태
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.66-72
    • /
    • 2000
  • The purpose of this study is establish a recession curve for low flow discharge in the Ssangchi basin. For this study, we selected 34 recession segments and calculated recession constants and initial discharges. The average initial discharge is 0.40 ㎥/sec and the recession constant is 0.86. With using the initial discharge and the recession constant, We got the non-linear recession cure equation. This non-linear equation is more reasonable fit than the linear equation of the recession curve for low flow.

  • PDF

Estimation of Baseflow Discharge through Several Streams in Jeju Island, Korea (제주도 주요하천의 기저유출량 산정)

  • Moon Duk-Chul;Yang Sung-Kee;Koh Gi-Won;Park Won-Bae
    • Journal of Environmental Science International
    • /
    • v.14 no.4
    • /
    • pp.405-412
    • /
    • 2005
  • Groundwater in Jeju Island, flowing through main stream, is spring water from underground. To set a fixed quantity of groundwater flowing from surface in a hydrological view, 4 downstream (Woedo stream, Gangjung stream, Yeonwoe stream and Ongpo stream) were selected to calculate the characteristic of baseflow and the base-flow discharge through the data on tachometry. There were 11 to 14 level peak caused by runoff, mostly occurred during monsoon season. Also, duration of runoff was 15 to 25 hours, well reflecting the characteristic of inclined, short stream length in Jeju Island and pervious hydrogeographical feature. In case of Gangjung stream, Yeonwoe stream and Ongpo stream, variation of stream water level by baseflow rose above during summer, which was closely linked to the distribution of seasonal precipitation. From autumn to spring, water level fell below while that of Woedo stream remained the same all year round. Data on the water level observed in Woedo stream and Gangjung stream in every single minutes was applied to weir formula(equation of Oki and Govinda Rao) to calculate baseflow discharge. Also, using the data on current and water level calculated in Ongpo stream and Yeonwoe stream, water level-water flow rating was applied to assess base flow discharge.

Application of Flux Average Discharge Equation to Assess the Submarine Fresh Groundwater Discharge in a Coastal Aquifer (연안 대수층의 해저 담지하수 유출량 산정을 위한 유량 평균 유출량 방정식의 적용)

  • Il Hwan Kim;Min-Gyu Kim;Il-Moon Chung;Gyo-Cheol Jeong;Sunwoo Chang
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.105-119
    • /
    • 2023
  • Water supply is decreasing due to climate change, and coastal and island regions are highly dependent on groundwater, reducing the amount of available water. For sustainable water supply in coastal and island regions, it is necessary to accurately diagnose the current condition and efficiently distribute and manage water. For a precise analysis of the groundwater flow in the coastal island region, submarine fresh groundwater discharge was calculated for the Seongsan basin in the eastern part of Jeju Island. Two methods were used to estimate the thickness of the fresh groundwater. One method employed vertical interpolation of measured electrical conductivity in a multi depth monitoring well; the other used theoretical Ghyben-Herzberg ratio. The value using the Ghyben-Herzberg ratio makes it impossible to accurately estimate the changing salt-saltwater interface, and the value analyzed by electrical conductivity can represent the current state of the freshwater-saltwater interface. Observed parameter was distributed on a virtual grid. The average of submarine fresh groundwater discharge fluxes for the virtual grid was determined as the watershed's representative flux. The submarine fresh groundwater discharge and flux distribution by year were also calculated at the basin scale. The method using electrical conductivity estimated the submarine fresh groundwater discharge from 2018 to 2020 to be 6.27 × 106 m3/year; the method using the Ghyben-Herzberg ratio estimated a discharge of 10.87 × 106 m3/year. The results presented in this study can be used as basis data for policies that determine sustainable water supply by using precise water budget analysis in coastal and island areas.

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF

Minimum Entropy Deconvolution을 이용한 지하수 상대 재충진양의 시계열 추정법

  • 김태희;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.574-578
    • /
    • 2003
  • There are so many methods to estimate the groundwater recharge. These methods can be categorized into four groups. First groupis related to the water balance analysis, second group is concerned with baseflow/springflow recession, and third group is interested in some types of tracers; environmental tracers and/or temperature profile. The limitation of these types of methods is that the estimated results of recharge are presented in the form of an average over some time period. Forth group has a little different approach. They use the time series data of hydraulic head and specific yield evaluated from field test, and the results of estimation are described in the sequential form. But their approach has a serious problem. The estimated results in forth typeof methods are generally underestimated because they cannot consider the discharge phase of water table fluctuation coupled with the recharge phase. Ketchum el. at. (2000) proposed calibrated method, considering recharge- and discharge-coupled water table fluctuation. But the dischargeis considered just as the areal average with discharge rate. On the other hand, there are many methods to estimate the source wavelet with observed data set in geophysics/signal processing and geophysical methods are rarely applied to the estimation of groundwater recharge. The purpose this study is the evaluation of the applicability of one of the geophysical method in the estimation of sequential recharge rate. The applied geophysical method is called minimum entropy deconvolution (MED). For this purpose, numerical modeling with linearized Boussinesq equation was applied. Using the synthesized hydraulic head through the numerical modeling, the relative sequenceof recharge is calculated inversely. Estimated results are very concordant with the applied recharge sequence. Cross-correlations between applied recharge sequence and the estimated results are above 0.985 in all study cases. Through the numerical test, the availability of MED in the estimation of the recharge sequence to groundwater was investigated

  • PDF

Assessment of Potential Groundwater Resources for Optimal Management of Coastal Groundwater (해안 지하수 최적관리를 위한 개발가능량 산정 기법)

  • Park, Nam-Sik;Hong, Sung-Hun;Seo, Kyung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.8
    • /
    • pp.665-675
    • /
    • 2007
  • An equation is developed to estimate potential groundwater resources available for development. This equation is useful for preliminary planning stages prior to detailed design stages. The equation is a function of major factors such as aquifer characteristics, saltwater intrusion length, coastal groundwater discharge and potential locations of pumping wells. Thus, most important factors are taken into account. The equations are derived using well-known analytical solutions. Thus, the basis is scientifically sound. Use of the equation is quite simple since it is an explicit function of variables. A logical method is proposed to assess a radius of influence of a pumping well considering aquifer characteristics and the pumping rate. Applications to a hypothetical problem and comparison with results from a more rigorous numerical simulation model indicate that results obtained from the proposed equation are conservative.

A Proposal of Baseflow using Discharge Measurement Method in the Streams of Island (도서지역 하천의 기저유출량 산정을 위한 유량측정방법 제안)

  • Lee, Jun-Ho;Yang, Sung-Kee;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.561-569
    • /
    • 2014
  • The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 $m^3/s$, whereas the average ADC and Flowmate is 0.709 $m^3/s$. Meanwhile, stream discharge has been calculated 0.709 $m^3/s$ through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers' strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.

Study on the rainwater recharge model using the groundwater variation and numerical solution of quasi-three dimensional two-phase groundwater flow

  • Tsutsumi, Atsushi;Jinno, Kenji;Mori, Makito;Momii, Kazuro
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2002.05b
    • /
    • pp.1034-1040
    • /
    • 2002
  • A rainwater recharge model, which is combined with the quasi-three dimensional unconfined groundwater flow, is proposed in the present paper. The water budget in the catchments of the planned new campus of Kyushu University is evaluated by the present method that calculates both the surface runoff and groundwater flow simultaneously. The results obtained in the present study reveal that the calculated monthly and annual runoff discharges agree reasonably well with the observed discharge. Combining the rainwater recharge model, the two-phase groundwater flow equation is numerically solved f3r the entire area including the low land where the salt water intrusion is observed. The calculated depth of the salt-fresh interface agrees reasonably well with the observed ones at several cross sections. On the other hand, however, it is found that the calculated water budget remains uncertain because of lack of information on the accurate potential evapotranspiration including rainfall interception. In conclusion, however, it is found that the proposed method is applicable for the areas where the horizontal flow is dominant and the interface is assumed to be sharp.

  • PDF