• Title/Summary/Keyword: green wall

Search Result 307, Processing Time 0.025 seconds

Detection of Virus in Fruit and Seed of Vegetables Using RT-PCR (RT-PCR에 의한 과채류 열매 및 종자의 바이러스 검정)

  • 최장경;김혜자;윤주연;박선정;김두욱;이상용
    • Korean Journal Plant Pathology
    • /
    • v.14 no.6
    • /
    • pp.630-635
    • /
    • 1998
  • Tobacco mosaic tobamovirus (TMV), cucumber mosaic cucumovirus (CMV), cucumber green mottle mosaic tobamovirus (CGMMV) and zucchini yellow mosaic potyvirus (ZYMV) from individual fruits and seeds of hot pepper and cucumber were detected by the reverse transcription-polymerase chain reaction (RT-PCR). The dilution end-points for RT-PCR in curde sap from TMV. and CMV - infected hot pepper leaves and CMV - and CGMMV-infected cucumber leaves were 10-5. However, the amount of PCR product obtained from preparation of ZYMV-infected cucumber leaf was 10-fold lower than those of CMV or CGMMV-infected cucumber leaves. In hot pepper, both TMV and CMV were detected in all parts of the fruit wall tissue, but the yields of PCR products in the fruit stalk and its surrounding tissues were higher than those of the end parts of the fruit. On the other hand, in cucumber fruit infected with CMV, CGMMV or ZYMV, the fruit wall tissue and seed located in both stalk and end parts showed higher yields of PCR products than those of intermediate parts. Of five viruses that were analysed, only TMV in hot pepper seed, and CGMMV and CMV in cucumber seed were detected in testa parts.

  • PDF

Nonlinear modeling parameters of RC coupling beams in a coupled wall system

  • Gwon, Seongwoo;Shin, Myoungsu;Pimentel, Benjamin;Lee, Deokjung
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.817-842
    • /
    • 2014
  • ASCE/SEI 41-13 provides modeling parameters and numerical acceptance criteria for various types of members that are useful for evaluating the seismic performance of reinforced concrete (RC) building structures. To accurately evaluate the global performance of a coupled wall system, it is crucial to first properly define the component behaviors (i.e., force-displacement relationships of shear walls and coupling beams). However, only a few studies have investigated on the modeling of RC coupling beams subjected to earthquake loading to date. The main objective of this study is to assess the reliability of ASCE 41-13 modeling parameters specified for RC coupling beams with various design details, based on a database compiling almost all coupling beam tests available worldwide. Several recently developed coupling beam models are also reviewed. Finally, a rational method is proposed for determining the chord yield rotation of RC coupling beams.

Analysis of the Types of External Wall and Roof Structure Layer Composition of CLT Building (CLT 건축물의 외벽 및 지붕 구조체 레이어 구성 유형 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.4
    • /
    • pp.71-78
    • /
    • 2020
  • Today, the whole world is going through a big chaos due to the COVID-19, but paradoxically, the emergence of COVID-19 has been leading to the need for sustainable development, such as Green New Deal that can improve global warming and carbon emissions, and the need for sustainable architecture is growing bigger and bigger in the architectural field as well. The level of CLT buildings in Korea is at a very rudimentary stage, while CLT buildings remedying existing wooden buildings are getting the spotlight among European countries for sustainable architecture. This study was conducted to categorize structure layer compositions of overseas CLT buildings and analyze architectural techniques and materials applied by collecting and analyzing information about CLT structure layer compositions of overseas CLT building-related institutions, companies and cases. When classifying structure layer compositions of foreign CLT buildings depending on the roles of layers. it was revealed that exterior wall structure layers were combined and organized within a sequence of external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, sloped roof structure layers were external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, flat roof structure layers were external finishing, ventilation, waterproof, planking wood, external insulation, waterproof, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing.

A basic study on the Eco-friendly elements evaluation of Hanok according to G-SEED -Focus on the Unjoru and Jinwondang- (녹색건축인증제(G-SEED)에 따른 한옥의 친환경 요소 평가에 관한 기초연구 -구례 운조루와 진원당을 중심으로-)

  • Choi, Hyung-Seok;Kim, Hark-Rae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.9-18
    • /
    • 2015
  • The purpose of this study is to analyze the usage of eco-friendly elements in Korean traditional architecture to evaluate Hanok(Unjoru and Jinwondang) according to Green Building Certification Criteria(G-SEED). The results of this study were as follows; Unjoru and Jinwondang was not enough to obtain certification points. From Site usage and Traffic category, Jinwondang gets more points than Unjoru. It's because Jinwondang is located in downtown Seoul, so it gets more points of traffic and neighborhood facility. From Energy and Environmental Pollution category, Jinwondang gets more points of energy performance than Unjoru, too. It's because Jinwondang secured insulation performance of wall and windows using insulator and glass. From Resources category, Unjoru gets more points than Jinwondang. It shows that modern Hanok was limited using natural resources. From Ecological Environments category, Jinwondang is located urban area, it's difficult to secure the open space, so Unjoru gets more points than Jinwondang. If Modern Honok installs a system that can getting point and secure insulation performance, it will be certificated according to G-SEED.

The Improvement of Building Envelope Performance in Existing School Building (기존 학교 건물의 외피 성능 개선 방안에 관한 연구)

  • Bang, Ah-Young;Park, Se-Hyeon;Kim, Jin-Hee;Kim, Young-Jae;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: This study is to investigate the effects of facade insulation and window remodeling of an existing old middle school building on the reduction of energy consumption. Method: To analyze energy performance of building, using DesignBuilder v3.4, building energy simulation tool based EnergyPlus engine. Energy consumption and problem of target building was analyzed based on data and survey. Based on building energy simulations it analyzed the variation of energy demand for the building according to U-value of wall, glazing properties and external shading devices. Result: When insulation of building was reinforced, cooling and heating load was decreased. Glazing properties that minimize cooling and heating energy consumption were analyzed. In conclusion, it is important to choose SHGC and U-value of window fit in characteristic of target building. Setting external blind for cooling load decreases 5%.

An Ultrastructural Investigation of Infection Threads in Sesbania rostrata Stem Nodules Induced by Sinorhizobium sp. Strain MUS10

  • Krishnan Hari B.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Sinorhizobium sp. strain MUS10 forms nitrogen-fixing stem nodules on Sesbania rostrata, a tropical green manure crop. In this study, the ultrastructural events associated with the formation of stem nodules were investigated. Sinorhizobium sp. strain MUS10 entered the host tissue through cracks created by the emerging adventitious root primordia and multiplied within the intercellular spaces. During early phases of infection, host cells adjacent to invading bacteria revealed cellular damage that is typical of hypersensitive reactions, while the cells at the inner cortex exhibited meristematic activity. Infection threads were numerous in S-day-old nodules and often were associated with the host cell wall. In several cases, more than one infection thread was found in individual cells. The junction at which the host cell walls converged was often enlarged due to fusion of intracellular branches of infection threads resulting in large infection pockets. The infection threads were made up of a homogeneous, amorphous matrix that enclosed the bacteria. Several finger-like projections were seen radiating from these enlarged infection threads and were delineated from the host cytoplasm by the plasma membrane. As in Azorhizobium caulinodans induced root nodules, the release of Sinorhizobia from the infection threads into the plant cells appears to be mediated by 'infection droplets'. A 15-day­old Sesbania stem nodule revealed typical ultrastructure features of a determinate nodule, containing several bacterioids within symbiosomes.

Real Survey on Interior Surface Area and Applied Finishes in Recently-Planned Apartment Houses (공동주택의 실내부 표면적 및 사용 마감재 구성 실태분석)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2010
  • This paper is an outgrowth of many years of practicing real interior work projects and one of my responses to the question not only about the actual dimension of interior work surface but also about the classification of contemporary finishing materials in basic interior project of high-rise apartment houses. For this purpose, 8 conventional apartment units which are already-built or designed have been surveyed and the results are interpreted in the form of proportion of space and finishes. The data can be applied to make up a schematic design in the selection of environment-friendly interior works and assessment of the degree of sustainability. For further study, the basic data provided here can be used as an index to differentiate the occupants' desire toward green interior design for their own apartment spaces, comparing to the conventional interior work in the Korean market. Not surprisingly, wall paper is dominated to make the interior surface in apartment houses. In the percentile of the utilization of finishing materials, wood-flooring and coating materials like wet paint also ranked at the upper position.

The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling (사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석)

  • Choi, Seon woo;Kim, Ji Yeon;Park, Hyo soon;Kim, Jun Tae
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling (그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구)

  • Kim, Woong-Hoi;Kang, Eun-Ho;Yoon, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

Encapsulation of Avocado Oil Using Spray Drying (분무건조를 이용한 아보카도 오일의 캡슐화)

  • Bae, Eun-Kyung;Kim, Gun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.303-310
    • /
    • 2008
  • This study was performed to verify the effects of encapsulation against oil oxidation. Thiobarbituric acid (TBA) values of samples were compared during storage at $60^{\circ}C$, indicating that the encapsulated avocado oil had lower TBA values than the free avocado oil. Microcapsules consisting of a whey protein isolate (WPI)-only wall system had slightly improved oxidative stability; however, spray-dried particles containing a high proportion of maltodextrin (MD) clearly offered better protection from oxidation than the other forms of encapsulation. The chlorophyll (Chl) content of the encapsulated avocado oil was higher than that of the free oil sample. When compared to the control, all wall systems protected the change of the chlorophyll content storage. No large differences were observed between the encapsulated powders according to the various wall materials. The color of the encapsulated oil changed from green to yellowish-green, indicating the formation of pheophytin from chlorophyll. The yellowish color of the oil correlated with a reduced total Chl content. In conclusion, encapsulation with spray drying for avocado oil could lead to improved stability during storage with respect to oxidation and the preservation of chlorophyll.