Constructing a Reservation Table for Automated Guided Vehicles in Port Container Terminal (컨테이너 터미널에서의 AGV의 교착방지를 위한 주행영역 예약 표 작성방법)

  • Jeon, Su-Min;Kim, Kap-Hwan
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.3
    • /
    • pp.85-94
    • /
    • 2008
  • Automated Guided Vehicles (AGVs) are important equipment in automated container terminals. To utilize AGVs for transporting containers from a position to another, the deadlock is a serious problem that must be solved before they are deployed to real operations. This study assumes that traveling area for AGVs are divided into a large number of grid-blocks and, as a method of traffic control, grid-blocks are reserved in advance during the travel of AGVs. The purposes of the reservation are to make the room between AGVs and to prevent deadlocks. Because the size of an AGV is much larger than the size of a grid-block on guide paths, this study assumes an AGV may occupy more than one grid-block at the same time. This study suggests a method for constructing a table of reservation schedules by using a simulation. A sensitivity analysis was conducted to evaluate the performance of the reservation method in this study.

  • PDF

Techno-Economic Optimization of a Grid-Connected Hybrid Energy System Considering Voltage Fluctuation

  • Saib, Samia;Gherbi, Ahmed;Kaabeche, Abdelhamid;Bayindir, Ramazan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.659-668
    • /
    • 2018
  • This paper proposes an optimization approach of a grid-connected photovoltaic and wind hybrid energy system including energy storage considering voltage fluctuation in the electricity grid. A techno-economic analysis is carried out in order to minimize the size of hybrid system by considering the benefit-cost. Lithium-ion battery type is used for both managing the electricity selling to the grid and reducing voltage fluctuation. A new technique is developed to limit the voltage perturbation caused by the solar irradiance and the wind speed through determining the state-of-charge of battery for every hour of a day. Improved particle swarm optimization (PSO) methods, referred to as FC-VACPSO which combines Fast Convergence Particle Swarm Optimization (FCPSO) method and Variable Acceleration Coefficient Based Particle Swarm Optimization (VACPSO) method are used to solve the optimization problem. A comparative study has been performed between standard PSO method and PSO based methods to extract the best size with the benefit cost. A sensitivity analysis has been studied for different kinds and costs of batteries, by considering variable and constant state-ofcharge of battery. The simulations, performed under Matlab environment, yield good results using the FC-VACPSO method regarding the convergence and the benefit cost of the hybrid system.

Automatic Classification of Drone Images Using Deep Learning and SVM with Multiple Grid Sizes

  • Kim, Sun Woong;Kang, Min Soo;Song, Junyoung;Park, Wan Yong;Eo, Yang Dam;Pyeon, Mu Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.5
    • /
    • pp.407-414
    • /
    • 2020
  • SVM (Support vector machine) analysis was performed after applying a deep learning technique based on an Inception-based model (GoogLeNet). The accuracy of automatic image classification was analyzed using an SVM with multiple virtual grid sizes. Six classes were selected from a standard land cover map. Cars were added as a separate item to increase the classification accuracy of roads. The virtual grid size was 2-5 m for natural areas, 5-10 m for traffic areas, and 10-15 m for building areas, based on the size of items and the resolution of input images. The results demonstrate that automatic classification accuracy can be increased by adopting an integrated approach that utilizes weighted virtual grid sizes for different classes.

Sizing and Economic Analysis of Battery Energy Storage System for Peak Shaving of High-Speed Railway Substations (고속철도 변전소 피크부하 저감용 ESS 용량 산정 및 경제성 분석)

  • Kim, Seul-Ki;Kim, Jong-Yul;Cho, Kyeong-Hee;Byun, Gil-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • The paper proposed a sizing method of an energy storage system(ESS) for peak shaving of high-speed railway substations based on load profile patterns of substations. A lithium based battery ESS was selected since it can produce high-power at high speed that peak shaving requires, and also takes up a relatively smaller space for installation. Adequate size of the ESS, minimum capacity which can technically meet a peak shaving target, was determined by collectively considering load patterns of a target substation, characteristics of the ESS to be installed, and optimal scheduling of the ESS. In case study, a local substation was considered to demonstrate the proposed sizing method. Also economic analysis with the determined size of ESS was performed to calculate electricity cost savings of the peak shaving ESS, and to offer pay-back period and return on investment.

Quantification of Uncertainty Associated with Environmental Site Assessments and Its Reduction Approaches (부지 오염도 평가시 불확실성 정량화 및 저감방안)

  • Kim, Geonha;Back, JongHwan;Song, Yong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.1
    • /
    • pp.26-33
    • /
    • 2014
  • Uncertainty associated with a sampling method is very high in evaluating the degree of site contamination; therefore, such uncertainty affects the reliability of precise investigation and remediation verification. In particular, in evaluating a site for a small-sized filling station, underground utilities, such as connection pipes and oil storage tanks, make grid-unit sampling impossible and the resulting increase in uncertainty is inevitable. Accordingly, this study quantified the uncertainty related to the evaluation of the degree of contamination by total petroleum hydrocarbon and by benzene, toluene, ethylene, and xylene. When planning a grid aimed at detecting a hot spot, major factors that influence the increase in uncertainty include grid interval and the size and shape of the hot spot. The current guideline for soil sampling prescribes that the grid interval increase in proportion to the area of the evaluated site, but this heightens the possibility that a hot spot will not be detected. In evaluating a site, therefore, it is crucial to estimate the size and shape of the hot spot in advance and to establish a sampling plan considering a diversity of scenarios.

A Study on the Effect of Grid Size to Extract Topographical Parameters by DEM (DEM에 의한 지형인자 추출에 따른 격자크기의 영향에 관한 연구)

  • Jeong, In-Ju;Lee, Jung-Min;Kim, Sang-Yong;Lee, Jong-Chool
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.2 s.20
    • /
    • pp.67-75
    • /
    • 2002
  • Recently, GIS tend to be studied in water resoruces field. In hydrology analysis, GIS propose way that can develop subjective element of designer objectively. The development project is conducting disaster effect estimation to breed disaster, and cope these disaster beforehand provoking soil erosion and food recently. In this study, receive value of LS factor through DEM data at volume of soil erosion computation by disaster effect estimation and whether it are some relation effect of gradient and change of soil erosion by grid size did comparative analysis. As a result, according as grid size great, gradient became slow and could know that error value of gradient great according as storing scale of digital topographical map grows.

  • PDF

A strengthening effect based on a grid size of a bamboo-mat and a model-test for the understanding on ground failure. (대나무매트의 격자크기에 따른 보강효과 및 지반 파괴형상 파악을 위한 모형시험)

  • Lee, Ji-Hun;Kim, Seung-Gon;Kim, Woo-Jin;Kim, Jong-Ryeol;Kang, Hee-Bog
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1673-1677
    • /
    • 2008
  • A method of construction with a basis treatment that uses a latticed bamboo mat puts bamboo's peculiarity and bamboo mat's bending substance to use, and a latticed bamboo mat equally distributes to embankment loading in a basis ground. Therefore it prevents ground destruction by an ill-balanced load and an irregular ground subsidence, and it makes safety system. This investigation make progress a soil box model by a dredged reclamation ground of west and south sea at domestic area, and make a comparative study and analyze the strengthening effect based on a grid size of a bamboo-mat and ground failure that it will use in the field.

  • PDF

Welding Quality Evaluation on the LASER Welding Parts of the Spacer Grid Assembly for PWR fuel Assembly (경수로 원전연료용 지지격자의 LASER 용접품질 평가)

  • Song, Gi-Nam;Yun, Jeong-Ho;Gang, Hong-Seok;Lee, Gang-Hui;Kim, U-Gon;Kim, Su-Seong
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.109-111
    • /
    • 2005
  • Nuclear fuel assemblies for pressurized water reactors(PWR) are loaded in the reactor core throughout the residence time of three to five years. A spacer grid assembly, which is an interconnected array of slotted grid straps and is welded at the intersections to form an egg crate structure, is one of the main structural components of the nuclear fuel assembly. The spacer grid assembly is structurally required to have enough buckling strength under various kinds of lateral loads acting on the nuclear fuel assembly so as to keep the nuclear fuel assembly straight. To meet this requirement, it is necessary to weld the welding parts carefully and precisely. In this study, laser welding qualities of the spacer grid assembly welded by several welding companies, such as weld strength, weld penetration depth, and weld bead size, are examined and compared.

  • PDF

Improved Control Strategy Based on Space Vectors for Suppressing Grid-Side Current Harmonics in Three-Phase Current Source Rectifiers with a Hybrid Switch

  • Xu, Yan;Lu, Guang-Xiang;Jiang, Li-Jie;Yi, Gui-Ping
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.497-503
    • /
    • 2015
  • This paper analyses the harmonic pollution to power grids caused by several high-power rectifiers, summarizes the requirements for rectifiers in suppressing grid-side current harmonics and optimizes a new-type of current source PWM rectifier with a hybrid switch. The rectifier with a hybrid switch boasts significant current characteristics and cost advantages in the high-power area. To further enhance the working frequency of the current source rectifier with a hybrid switch for suppressing grid-side harmonics and reducing the inductance size, this paper proposes an optimal control strategy based on space vector. It also verifies that the optimal control strategy based on space vector can reduce the total harmonic distortion of the grid-side current of the rectifier with a hybrid switch via circuit simulation and experimental results.

Dynamic Resource Ranking and Grouping Algorithm for Grid Computing (그리드 컴퓨팅을 위한 동적 자원 랭킹 및 그룹핑 알고리즘)

  • Yi Jinsung;Park Kiejin;Choi Changyeol;Kim Sungsoo
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.4
    • /
    • pp.471-482
    • /
    • 2005
  • The high-speed network permits Grid computing to handle large problem of management areas and share various computational resources. As there are many resources and changes of them in Grid computing, the resources should be detected effectively and matched correctly with tasks to provide high performance. In this paper, we propose a mechanism that maximizes the performance of Grid computing systems. According to a priority, grade and site of heterogeneous resources, we assign tasks to those resources. Initially, a volunteer's priority and ranking are determined by static information like as CPU speed, RAM size, storage size and network bandwidth. And then, the rank of resources is decided by considering dynamic information such as correctness, response time, and error rate. We find that overall Grid system performance is improved and high correctness using resource reallocation mechanism is achieved.