대규모 그리드 접지전극의 과도접지임피던스의 측정 (The transient grounding impedance measurment of large grid grounding electrodes)

  • 전병욱;이수봉;이봉;이승주;정동철;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF

전위강하법에 의한 접지저항 측정에 미치는 전류보조전극의 위치의 영향 (Effect of the Current Probe Position on Ground Resistance Measurement Using Fall-of-Potential Method)

  • 이복회;엄주홍;김성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1874-1876
    • /
    • 2000
  • In this paper, the effects of the positions of the current probe on the measurements of the ground resistanc, and potential gradients with fall-of-potential method are described, and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of the measuring auxiliary probes. The ground resistance is calculated by applying the 61.8% lute using fall-of-potential method.

  • PDF

접지그리드의 접지임피던스 측정의 정확도 평가 (Evaluation of the Accuracy of Grounding Impedance Measurement of Grounding Grid)

  • 최종혁;최영철;정동철;김동성;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.146-153
    • /
    • 2009
  • 최근 대형 건축물들은 접지그리드를 기반으로 한 공통접지방식을 채택하고 있다. 이러한 접지시스템의 성능평가는 접지저항만으로 불충분하므로 접지임피던스의 측정이 요구된다. 대형 접지시스템의 접지임피던스에 대한 측정 방법은 IEEE standard 81.2에 기술되었으나 세부적인 평가방법들은 제시되지 못한 상태이다. 본 논문은 15[m]$\times$15[m] 접지그리드에 대하여 수정된 전위강하법에 기반한 접지임피던스의 정확한 측정방법과 보조전극의 위치에 따른 도전유도 및 전자유도에 의한 측정오차를 기술한다. 그 결과 도전유도에 의한 오차는 보조전극의 거리가 늘어날수록 감소하였다. 전자유도에 의한 오차를 배제하기 위해서 전위측정선은 전류측정선과 90도를 이루어야 한다. 전위측정선과 전류측정선이 예각 또는 둔각을 이루었을 때 전자유도전압은 각각 + 또는 -를 나타내었다. 일반적으로 전자유도에 의한 오차는 예각에 비해서 둔각의 경로가 작게 나타났다.

접지시스템에서 접촉전압과 보폭전압의 비교측정 (Comparative Measurement of Touch and Step Voltages in Ground Systems)

  • 김황국;문병두;박대원;길경석;한주섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.311-315
    • /
    • 2008
  • Ground systems set the reference voltage level of circuit and system, and suppress Ground Potential Rise (GPR) by flowing fault currents to ground safely. There are several parameters which evaluate the performance of ground systems as ground resistance, touch voltage and step voltage. The touch and step voltages are especially important to ensure safety of human body. In this paper, we measured the touch and step voltages by injection of power frequency and surge current. Also correlation between touch and step voltages is compared and analyzed for the same ground systems.

  • PDF

아두이노 기반 IT융합 스마트 대지저항 측정 기술 연구 (A Study on Smart Ground Resistance Measurement Technology Based on Aduino)

  • 김홍용
    • 한국재난정보학회 논문집
    • /
    • 제17권4호
    • /
    • pp.684-693
    • /
    • 2021
  • 연구목적: 아두이노를 이용하여 실시간 대지저항 데이터를 취득할 수 있는 스마트 대지저항 측정장치를 개발하여 낙뢰 등 이상전압으로부터 안전한 설비환경을 구축하는것에 목적이 있다. 연구방법: 본 논문은 아두이노와 전력선 통신(PLC) 체계를 갖춘 대지저항 취득 및 분석 시스템을 개발하여 설계모델과 적용사례를 연구하였다. 경남지역의 풍력발전 단지 내 일부 부지를 테스트 베드로 선정하여 신기술을 적용한 실시간 대지저항 데이터를 취득하였다. 전극배열은 웨너(Wenner) 4전극배열과 슐렘버거(Schlumberger) 전극배열을 혼용한 스마트 전극배열을 채택하였다. 연구결과: 본 기술의 특징은 첫 번째로 스마트 다 전극의 깊이를 각기 다르게 편성해 층간에 특이성을 가지는 지층 구조에도 취득 데이터의 오차범위를 축소하였다. 두 번째로 스마트 접지전극에서 취득한 대지저항 데이터의 정보를 사물인터넷으로 실시간 송·수신이 가능하도록 IT융합 기술을 적용하였다. 마지막으로 규칙적인 관리 체계를 구축하고 Server에 축적된 빅 데이터를 분석하여 다양한 요소들의 변화추이를 확인할 수 있으며, IT융합 환경에 최적의 접지 알고리즘과 접지시스템 설계 모델링이 가능하다. 결론: 본 기술은 4차 산업 시대에 근간이 되는 도시 기반시설에 낙뢰로 인한 서지(Surge)의 피해를 줄이고 최적화된 접지시스템 모델을 설계하여 사용자의 안전과 생명을 보호 할 것이다. 또한 순수 국산 기술력의 지적재산권을 확보하여 포스트 코로나 시대에 팬데믹으로 정체되어있는 우리산업의 일자리 창출과 활기를 불어넣는 효과도 기대된다.

변전소 접지설계를 위한 접지전극 주변의 위험전압 측정과 분석 (Measurement and Analysis of the Dangerous Voltage Around Grounding Electrode for Safety in Substation Ground)

  • 손석금;김재철
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.214-219
    • /
    • 2011
  • The substation grounding design,"IEEE Guide for Safety in AC Substation Grounding (ANSI / IEEE Std 80)"has been widely used. Substation grounding design and substation grounding resistance of grounding network site to predict the voltage at the risk of a very important task, which is a ground fault current due to the influx of the ground network and due to rise in the Earth's potential can be applied to human dangerous Voltage within safe tolerances be configured to be the ground because the network. IEEE Std. 80 for the substation construction safety equipment on the ground securing the ground electrode and the mesh around the boundary potential distribution in terms of risk analysis by the touch voltage and the reference was to clean up the definition and the basic steps of the voltage of the voltage limits the risk of peripheral grounding electrode Suppression by the simulator through a new secure from dangerous voltage design techniques were presented.

접지침봉에 의한 접지임피던스를 낮추는 방안 연구 (A Study on How to Lower the Grounding Impedance by Needles-typed Grounding Rods)

  • 박성렬
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.19-28
    • /
    • 2022
  • 연구목적: 전기로 인한 화재·폭발·감전 등의 재해를 예방하기 위한 방법 중의 하나가 접지를 시행하는 것이다. 접지전류가 높은 주파수 성분을 포함하는 경우에는 접지저항보다는 접지임피던스를 측정하는 것이 바람직하다. 본 연구에서는 수 kHz 이상의 주파수 성분을 가지는 접지전류에 의한 대지전위상승을 억제하기 위한 접지임피던스를 줄이는 방안을 제시하고자 한다. 연구방법: 대지에 접지동봉과 접지침봉을 매설하여 각각 접지저항과 접지임피던스를 측정하였고, 주파수에 따른 접지임피던스의 특성을 파악하였다. 연구결과: 접지동봉과 접지침봉의 접지저항 측정 결과는 거의 차이가 없었다. 62.5kHz 보다 낮은 주파수 영역에서는 접지동봉이나 접지침봉의 접지임피던스 측정 결과는 거의 차이가 없었으며, 62.5kHz 보다 높은 주파수 영역에서는 접지침봉의 접지임피던스가 접지동봉의 접지임피던스보다 약 15% 정도의 저감효과가 있었다. 결론: 상용주파수 영역에서 접지저항 값을 낮추기 위하여 다수의 접지극을 공통으로 접지하는 것이 효과적이고, 접지임피던스가 낮은 접지침봉을 설치하는 경우 수 kHz 이상의 주파수 성분을 가지는 접지전류에 의한 대지전위상승을 효과적으로 억제할 수 있을 것으로 보인다.

전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향 (Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method)

  • 이복희;엄주홍
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.69-77
    • /
    • 2000
  • 본 논문에서는 찬우$\mid$강하법에 의한 접지저항 및 대지첸위 분표의 측캠시 전휴보조전극의 영향에 대하여 기술하였으며, 측정시 오치를 최소화하는 기법을 제안하였다. 전위강해법은 전위와 천류의 측정에 이론적인 비1깅을 두고 있으며, 측정오차는 주로 측정시 설치하는 보조전극의 위치와 자체저항에 기인한다. 피측정 접지전극의 접지저항은 전위강하법에서 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬 때 61.8[%]법칙을 적용하여 측정한다. 하지만 건물이나 포장도로, 구조물 등이 산재해 있는 도심의 경우에는 현장에서 피측정 접지전극과 전류보조전극 사이에 적결한 이격거리 확보가 불가능하거냐 전류보조전극의 접지저행값이 피측정 챔 지전극에 비하여 큰 값을 가지는 경우가 있다. 파측정 접지천극과 전류보조전극을 충분히 이격시키지 않거나 전류류보조전극의 접지저항값이 피측청 접지전극의 접지저항보다 비정상척으로 큰 경우 접지저항의 측정은 오차를 수반하게 되며, 측정된 접지저항값은 오차즐 보정해 주어야 한다. 본 연구애서 측정대상 전극은 길이 2.4[m]의 봉형 접지전극으호 하였으며, 전류보조전극의 영향을 고려할 때 피측정 접지전극과 전류보조전극의 적정한 이격거리는 피측정 접치전극 길이의 5배 이상으로 하여야 전위보조전극을 사설하기가 용이하며 측정정확도의 확보에 유리하다. 또한 전류보존전극의 접지저항값이 피측정 접지전극의 접지저항값 약 36.5배 이하에서는 거의 오차를 발생시키지 않는다.

  • PDF

접지저항 측정의 61.8%법칙 적용의 맹점과 현실적 접근 방법 (Myth of 61.8% rule and the practical application notices)

  • 이상무;조평동
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2005년도 하계학술대회
    • /
    • pp.259-262
    • /
    • 2005
  • 3점전위강하법을 이용한 접지저항을 측정하는데 있어서 관건이 되는 것은 전류전극에까지 이르는 직선 거리상에서 어느 지점에 접지저항의 참값이 존재하는 지를 찾는데 있다. 그러한 전위점 변화에 영향을 미치는 최대의 변수는 토양의 구성 조건이다. 61.8%법칙은 토양이 균일한 경우의 접지저항 참값을 나타내는 전위점(이하 $R_t$)을 말하는 것이다. 이종 토양구성인 경우 $R_t$는 61.8%에 있지 않으며 이에 대하여는 Dawalibi의 논문에 여러 토양 구성의 기본 모델에 대한 실험적 $R_t$를 제시하고 있다. 이러한 것은 토양의 구성 조건을 안다는 전제하에 적용할 수 있는 것이며 실제의 측정 환경에 있어서 특별히 분석을 하지 않는 한, 토양의 구성이 어떠한 특성으로 이루어져 있는 지를 알고 측정한다는 것은 현실적으로 불가능한 일이다. Dawalibi의 논문을 분석하여 보면 $R_t$에 변이를 일으키는 것은 이종 토양 구성에 의한 대지저항률의 차이에 의한 것임을 알 수 있다. 결론적으로 $R_t$는 대지저항률이 낮은 토양 쪽으로 이동하게 되는데 이것이 전위차 특성 그래프의 기울기상에 변화를 준다. 즉 $R_t$는 전위차 곡선의 기울기에 따라 변화하고 전위차 곡선의 기울기는 인근 토양 구성에 의한 영항을 받으므로 이들의 정량적 상관 관계를 분석하여 원리적 변화 규칙을 정형화하면 굳이 토양의 구성 상태를 알지 않고도 $R_t$를 산출할 수 있는 방법을 도출한 수 있으며 역으로 토양의 구성 특성을 감지할 수 있는 측정 방법을 수립할 수도 있다. 본 논문에서는 이러한 취지의 정량 관계 해석을 통한 현실적 측정 방법을 제공한다.분야 별로 아키텍쳐 정도가 다르게 나타나고 있었다(전자 부품은 분야는 오히려 모듈형에 가까웠음). 비단 항공기 개발과정 뿐만 아니라 다른 산업, 제품에도 적용될 수 있는 틀을 마련함으로써, 기존 연구개발기회에서 산업기술 분석을 통한 체계적 기획으로 전환할 수 있는 새로운 대안을 제시한다. 결과적으로 산업기술의 특성과 구조를 반영한 기술개발 방법론으로 아키텍쳐 이론을 적용할 수 있는 단초를 마련했으며, 이것은 본 논문이 기대하는 바이기도 하다.쁖잖⨀쁖잖⨀/ࠐ쁡잖⨀焆덐瀆倆Ā뫫뫫ĀĀĀĀꪛ䂇잖⨀?잖⨀⁅잖⨀耇잖⨀梷熸ጁ庆䌀―?⨀က䀜徾遖洀ᘘ⼄ⴟᠯЭ⠘

  • PDF

접지시스템 주파수 특성의 측정과 해석 (Measurement and Analysis of Frequency Characteristics of Grounding Systems)

  • 최종기;안용호;구선근;박기준;윤진열;정길조;류보혁;김정훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.248-252
    • /
    • 2004
  • Since DC ground resistance, which is a good index of the performance of a grounding system in low frequency. does not show the performance in transient state. We measured ground impedances in frequency domain ranging from 0.1 Hz to 900 KHz maximum to quantify the transient grounding performance of 4 types of grounding system. Transfer function was derived from the measured frequency-dependant ground impedance of a grounding grid. A simulation has been performed to verify the transfer function using EMTP (Electro-Magnetic Transient Program).