• Title/Summary/Keyword: grid-connected

Search Result 1,226, Processing Time 0.028 seconds

A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter (고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구)

  • Kim, Young-Jin;Hwang, Pyeong-Ik;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2149-2154
    • /
    • 2009
  • Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.

Oxygen Transfer Efficiencies of A Single Spiral Roll Aeration System by the Off-gas Method (Off-gas Analyzer를 이용한 하수처리장 단일선회류 방식 포기시스템 산소전달 효율의 평가)

  • Park, Bo Hwa;Ko, Kwang Baik;Park, Jae Han;Lim, Se Ho;Shin, Dong Rok;Yun, Hye Jung;Lee, Ji Young;Moon, Tae Hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.534-539
    • /
    • 2006
  • The supply of oxygen for aeration is the largest energy consumer at activated sludge wastewater treatment plants. Replacement of less efficient aeration systems with fine pore aeration devices can save up to 50 percent of aeration energy costs. The purpose of this study was the diagnosis and evaluation of a domestic wastewater aeration system by the off-gas method which had been studied by US EPA and ASCE. For this study, an off-gas analyzer and its hood were made to collect off-gas. Also, a vacuum pump was connected to the analyzer to make suction of off-gas. Experiments were conducted at a domestic activated sludge wastewater treatment plant which had a single spiral roll aeration system installed with P.E tube diffuser. Data on OTE(f), SOTE(pw), OUR, and air flow rate were obtained from these experiments. In case of replacing an aeration system, it is recommended that it should be replaced with perforated membrane disc or ceramic disc fine bubble diffusers installed in a full floor coverage or grid pattern.

Composition of efficient monitoring system using an interpolation (보간법을 이용한 효율적인 모니터링 시스템 구성)

  • Lee, Sang-Hyeok;Kang, Feel-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.2
    • /
    • pp.290-298
    • /
    • 2008
  • This paper presents an efficient data storage and reconstruction method in data acquisition and processing of monitoring system. The proposed method extracts minimum data using an interpolation from raw data which are acquired from a target system. They are transferred and saved in a monitoring PC via TCP/IP communication, and then reconstructed as original signals. Therefore, it is possible to design an efficient monitoring system by the improved data communication speed due to the reduced communication packet, and it reduces the storage space. The algorithm for data acquisition and reconstruction is based on Cubic Hermite interpolation. To verify the validity of the proposed scheme, we presents simulation results compared with other interpolation based approaches. Finally, it is applied to a monitoring system for grid-connected photovoltaic power generation system to prove the high-performance of the proposed method.

An Analysis of Urban Open Space with Geographic Information Systems - A Case Study of Ansan City, Korea - (지리정보체계를 이용한 안산시의 오픈스페이스 분석)

  • 서동조;박종화
    • Korean Journal of Remote Sensing
    • /
    • v.6 no.2
    • /
    • pp.89-113
    • /
    • 1990
  • The purpose of this study is to develop means to apply GIS and remote sensing technology to the analysis of Korean urban open spaces. To achieve this objective, a framework of analysis of urban open spaces was developed, and then the framework was applied for the evaluation of the potential and suitability of open spaces of Ansan City, which is a new town developed to accomodate industries relocation from Seoul, Korea, mainly due to their pollution problems. The software used in this study are IDRISI, a grid-based GIS, and KMIPS, a remote sensing analysis system. Both packages are based on IBM PC/AT computers with Microsoft DOS. Landsat MSS and TM data were used for the land use classification, land use change detection, and analysis of transformed vegetation indices. The size of the geographic data base is 110 rows and 150 columns with the spatial resolution of 100m$\times$100m. The framework of analysis includes both quanititative and qualitative analysis of open spaces. The quantitative analysis includes size and distribution of open spaces, urban develpment of open spaces, and the degree of vegree of vegetation removal of the study area. The qualitative analysis includes evaluative criteria for primary productivity of land, park use potential, major visual resources, and urban environmental control. The findings of this study can be summarized as follows. First, the size of builtup areas increased 18.73km$^2$, while the size of forest land decreased 10.86km$^2$ during last ten years. Agricultural lands maintained its size, but shifted toward outside of the city into forest. Second, the potential of open spaces for park use is limited mainly due to their lack of accessibility and connectivity among open spaces, in spite of ample acreage and good site conditions. Third, major landscape elements and historic sites should be connected to the open space system of the city by new accesses and buffers.

Performance Improvement in Single-Phase Electric Spring Control

  • Wang, Qingsong;Zuo, Wujian;Cheng, Ming;Deng, Fujin;Buja, Giuseppe
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.784-793
    • /
    • 2019
  • Two objectives can be pursued simultaneously with the ${\delta}$ control of a single-phase electric spring (ES). These objectives are the stabilization of the voltage across the critical load (CL) of a power system, and the achievement of a specific functionality similar to the pure compensation of reactive power or the correction of the power factor. However, existing control systems implementing the ${\delta}$ control do not cope with non-ideal operating conditions, such as line voltage distortions, and exhibit a somewhat sluggish regulation of the CL voltage. In an effort to improve both the steady-state and transient performances of an ES power system, this paper proposes implementing the ${\delta}$ control by means of a control system built up on the repetitive control and assisted by state feedback with pole assignment. This paper starts by analyzing the dynamics of an ES power system in terms of its poles and zeros. After that, a reduced second-order model of the dynamics is formulated to avoid a notch filter in the pole assignment. A repetitive control for an ES power system is then designed to meet the two above mentioned objectives. Experimental tests carried out on a laboratory setup demonstrate the effectiveness of the proposed control system in significantly improving the ES power system performance, while reaching the two objectives. In particular, the tests outline the large mitigation of harmonics in the CL voltage under line voltage distortions and its fast stabilization action.

A Study on Decision Plan of Hosting Capacity for Distribution Feeder (배전선로 연계용량 선정방안에 관한 연구)

  • Kim, Seong-Man;Oh, Joon-Seok;Kim, Ok-Hee;Lim, Hyeon-Ok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.653-660
    • /
    • 2021
  • Renewable energy resources are rapidly becoming an integral part of electricity generation portfolios around the world due to declining costs, government subsidies, and corporate sustainability goal. Interacting wind, solar, and load forecast errors can create significant unpredictable impacts on the distribution system, feeder congestion, voltage standard and reactive power stability margins. These impacts will be increasing with the increasing penetration levels of variable renewable generation in the power systems. There is a limit to the maximum amount of renewable energy sources that can be connected in a distribution feeder by the connection rule of transmission & distribution facility in Korea. This study represents the decision plans of hosting capacity for distribution feeders without the need for significant upgrades to the existing transmission infrastructure. Especially, the paper suggests and discusses the hosting capacity standard of feeder cables and minimum load calculation of distribution feeders.

Design of Simulated Photovoltaic Power Streetlight for Education using Renewable Energy Utilization and Storage Function (신재생에너지 활용 및 저장기능을 이용한 교육용 모의 태양광발전 가로등 설계)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.2
    • /
    • pp.137-142
    • /
    • 2021
  • A Photovoltaic power streetlight is a system that uses solar energy to charge a secondary battery and then uses it for night lighting through a lamp, and can be configured as a standalone or grid-connected type by installing an LED streetlight at the load end. The energy generated through the solar cell module can be charged to the secondary battery through the charge/discharge control device, and then the LED street light can be turned on and off by comparing the power generation voltage and the charging voltage according to the monitoring of solar radiation, or by setting a specific time after sunset or sunrise. Based on these contents, this paper designed and manufactured a simulated solar power streetlight for education using new and renewable energy utilization and storage functions. Using these educational equipment, students can 1) understand the flow of energy change using renewable energy including sunlight as electric energy, 2) understand new and renewable energy, and cultivate basic design and manufacturing application power of related products, 3) The use of new and renewable energy through power conversion and strengthening of practical training and analysis through hardware production can be instilled.

A Study on the Change of Spatial Structures of Shared Space at Urban Campuses - The opposite concept of Gridlock upon the change to shared campuses - (도심 캠퍼스 공유공간의 공간 구조 변화에 대한 연구 - 그리드락의 반대 개념으로서의 공유 캠퍼스로의 변화에 대하여 -)

  • Kang, Eunki;Baek, Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.145-156
    • /
    • 2018
  • Urban campus, one of the main urban facilities, is the representative place that is struggling with 'gridlock'. Due to privatization of space among different departments and space shortages, gridlock has been occurring as a result. The urban campus trying to solve this problem by changing the quality of space, especially the structure of the shared space, which is expected to be the solution to the grid lock problem. The main purpose of this study is to investigate the structural change in the university's shared space based on paradigm transition. The theoretical consideration is to analyze the spatial characteristics of university shared space that appear at different stages through a new perspective that compares the gridlock phenomenon and the shared paradigm. The framework of the analysis of the shared space, which has recently been restructured, is classified into the spatial characteristics of collaborative space, the creative space, and the common/complex space. In addition, these spatial characteristics are again analyzed through the division of legislative facility classification, management governance subject, area, building location and layout, exposure to the outside as well as the analysis of student and staff entry and exit, sharing structure of site and space, and the classification of program characteristics. The results are as follows: The restructured space is systemized so that the management governance of each space would be connected to each other to share information and space. Furthermore, the spatial boundary between colleges or between campus spaces are not only physically, but categorically clear. The restructured space has semi (or in-between)-spatial characteristics such as the intersection in inside and outside of the pedestrian's circulation and the mixture of programs. This study could serve as principal references in presenting the systematic analysis of directions of the shared spatial structure for the urban campus where new educational space is required due to the changes in the university system.

A Study on Characteristic of Hybrid PCS for Solar Power Generation Considering on a Residential Lithium Battery ESS. (가정용 리튬배터리 ESS를 고려한 태양광 발전 하이브리드 PCS 특성에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Choi, Byung-Sang
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.1
    • /
    • pp.35-45
    • /
    • 2022
  • In this paper, we modeled the devices used easily in PV system circuits. In addition, for full operation of the photovoltaic system, a complete operation system for the DC-DC buck-boost converter and the MPPT control system was modeled and simulated to confirm good operation. we were constructed an actual system with the same conditions in the simulation and experimented. The purpose is to confirm the stable power supply through the load leveling by presenting the PCS considering ESS of photovoltaic power generation. we will do study to apply hybrid capacitors that have high energy density to the same size compared to the EDLC to DVR. As a result, we proposed a single-phase 3 kW grid-connected solar power converter.

Performance Improvement Method of Convolutional Neural Network Using Combined Parametric Activation Functions (결합된 파라메트릭 활성함수를 이용한 합성곱 신경망의 성능 향상)

  • Ko, Young Min;Li, Peng Hang;Ko, Sun Woo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.9
    • /
    • pp.371-380
    • /
    • 2022
  • Convolutional neural networks are widely used to manipulate data arranged in a grid, such as images. A general convolutional neural network consists of a convolutional layers and a fully connected layers, and each layer contains a nonlinear activation functions. This paper proposes a combined parametric activation function to improve the performance of convolutional neural networks. The combined parametric activation function is created by adding the parametric activation functions to which parameters that convert the scale and location of the activation function are applied. Various nonlinear intervals can be created according to parameters that convert multiple scales and locations, and parameters can be learned in the direction of minimizing the loss function calculated by the given input data. As a result of testing the performance of the convolutional neural network using the combined parametric activation function on the MNIST, Fashion MNIST, CIFAR10 and CIFAR100 classification problems, it was confirmed that it had better performance than other activation functions.