• 제목/요약/키워드: grinding methods

검색결과 235건 처리시간 0.022초

Methodological validation of measuring Hanwoo hair cortisol concentration using bead beater and surgical scissors

  • Nejad, Jalil Ghassemi;Ataallahi, Mohammad;Park, Kyu-Hyun
    • Journal of Animal Science and Technology
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2019
  • Different methodologies in hair cortisol extraction may alter the final output. Thus finding the standard methodology according to a laboratory facilities is pivotal. This study was carried out to validate the feasibility of two methods of grinding hair for cortisol extraction in Korean native (Hanwoo) cattle. Hair from nine cattle including mature cows, heifers, and calves were assigned to one of the following methods for grinding hair; 1) using bead beater (BB) and 2) using surgical scissors (SS). Hair samples (> 1 g) were harvested from forehead of each individual twice (first and second measurement) to validate the results. To improve the accuracy of the obtained data, each sample was duplicated into two wells during enzyme immunoassay (EIA) analysis. Overall comparison of hair cortisol concentration (HCC) showed that the data within the range (out of the range) of standards provided by the EIA kit were 88.9% (11.1%) and 66.7% (33.3%) for BB compared with SS, respectively. In the first measurement, application of BB was tended to show higher (p = 0.056) amount of HCC compared with SS. In the second measurement application of BB showed higher (p = 0.0028) amount of HCC compared with SS. Among the cattle, calves showed higher HCC using BB compared with SS (p < 0.05). Application of BB in hair grinding methodology for Hanwoo cattle may improve cortisol extraction in comparison to application of SS method, with more consistency. Thus, it would be the preferable method to use.

평면연삭(平面硏削)에서 주파수(周波數) 분석(分析)에 의한 표면(表面) 거칠기 해석(解釋) (A Study on the Surface Roughness in Grinding Process by Frequency Analysis)

  • 김경년;정재천;김기선
    • 비파괴검사학회지
    • /
    • 제11권2호
    • /
    • pp.32-41
    • /
    • 1991
  • This paper is to analyze the surface roughness in wet and dry surface grinding in which working conditions are table feed, cross feed and down feed. FFT analyzer is used to identify the surface roughness and the data of surface roughness are stored and displayed using an interfaced computer. In results, components affecting surface roughness exist within 200Hz with respect the conditions and methods of grinding operation. Also, with increase of table feed, cross feed and down feed, the value of surface roughness increases. Of them, cross feed has first influence on surface roughness. In dry, preciser surface can be obtained than one in wet.

  • PDF

연삭기용 직각 전자척의 자력특성에 관한 연구 (Magnetic Characteristic of Square Electro-Magnetic Chuck using for Grinding Machine)

  • 맹희영;이용구
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.215-222
    • /
    • 2003
  • The new square electro-magnetic chuck, which is using for the clamping devices on a grinding machine, is developed in this study to improve the convenience of grinding works. The various kinds of structures are recommended to find the most adequate magnetic characteristics through the analytical approach using finite element methods. The analyzed results are retrofitted to solve the drawbacks of previous models step by step by considering the magnetic fields, strength and distribution of drag force, and thermal deformations of chuck. such as high parallelism and flatness. Finally the best recommended models is designed to satisfy the KS specifications required for the commercial magnetic chuck. The prototype chuck with this dimensions and structures is manufactured. For this final model, the experimental verifications are investigated whether the KS specifications are satisfied.

  • PDF

자기베어링으로 지지된 연삭 스핀들의 런아웃 제어 (Runout Control of a Magnetically Suspended Grinding Spindle)

  • 노승국;경진호;박종권;최언돈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1011-1015
    • /
    • 2000
  • In this paper, the case studies of reducing rotational errors is theoretically done for a grinding spindle with an active magnetic bearing system. The rotational errors acting on the magnetic bearing spindle are due to mass unbalance of rotor, runout, grinding excitation and unmodeled nonlinear dynamics of electromagnets. The adaptive feedforward method based on LMS algorithm is discussed to compensate output and input disturbances, and investigated its effectiveness by numerical simulation. The feedforward control reduced external excitation and rotational error for specified frequency. The interpolation method using impulse function for cancelling the electrical 'uncut is studied. These methods show their effectiveness for the rotational accuracy of the improving magnetic bearing spindle through some simulation results of the rotational error decreased by them.

  • PDF

전해 연속 드레싱을 이용한 마이크로 구조물 제작 (A Study on the Micro Structure Fabrication using Electrolytic In-process Dressing)

  • 이현우;최재영;정해도;이석우;최헌종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.258-261
    • /
    • 2002
  • In this study, micro tools(WC) to produce micro-structure and parts, were fabricated ell a cylindrical grinding machine using ELID(Electrolytic In-process Dressing) technique. The shape of the micro-carbide tool was square, corn. The size of the micro-carbide tool was measured less than 10$\mu\textrm{m}$ respectively by SEM(Scanning Electron Microscope). Furthermore, we fabricated micro structure by different processing methods on the desk top cylindrical grinding machine. The manufactured shape was like a tower and the measurement showed that the endpoint of micro structure was $50{\times}50$$\mu{\textrm}{m}$.

  • PDF

연삭기용 직각 전자척의 자력특성에 관한 연구 (Magnetic Charateristics of Square Electro-Magnetic Chuck for Grinding Machine)

  • 맹희영;김성환
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.8-15
    • /
    • 2005
  • The new square electro-magnetic chuck, which can be used for the clamping devices on a grinding machine, is developed in this study to improve the convenience of grinding works. The various kinds of structures are recommended to find the most adequate magnetic characteristics through the analytical approach using finite element methods. The analyzed results are retrofitted to solve the drawbacks of previous models step by step by considering the magnetic fields, strength and distribution of drag force, and thermal deformations of chuck such as high parallelism and flatness. Finally the best recommended models is designed to satisfy the KS specifications required fur the commercial magnetic chuck. The prototype chuck with this dimensions and structures is manufactured. For this final model, the experimental verifications are investigated whether the KS specifications are satisfied.

치과용 바렐연마를 이용한 치과용 합금의 부피와 무게의 변화율 관찰 (Observation of the change rate of volume and weight of dental alloy using dental barrel finishing)

  • 고현정;박유진;최성민
    • 대한치과기공학회지
    • /
    • 제45권2호
    • /
    • pp.48-53
    • /
    • 2023
  • Purpose: This study aimed to provide the basic data for dental barrel finishing by observing the abrasiveness of the metal body according to the time of the barrel finishing. Methods: This study included three types of Co-Cr alloys. The specimens were manufactured by casting method using 10-mm diameter wax spheres (n=10). The cast alloys were polished for 60 minutes at intervals of 5 minutes in barrel finishing. The weight and volume of the specimens were measured, and the rate of change was calculated. The data obtained from the three groups (α=0.05) were compared and analyzed using one-way ANOVA. Results: As a result, the overall volume and weight of the group decreased after grinding compared with the control group. Conclusion: When grinding dental barrel finishing, no difference was observed in the processing rate depending on the type of alloy and the processing rate of the alloy body is within 30 minutes; hence, dental barrel finishing can be effectively used for grinding.

석재가공 공정에서 발생되는 분진과 석영의 입자크기별 농도 특성 (Particle Size-Related Dust and Quartz Concentration of Stone Grinding Operations)

  • 김성환;배혜정;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.462-470
    • /
    • 2014
  • Objectives: The purpose of this study was to evaluate quartz concentrations in airborne respirable dust and particle size-related quartz concentrations. Methods: Respirable dust samples were collected using a 10 mm Dorr-Oliver nylon cyclone equipped with a 37 mm, $5{\mu}m$ pore size PVC filter. Dust samples were collected with a Marple's personal cascade impactor from stone grinding operations in five stone-related business located in the Gyeongsangbuk-do area. Results: The geometric mean of quartz concentration in the respirable dust was $0.170mg/m^3$, and the rate of exceeding the Korean Occupational Exposure Limit(KOEL) was 93.3%. The quartz concentration by particle size shows that it was the highest($0.115mg/m^3$) in stage 5($3.50-6.00{\mu}m$), which corresponds with the size of respirable particle. The smaller the particle sizes were, the higher quartz the content became. The mass fractions of inhalable, thoracic, and respirable dust were 72.1%, 36.0%, and 14.4%. Conclusions: The rate of the quartz concentration in respirable dust from stone grinding operations exceeding the American Conference of Governmental Industrial Hygienists Threshold Limit Values was 100%, which means proper work environmental management is required through regular working environmental measurements. Given that the stone grinding operations had a higher small size dust concentrations, there is a need to reduce respirable dust, such as through wet operation and local exhaust ventilation.

Sleep Disturbances and Personality Type Test

  • Park, Hye Sook
    • Journal of Oral Medicine and Pain
    • /
    • 제40권3호
    • /
    • pp.102-109
    • /
    • 2015
  • Purpose: The purpose of this study was to assess the association between sleep disturbances and personality type. Methods: Five hundred twenty-four college students in Gyeonggi-do completed the Myers-Briggs Type Indicator (MBTI) and a questionnaire and collected data were analyzed by SAS 9.4 program. Results: Extroversion (E) type, sensation (S) type, and perceiving (P) type had significantly higher prevalence of insomnia than introversion (I) type (p<0.05), intuition (N) type (p<0.05), and judging (J) type (p<0.001), respectively. Tooth grinding, snoring and insomnia appeared to occur more frequently in feeling (F) type than in thinking (T) type. Tooth clenching, tooth grinding and snoring seemed to occur more frequently in S type than in N type. Insomnia occurred significantly the most frequently in sensation-feeling (SF) type (p<0.05). Tooth grinding and snoring seemed to occur the most frequently in SF type. A significantly increased percentage of sensation-perceiving (SP) type demonstrated insomnia (p<0.001). Tooth clenching, tooth grinding and snoring seemed to occur the most frequently in sensation-judging (SJ) type. Sensitive or nervous type of personality had significantly higher prevalence of insomnia than relaxed or general type of personality (p<0.01). A significantly increased percentage of subjects with bad general health status showed insomnia (p<0.0001). Tooth clenching and snoring seemed to occur the most frequently in subjects with bad general health status. A significantly decreased percentage of normal weight subjects demonstrated tooth grinding (p<0.05). Snoring occurred significantly the most frequently in overweight subjects (p<0.001). Tooth clenching showed significant correlation with stress (p<0.01) and personality (p<0.05). Snoring showed significant correlation with stress (p<0.05) and body weight (p<0.001). Insomnia showed significant correlation with stress (p<0.0001), personality (p<0.01), and general health status (p<0.0001). Conclusions: Sleep disturbances including tooth clenching and insomnia were associated with personality type and it is desirable to manage them considering personality type.

치과용 자동바렐연마기의 연마시간에 따른 3종 레진의 표면거칠기 관찰 (Observation of surface roughness on three types of resin based on grinding time of dental automatic barrel finishing)

  • 정안나;고현정;박유진
    • 대한치과기공학회지
    • /
    • 제43권2호
    • /
    • pp.56-61
    • /
    • 2021
  • Purpose: This study aimed to produce resin prosthetics using a dental automatic barrel finishing. Surface roughness and surface topography of resins were observed according to the grinding time of the dental automatic barrel finishing. Methods: This study was performed with thermopolymer, autopolymer, and photopolymer resins. The dimensions of the specimen were 10×10×2 mm. Each specimen was polymerized according to the manufacturer's instructions. The polymerized resin was honed for 30 minutes at 5-min intervals in a dental automatic barrel finishing. The specimen was observed using a three-dimensional (3D) optical microscope, and the surface roughness was measured. Results: After the polishing with the dental automatic barrel finishing, the heat-cured (HC) specimen showed the highest and lowest values of Ra after 10 and 15 minutes, respectively. The self-cured (SC) specimen showed the highest and lowest values of Ra after 10 and 25 minutes, respectively. Finally, the 3D specimen showed the highest and lowest values of Ra after 5 and 20 minutes, respectively. Conclusion: After measuring the surface roughness of the three types of resins according to the grinding time of the dental automatic barrel finishing, the lowest Ra values for the HC, SC, and 3D specimens were measured after 15, 25, and 20 minutes, respectively. Therefore, we concluded that a limit on the grinding time of the resin using a dental automatic barrel finishing is needed.