• Title/Summary/Keyword: greenhouse type

Search Result 511, Processing Time 0.031 seconds

Development of Semi-basement Type Greenhouse Model for Energy Saving

  • Kim, Seoung Hee;Joen, Jong Gil;Kwon, Jin Kyeong;Kim, Hyung Kweon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.328-336
    • /
    • 2016
  • Purpose: The heat culture areas of greenhouses have been continuously increasing. In the face of international oil price fluctuations, development of energy saving technologies is becoming essential. To save energy, auxiliary heat source and thermal insulation technologies are being developed, but they lack cost-efficiency. The present study was conducted to save energy by developing a conceptually new semi-basement type greenhouse. Methods: A semi-basement type greenhouse, was designed and constructed in the form of a three quarter greenhouse as a basic structure, which is an advantageous structure to inflow sunlight. To evaluate the performance of the developed greenhouse, a similar structured general greenhouse was installed as a control plot, and heating tests were conducted under the same crop growth conditions. Results: Although shadows appeared during the winter in the semi-basement type greenhouse due to the underground drop, the results of crop growth tests indicated that there were no differences in crop growth and development between the semi-basement type greenhouse and the control greenhouse, indicating that the shadows did not affect the crop up to the height of the crop growing point. The amount of fuel used for heating from January to March was almost the same between the two greenhouses for tests. The heating load coefficients of the experimental greenhouses were calculated as $3.1kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the semi-basement type greenhouse and $2.9kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the control greenhouse. Since the value is lower than the double layer PE (polyethylene) film greenhouse value of $3.5kcal/m^2{\cdot}^{\circ}C{\cdot}h$ from a previous study, Tthe semi-basement type greenhouse seemed to have energy saving effects. Conclusions: The semi-basement type greenhouse could be operated with the same fuel consumption as general greenhouses, even though its underground portion resulted in a larger volume, indicating positive effects on energy saving and space utilization. It was identified that the heat losses could be reduced by installing a thermal curtain of multi-layered materials for heat insulation inside the greenhouse for the cultivation of horticultural products by installing thermal curtain of multi-layered materials for heat insulation inside the greenhouse, it was identified that the heat losses could be reduced.

A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation (박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Cheong, Jae-Woan;Choi, Gyeong Lee
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

Current Status of Lighting System and Illumination Distribution in the Greenhouse for Light Culture of Strawberries (딸기 전조재배 온실의 인공광 설치실태 및 조도분포 조사분석)

  • 김태한;장익주;이경진
    • Journal of Biosystems Engineering
    • /
    • v.24 no.1
    • /
    • pp.19-24
    • /
    • 1999
  • Motivated by the need for developing the more efficient lighting system for light culture of strawberries in the greenhouse, this paper aims at acquiring and suggesting more concrete and scientific foundation of illuminating position, numbers of light source by investigating the types of lighting system and illumination distribution in the greenhouse for light culture of strawberries. The results of investigation and experiment are summarized as following below: 1. The types of lighting system used in the greenhouse producing strawberries were classified as 1 line and 2 lines lighting system. 2. As for the arranging types of artificial light, 2 lines lighting system, were classified as Z-type, N-type and W-type. (Refer Fig. 3) 3. The results of illumination distribution for Z-type, N-type and W-type of 2 lines illuminating system in the greenhouse with a small size tunnel measured at the height of 1.5m from the ground with 220V, 100W lamp in 6m light gap showed that maximum illuminance are 961x, 1211x, 1251x, minimum illuminance are 4.41x, 4.71x, average illuminance are 33.71x, 43.11x, 44.51x and standard deviations are 28.31x, 35.41x, 38.31x at each types. 4. Proportion of the area below optimal illuminance to floor area at the two lines illuminating system of Z-, N-, and W-type in greenhouse were appeared as 39.4%, 26.0% and 26.3%, respectively. Also proportion of the area over optimal illuminance to floor area at the two lines illuminating system of Z-, N-, W-type in greenhouse were appeared as 16.8%, 14% and 14.7%, respectively. Thus N-type was superior to the others from the view points of optimal illumination distribution and energy saving.

  • PDF

Greenhouse environment analysis -Distributions and Variations of Temperature , Relative humidity Illumination , Carbon dioxide and Wind Velocity-

  • Kim, Y.B;Park, J.C.;Song, H.K.;Paek, Y.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.478-486
    • /
    • 1993
  • For satisfactory greenhouse culture, environmental factors must be kept in proper conditions. Therefore, it is important to know relations between environmental conditions and greenhouse systems. In this study, the environment variations and distributions in different types of greenhouses were measured and analyzed. The elements of environment analyzed were temperature , relative humidity, illumination, carbon dioxide and wind velocity. The analyzed greenhouse types were three different types. One of them, A type, was propagation model type by government and the other one, B type, was multiple continuous arches type which was made by farmers himself. The last one, C type, was single arch type which has no environment control system without manual temperature keeping method. The results of this study can be used for reasonable greenhouse environments managements and control.

  • PDF

Modelling Development and Environmental Analysis of Oriental Melon Greenhouse in SUNGJU(1) -Characteristics on distribution of air temperature for cultivating oriental melon in tunnel type greenhouse in Sungiu- (성주지역 참외전용 온실의 모델개발 및 환경분석(1) -성주 시설 참외단지 단동하우스의 온도 분포 특성-)

  • 송재관;박규식;구건효
    • Journal of Bio-Environment Control
    • /
    • v.7 no.4
    • /
    • pp.311-323
    • /
    • 1998
  • This study was conducted to analyze the temperature characteristics under tunnel type greenhouse to cultivate watermelon in Sungju region. Air temperature of tunnel type greenhouse was descending rapidly after sunset, and the time required the air temperature inside greenhouse nearly reached the outside air temperature was about 2.5 hours. The maximum air temperature in tunnel type greenhouse, in case of high air temperature day, was exceeding 4$0^{\circ}C$ during day time. Air temperature inside greenhouse during night time could sustain about 2~3$^{\circ}C$ higher than the outside air temperature. But it was necessary to supply supplemental heat when the air temperature was below optimum growth temperature. Soil temperature in the depth of 20cm under soil surface could maintain higher than 2$0^{\circ}C$ and the variation range in a day was 3~5$^{\circ}C$, and the soil temperature descending due to irrigation was about 5~6$^{\circ}C$.

  • PDF

Characteristics of PPF Transmittance and Heat Flow by Double Covering Methods of Plastic Film in Tomato Greenhouse (토마토재배용 플라스틱온실의 이중피복방법에 따른 광합성유효광량자속 투과 및 열관류 특성)

  • Lee, H.W.;Sim, S.Y.;Kim, Y.S.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.11-18
    • /
    • 2010
  • This study was conducted to provide design data for deciding covering method in double layers greenhouse. The variation of photosynthetic photon flux (PPF) and heat flow in air inflated and conventional double layers greenhouse was analyzed. The PPF of air inflated double covering greenhouse was less than that of conventional greenhouse during summer season because the more PPF comes into conventional greenhouse through roof vent which was rolled up for ventilation. The air inflated double layers covering greenhouse was superior to conventional type in the aspect of controlling inside temperature down owing to lower irradiation. The PPF of air inflated greenhouse was greater than that of conventional greenhouse during winter season because the transmittance of conventional greenhouse decreased by dust collected on inside plastic film nearly closed for insulation. Considering the PPF not sufficient for tomato growing in winter, the air inflated double covering system with the greater transmittance was better than conventional covering system. When the inside air of air inflated greenhouse was injected into space between the double layers of covering, the PPF of air inflated greenhouse was much less than the conventional greenhouse because the transmittance of air inflated double covering decreased due to condensation of highly humidified inside air. It was concluded that the more dried outside air should be used for inflating double layers covering. The heat insulation performance of air inflated double covering system was superior to conventional double covering system when comparing the overall heat transfer coefficients for each covering method. However the differences among the overall heat transfer coefficients depending on difference between inside and outside temperatures of greenhouse were great, it is necessary to conduct additional experiment for investigating the overall heat transfer coefficient to design the double layers covering.

Prediction of Greenhouse Energy Loads using Building Energy Simulation (BES) (BES 프로그램을 이용한 국내 대표적 대형온실의 에너지 부하 예측)

  • Lee, Sung-Bok;Lee, In-Bok;Homg, Se-Woon;Seo, Il-Hwan;Bitog, P. Jessie;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Han, Chang-Pyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.113-124
    • /
    • 2012
  • Reliable estimation of energy load inside the greenhouse and the selection of cooling and heating facilities are very important preceding factors to save energy as well as initial and maintenance costs of operating a greenhouse. Recently, building energy simulation (BES) technique to simulate a model similar to the actual conditions through a variety of dynamic simulation methods, and predict and analyze the flow of energy is being actively introduced and developed. As a fundamental research to apply the BES technique which is mainly used for analysis of general buildings, to greenhouse, this research designed four types of naturally-ventilated greenhouses using one of commercial programs, TRNSYS, and then compared and analyzed their energy load properties, by applying meteorological data collected from six regions in Korea. When comparing the greenhouse load of each region depending on latitude and topographical characteristics through simulation, Chuncheon had nearly 9~49 % higher heating load per year than other regions, but its annual cooling load was the reverse to it. Except for Jeju, 1-2W type greenhouses in five regions showed about 17 % higher heating load than a widespan type greenhouse, and 1-2W type greenhouses in Chuncheon, Suwon, Cheongju, Daegu, Cheonju and Jeju had 23 %, 20 %, 17 %, 16 %, 18 % and 20 % higher cooling load respectively than a wide span-type one. Glasshouse and vinyl greenhouse showed 8~11 % and 10~12 % differences respectively in heating load, while 2~10 % and 7~10 % differences in cooling load respectively.

A Study on the Shape of Section in Member and Stress Tolerant Structural System in the Frame of Green Houses (내재해성이 우수한 비닐하우스 부재의 단면형상 및 구조시스템에 관한 연구)

  • Shim, Jong-Seok;Han, Duck-Jeon
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.4
    • /
    • pp.67-75
    • /
    • 2012
  • The damage of greenhouse has been increasing due to frequent collapse of frame in greenhouse caused by the heavy snow and strong wind. But, greenhouses are constructed by steel tube members of pipe style and pin connection of them, so these greenhouses are very weak. Therefore, this study was carried out to find the type of member section and structural frame system in stress tolerant greenhouses. The modeling types for analysis were designed in accordance with structural frame configuration and member section in greenhouse. These types of models, which are existing type, diagrid type, symmetric and asymmetric section type of frame member in greenhouse were classified. Displacement analysis varying the vertical and horizontal loads for a series of models was carried out. As a result of this paper, it was verified that the structural frame configuration of diagrid type and asymmetric type of member section is better than existing type in the frame of greenhouses against snow loads and wind loads.

Development of Design Technology of Korean Style Air-Inflated Double-Layer Plastic Greenhouse (한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Nam, Hyo-Seok;Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.185-191
    • /
    • 2009
  • The construction of experimental greenhouses, operating test, and analysis on variation of different environment factors were conducted to provide fundamental data for design of Korean style air-inflated double-layer plastic greenhouse. The development of technology of attaching plastic to the structure and fasteners to be able to keep airtight was required in order to maintain proper static pressure in air space of double layer coverings. The insulation effect of air inflated greenhouse was better than conventional type. The temperature of arch type roof was greater about $2^{\circ}C$ than peach type roof in air inflated greenhouse. It was recommended that the plastic should be attached at the edges without clearance length in order to ease installation and raise airtightness of double layer coverings. The transmittance of arch type roof was greater than peach type in air inflated one span greenhouse. The transmittance of air inflated greenhouse was greater than conventional type due to frame ratio and distance between double layers in three span greenhouse. The condensation occurred on conventional type greenhouse was more than air inflated type. It was required to examine for a long time in order to analyze it quantitatively.

The Comparative Analysis of Drying-Conditions, -Rates, -Defects and Yield, and Heat-Efficiency in Solar-Dehumidification-Drying of Oaks With Those in Conventional Air-, Semi-Greenhouse Type solar-, and Kiln- Drying (참나무류(類)의 제습태양열건조(除濕太陽熱乾燥)의 조건(條件), 속도(速度), 결함(缺陷), 수율(收率) 및 열효율(熱效率)과 관행(慣行) 천연(天然), 반온실형(半溫室型) 태양열(太陽熱) 및 열기건조(熱氣乾燥)와의 비교(比較)·분석(分析))

  • Lee, Hyoung-Woo;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.22-54
    • /
    • 1989
  • Seasonal semi-greenhouse type solar-drying of 2.5cm-and 5.0cm-thick lumber of Quercus aliena Blume and Quercus variailis Blume was carried out to investigate the possibility of solar-drying of wood and to decide the active solar-drying period in Korea. In the active solar-drying period obtained solar-dehumidification, semi-greenhouse type solar-, air- and kiln-drying of 2.5cm -thick lumber of oaks were carried out to analyze drying-rates. -defects, and -yield in each drying-method and to calculate daily total absorbed solar-radiation the solar dryers. The energy balance equations were set up, considering all the energy requirements, to analyze the heat efficiencies of semi-greenhouse type solar and solar-dehumidification-dryer. In a seasonal drying the drying rate of semi-greenhouse type solar-dryer was highest in summer, and greater in fall, spring, and winter in order. Solar-drying time was 45% in summer to 50% in winter of the air-drying rime, and more serious drying-defects occurred in air-drying than in solar-drying. In the active solar-drying period. April, May, and June, the average drying rate in solar-dehumidification-drying was 1.0%/day and greater than 0.8%/day in semi-greenhouse type solar-drying. In solar-dehumidification-drying the time required to dry lumber to 10% moisture content was less than 60 days, and solar-dehumidification-drying showed the highest drying-yield, 65.01%, than the other drying methods. The daily total absorbed solar radiations were 8.51MJ on the roof collector and 6.22 MJ on the south wall collector. In the energy blance 69.48% of total energy input was lost by heat conduction through walls, roof. and floor 11.68% by heat leakage, 0.33% by heating the internal structures of the solar-dryer and 5.38% by air-venting. Therefore the heat efficiency of semi-greenhouse type solar-dryer 13.13%, was lower than that of solar-dehumidification-dryer, 14.04%. Solar-drying of lumber in Korea showed the possibility to reduce the air-drying-time in every season and the efficiency of solar-dehumidification drying was higher than that of semi-greenhouse type solar-drying.

  • PDF