• 제목/요약/키워드: ground

검색결과 22,655건 처리시간 0.042초

22.9[kV] 다중접지 배전계통에서 고장전류의 접지저항 영향 분석 (The Effect by Grounding Resistance of the ground Fault in the 22.9[kV] Multi-ground Distribution System)

  • 정금영;최선규;심건보;김경철
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.85-89
    • /
    • 2010
  • During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multi-grounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A effect by grounding resistance of poles of ground fault current in the 22.9[kV] multi-ground distribution system. by field tests.

봉상 접지전극에시 전류유입위치에 따른 임펄스 접지임피던스의 특성 (Behaviors of Impulse Ground Impedances Associated with the Current Injection Point in a Ground Rod)

  • 이복희;정동철;이수봉
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.94-100
    • /
    • 2005
  • 본 논문은 전류유입위치에 따른 봉상접지전극의 과도 및 실효임펄스임피던스의 특성에 관한 것으로 뇌격전류를 인가하여 실규모 접지봉에 대한 시간영역에서의 성능을 평가하였다. 임펄스전류가 가해진 봉상접지전극의 과도 접지임피던스는 접지저항보다 높게 나타났으며, 접지전극의 길이가 길어짐에 따라 접지저항과 실효임펄스접지임피던스는 감소되었다. 또한 실효임펄스접지임피던스는 짧은 시간범위에서는 급격하게 증가하였다. 접지저항의 저감은 접지시스템의 임펄스임피던스 특성의 개선에 결정적인 역할을 한다. 임펄스전류를 접지봉의 하단에 인가하였을 때 접지봉 전위의 파두부에 고주파의 진동 파형이 포함되고 실효임펄스임피던스는 다른 경우보다 높게 나타났다.

개방형 지열히트펌프 시스템의 성능평가 (Performance Evaluation of Open-Loop Ground Water Heat Pump system)

  • 김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.9-14
    • /
    • 2006
  • Open loop or ground water heat pump systems are the oldest of ground-source systems. Standing column wells can be used as highly efficient ground heat exchanger in geo-thermal heat pump systems, where hydrological and geological conditions are suitable. These systems require some careful considerations for well design, ground water flow, heat exchanger selection etc This paper describes 9round water temperature variations, performances in heat ins and cool ing mode and the results of ground water analysis.

  • PDF

Coupled foot-shoe-ground interaction model to assess landing impact transfer characteristics to ground condition

  • Kim, S.H.;Cho, J.R.;Choi, J.H.;Ryu, S.H.;Jeong, W.B.
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.75-90
    • /
    • 2012
  • This paper investigates the effects of sports ground materials on the transfer characteristics of the landing impact force using a coupled foot-shoe-ground interaction model. The impact force resulting from the collision between the sports shoe and the ground is partially dissipated, but the remaining portion transfers to the human body via the lower extremity. However, since the landing impact force is strongly influenced by the sports ground material we consider four different sports grounds, asphalt, urethane, clay and wood. We use a fully coupled 3-D foot-shoe-ground interaction model and we construct the multi-layered composite ground models. Through the numerical simulation, the landing impact characteristics such as the ground reaction force (GRF), the acceleration transfer and the frequency response characteristics are investigated for four different sports grounds. It was found that the risk of injury, associated with the landing impact, was reduced as the ground material changes from asphalt to wood, from the fact that both the peak vertical acceleration and the central frequency monotonically decrease from asphalt to wood. As well, it was found that most of the impact acceleration and frequency was dissipated at the heel, then not much changed from the ankle to the knee.

지역필터를 이용한 수변전실 접지저항의 새로운 측정방법 (A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations)

  • 이복희;엄주홍;이승칠;김성원;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Effects of Corn Processing on In Vitro and In Situ Digestion of Corn Grain in Holstein Steers

  • Lee, S.Y.;Kim, W.Y.;Ko, J.Y.;Ha, J.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권6호
    • /
    • pp.851-858
    • /
    • 2002
  • This study was conducted to determine effects of whole (intact), coarsely-ground (4 mm), finely-ground (1 mm), steam-flaked and steam-flaked-ground (1 mm) corns on in vitro and in situ DM digestibilities and also in vitro fermentation characteristics. After 48 h incubation, in vitro dry matter digestibilities of whole, steam-flaked, coarsely-ground, steam-flaked-ground, and finely-ground corns were 6.79, 61.68, 76.48, 85.72 and 90.31%, respectively. Steam-flaked-ground corn showed the highest digestibility until 24 h incubation (p<0.01). After 48 h incubation, pH of whole corn decreased with a small range. However the values of pH of other media significantly decreased (p<0.01). The gas productions of finely-ground and steam-flaked-ground corns were higher than those of the other corns (p<0.01). After 24 h incubation, $NH_3$-N concentration of finely-ground and steam-flaked-ground corns increased rapidly. Total VFA was the highest in finely-ground corn, followed by steam-flaked-ground, steam-flaked, coarsely-ground and whole corns. Incorporating steam-flaked corn resulted in the highest propionate concentration (p<0.01) and the lowest acetate : propionate value (p<0.05). Finely-ground corn showed the highest in situ DM digestibility throughout the incubation period (p<0.01), followed by coarsely-ground, steam-flaked and whole corns, respectively. Overall, DM of whole corn was merely digested in vitro as well as in situ.

다양한 다층 지반모형에 대한 지진동 증폭 (Earthquake Amplification for Various Multi-Layer Ground Models)

  • 정수근;김호연;김대현
    • 지질공학
    • /
    • 제33권2호
    • /
    • pp.293-305
    • /
    • 2023
  • 지진이 발생할 때 대한 지진동 증폭 현상을 확인하기 위해 1g 진동대와 연성토조(Laminar Shear Box, LSB)를 이용하여 모형지반을 조성하였고, 3가지 모델에 대하여 지진동 증폭현상에 대하여 확인하였다. 3가지의 모형지반을 선정하였으며 모든 모형지반에서 조밀한 층과 느슨한 층으로 나누었고, 지반모형의 경우는 다층 수평지반, 다층 제방지반, 다층 분지지반모형으로 선정하였다. 각 지반모형을 제작하며 가속도계 매설을 진행하였으며, 인공지진파, Sinesweep파와 Sine 10 Hz의 지진파를 통하여 증폭현상을 확인하였다. 최대지반가속도(Peak ground acclelration, PGA)와 응답스펙트럼 가속도(Spectrum acceleration, SA)를 통해 지진동 증폭현상을 확인하였다. 수평 다층지반에서 조밀한 지반을 통과 후 느슨한 지반에서 가속도 증폭이 조밀한 지반에 비해 크게 발생하는 것을 확인할 수 있었으며, 다른 두 모형지반에서는 층의 경계면을 통과 후 점차 중심부에서 가속도 증폭이 더 크게 발생하는 것을 확인할 수 있었다.

Customizing Ground Color to Deliver Better Viewing Experience of Soccer Video

  • Ahn, Il-Koo;Kim, Young-Woo;Kim, Chang-Ick
    • ETRI Journal
    • /
    • 제30권1호
    • /
    • pp.101-112
    • /
    • 2008
  • In this paper, we present a method to customize the ground color in outdoor sports video to provide TV viewers with a better viewing experience or subjective satisfaction. This issue, related to content personalization, is becoming critical with the advent of mobile TV and interactive TV. In outdoor sports video, such as soccer video, it is sometimes observed that the ground color is not satisfactory to viewers. In this work, the proposed algorithm is focused on customizing the ground color to deliver a better viewing experience for viewers. The algorithm comprises three modules: ground detection, shot classification, and ground color customization. We customize the ground color by considering the difference between ground colors from both input video and the target ground patch. Experimental results show that the proposed scheme offers useful tools to provide a more comfortable viewing experience and that it is amenable to real-time performance, even in a software-based implementation.

  • PDF

干拓地 植物의 無機營養素 蓄積에 對하여 (On the Accumulation of Minerals with the Plant Species in a Reclaimed Land)

  • Min, Byeong Mee
    • The Korean Journal of Ecology
    • /
    • 제13권1호
    • /
    • pp.9-18
    • /
    • 1990
  • For reaserching the factors of plants micro-distribution, accumulation of 5 minerals-total-nitrogen, phosphorus, potassium, sodium and calcium-for 19 plant species was investigated in reclaimed land, in western coast of Korea, In the five minerals, sodium contents were quite different among the species. Plant species were divided into 4 groups based on the sodium accumulation and accumulation site in plant tissue: Na accumultion type above-ground part>below-ground part : Triglochin maritimum, Chenopodium virgatum, Atriplex subcordata, Salicornia herbacea, Suaeda japonica, suaeda asparagoides, Limonium tetragonum, Aster tripolium, Artemisia scoparia, Sonchus brachyotus above-ground partbelow-ground part : Zoysia sinica, amagrostis epigeiosa bove-ground part

  • PDF

고주파수 영역에서 심매설 접지전극의 접지임피던스 (Ground impedance of deeply driven rod in high frequency domain)

  • 이복희;이태형;이수봉;정현욱;정동철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.247-250
    • /
    • 2004
  • A ground resistance is a good index of performance in a grounding system, but it does not reflect the performance in transient states. Recently long vertical ground rods in urban areas are often installed. But because of the inductance of long ground rods the ground impedance at high frequency might be greater than its resistance at low frequency. In this paper, a ground impedance of deeply driven ground rod has been measured in the frequency range from 10 kHz to 50 MHz. As a result, the ground impedances of a deeply driven ground rods are almost constant at the frequency range less than 100 kHz. However at high frequency the ground impedance showed the strong frequency dependance.

  • PDF