• 제목/요약/키워드: ground measurement

검색결과 1,551건 처리시간 0.03초

황칠나무(Dendropanax morbiferus) 잎 추출물의 LC-MS/MS 분석 및 항산화 효과 (LC-MS/MS analysis and antioxidant activity of Dendropanax morbiferus extract.)

  • 김민정;손재동;양예진;허지웅;이후장;박광일
    • 대한한의학방제학회지
    • /
    • 제32권3호
    • /
    • pp.235-245
    • /
    • 2024
  • Objective : The study's objective is to assess the components of Dendropanax morbifera (DM) utilizing UPLC-MS/MS and assess their antioxidant properties in order to establish fundamental information for quality control of herbal formulations. Methods : The DM leaves were ground into powder and extracted with water at 80℃. The extract was subsequently concentrated and subjected to freeze-drying for subsequent analysis. The LC-MS/MS analysis was performed using a 1260 series HPLC system and a 3200 QTrap tandem mass system in positive ion mode, with detection conducted at 280 nm. The Folin-Ciocalteu method was employed to measure the phenolic content, while a colorimetric method using aluminum chloride was used to determine the flavonoid content, with gallic acid and quercetin as standards, respectively. The evaluation of antioxidant activity was conducted through the measurement of DPPH radical scavenging activity, by adding the DPPH solution to the extract and recording the absorbance at 517 nm. Results : The UPLC-MS/MS analysis identified five polyphenolic compounds in the DM extract, specifically syringin, 6-hydroxyluteolin 7-O-laminaribioside, shaftoside, rutin, and kaempferol-3-O-rutinoside. The extract was found to contain a total phenolic content of 83.106 ± 0.21 mg GAE/g and a total flavonoid content of 87.963 ± 1.014 mg QE/g. The DM extract demonstrated substantial antioxidant properties, resulting in a reduction of DPPH radicals that was evident at concentrations as low as 40 ㎍/㎖. Conclusions : The study determined important polyphenolic compounds in DM and established its considerable antioxidant efficacy. These findings provide evidence for the efficacy of DM in disease prevention related to oxidative stress and establish a foundation for ensuring quality control in herbal preparations.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • 대한자원환경지질학회:학술대회논문집
    • /
    • 대한자원환경지질학회 2001년도 제17차 공동학술강연회 및 춘계학술답사
    • /
    • pp.42-63
    • /
    • 2001
  • 무령왕릉의 보존대책을 수립하기 위하여 누수 현상, 고분구조 벽체거동 상황 및 구조안전점검, 고분 내에 서식하는 조류의 제거, 고분내 습기 및 결로현상 제거를 위한 공기조화시설 등을 포함하는 종합 정밀저사를 1996년 5월 1일 부터 1997년 4월 30일 까지 1년간 수행하였다. 이러한 연구를 수행하기 위하여 기초 지반에 대한 정밀측량, 고분 내외부의 년중 온습도 모니터링, 지반의 내부물성 파악을 위한 지구물리 탐사, 시추 자료에 대한 각종 물성실험, 지반의 투수계수 측정 및 지구화학적 분석을 실시하였다. 고분 내외부에 대한 정밀측량 결과 봉분 중심의 현실 중심보다 북동쪽으로 5m 이격되어 있다. 무령왕릉의 경우는 발굴 당시에도 유사한 분포를 하였으나, 이로 인하여 불균형적인 토압을 발생시키는 원인이 되고 있다. 벽돌깨짐 상황 조사결과 무령왕릉의 조사 대상 벽돌 6025장중 1972년에는 435장 파손되었던 것이 1996년 조사결과 1072장이 파손된 것으로 밝혀져 파손율이 2.5배로 증가하였다. 6호분의 경우는 이보다 더 심하여 벽돌 파손율이 2.9배로 증가하고 있다. 1972년 상황은 약 1450년간 진행된 것이고 1996년의 상황은 불과 24년간 진행된 것임을 감안할 고분이 발굴된 이후 벽돌의 균열은 상당한 가속도로 진행되어 온것이 사실이며 이대로 진행된다면 더욱 더 가속화될 것으로 판단된다. 고분벽체의 거동상태를 계측한 결과 무령왕릉 동측벽의 경우 우기와 건기에 각각 2.95 mm/myr및 1.52 mm/myr의 거동을 보여 우기에 지하수 유입에 의한 지반의 약화로 인하여 건기보다 2배정도 거동하는 양상을 보인다. 한편, 연도 입구의 호벽은 건기에 전실쪽으로 0.43 mm/myr, 연도쪽으로 2.05 mm/myr의 거동을 보여 무령왕릉에서는 가장 심한 거동을 보이고 있다. 6호분의 거동현황은 건기에만 측정된 바, 현실의 동측벽과 서측벽이 각각 벽체 뒤쪽으로 7.44 mm/myr, 현실안쪽으로 3.61 mm/myr의 거동을 보여 조사대상 5호분, 6호분, 7호분, 중 가장 심한 거동을 보이고 있다. 이는 고분 벽돌의 깨짐이 6호분이 가장 심하다는 사실과 무관하지 않은 것으로 판단된다. 봉분내부의 토양층구조에 대한 지오레이다 영상단면을 분석한 결과 무령왕릉 연도상부의 누수지방지층이 심하게 균열되어 있음을 발견하였다. 이 곳은 고분내부로 직접누수가 발생하는 곳이다. 직접누수와 지하수 형태로 유입된 침투수는 고분군 주위의 지반의 함수비를 증가시켜 지반의 지지력을 약화시키고 또한 고분내로 서서히 유입되어 고분내부의 습도를 100%로 유지시키는 주된 원인이다. 이러한 높은 습도는 고분내의 남조류의 번식을 가져왔으며 남조류의 번식은 현재 6호분이 가장 심각하고 7호분이 우려되는 수준이며 5호분은 문제가 없는 것으로 판단된다. 이와 같이 고분군의 발굴후 인위적인 환경변화와 지속적인 강우침투 및 배수 불량의 영향은 고분군의 안정성에 상당한 위험을 초래하였으며, 현 상태는 각 고분에 대한 보강이 불가피한 것으로 판단된다. 고분 벽돌의 깨짐, 고분 벽체의 거동, 조류의 서식등을 포함하여 송산리 고분군에서 발생되고 있는 보존상의 제반 문제점들을 일차적으로 누수 및 침투수에 의한 결과이다. 그러므로 무엇보다도 고분군 내부 및 고분 주변으로의 강우 및 지하수 침투를 막는 차수 대책이 시급한 것으로 판단된다. 또한 이미 발생한 변위가 더 이상 진행되지 않도록 하중을 경감하고 토압의 균형을 이루는 보강대책이 시급한 실정이다. 고분군의 보존대책으로는 고분의 구조안전에 관하여 근본적인 구조변경이 불가피한 직접 보강대책보다 간접적인 보강대책이 바람직한 것으로 판단된다. 간접적 보강대책으로서는 현 봉분규모의 축소, 불균등토압의 조정, 강우침투 방지를 위한 최종복토시스템, 유도배수구의 설치 및 능선 상부로부터의 지하수 차단시설을 포함한다. 이러한 차수대책은 고분군의 제문제를 해결하는 가장 근본적인 대책이라 할 수 있다. 고분내 결로현상 및 습기 제거를 위하여 항온항습장치를 전실에 설치하고 덕트를 통하여 고분내 현실로 순환시키는 방법을 제안하며 외부 온도의 영향을 덜 받게 하기 위하여 전실상부 토양을 현재보다 두껍게 하고 전실의 천정마감재를 열전도도가 낮은 목재로 교체하며 출입문의 이동등을 제안하였다. 금번 조사 연구를 통하여 얻어진 각종 보수 및 보존대책은 고분구조 자체에 가능한 한 최소의 변화를 주면서 가장 시급한 문제점부터 해결하도록 제시되었다. 설계 및 시공단계에서는 보수의 경중을 가려 순서에 입각하여 이루어져야만 하며 설계 및 시공단계에서 고분의 구조안전에 영향을 주지 않도록 각별한 주의가 요망된다. 끝으로, 상기의 보수대책이 실시된 후 이에 대한 평가 및 향후의 영구 보존을 위한 벽체경사 계측, 함수비 및 지하수위 계측, 온습도 측정 등을 포함하는 사후계측시스템은 필수적이라 할 수 있다. 각종 계측자료를 이용한 장기적이고도 세심한 분석을 통하여 완벽한 보존 관리가 이루어져야할 것으로 사료된다.로 사료된다.

  • PDF

폭염 시 어린이공원의 온열환경 (Thermal Environments of Children's Parks during Heat Wave Period)

  • 류남형;이춘석
    • 한국조경학회지
    • /
    • 제44권6호
    • /
    • pp.84-97
    • /
    • 2016
  • 본 연구는 폭염 시 어린이공원 내 포장 및 차양의 유형에 따른 온열환경을 규명하고자 하였다. 이를 위해 진주기상대에서 측정한 일 최고기온이 $35.9{\sim}36.8^{\circ}C$를 나타낸 2016년 8월 11일부터 8월 13일까지 3일간 진주시내 어린이공원 2곳(칠암어린이공원: $N\;35^{\circ}11^{\prime}1.4{^{\prime}^{\prim}}$, $E\;128^{\circ}531.7{^{\prime}^{\prime}}$, 표고: 38m; 가호제12어린이공원: $N\;35^{\circ}09^{\prime}56.8{^{\prime}^{\prime}}$, $E\;128^{\circ}6^{\prime}41.1{^{\prime}^{\prime}}$, 표고: 24m)의 모래밭, 고무칩포장지, 쉘터, 녹음지를 대상으로 미기상을 측정하였다. 미기상환경으로서 지상 60cm 높이에서 기온, 흑구온도, 상대습도, 풍속, 6방향의 장파 및 단파 복사를 측정하였고, 이를 바탕으로 열스트레스 지수인 WBGT와 UTCI를 산정 및 분석하였다. 또한 열화상카메라로 포장면과 놀이시설의 표면온도를 측정하였으며, 이를 바탕으로 단시간 피부접촉시 화상의 위험을 평가하였다. 연구결과는 다음과 같다. 어린이공원의 3일 시간 평균 최고 기온은 $36.6{\sim}39.4^{\circ}C$였으며, 모래밭에 비해 녹음에서 $2.8^{\circ}C$, 쉘터에서 $1.0^{\circ}C$$2.3^{\circ}C$ 낮게 나타났다. 시간 평균 최저 습도는 44~50%였으며, 모래밭이나 고무칩포장지에 비해 녹음에서 6%, 쉘터에서 4% 및 6% 높게 나타났다. 열사병위험지수 WBGT 값에 근거하면 폭염 시 어린이공원의 주간의 열사병 위험도는 높은 또는 극심한 정도로 나타났다. 3일 30분 평균 최고 WBGT 값은 $31.2{\sim}33.6^{\circ}C$였으며, 모래밭에 비해 녹음에서 $2.8^{\circ}C$, 쉘터에서 $2.3^{\circ}C$$1.0^{\circ}C$ 낮게 나타났으나, 차양에 의해서도 열사병 위험을 피할 수는 없었다. 체감더위지수 UTCI 값에 근거하면 폭염 시 어린이공원의 주간의 온열 스트레스의 범주는 매우 강한 또는 극심한 정도로 나타났다. 3일 30분 평균 최고 UTCI 값은 $39.9{\sim}48.1^{\circ}C$였으며, 모래밭에 비해 녹음에서 $7.8^{\circ}C$, 쉘터에서 $8.2^{\circ}C$$4.1^{\circ}C$ 낮게 나타났으나, 차양에 의해서도 극심한 또는 매우 강한 온열 스트레스를 강한 또는 적정한 온열 스트레스로 낮출 수는 없었다. 단시간 피부접촉에 의한 화상 온도 기준에 따르면, 놀이시설 및 포장면의 최고 표면온도가 스텐레스 스틸($70.8^{\circ}C$)은 무도장 철재 3초 $60^{\circ}C$, 고무칩포장($76.5^{\circ}C$)은 플라스틱 5초 $74^{\circ}C$, 청색 플라스틱 미끄럼판($68.5^{\circ}C$)과 앉음판($71.0^{\circ}C$)은 플라스틱 1분 $60^{\circ}C$ 기준을 초과한 것으로 나타났다. 하지만 그늘이 진 놀이시설의 표면온도는 햇빛에 노출된 놀이시설의 표면온도에 비해 $20^{\circ}C$ 내외로 낮게 나타나, 차양에 의해 화상의 위험을 현저하게 개선할 수 있을 것으로 판단된다. 폭염 시에는 어린이공원의 온열환경은 어린이들에게 높거나 극심한 열사병 위험에 빠지게 하고, 매우 강한 또는 극심한 온열 스트레스를 주기 때문에 보호자나 관리자가 어린이들의 어린이공원 이용을 제한해야 한다. 그리고 폭염시에는 어린이공원의 포장면 또는 놀이시설에 의한 화상의 위험이 매우 높으므로 이용 시 주의를 해야 하며, 화상의 예방을 위해서는 차양시설을 적극적으로 도입해야 한다.

X-밴드 레이더 산란계 자동 측정시스템 구축과 벼 생육 모니터링 (Construction of X-band automatic radar scatterometer measurement system and monitoring of rice growth)

  • 김이현;홍석영;이훈열
    • 한국토양비료학회지
    • /
    • 제43권3호
    • /
    • pp.374-383
    • /
    • 2010
  • 본 연구에서는 기상조건에 영향을 받지 않고 레이더산란 측정을 할 수 있는 X-band 안테나 기반 자동관측 시스템을 구축하였다. 이 시스템을 이용하여 벼 생육시기에 따른 편파별 후방산란계수 변화와 벼 생육인자 변화를 관측하고, 후방산란계수와 벼 생육인자와의 관계를 분석을 통해 최적조건의 후방산란계수를 이용한 벼 생육을 추정하였다. 벼 생육시기에 후방산란계수 변화를 관측해 본 결과 생육초기에는 VV-편파가 HH, HV/VH-편파 보다 후방산란계수가 높게 나타났고, 모든 편파별 후방산란계수가 벼 유수형성기 (7월 말경)까지 증가하다가 그 후 감소 한 후 9월 초순이후 다시 증가하는 dual-peak 현상을 뚜렷이 나타났다. 동시에 생육시기에 따른 생체중, 이삭 건물중, 엽면적지수, 초장 등 벼 생육인자들의 생육 변화를 관측해 보았는데 생체중, 엽면적지수, 초장은 6월 중순부터 7월 하순까지 편파별 후방산란계수와의 변화 경향이 비슷하게 나타났고, 이삭 건물중의 경우 특히 VV-편파 후방산란계수가 9월 초순에서 10월 초순까지 변화 경향이 동일하게 나타났다. 편파별 후방산란계수와 벼 생육인자와의 상관관계를 분석한 결과 엽면적지수, 생체중은 6월 중순 (DOY 168)부터 7월 하순 (DOY 209) 시기에 HH-편파 후방산란 계수와 상관관계가 높았고, 초장은 같은 시기에 VV-편파 후방산란계수와 관계가 높게 나타났다. 이삭 건물중의 경우 벼 출수기가 끝나고 결실기로 접어드는 9월 초순 (DOY 244) 부터 10월 초순 (DOY 276) 시기에 VV-편파 후방산란계수와 상관관계가 높게 나타났다. 이 결과를 바탕으로 벼 생육인자와 상관이 높게 나타난 편파별 후방산란계수를 이용하여 벼 생육을 추정하였다. 엽면적지수는 HH-편파 후방산란계수를 이용하여 2007년도 실측값과 2008년도 추정 경험 모형을 비교해본 결과 비교적 오차가 작았고 (RMSE=0.43), 상관관계가 높은 HH-편파 후방산란계수를 이용하여 2007년도 생체중 실측값과 생체중 추정 모형 (2008년도)을 비교해 본 결과 RMSE가 41.0 g $m^{-2}$ 으로 비교적 작은 오차를 보여 생체중 추정 모형의 유효성이 높다는 것이 증명되었다. 또한 초장의 경우 실측값 (2007년)과 초장 추정 모형 (2008년)을 비교 분석한 결과 오차 범위가 비교적 작게 나타났고 (RMSE=6.93 cm), VV-편파 후방산란계수를 이용해 얻은 이삭 건물중 추정 경험 모형 (2008년도)과 2007년도 이삭 건물중 실측값과의 관계를 통해 추정식을 검증한 결과 RMSE=0.35 g/m2 을 보여 이삭 건물중 추정모형의 유효성이 높다는 것이 증명되었다. 본 연구결과에서는 Kim et al. (2009)이 일정한 간격을 두고 수동조건으로 관측한 결과와 비교해서 벼 생육시기에 따른 편파별 후방산란계수 변화 경향이 뚜렷하게 나타났고, 이 후방산란계수를 이용하여 벼 생육인자와의 관계 및 추정 결과에서도 기존 결과보다 상관관계 및 생육추정 모형 유효성이 높게 나타났다. 본 연구 결과를 통해 X-band 산란계 자동측정 시스템을 이용하여 벼 생육을 예측 할 수 있음을 확인하였다.

시각기능 개선을 위한 시기능훈련이 시지각에 미치는 영향 (Effect of Visual Perception by Vision Therapy for Improvement of Visual Function)

  • 이승욱;이현미
    • 한국안광학회지
    • /
    • 제20권4호
    • /
    • pp.491-499
    • /
    • 2015
  • 목적: 시각이상을 가진 아동을 대상으로 시기능훈련을 통한 시각기능이상의 개선 전후 시지각점수의 변화를 살펴보고 시지각에 미치는 영향을 알아보고자 한다. 방법: 시각기능이상을 가진 13세 미만($8.75{\pm}1.66$)의 아동 23명을 대상으로 시기능훈련 전후에 시지각기능검사(TVPS_R; test of visual perceptual skills-revised)를 실시하여 시기능훈련에 따른 시각기능의 변화와 시지각 평가점수의 변화를 분석하였다. 결과: 시기능훈련을 통해서 원거리 PRC(positive relative convergence) 분리점은 평균 $3.39{\pm}2.59{\Delta}$(prism)에서 $13.87{\pm}6.04{\Delta}$로 증가되었고, 근거리 P.R.C 분리점은 평균 $5.48{\pm}3.42{\Delta}$에서 $18.44{\pm}7.58{\Delta}$로 증가하였다. NPC(near point of convergence)는 $25.87{\pm}7.33cm$에서 $7.48{\pm}2.83cm$로 개선되었고, NPA(near point of accommodation)는 $19.57{\pm}7.16cm$에서 $7.09{\pm}1.88cm$로 개선되었다. 시지각평가에서 시각기억분야를 제외하고는 대응차가 시각완성에서 $17.74{\pm}16.94$(p=0.000), 시각적순차기억에서 $15.65{\pm}17.11$(p=0.000), 배경식별에서 $13.65{\pm}16.63$(p=0.001), 형태향상성에서 $12.74{\pm}18.41$(p=0.003), 시각구별에서 $6.49{\pm}10.07$(p=0.005), 시각적공간지각에서 $4.17{\pm}9.33$(p=0.043) 순으로 개선되었고, 이를 종합한 시지각점수는 대응차가 $15.22{\pm}8.66$(p=0.000)로서 더욱 더 유의한 결과를 나타내었다. 결론: 시기능훈련을 통해서 시각기능의 개선과 시각기억분야를 제외한 시지각점수의 향상이 시각완성, 시각적순차기억, 배경식별, 형태향상성, 시각구별, 시각적공간지각 순으로 유의하게 나타났다. 따라서 시각기능향상을 위한 시기능훈련은 시각의 기능뿐만 아니라 시지각의 기능까지 영향을 미치는 것을 확인 할 수 있으며 시각훈련의 중요성을 인식 할 수 있었다.

환자분류에 의한 일개 2차 의료기관의 간호업무량 조사;전산화를 위한 기초작업으로서 (Measurement of the Nursing Workload by Patient Classification System in a Secondary Hospital;As a Preliminary Step for Computerization of Nursing Staffing and Scheduling)

  • 박정호;조현;박현애;한혜라
    • 간호행정학회지
    • /
    • 제1권1호
    • /
    • pp.132-146
    • /
    • 1995
  • Even though Korean medical law stipulates that number of patients attended by a nurse is 2.5 for hospitalization and 30 for ambulatory care, the number of patients cared by a nurse per day is much greater than the standard prescribed by the medical law. Current productivity of nurses is not desirable unless the quality of care is considered. And nursing manpower staffing based on neither current nurses' productivity nor standard of medical law cannot respond properly to dynamic situation of the medical services. Under this background, the necessity of more efficient management of nursing manpower occupying 1/3 of total hospital workers has been recognized by many nursing administrators. Many nursing researchers have studied to foretell the nursing manpower objectively on the basis of measured nursing workload according to patient classification as well. Most of These researches, however, have been conducted in the tertiary hospitals, so it is imperative to conduct other researches to predict necessary nursing manpower in the secondary and the primary hospitals. The study was performed to measure nursing workload and predict pertinent nursing manpower to a secondary hospital with 400beds. Nursing workload was surveyed using measuring tool for direct and indirect care hours in a surgical unit and a medical unit. Survey was conducted from Sep.10 to Sep.16 and from Oct.5 to Oct.11, 1994 respectively by two skilled nurses, Subjects were patients, patients' family members and nursing personnels. Results are follows : 1. Patient classification distributed as 22% of class I (mildly ill patient), 57% of class II (moderately ill patient), and 21% of class III (acutely ill patient) in the medical nursing unit, while 23% of class I, 29% of class II, 12% of class III, and 36% of classIV (critically ill patient) in the surgical nursing unit. There was no difference of inpatient number between weekday and weekend. Bed circulation rate was 89% in both units and average patients number per day was 37.4 (total 42beds) in the medical nursing unit, 32.9 (total 37beds) in the medical nursing unit. 2. Direct care hours per day measured as 2.8hrs for class I, 3.3hrs for class II, and 3.5hrs for class III in the medical nursing unit, while 3.1hrs for class I, 3hrs for class II, 2.7hrs for class III, and 2.2hrs for classIV in the surgical nursing unit. Meanwhile, hours for nursing assistant activities per patient by patients' family members were 11mins and 200mins respectively. Direct care hour rate by shift was day 36%, evening 25%, and night 39% in the medical nursing unit, while 40%, 29%, and and 31% respectively in the surgical nursing unit. 3. Measurement and observation activity held 44.2% of direct care activities of nurses and medication 36.7%, communication 11.7%, exercise 1.8%, treatment 1.3%, hygiene 1.3%, elimination and irrigation 1.1%, suction 1%, nutrition 0.5%, thermotherapy 0.3%, oxygen therapy 0.1% in order. 4. Indirect care hours per day were 294.2mins in the medical nursing unit, and 273.9mins in the surgical nursing unit. By shift, evening was the highest in both units. Indirect care hours for each patient were 44.5mins in the medical nursing unit and 46mins in the surgical nursing unit. 5. checking activities including doctor's order, medication, and delivering patients to the next shift occupied 39.7% of indirect care activities, and preparation 26%, recording 23.8%, communication and conference 6.7%, managing equipments 2.1%, messenger activity 1.7% in order. 6. On the ground of these results, nursing manpower needed in a secondary hospital was estimated ; 27 nursing personnels for the medical nursing unit of 37beds, and 20 nursing personnels for the surgical nursing unit of 33beds.

  • PDF

Flowable Composite Resin의 미세변연누출 및 전단결합강도 (MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

천연림 간벌에 기인한 산림생물량 감소가 산림 내부 온도에 미치는 영향 연구 (The Effect on the Forest Temperature by Reduced Biomass Caused by Natural Forest Thinning)

  • 강래열;홍석환
    • 한국환경생태학회지
    • /
    • 제32권3호
    • /
    • pp.303-312
    • /
    • 2018
  • 본 연구는 숲가꾸기가 시행된 부산대학교 제1학술림을 대상으로 간벌 전 후의 산림생물량 및 온도를 실측하여 천연림에서 간벌에 따른 산림생물량 감소와 산림 내부 온도변화의 관계를 확인하고자 하였다. 산림생물량은 간벌 전 후 동일 조사구에 흉고단면적, 수관단면적, 수관체적을 각각 동일한 도출식을 적용하여 도출하였으며, 산림 온도와의 관계성을 파악하고자 하였다. 온도측정은 간벌 이전인 2016년 04월 20일~28일, 간벌 전후인 2016년 07월 26일~11월 04일, 간벌 이듬해인 2017년 04월 15일~05월 08일에 각각 실시하였으며 온도데이터로거를 방형구 내 중앙에 위치한 수목의 지상 2.0m 높이에 북향으로 설치하여 동일기간동안 각 10분마다 데이터가 기록되도록 설치하였다. 간벌이 산림 전역에 진행되어 산림 내 대조구 설정이 어려워 인근 도시에 위치한 동래구 지역별상세관측자료(AWS)를 대조구로 활용하였다. 산림생물량의 변화와 온도와의 관계성을 분석한 결과, 산림 내부 온도 변화는 한낮 시간대(PM12:00~15:00)에 가장 큰 변화를 보였으며, 산림생물량 중 수관체적과 깊은 관계성을 가지고 있었다. 간벌 직후(평균 $0.74^{\circ}C$)보다 간벌 후 1년이 경과한 시점(평균$1.91^{\circ}C$)에서 훨씬 높은 온도 상승을 보였다. 조사구별 수관체적 감소비율과 온도 상승정도를 비교한 결과, 수관체적 감소량이 15.4%로 가장 높았던 리기다소나무군락에서 간벌 직후와 1년 후 분석에서 각각 $1.06^{\circ}C$, $2.49^{\circ}C$로 가장 높은 온도 상승을 나타냈다. 수관체적 감소비율이 5.0%로 가장 적었던 리기다소나무-소나무군락에서 간벌 직후는 그 차이가 없었으며 1년 후 분석에서는 $0.92^{\circ}C$가 상승하였다. 천연림에서 간벌로 인한 산림생물량 감소는 산림내부 온도를 급격히 상승시키는 것을 확인할 수 있었으며 특히, 간벌 직후보다는 이듬해에 더 극심하게 나타나고 있어 제거된 산림생물량에 의한 미기후 변화는 단기간에 회복될 수 없음을 확인할 수 있었다.

페이퍼드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains)

  • 이달원;강예묵;김성완;지인택
    • 농업과학연구
    • /
    • 제24권2호
    • /
    • pp.145-155
    • /
    • 1997
  • 본 연구는 현재 시공중인 사업부지를 선정하여 시험시공중에 있는 연약지반에서 페이퍼 드레인 공법에 의하여 처리한 지반에서 드레인의 타입간격별 침하거동을 파악하고, 실내시험과 현장계측치로부터 구한 압축지수와 압밀계수를 비교분석하여 배수성능의 우수성을 평가한 것으로 그결과를 요약하면 다음과 같다. 1. 실측침하량($S_m$)과 설계침하량($S_t$)의 관계 및 실측압밀도($U_m$)와 설계압밀도($U_t$)와의 관계는 드레인 타입간격 1.0m에서는 $S_m=(1.0{\sim}1.1)S_t$, $U_m=(1.13{\sim}1.17)U_t$로 나타났고, 드레인 타입간격 1.5m에서는 $S_m=(0.7{\sim}0.8)S_t$, $U_m=0.92{\sim}0.99)U_t$의 범위로 나타났다. 2. 현장압축지수($Cc_{Field}$)와 처녀압축지수($V_{CC_{lab.}}$)와의 관계는 $Cc_{Field}=(1.0{\sim}1.2)V_{CC_{lab.}}$로 나타났으나, 처녀압축지수의 결정밥법과 최종예상 침하량의 적용방법에 따른 오차를 감안하면 거의 동일한 것으로 판단된다. 3. 계측치로부터 역산한 현장압밀계수는 실내시험에서 구한 압밀계수보다 크게 나타났고, 압밀계수비($C_h/C_v$)는 드레인 타입간격 1.0m에서는 $C_h=(2.4{\sim}3.0)C_v$, 드레인 타입간격 1.5m에서는 $C_h=(3.5{\sim}4.3)C_v$의 범위로 타입간격이 넓을수록 크게 나타났다. 4 드레인 타입간격에 따른 드레인 자재별 배수성능 평가기준을 압밀계수비의 결과를 기초로 판단하여 보면, 드레인 타입간격 1.0m에서는 Mebra 드레인, 드레인 타입간격 1.5m에서는 Amer드레인이 약간 우수한 것으로 나타났으나, 동일한 타입간격에서는 재질간의 큰차이가 발생되지 않아 모두 동일한 배수성능을 갖는 것으로 판단된다.

  • PDF

스펙트럼 분석을 응용한 단일 균열 규모확장과 투수계수 산정 (Scaling up of single fracture using a spectral analysis and computation of its permeability coefficient)

  • 채병곤
    • 지질공학
    • /
    • 제14권1호
    • /
    • pp.29-46
    • /
    • 2004
  • 균열을 따른 지하수 유동은 균열 기하양상에 의해 속도와 유동형태가 결정되므로, 암반 내 지하수 유동특성 해석 시 유동경로 역할을 하는 균열의 기하양상을 정확하게 파악하는 것은 중요하다. 그러나, 실제 현장규모에서는 노두의 불연속적 분포와 지표 하 정보의 연속적 획득이 불가능하기 때문에 전체적인 균열 정보를 얻기 어렵다. 따라서, 해석대상 균열 전체양상을 표현할 수 있는 방법의 개발이 요구된다. 이 연구는 퓨리에 변환을 토대로 해석대상 균열의 전체 기하양상을 파악하는 방법을 개발하고자 새로운 접근을 시도하였다. 시추코아로부터 해석대상 균열을 따라 시료를 채취한 후, 각 시료별로 퓨리에 변환을 통해 거칠기 구성성분 중 영향력이 큰 성분을 선택하였다. 그리고, 선정된 성분들을 평균하여 평균 스펙트럼을 구하였다. 평균 스펙트럼은 각 시료의 모든 성분을 포함하고 있으므로, 해석 대상 균열의 거칠기 성분 중 대표성분을 나타낸다. Low pass filtering을 수행한 후, 퓨리에 역변환을 실시하여 평균화 된 전체 균열의 거칠기 형상을 재현하였다. 재현된 거칠기 형상 또한 각 시료의 전체 기하특성을 포함하는 해석대상 지표하 균열의 대표적 거칠기 양상을 나타내는 것이다. 또한, 이는 규모확장을 통한 균열 전체의 거칠기 양상을 의미하는 것이다. 해석대상 균열을 따른 투수계수 특성을 파악하기 위해 재현된 거칠기 양상을 바탕으로 균열모델을 구성하였다. 투수계수는 균열 기하특성을 최대한 반영하여 정확한 투수계수를 구할 수 있는 균질화 해석법을 통해 산정 하였다. 해석결과는 $10^{-4}{\;}and{\;}10^{-3}{\;}cm/sec$ 범위의 투수계수 분포를 보이는데, 이는 큰 규모의 균열을 따른 투수계수 값이라 할 수 있다. 이러한 시도는 전술한 바와 같이 제한된 단속적 균열정보를 이용해 해석대상의 균열전체에 대한 기하양상은 물론 투수계수를 산정 할 수 있는 방법이 될 것이다.도는 매립된 폐기물의 성상과 밀접한 관계를 보이며 해안가를 따라 매립되어 있는 지역의 토양 내 중금속의 용출은 주변 환경에 대한 잠재적인 환경위험을 결정 시 중요한 역할을 한다.로 제거할 수 있는 것으로 나타났다. 오염 지도에 근거하여 산출된 복원 물량에 대하여 토양세척법을 이용하는 경우 복원 비용을 산출하였으며, 이와 같은 자료는 고로폐광산 주변 오염 토양에 대한 실제 복원 공정의 설계에 중요한 자료로 활용될 수 있을 것으로 판단된다.om the sampling and analytical procedures. There is a cost involved in order to improve the precision of sampling and analytical methods so as to decrease the degree of measurement uncertainty. The economical point of compromise in an investigation planning can be achieved when the allowable degree of uncertainty has been set before-hand. The investigation can then be planned accordingly not to exceed the uncertainty limit. Furthermore, if the measurement uncertainty estimated from the preliminary investigation can be separated into sampling and analytical uncertainties, it can be used as a criterion where the resources for the investigation should be allotted cost-effectively to reinforce the weakest link of