본 연구에서는 자동차엔진의 신품제조시와 재제조시 발생하는 환경영향을 전과정 관점에서 산정하고 이를 기반으로 온실가스 저감효과를 산정하였다. 자동차엔진 원부자재 원료취득 및 제조공정에서 배출되는 온실가스량은 신품제조시 약 3,473 kg, 재제조시 약 872 kg으로 재제조를 통해 저감되는 온실가스량은 약 2,601kg으로 나타나 폐기 단계를 제외한 전과정 측면에서 저감효과가 있는 것으로 분석되었다. LCA 가중화 분석 결과 신품 제조시 환경영향은 1.07E+03 Eco-point, 재제조시 2.67E+02 Eco-point로 나타났으며, 주요 6대 영향 범주 중 지구온난화 점유비율이 99.72%, 99.68%로 높게 나타났다.
The purpose of this paper is to come up with the measures for sustainable development of the agricultural sector in store for the strengthened U.N. Framework Convention on Climate Change. We analyze the spillover effects of Methane and Nitrous Oxides taxes (carbon tax) on the Korean agricultural sector. Unlike the other sectors, the agricultural sector has a unique characteristic generating greenhouse gas in the process of production itself even without consuming much fossil fuel. In order to estimate the impacts of those taxes, non-linear optimization method has been used with various assumed scenarios. The production effect, income and' price effect, and greenhouse gas emission reduction effect in the agricultural sector have been estimated through this method. The empirical results show that the paddy sector has a bigger tax effect than the livestock sector. In the paddy sector, the carbon tax has more impacts in the suburban areas than in the rural areas, while the swine farming section in the livestock sector has a conspicuous income effect in the midst of low greenhouse gas emission effect. These results allude us to apply graded tax rates to the crop, the livestock, and the region of different kind. Even if the agricultural sector has a less tax effect when compared with other industrial sectors, an environmental tax might be an effective measure to prevent global warming.
온실의 냉난방부하 산정을 위해 설계자가 선택해야할 주요 변수들에 대하여, 이들 설계 변수가 냉난방부하에 미치는 영향을 평가하기 위해서 각각의 설계 변수값을 변화시키면서 시뮬레이션을 실시하였으며, 이를 바탕으로 특별히 선택에 주의를 기울여야 할 설계 변수를 제안하였다. 난방부하에 가장 큰 영향을 미치는 설계 변수는 피복재의 열관류율이고, 다음으로 설계외기온인 것으로 나타났다. 연동수에 따른 설계 변수의 영향은 차이가 거의 없는 것으로 나타났다. 단동 온실의 경우에는 지중전열 관련 설계 변수의 영향을 무시할 수 없을 것으로 생각되지만, 연동 온실의 경우에는 지중전열 관련 변수 및 틈새환기율의 영향이 미미한 것으로 판단되었다. 냉방부하에 가장 큰 영향을 미치는 설계 변수는 온실내로 유입되는 일사량과 증발산계수이고, 다음으로 실내외 기온차, 환기율인 것으로 나타났다. 설계 변수의 영향은 단동 온실과 연동 온실에서 큰 차이를 보였으나, 연동수에 따른 차이는 거의 없는 것으로 나타났다. 피복재의 열관류율은 단동 온실이나 연동 온실 모두 영향이 미미한 것으로 나타났지만, 실내외 기온차 및 환기율의 경우에는 냉방부하에 미치는 영향을 무시할 수 없을 것으로 생각되며, 특히 연동 온실에서 그 영향이 더 큰 것으로 판단되었다. 냉방부하를 산정할 때 실내 목표온도를 낮게 설정할수록 설계 변수의 선택에 신중해야 한다. 특히, 실내 목표온도를 외기온 보다 낮게 설정하면 환기율 및 열관류율 값이 냉방부하를 증가시키는 방향으로 바뀌므로 더욱 주의해야 한다. 환기율이 낮을 때는 설계 변수 중 설계일사량과 증발산계수의 선택에 주의해야 하고, 환기율이 높을 때는 실내 설정온도와 설계외기온의 선택에 신중을 기해야 한다.
본 연구는 중학생들이 온실 효과와 지구 온난화를 이해하고, 이를 지구 복사 평형 관점에서 설명할 수 있는지 심층적으로 살펴보고자 하였다. 이를 위해 '대기권과 날씨' 대단원 수업을 완료한 중학교 3학년 118명의 학생을 대상으로, 복사 평형, 온실 효과, 지구 온난화에 대한 선택형 및 서답형으로 구성된 학생 이해 온라인 평가를 2021년 7월 13일부터 7월 24일까지 실시하였다. 최종적으로 97명의 학생 응답을 수집하여 분석한 결과, 과반수(61.9%)가 넘는 학생들이 복사 평형의 의미를 옳게 기술하였으나 제시된 자료와 무관하게 사전 지식이나 구체적 사례를 들어 설명하는 경우가 많았다. 대부분의 학생들(92.8%)은 대기가 있는 지구에서 온실 효과가 나타나는 것을 알고 있었지만, 온실 효과를 복사 평형이 깨진 상태로 생각하는 경향이 높았으며(32.0%), 달과 지구 모두 복사 평형이 일어난다고 응답한 학생(47.4%)은 절반에 미치지 못했다. 온실 효과의 원인으로 대기의 재복사를 찾아낸 학생은 다수(69.1%)였으나, 지구로 입사한 태양 복사량보다 방출한 지표 복사량이 더 크다고 응답한 학생은 소수(39.2%)에 불과하였다. 또한 절반 정도의 학생들(49.5%)이 온실 기체의 증가와 대기 흡수, 이로 인한 지표로의 재복사의 관계를 잘 이해하고 있었다. 그러나 온실 기체가 증가할 때, 지표 방출에 대해서는 증가(14.4%), 일정(9.3%), 감소(7.2%), 무응답(18.6%)으로 의견이 매우 다양하게 나타났다. 복사 평형, 온실 효과, 지구 온난화는 지구계의 균형과 상호작용이라는 빅 아이디어로 연결된 커다란 하나의 의미망이므로 학생들이 지구 온난화로 인한 기후 변화를 이해하고 적용하고 해석하는 개념 체계가 될 수 있다. 따라서 현재 인류에 닥친 기후 변화 위기와 관련해 학생들이 정확한 이해에 근거하여 과학적으로 사고하고 과학적 개념을 정립할 수 있도록, 정교한 프로그램 개발과 수업 경험을 제공하고 그 효과를 점검하는 후속 연구가 진행 되어야 할 것이다.
As the number of plastic greenhouses has increased in Korea, the damage from typhoons and snow has also increased. Structural design codes for a disaster-resistant plastic greenhouse have been revised over the last few decades. In particular, the revised code draft in 2017 have changed in many ways compared to the 1995 code. Nevertheless, There is no study of the effect of new design code on plastic greenhouse. Therefore, this study evaluated the safety of plastic greenhouse against wind load according to 1995 and 2017 codes for type 1 houses, which is most commonly built in Jeju, through comparing the analytical results of plastic greenhouses designed by 1995 code and 2017 code draft. The results are as follows. (1) The uplift load due to the negative pressure on the roof of the plastic greenhouse increased significantly in 2017 code draft. (2) Since the existing members could not meet the design requirements, the rafters had to be replaced with members of the same cross-section as the columns. (3) Due to excessive lifting, measures were also needed to prevent lifting at the foundation of the plastic greenhouse.
In this study, the Relux program was simulated for optimum conditions of daylight and artificial light sources(LED) in the glass greenhouse. From the results of daylight simulation, the optimum design conditions for the glass greenhouse were established which were 90[o] installation angle and higher transmittance. In this case of growing lettuce in the glass greenhouse, the control method of the only artificial light source was compared that of daylight and LED. The result of illumination simulation produced a power consumption effect of 37.2[%] in the summer and 51.9[%] in the winter, respectively. From this results, we propose to suggest that we grow the lettuce in the energy saving glass greenhouse.
Korean medicinal herb extracts(KMHE) were applied to the preservation of greenhouse produce in order to prove their effectiveness. KMHE showed remarkable antimicrobial effects against Bacillus cereus, Peudomonas syringae, and Corynebacterium xerosis causing the postharvest decay of greenhouse produce. Among KMHE the extracts of Rheum palmatum L. and Coptis chinensis Franch most obviously inhibited the growth of microorganims causing the Postharvest decay of greenhouse produce, which destroyed to undetectable levels when treated with more than 500ppm of KMHE. The activities of KMHE were stable in the wide spectrum of pH and temperature. Direct visualization of microbial cells by using both transmission electron microscope and scanning electron microscope showed microbial cell membrane the function of which was destroyed by treating with the dilute solutions of KMHE. This change of cellular membrane permeability could be identified in the experiment that O-nitrophenyl-$\beta$-D-galactopyranoside(ONPG), the artificial substrate of $\beta$-galactosidase, was hydrolyzed in the presence of KMHE, indicating that the membrane was perturbed by KMHE.
It is desirable to use the renewable energy for the greenhouse heating in winter season, it make possible not only to save fossil fuel and conserve green environment but also to promote the quality of agricultural products and reduce the agricultural production cost. In this study the heat pump - PCM latent heat storage system has been developed to use the natural energy as much as possible for the thermal environment control of greenhouse. The coefficient of performance (COP) of the heat pump system was 3~4 with the ambient temperature ranging from 8$^{\circ}C$ to -8$^{\circ}C$, and greenhouse heating effect of the heat pump-PCM latent heat storage system on the basis of the ambient temperature was about 12-15$^{\circ}C$.
본 연구는 공기주입 이중피복온실과 관행 이중피복온실의 생육환경과 단열성능을 비교하기 위하여 수행하였다. 두 온실의 온도, 상대습도, 포차, 이산화탄소농도, 일사량, 딸기 생산량 및 난방연료소비량을 비교하였다. 공기주입온실이 관행온실보다 야간에 상대습도가 더 높고 포차는 더 낮게 나타나 딸기의 생육에 좋지 않은 환경을 보여주었다. 이산화탄소농도는 공기주입온실이 관행온실보다 더 높게 나타났으며, 이는 공기주입온실이 더 밀폐되어 있어 환기량이 적기 때문인 것으로 판단된다. 관행온실의 광투과율이 77%로 공기주입온실의 72%보다 더 높아 관행온실의 광환경이 더 우수한 것으로 나타났다. 관행온실의 딸기 생산량이 더 높게 나타났으며, 이는 관행온실의 생육환경이 공기주입온실보다 더 우수한 결과로 판단된다. 난방연료는 공기주입온실에서 더 적게 소모되어 공기주입온실의 단열성능이 더 우수한 것으로 나타났다.
여름철에 자연환기는 온실의 온도를 낮추는데 중요한 역할을 한다. 온실의 형태, 환기창 종류, 환기창의 위치 등은 자연환기 성능에 큰 영향을 미친다. 본 연구에서는 전산유체역학(CFD)을 이용하여 다양한 천창구조에 대하여 측창에 따른 부력환기 효과를 비교분석 하였다. Boussinnesq 가정을 사용하여 전체 계산영역에 대한 부력효과를 시뮬레이션 하였다. 또한 RNG $K-{\varepsilon}$ 난류모델을 사용하였다. 일사량 효과를 시뮬레이션 하기 위해 Solar ray tracing과 함께 Discrete originates (DO) radiation 모델을 사용하였다. 실험온실 내부의 온도를 측정하여 CFD모델을 검증하였으며, 실험값과 계산값이 잘 일치하는 것으로 나타났다. 7가지의 천창구조에 대하여 온실의 내외부 온도차이와 환기횟수를 비교하였다. 내외부온도의 차이는 $3.2{\sim}9.6^{\circ}C$ 범위로 나타났고, 환기횟수는 $0.33{\sim}0.49min^{-1}$ 범위로 나타났다. 고깔형 천창구조 온실의 경우 내외부 온도차이가 $3.2^{\circ}C$로 가장 낮았고 환기횟수도 $0.49min^{-1}$로 가장 높게 나타나 환기효과가 가장 우수한 것으로 나타났다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.