• 제목/요약/키워드: ground loads

검색결과 494건 처리시간 0.023초

지반변형률 모형을 이용한 매설관의 지진파 해석 (Seismic Wave Analysis of Buried Pipelines Using Ground Strain Model)

  • 김문겸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.91-98
    • /
    • 1999
  • In this study a modified ground strain model is developed for an equivalent earthquake load and is applied to the seismic analysis of buried pipelines, The ground strain can be obtained using the ratio of a maximum ground velocity to a wave propagation velocity. To reflect soil conditions and seismic characteristics the wave propagation velocity is evaluated by a proposed dispersion curve based on wave energy distribution. In order to verify the procedures the observed earthquake data and the results of this study are compared. For the application of an equivalent earthquake load to the seismic analysis the buried pipelines are modeled using the beam theory. the results of the analyses are compared with those of a dynamic analysis code and those obtained from the response displacement method. Finally various parametric studies considering different soil conditions and seismic loads are examined.

  • PDF

Moment resisting steel frames under repeated earthquakes

  • Loulelis, D.;Hatzigeorgiou, G.D.;Beskos, D.E.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.231-248
    • /
    • 2012
  • In this study, a systematic investigation is carried out on the seismic behaviour of plane moment resisting steel frames (MRF) to repeated strong ground motions. Such a sequence of earthquakes results in a significant damage accumulation in a structure because any rehabilitation action between any two successive seismic motions cannot be practically materialised due to lack of time. In this work, thirty-six MRF which have been designed for seismic and vertical loads according to European codes are first subjected to five real seismic sequences which are recorded at the same station, in the same direction and in a short period of time, up to three days. Furthermore, the examined frames are also subjected to sixty artificial seismic sequences. This investigation shows that the sequences of ground motions have a significant effect on the response and, hence, on the design of MRF. Additionally, it is concluded that ductility demands, behaviour factor and seismic damage of the repeated ground motions can be satisfactorily estimated using appropriate combinations of the corresponding demands of single ground motions.

학교 건물용 지열 히트펌프 시스템 설계와 지중 순환수 온도 변화 분석 (Design of Ground-Coupled Heat Pump (GCHP) System and Analysis of Ground Source Temperature Variation for School Building)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Ground-coupled heat pump (GCHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. Although some experimental and simulation works related to performance analysis of GCHP systems for commercial buildings have been done, relatively little has been reported on the performance evaluation of GCHP systems for school buildings. The purpose of this simulation study is to evaluate the performance of a hypothetical GCHP system for a school building in Seoul. We collected various data of building specifications and construction materials for the building and then modeled to calculate hourly building loads with SketchuUp and TRNSYS V17. In addition, we used GLD (Ground Loop Design) V2016, a GCHP system design and simulation software, to design the GCHP system for the building and to simulate temperature of circulating water in ground heat exchanger. The variation of entering source temperature (EST) into the system was calculated with different prediction time and then each result was compared. For 20 years of prediction time, EST for baseline design (Case A) based on the hourly simulation results were outranged from the design criteria.

수평하중을 받는 콘크리트말뚝의 모형실험 (Model Tests of Concrete Pile under Lateral Loads)

  • 박종운;김진복;진홍민;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.580-586
    • /
    • 2010
  • The purpose of this study is to analyze the behavior of the concrete pile under the horizontal loads by the model tests in laboratory. The rock ground was modeled by the concrete of about 30MPa, and a model pile was made of some mortar with the capacity of 24MPa. The diameter(D) and length(L) of a model pile was each 1200mm and 1800mm. The embedment depth into the concrete block was varied with 1.0D, 1.5D, and 2.0D in the model tests. The results of model tests showed that the lateral resistance of a pile with the embedment depth of 2.0D was more large than other cases, and the lateral displacement of yielding was similar.

  • PDF

A review of seismic design recommendations in Jordan

  • Saffarini, Hassan S.
    • Structural Engineering and Mechanics
    • /
    • 제9권3호
    • /
    • pp.257-268
    • /
    • 2000
  • The seismic design recommendations of the Jordan Code for Loads and Forces (JC) are evaluated, based on comparisons with analytical studies and the Uniform Building Code. It was established that the overall safety ensured by the implementation of these recommendations is not consistent with the established seismic risk in Jordan and the intended objectives of the code. A new zoning map is proposed with effective peak ground acceleration values. The different period formulae of the code were studied and were found to grossly underestimate the fundamental period when compared with analytically derived values or other codes' formulae. Other factors including the dynamic, soil, importance and behavior factors are discussed. It was determined that the JC's lateral load distribution formulae clearly lead to smaller internal forces than both dynamic analysis and UBC loads, even when those loads are normalized to give the same base shear. The main reason for this is attributed to the limited allowance for a backlash force in the JC.

Some practical considerations in designing underground station structures for seismic loads

  • Gu, Jianzhong
    • Structural Engineering and Mechanics
    • /
    • 제54권3호
    • /
    • pp.491-500
    • /
    • 2015
  • Under seismic loading, underground station structures behave differently from above ground structures. Underground structures do not require designated energy dissipation system for seismic loads. These structures are traditionally designed with shear or racking deformation capacity to accommodate the movement of the soil caused by shear waves. The free-field shear deformation method may not be suitable for the design of shallowly buried station structures with complex structural configurations. Alternatively, a station structure can develop rocking mechanisms either as a whole rigid body or as a portion of the structure with plastic hinges. With a rocking mechanism, station structures can be tilted to accommodate lateral shear deformation from the soil. If required, plastic hinges can be implemented to develop rocking mechanism. Generally, rocking structures do not expect significant seismic loads from surrounding soils, although the mechanism may result in significant internal forces and localized soil bearing pressures. This method may produce a reliable and robust design of station structures.

항공기 착륙장치 동하중 해석 (Dynamic Load Analysis of Aircraft Landing Gear)

  • 신정우;김태욱;황인희
    • 한국항공운항학회지
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 2008
  • Role of landing gear is to absorb energy which is generated by aircraft ground maneuvering and landing. Generally, in order to absorb the impact energy, oleo-pneumatic type shock absorber is used in aircraft landing gear. Oleo-pneumatic type shock absorber has a good energy absorption efficiency and is light in weight because structure of oleo-pneumatic type shock strut is relatively simple. In this study, dynamic load analysis for swinging arm type landing gear was performed to predict landing loads. Modeling of landing gear was conducted with MSC.ADAMS, and dynamic landing loads were analyzed based on ADS-29. Optimum landing loads were generated through adjustment of damping orifice and the analysis results were presented with various aircraft attitude.

  • PDF

Estimation for Primary Tunnel Lining Loads

  • 김학준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1998년도 터널.암반역학위원회 박사학위 논문집
    • /
    • pp.153-204
    • /
    • 1998
  • Prediction of lining loads due to tunnelling is one of the major issues to be addressed in the design of a tunnel. The objective of this study is to investigate rational and realistic design loads on tunnel linings. factors influencing the lining load are summarized and discussed. The instruments for measuring the lining loads are reviewed and discussed because field measurements are often necessary to verify the design methods. Tunnel construction in the City of Edmonton has been very active for storm and sanitary purposes. Since the early 1970's, the city has also been developing an underground Light Rail Transit system. The load measurements obtained from these tunnels are compared with the results from the existing design methods. However, none of the existing methods are totally satisfactory, Therefore, there is some room for improvement in the prediction of lining loads. The convergence-confinement method is reviewed and applied to a case history of a tunnel in Edmonton. The convergence curves are obtained from 2-D finite element analyses using three different material models and theoretical equations. The limitation of the convergence-confinement method is discussed by comparing these curves with the field measurements. Three-dimensional finite element analyses are performed to gain a better understanding of stress and displacement behaviour near the tunnel face. An improved design method is proposed based on the review of existing design methods and the performance of numerical analyses. A specific method or combination of two different methods is suggested for the estimation of lining loads for different conditions of tunnelling. A method to determine the stress reduction factor is described. Typical values of dimensionless load factors nD/H for tunnels in Edmonton are obtained from parametric analyses. Finally, the loads calculated using the proposed method are compared with field measurements collected from various tunnels in terms of soil types and construction methods to verify the method. The proposed method gives a reasonable approximation of the lining loads. The proposed method is recommended as an approximate guideline for the design of tunnels, but the results should be confirmed by field measurements due to the uncertainties of the ground and lining properties and the construction procedures, This is the reason that in-situ monitoring should be an integral part of the design procedure.

  • PDF

CFD simulations of the flow field of a laboratory-simulated tornado for parameter sensitivity studies and comparison with field measurements

  • Kuai, Le;Haan, Fred L. Jr.;Gallus, William A. Jr.;Sarkar, Partha P.
    • Wind and Structures
    • /
    • 제11권2호
    • /
    • pp.75-96
    • /
    • 2008
  • A better understanding of tornado-induced wind loads is needed to improve the design of typical structures to resist these winds. An accurate understanding of the loads requires knowledge of near-ground tornado winds, but observations in this region are lacking. The first goal of this study was to verify how well a CFD model, when driven by far field radar observations and laboratory measurements, could capture the flow characteristics of both full scale and laboratory-simulated tornadoes. A second goal was to use the model to examine the sensitivity of the simulations to various parameters that might affect the laboratory simulator tornado. An understanding of near-ground winds in tornadoes will require coordinated efforts in both computational and physical simulation. The sensitivity of computational simulations of a tornado to geometric parameters and surface roughness within a domain based on the Iowa State University laboratory tornado simulator was investigated. In this study, CFD simulations of the flow field in a model domain that represents a laboratory tornado simulator were conducted using Doppler radar and laboratory velocity measurements as boundary conditions. The tornado was found to be sensitive to a variety of geometric parameters used in the numerical model. Increased surface roughness was found to reduce the tangential speed in the vortex near the ground and enlarge the core radius of the vortex. The core radius was a function of the swirl ratio while the peak tangential flow was a function of the magnitude of the total inflow velocity. The CFD simulations showed that it is possible to numerically simulate the surface winds of a tornado and control certain parameters of the laboratory simulator to influence the tornado characteristics of interest to engineers and match those of the field.

선행하중과 Wick Drain공법에 의한 연약해성광토의 개량 (Improvement of Soft Marine Clay by Preloading and Wick Drain Method)

  • 유태성;박광준
    • 한국지반공학회지:지반
    • /
    • 제3권1호
    • /
    • pp.7-24
    • /
    • 1987
  • 울산만 북서측 임해지역체 발달된 연약해성점토를 개양하기 위하려 선행대중과 Wick Drain공법의 병용공법이 적용되었다. 상기 공법의 적용에 따른 연약해성점토의 거동 및 강침특성을 요명하여, 안전하고 신속하게 시공을 실시하기 위하여 현장계측에 의한 공학적인 시공관리를 실시하였다. 본 고는 연약해성점토를 개량하기 위하여 적용한 선행하중과 Wick Drain공법의 설계, 시공 및 안전관리방법을 수록하고 있다.

  • PDF