• Title/Summary/Keyword: ground connection

Search Result 310, Processing Time 0.029 seconds

A Study on the efficiency of AM Broadcast Transmitting Antenna in assordance with a low noise Area (저잡음지역(3.5mV/m)의 AM방송송신 안테나 효율에 관한 연구)

  • 이문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.5 no.1
    • /
    • pp.40-43
    • /
    • 1980
  • The Service area in AM Broadcast Changes according to its transmitting frequency. It is also reduced by increase of the citizen noise. As a result, the efficency of transmitting Antenna should be higer in a low noise region as long as AM Broadcast does not build up its transmitting power. The efficiency of transmitting Antenna can also function as a low resistance connection to earth. Most Vertical Antenna used in the AM standard Broadcast band in the Korea have extensive radial ground systems beneath them which serve as image plane.

  • PDF

Evaluation of energy response of space steel frames subjected to seismic loads

  • Ozakgul, Kadir
    • Structural Engineering and Mechanics
    • /
    • v.54 no.4
    • /
    • pp.809-827
    • /
    • 2015
  • In this paper, seismic energy response of inelastic steel structures under earthquake excitations is investigated. For this purpose, a numerical procedure based on nonlinear dynamic analysis is developed by considering material, geometric and connection nonlinearities. Material nonlinearity is modeled by the inversion of Ramberg-Osgood equation. Nonlinearity caused by the interaction between the axial force and bending moment is also defined considering stability functions, while the geometric nonlinearity caused by axial forces is described using geometric stiffness matrix. Cyclic behaviour of steel connections is taken into account by employing independent hardening model. Dynamic equation of motion is solved by Newmark's constant acceleration method in the time history domain. Energy response analysis of space frames is performed by using this proposed numerical method. Finally, for the first time, the distribution of the different energy types versus time at the duration of the earthquake ground motion is obtained where in addition error analysis for the numerical solutions is carried out and plotted depending on the relative error calculated as a function of energy balance versus time.

A Study on the Stability for the Railroad Bed and the Foundation Ground (High Landfill Slope) (철도노반과 기초지반(고성토사면) 안정에 관한 연구)

  • Oh, Myoung-Ryoul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1391-1404
    • /
    • 2006
  • Recently, medium or slight earthquakes was occurred in the Korea Peninsula and seismic design is considered seriously in the railroad facilities as case of other civil engineering facilities. In this study, it selected the Seongnam-Yeoju railroad 6th section and seismic analysis was accomplished. Specially, unlike existing seismic analysis using the artificial earthquake and the real earthquake, seismic analysis using a seismic vibration and the train vibration was accomplished. 1-D and 2-D ground response analysis of the railroad bed and 3-D Finite element analysis in the bridge connection section of high landfill slope was accomplished. Also, slope stability analysis and the evaluation of liquefaction was accomplished.

  • PDF

A Study on Parenting Attitude of Juvenile Delinquent Parents (비행 청소년 부모의 양육태도 연구)

  • Kang, Young-Ja;Kim, Yun-Hee
    • Korean Journal of Human Ecology
    • /
    • v.8 no.2
    • /
    • pp.245-254
    • /
    • 1999
  • The purpose of this study was to investigate parenting attitude of juvenile delinquent parents. The subjects ware 95 boys and 60 girls. According to the parenting attitude of juvenile delinquent on the ground of sex, fathers' parenting attitude showed connective relation with permissive and democratic attitude. Also in term of home environment, mothers' age, place of growth and fathers' job had the connection of overcaring. Though correlative with parenting attitude of juvenile delinquent, consistent parenting attitude was showed.

  • PDF

The method of ground connection system design due to the difference of earth restivity (대지저항률 변화에 따른 접지설계 기법)

  • Han, C.D.;Choi, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.224-225
    • /
    • 2006
  • 접지설비는 전력계통의 안정적인 운전을 유지하고 사고시 고장전류를 대지로 안전하게 방전시켜 사람과 전기설비의 안전을 확보하는 데 그 목적이 있다. 접지설계시 대지저항률은 중요한 설계인자로 대지저항률 변동에 따른 접지설계 방법을 접지 설계프로그램을 이용하여 비교, 분석하였다.

  • PDF

Water tank simulation of the Grounding Plate Electrodes that is laid under the ground horizontally (수평으로 매설되는 판상접지극의 수조 시뮬레이션)

  • Koh, Hee-Seog;Song, Won-Pyo;Lee, Soo-Jeong;Kim, Maeng-Hyun;Park, Seung-Jae;Ryoo, Hee-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.277-279
    • /
    • 2003
  • Theory calculation way because verification is lacking, we compare and analyzed with calculation theory value and experiment value that is noted through a water tank model experiment based on connection theory way that is announced in existing.

  • PDF

Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL (3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

Risk evaluation of steel frames with welded connections under earthquake

  • Song, Jianlin;Ellingwood, Bruce R.
    • Structural Engineering and Mechanics
    • /
    • v.11 no.6
    • /
    • pp.663-672
    • /
    • 2001
  • Numerous failures in welded connections in steel moment-resisting building frames (SMRF) were observed when buildings were inspected after the 1994 Northridge Earthquake. These observations raised concerns about the effectiveness of such frames for resisting strong earthquake ground motions. The behavior of SMRFs during an earthquake must be assessed using nonlinear dynamic analysis, and such assessments must permit the deterioration in connection strength to capture the behavior of the frame. The uncertainties that underlie both structural and dynamic loading also need to be included in the analysis process. This paper describes the analysis of one of approximately 200 SMRFs that suffered damage to its welded beam-to-column connections from the Northridge Earthquake is evaluated. Nonlinear static and dynamic analysis of this SMRF in the time domain is performed using ground motions representing the Northridge Earthquake. Subsequently, a detailed uncertainty analysis is conducted for the building using an ensemble of earthquake ground motions. Probability distributions for deformation-related limit states, described in terms of maximum roof displacement or interstory drift, are constructed. Building fragilities that are useful for condition assessment of damaged building structures and for performance-based design are developed from these distributions.

Analysis of Fire Accident on DC Electric Traction Vehicles Caused by Breakdown in the Line Breaker (회로 차단기 절연파괴로 인한 직류 전기철도 화재 사고사례 분석)

  • Park, Nam-Kyu;Song, Jae-Yong;Goh, Jae-Mo;Kim, Jin-Pyo;Nam, Jung-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.16-21
    • /
    • 2017
  • Fire or electrical problem while DC electric traction vehicle operation caused by various reasons can lead to not only suspension of the operation, but also severe aftermath such as massive casualty. In this paper, fire analysis on DC electric traction vehicle caused by electrical breakdown on line breaker, which is in connection with the power supply, is presented. When the electric arc, the by-product of frequent line breaker operation, is not fully diminished, it leads to electrical breakdown and fire. Especially, electrical breakdown can be easily induced by the open-and-close operation of inner contractor inside line breaker, eventually followed by ground fault and generation of transient current. Electric arc is consequent on the ground fault and acts as possible ignition source, leading to fire. Also, during the repetitive operation of the line breaker, the contactor is separated each other and some copper powder is generated, and the copper powder provided breakdown path, resulting in fire.

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.