• Title/Summary/Keyword: greensand

Search Result 1, Processing Time 0.017 seconds

Manganese Removal in Water Treatment Processes (상수처리에서 망간 제거)

  • Kim, Jinkeun;Jeong, Sanggi;Kim, Jeongsook;Park, Sejin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.595-604
    • /
    • 2005
  • To determine the characteristics of manganese removal in Korea, 31 multi-regional water treatment plants (WTPs) were examined. The concentration of manganese in raw water was higher than the standards for drinking water at 2 WTPs. Manganese should be properly removed during water treatment processes to reduce the occurrence of black water in the distribution system because $Mn^{+2}$ can cause black deposits when it is oxidized. Manganese can effectively removed by oxidation, followed by sedimentation and filtration as well as absorption by greensand. Manganese absorption by greensand was the major mechanism for the removal of manganese, and it is effectively removed using this process. Regeneration of greensand using an oxidation agent was necessary for continuous and adequate removal of manganese.