• Title/Summary/Keyword: ground measurement

Search Result 1,562, Processing Time 0.034 seconds

Analysis of Drone Downwash and Droplet Deposition for Improved Aerial Spraying Efficiency in Agriculture (드론 방제 살포 효율 개선을 위한 하향풍 및 액적 퇴적 분포 분석)

  • Lee, Se-Yeon;Park, Jinseon;Lee, Chae-Rin;Choi, Lak-Yeong;Daniel Kehinde Favour;Park, Ji-Yeon;Hong, Se-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.5
    • /
    • pp.51-65
    • /
    • 2024
  • With the advancement of Unmanned Aerial Vehicles (UAV) technology, aerial spraying has been rapidly increasing in the agricultural field. Drones offer many advantages compared to traditional applicators, but they pose challenges such as spray drift risk and spray uniformity. To address these issues, it is essential to understand the characteristics of complex airflow generated by drones and its consequences for the spray performance. This study aims to identify the air velocity distribution of drone downwash and the resulting spray deposition distribution on the ground, ultimately proposing optimized spraying widths and criteria. Experiments were conducted using two agricultural drones with different propeller arrangements under various flight and measurement conditions. The results showed that during hovering, the downward airflow affected the area within a distance of the radius of the blade (R) from the center of the drone. When the drone was flying, the downward airflow was effective up to a distance of 2R. Droplet deposition was concentrated at the center of the drone during hovering. However, during flying, the droplet deposition was more evenly distributed up to the distance of R. The drone downwash and droplet deposition were significantly different during flying compared to the hovering state. At an effective spray width of 3R, the coefficient of variation (CV) was generally less than 16%, indicating a significant improvement in spray uniformity. These findings help optimize effective spraying techniques in drone-based applications.

Analysis of Water Surface Area Change in Reservoir Using Satellite Images (위성영상을 이용한 저수지 수체면적 변화 분석)

  • Kim, Joo-Hun;Kim, Dong-Phil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.629-636
    • /
    • 2024
  • The purpose of this study is to monitor changes in the water surface of reservoirs in verifiable areas in Korea using satellite images and to analyze the water surface area and water storage. The target area of this study is the Daecheong dam of the Geumgang(Riv.), which supplies water to some areas in the Chungcheong area. A study was conducted to detect water surface area by using the Sentinel-1(SAR-C) image and the optical image of Sentinel-2(MSI) among the various observation sensors of satellite images. The correlation between the reservoir's water storage volume, which is ground measurement data, and the extracted water surface area was analyzed. As a result of the analysis, the coefficient of determination(R2) between water surface area and daily storage using SAR images was analyzed to be 0.9242, and in the analysis using Sentinel-2's MSI optical image, it was analyzed to be correlated at 0.8995. In addition, it is analyzed that the water storage volume of the water surface area extracted from the image using the relationship between the water storage volume and the water surface area represents a hydrograph similar to the actual water storage volume. This study is a basic study for the use of satellite images in unmeasured/non-access areas such as North Korea, and plans to conduct a study to analyze annual changes and long-term trends in major dam reservoirs in North Korea by reflecting the results obtained through this study.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF

Thermal Environments of Children's Parks during Heat Wave Period (폭염 시 어린이공원의 온열환경)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.6
    • /
    • pp.84-97
    • /
    • 2016
  • This study was to investigate the user's thermal environments of the children's parks according to pavements and sunscreen types during periods of heat waves. The measurements were conducted at the sand pits, rubber chip pavement, shelters, and green shade ground of the two children's parks located in Jinju, Korea(Chilam: $N\;35^{\circ}11^{\prime}1.4{^{\prime}^{\prim}}$, $E\;128^{\circ}5^{\prime}31.7{^{\prime}^{\prime}}$, elevation 38m, Gaho: $N\;35^{\circ}09^{\prime}56.8{^{\prime}^{\prime}}$, $E\;128^{\circ}6^{\prime}41.1{^{\prime}^{\prime}}$, elevation 24m) over three days during 11-13, August, 2016. The highest ambient air temperatures at the Jinju Meteorological Office during the three measurement days were $35.9{\sim}36.8^{\circ}C$, which corresponded with the extremely hot weather. A series of experiments measured air temperature, relative humidity, wind velocity, black globe temperature, and long-wave and short-wave radiation of the six directions 0.6 m above ground level. The wet bulb globe temperature(WBGT) and the universal thermal climatic index(UTCI) were used to evaluate thermal stress. Surface temperature images of the play equipment were also taken using infrared thermography. Surface temperatures of the play equipment and grounds were used to evaluate burn risk through contact with playground materials. The results showed the following. The maximum air temperatures averaged over 1-hour period for three days were $36.6{\sim}39.4^{\circ}C$. The sun shades reduced those temperatures by up to $2.8^{\circ}C$(green shade) and $1.0^{\circ}C/2.3^{\circ}C$(shelters). The minimum relative humidity values averaged over 1-hour period for three days were 44~50%. The sun shades increased those humidity values by up to 6%(green shade) and 4%/6%(shelters). The risk of heat related illness at the measurement sites of the children's parks were extreme and high in the daytime hours. The maximum WBGT values averaged over a 30-minute period for three days were $31.2{\sim}33.6^{\circ}C$. The sun shades reduced those WBGT values by up to $2.4^{\circ}C$(green shade) and $0.5^{\circ}C/2.1^{\circ}C$(shelters) compared to sandpits, but would not block the risk of heat related illness in the daytime hours. The category of heat stress at the measurement sites of the children's parks were extreme and very strong in the daytime hours. The maximum UTCI values averaged over a 30-minute period for three days were $39.9{\sim}48.1^{\circ}C$. The sun shades reduced those UTCI values by up to $7.8^{\circ}C$(green shade) and $4.1^{\circ}C/8.2^{\circ}C$(shelters) compared to sandpits, but could not lower heat stress category from extreme and very strong to strong and moderate in the daytime hours. According to the burn threshold criteria when skin was in contact with playground materials, the maximum surface temperature of the stainless steels($70.8^{\circ}C$) surpassed three seconds $60^{\circ}C$ threshold for uncoated steel, that of the rubber chip($76.5^{\circ}C$) surpassed five seconds $74^{\circ}C$ threshold for the plastic, that of the plastic slide($68.5^{\circ}C$) and seats($71.0^{\circ}C$) surpassed the one min $60^{\circ}C$ threshold for plastic, respectively. The surface temperatures of shaded play equipment were lower approximately $20^{\circ}C$ than those of play equipment exposed to the sun. Therefore, sun shades can block the risk of burns in daytime hours. Because of the extreme and high risk of heat related illness and extreme and high heat stress at the children's parks during periods of heat waves, parents and administrators must protect children from the use of playgrounds. The risk of burn when contact with play equipments and grounds at the children's parks during periods of heat waves, was very high. The sun shades are essential to block the risk of burn from play equipments and grounds at the children's parks during heat waves.

Construction of X-band automatic radar scatterometer measurement system and monitoring of rice growth (X-밴드 레이더 산란계 자동 측정시스템 구축과 벼 생육 모니터링)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.3
    • /
    • pp.374-383
    • /
    • 2010
  • Microwave radar can penetrate cloud cover regardless of weather conditions and can be used day and night. Especially a ground-based polarimetric scatterometer has advantages of monitoring crop conditions continuously with full polarization and different frequencies. Kim et al. (2009) have measured backscattering coefficients of paddy rice using L-, C-, X-band scatterometer system with full polarization and various angles during the rice growth period and have revealed the necessity of near-continuous automatic measurement to eliminate the difficulties, inaccuracy and sparseness of data acquisitions arising from manual operation of the system. In this study, we constructed an X-band automatic scatterometer system, analyzed scattering characteristics of paddy rice from X-band scatterometer data and estimated rice growth parameter using backscattering coefficients in X-band. The system was installed inside a shelter in an experimental paddy field at the National Academy of Agricultural Science (NAAS) before rice transplanting. The scatterometer system consists of X-band antennas, HP8720D vector network analyzer, RF cables and personal computer that controls frequency, polarization and data storage. This system using automatically measures fully-polarimetric backscattering coefficients of rice crop every 10 minutes. The backscattering coefficients were calculated from the measured data at a fixed incidence angle of $45^{\circ}$ and with full polarization (HH, VV, HV, VH) by applying the radar equation and compared with rice growth data such as plant height, stem number, fresh dry weight and Leaf Area Index (LAI) that were collected at the same time of each rice growth parameter. We examined the temporal behaviour of the backscattering coefficients of the rice crop at X-band during rice growth period. The HH-, VV-polarization backscattering coefficients steadily increased toward panicle initiation stage, thereafter decreased and again increased in early-September. We analyzed the relationships between backscattering coefficients in X-band and plant parameters and predicted the rice growth parameters using backscattering coefficients. It was confirmed that X-band is sensitive to grain maturity at near harvesting season.

Effect of Visual Perception by Vision Therapy for Improvement of Visual Function (시각기능 개선을 위한 시기능훈련이 시지각에 미치는 영향)

  • Lee, Seung Wook;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.491-499
    • /
    • 2015
  • Purpose: This study was to examine how decline of visual function affects visual perception by assessing visual perception after improving visual function through visual training, and observing the change in the cognitive ability of visual perception. Methods: This study analyzes the visual perceptual evaluation (TVPS_R) of 23 children below age 13($8.75{\pm}1.66$) who have visual abnormalities, and improves visual function after conducting vision training (vision therapy) of the children. Results: Convergence increased from average $3.39{\pm}2.52{\Delta}$ (prism) to $13.87{\pm}6.04{\Delta}$ in the measurement of long-distance disparate points, and from average $5.48{\pm}3.42{\Delta}$ to $18.43{\pm}7.58{\Delta}$ in the measurement of short-distance disparate points. Short-distance diplopia points increased from $25.87{\pm}7.33cm$ to $7.48{\pm}2.87cm$, and as for accommodative insufficiency, short-distance blur points increased from $19.57{\pm}7.16cm$ to $7.09{\pm}1.88cm$. In the visual perceptual evaluation performed before and after improving visual function, 6 items except visual memory showed statistically significant improvement. By order of significant improvement, response gap was highest with $17.74{\pm}16.94$(p=0.000) in visual closure, followed by $15.65{\pm}17.11$(p=0.000) in visual sequential-memory, $13.65{\pm}16.63$(p=0.001) in visual figure-ground, $12.74{\pm}18.41$(p=0.003) in visual form-constancy, $6.48{\pm}10.07$ (p=0.005) in visual discrimination, and $4.17{\pm}9.33$(p=0.043) in visual spatial-relationship. In the visual perception quotient that added up these scores, the response gap was $15.22{\pm}8.66$(p=0.000), showing a more significant result. Conclusions: Vision training enables efficient visual processing and improves visual perceptual ability. It was confirmed that improvement of visual function through visual training not only improves abnormal visual function but also affects visual perception of children such as learning, perception and recognition.

Measurement of the Nursing Workload by Patient Classification System in a Secondary Hospital;As a Preliminary Step for Computerization of Nursing Staffing and Scheduling (환자분류에 의한 일개 2차 의료기관의 간호업무량 조사;전산화를 위한 기초작업으로서)

  • Park, Jung-Ho;Joe, Hyon;Park, Hyeoun-Ae;Han, Hye-Rah
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.1
    • /
    • pp.132-146
    • /
    • 1995
  • Even though Korean medical law stipulates that number of patients attended by a nurse is 2.5 for hospitalization and 30 for ambulatory care, the number of patients cared by a nurse per day is much greater than the standard prescribed by the medical law. Current productivity of nurses is not desirable unless the quality of care is considered. And nursing manpower staffing based on neither current nurses' productivity nor standard of medical law cannot respond properly to dynamic situation of the medical services. Under this background, the necessity of more efficient management of nursing manpower occupying 1/3 of total hospital workers has been recognized by many nursing administrators. Many nursing researchers have studied to foretell the nursing manpower objectively on the basis of measured nursing workload according to patient classification as well. Most of These researches, however, have been conducted in the tertiary hospitals, so it is imperative to conduct other researches to predict necessary nursing manpower in the secondary and the primary hospitals. The study was performed to measure nursing workload and predict pertinent nursing manpower to a secondary hospital with 400beds. Nursing workload was surveyed using measuring tool for direct and indirect care hours in a surgical unit and a medical unit. Survey was conducted from Sep.10 to Sep.16 and from Oct.5 to Oct.11, 1994 respectively by two skilled nurses, Subjects were patients, patients' family members and nursing personnels. Results are follows : 1. Patient classification distributed as 22% of class I (mildly ill patient), 57% of class II (moderately ill patient), and 21% of class III (acutely ill patient) in the medical nursing unit, while 23% of class I, 29% of class II, 12% of class III, and 36% of classIV (critically ill patient) in the surgical nursing unit. There was no difference of inpatient number between weekday and weekend. Bed circulation rate was 89% in both units and average patients number per day was 37.4 (total 42beds) in the medical nursing unit, 32.9 (total 37beds) in the medical nursing unit. 2. Direct care hours per day measured as 2.8hrs for class I, 3.3hrs for class II, and 3.5hrs for class III in the medical nursing unit, while 3.1hrs for class I, 3hrs for class II, 2.7hrs for class III, and 2.2hrs for classIV in the surgical nursing unit. Meanwhile, hours for nursing assistant activities per patient by patients' family members were 11mins and 200mins respectively. Direct care hour rate by shift was day 36%, evening 25%, and night 39% in the medical nursing unit, while 40%, 29%, and and 31% respectively in the surgical nursing unit. 3. Measurement and observation activity held 44.2% of direct care activities of nurses and medication 36.7%, communication 11.7%, exercise 1.8%, treatment 1.3%, hygiene 1.3%, elimination and irrigation 1.1%, suction 1%, nutrition 0.5%, thermotherapy 0.3%, oxygen therapy 0.1% in order. 4. Indirect care hours per day were 294.2mins in the medical nursing unit, and 273.9mins in the surgical nursing unit. By shift, evening was the highest in both units. Indirect care hours for each patient were 44.5mins in the medical nursing unit and 46mins in the surgical nursing unit. 5. checking activities including doctor's order, medication, and delivering patients to the next shift occupied 39.7% of indirect care activities, and preparation 26%, recording 23.8%, communication and conference 6.7%, managing equipments 2.1%, messenger activity 1.7% in order. 6. On the ground of these results, nursing manpower needed in a secondary hospital was estimated ; 27 nursing personnels for the medical nursing unit of 37beds, and 20 nursing personnels for the surgical nursing unit of 33beds.

  • PDF

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

The Effect on the Forest Temperature by Reduced Biomass Caused by Natural Forest Thinning (천연림 간벌에 기인한 산림생물량 감소가 산림 내부 온도에 미치는 영향 연구)

  • Kang, Rae-Yeol;Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.3
    • /
    • pp.303-312
    • /
    • 2018
  • This study was conducted to investigate the relationship between the decrease of forest biomass by forest thinning and the change of temperature in the natural forest by measuring forest biomass and temperature before and after forest thinning in the Pusan National University forest where afforestation had been carried out. We intended to investigate the relationship between the forest biomass, estimated by calculating the Basal area, Crown area and Crown volume using the same formula to the same quadrat before and after forest thinning, and the forest temperature. Temperature measurement was carried out on April 20, 2016 through 28 before forest thinning, July 26, 2016 through November 4 around the time of forest thinning, and April 15, 2017 through May 8 after forest thinning. A temperature data logger was installed to point north at the height of 2.0 m above the ground in the center of the quadrat to record data every 10 minutes during the measurement periods. We used the AWS (Automatic Weather Station) data of the Dongnae-gu area located in the nearby city because it was difficult to set the control group since the whole forest was the subject to the forest thinning. The analysis of the relationship between forest biomass change and temperature showed that the change in temperature inside the forest was the greatest in the midday (12:00 - 15: 00) and was highly correlated with the Crown volume in the forest biomass. The temperature increase was much larger (average $1.91^{\circ}C$) 1 year after forest thinning than immediately after forest thinning (average $0.74^{\circ}C$). The comparison of the decrease rate of Crown volume and the increase in temperature showed that the Pitch pine community, which showed the highest decrease of Crown volume by 15.4%, recorded the highest temperature rise of $1.06^{\circ}C$ immediately after forest thinning and $2.49^{\circ}C$ 1 year after forest thinning. The Pitch pine-Korean red pine community, which showed the lowest Crown volume reduction rates with 5.0%, recorded no significant difference immediately after forest thinning but a temperature rise of $0.92^{\circ}C$ 1 year after forest thinning. The results confirmed that the decrease of forest biomass caused by forest thinning led to a rapid increase of the internal temperature. The fact that the temperature increase was more severe after 1 year than immediately after forest thinning confirmed that the microclimate changes due to the removed biomass cannot be recovered in a short time.

Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains (페이퍼드레인 공법에 의한 연약지반의 압밀거동)

  • Lee, Dal Won;Kang, Yea Mook;Kim, Seong Wan;Chee, In Taeg
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.145-155
    • /
    • 1997
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system. 1. The relation of measurement settlement($S_m$) versus design settlement($S_t$) and measurement consolidation ratio($U_m$) versus design consolidation ratio($U_t$) were shown $S_m=(1.0{\sim}1.1)S_t$, $U_m=(1.13{\sim}1.17)U_t$ at 1.0m drain spacing and $S_m=(0.7{\sim}0.8)S_t$, $U_m=(0.92{\sim}0.99)U_t$ at l.5m drain spacing, respectively. 2. The relation of field compressing index($C_{cfield}$) and virgin compression index($V_{cclab.}$) was shown $C_{cfield}=(1.0{\sim}1.2)V_{cclab.}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. Field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio($C_h/C_v$) were $C_h=(2.4{\sim}3.0)C_v$. $C_h=(3.5{\sim}4.3)C_v$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacing. 4. The evaluation of vertical discharge capacity with drain spacing from the results of the consolidation coefficient ratio showed largely superior in case the Mebra drain and Amer drain than other drain materials at 1.0m and 1.5m drain spacing, while the values showed nearly same value in case same drain spacing.

  • PDF