• 제목/요약/키워드: gravity wall

검색결과 185건 처리시간 0.023초

Compressibility and hydraulic conductivity of calcium bentonite treated with pH-responsive polymer

  • Choo, Hyunwook;Choi, Youngmin;Kim, Young-Uk;Lee, Woojin;Lee, Changho
    • Geomechanics and Engineering
    • /
    • 제22권4호
    • /
    • pp.329-337
    • /
    • 2020
  • Polyacrylamide (PAM) possesses high water absorption capacity and a unique pH-dependent behavior that confer large potential to enhance the engineering performance of clays. In this study, calcium bentonite was treated with a nonionic PAM. Flexible-wall permeability test and the consolidation test were performed at different pH values to evaluate the effects of PAM treatment on the hydraulic and consolidation properties. Test results demonstrate that index properties are affected by the adsorbed PAM on clay surface: a decrease in specific gravity, a decrease in net zeta potential, and an increase in liquid limit are observed due to the PAM treatment. At a given pH, the compressibility of the treated clay is greater than that of the untreated clay. However, the compression indices of untreated and treated clays can be expressed as a single function of the initial void ratio, regardless of pH. Hydraulic conductivity is reduced by PAM treatment about 5 times at both neutral and alkaline pH conditions under similar void ratios, because of the reduction in size of the water flow channel by PAM expansion. However, at acidic pH, the hydraulic conductivity of the treated clay is slightly higher than the untreated clay. This reflects that the treated bentonite with PAM can be beneficially used in barrier system for highly alkaline residues.

사각 밀폐용기 내부의 밀도최대치를 가지는 유체의 공진현상 (Oscillatory enclosed buoyant convection of a fluid with the density maximum)

  • 이창호;현재민;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.311-315
    • /
    • 2000
  • A numerical investigation is made of time-dependent buoyant convection in a square of a non-Boussinesq fluid. The density-temperature$({\rho}-T)$ relation is modeled by a quadratic function, with the maximum density ${\rho}_M$ at temperature $T_M$. The horizontal walls of the square are insulated, and a pulsating temperature $T_H=T_M+{\Delta}T'\;sin({\omega}{\tau})$ is imposed on the hot vertical sidewall. The temperature at the cold wall $T_c$ is constant. Extensive numerical solutions to the governing Navier-Stokes equations are portrayed. Resonance is identified by monitoring the amplitude of the mid-plane Nusselt number, $A(Nu^*)$. The primary resonance frequency is found by matching ${\omega}$ to the nondimensional basic mode $N_1$ of internal gravity oscillations. Due to the quadratic$({\rho}-T)$ relationship, the effective pulsation frequency for density, $2{\omega}$, is meaningful, which brings forth the secondary resonance frequency, i.e., $2{\omega}=N_1$

  • PDF

연속섬유보강토공법의 하천구역 적용사례에 관한 연구 (Application of Continuous Fiber Soil Reinforcement System in Riparian Slopes)

  • 고정현;허영진;최재용
    • 한국환경복원기술학회지
    • /
    • 제14권3호
    • /
    • pp.169-176
    • /
    • 2011
  • The purpose of this study is to examine the ecologically suitable restoration characteristics in riparian slopes constructed by continuous fiber soil reinforced system (Geofiber system) which does not contain the concrete materials. The findings are as follows : (1) as the tested soil was not washed away by rainfalls and floods, Geofiber could replace the concrete wall and gravity stone net bag technique from the civil engineering structural point of view; (2) after one year of the construction, it was monitored that land cover ratio was 80-90%, which indirectly shows that vegetation is safely maintained; and (3) at the same time, 5-8 flora species were found in each test grid and more importantly dominant species have been moved from alien species to native herbaceous plants. From the above findings, Geofiber system is recommendable to restore the riparian slopes in terms of stability and natural landscape points. However, a long term monitering is needed considering flora succession process in a given environment as well as suitability tests should be carried out through the comparative investigations in other environments.

EPS블럭의 현장적용에 따른 하부지반의 거동 연구 (A Case of Field Application of EPS Blocks and Its Performance)

  • 장용채
    • 한국지반공학회지:지반
    • /
    • 제14권1호
    • /
    • pp.15-28
    • /
    • 1998
  • 우리나라에 EPS성토공법의 도입은 1993년 서해안 고속도로현장에서 시작된 이후 비록 초창기 이지만, 지형적인 특성 때문에 짤은 기간동안에 약 21만m3의 EPS블럭을 시공하였다. 국내에 사용 된 EPS성토공법의 주적용분야는 연약지반상의 교량교대 됫채움 및 성토체분야로 EPS블럭 전체 사용량의 약 70%정도를 차지하고 있으며, 나머지는 옹벽 등에 사용되었다. 본 연구에서는 주 적용 분야인 교량교대 됫채움 부분에 EPS블럭을 적용하여 구조물의 안정을 이룬 시험시공구간을 대상으로 토압, 간극수압 및 변위량 등의 계측결과를 분석 검토하였다. 교량 교대에 각종 계측기를 매설하여 교량 교대와 배면 토공부의 거동을 파악하고 유한요소해석 프로그램을 이용하여 이들의 거동을 예측하였다.

  • PDF

유한요소법을 이용한 주상복합건물의 강막작용에 의한 영향 평가 (Evaluation of Diaphragm Effect for Hybrid Structural Systems Using Finite Element Method)

  • 김희철;최성우;홍원기
    • 한국전산구조공학회논문집
    • /
    • 제16권1호
    • /
    • pp.19-32
    • /
    • 2003
  • 주상복합건물의 구조시스템은 휨변형에 의해 횡력에 저항하는 전단벽 구조와 전단변형에 의해 저항하는 라멘구조의 복합구조로 이루어져 있으며, 이 두 구조의 원활한 힘의 전달을 위하여 전이층에 주로 춤이 큰 보를 사용한다. 주상복합건물은 이러한 큰 질량과 강성을 갖는 전이층으로 인하여 유한요소법에 의한 해석 시 동적 해석을 수행하여야 하며, 일반적인 해석 절차로는 해결하기 어려운 많은 문제점을 야기한다. 일반적으로 주상복한건물의 해석시 전이층 바닥판은 강막을 적용하거나 판요소로 직접 입력하나 적절한 평가없이 사용되고 있다. 따라서 본 연구에서는 강막 적용에 따른 영향을 평가하여 올바른 해석 방법을 제시한다.

Topology optimization of the photovoltaic panel connector in high-rise buildings

  • Lu, Xilin;Xu, Jiaqi;Zhang, Hongmei;Wei, Peng
    • Structural Engineering and Mechanics
    • /
    • 제62권4호
    • /
    • pp.465-475
    • /
    • 2017
  • Photovoltaic (PV) panels are used in high-rise buildings to convert solar energy to electricity. Due to the considerable energy consumption of high-rise buildings, applying PV technology is of great significance to energy saving. In the application of PV panels, one of the most important construction issues is the connection of the PV panel with the main structures. One major difficulty of the connection design is that the PV panel connection consists of two separate components with coupling and indeterminate dimension. In this paper, the gap element is employed in these two separated but coupled components, i.e., hook and catch. Topology optimization is applied to optimize and design the cross-section of the PV panel connection. Pareto optimization is conducted to operate the optimization subject to multiple load scenarios. The initial design for the topology optimization is determined by the common design specified by the Technical Code for Glass Curtain Wall Engineering (JGJ 102-2003). Gravity and wind load scenarios are considered for the optimization and numerical analysis. Post analysis is conducted for the optimal design obtained by the topology optimization due to the manufactory requirements. Generally, compared with the conventional design, the optimized connector reduces material use with improved structural characteristics.

Radian of the vault influencing the seismic performances of straight wall arch underground structures

  • Ma, Chao;Lu, Dechun;Qi, Chengzhi;Du, Xiuli
    • Structural Engineering and Mechanics
    • /
    • 제78권5호
    • /
    • pp.637-649
    • /
    • 2021
  • Great efforts have been conducted to investigate the seismic performances of the arch and rectangular underground structures, however, the differences between seismic responses of these two types of underground structures, especially the vault radian influencing the seismic responses of arch structures are not clarified. This paper presents a detailed numerical investigation on the seismic responses of arch underground structures with different vault radians, and aims to illustrate the rule that vault radian affects the seismic responses of underground structures. Five arch underground structures are built for nonlinear soil-structure interaction analysis. The internal forces of the structural components of the underground structures only under gravity are discussed detailedly, and an optimum vault radian for perfect load-carrying functionality of arch underground structures is suggested. Then the structures are analyzed under seven scaled ground motions, amounting to a total of 35 dynamic calculations. The numerical results show that the vault radian can have beneficial effects on the seismic response of the arch structure, compared to the rectangular underground structures, causing the central columns to suffer smaller axial force and horizontal deformation. The conclusions provide some directive suggestions for the seismic design of the arch underground structures.

스마트 폰 기반 3D 프린팅 칩을 이용한 적혈구 변형성 측정 (Measurement of RBC (red blood cell) deformability using 3D Printed Chip combined with Smartphone)

  • 이수환;홍현지;염은섭;송재민
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.103-108
    • /
    • 2020
  • RBC (red blood cell) deformability is one of factors inducing blood shear thinning effect. Reduction of RBC deformability increases blood viscosity in high shear region. In this study, 3D printed chip with proper distribution of wall shear rate (WSR) was proposed to measure RBC deformability of blood samples. To fabricate 3D printed chip, the design of 3D printed chip determined through numerical simulation was modified based on the resolution of the 3D printer. For the estimation of pressure drop in the 3D printed chip, two bypass outlets with low and high WSR are exposed to atmospheric pressure through the needles. By positioning the outlet of needles in the gravity direction, the formation of droplets at bypass outlets can be captured by smartphone. Through image processing and fast Fourier transform (FFT) analysis, the frequency of droplet formation was analyzed. Since the frequency of droplet formation is related with the pressure at bypass, high pressure drop caused by reduction of RBC deformability can be estimated by monitoring the formation of blood droplets using the smartphone.

코어 위치 변화에 따른 비틀림 초고층 구조물의 동적응답분석 (Dynamic Response Analysis of Twisted High-Rise Structures according to the Core Location Change)

  • 채영원;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제22권1호
    • /
    • pp.17-24
    • /
    • 2022
  • Currently, the construction trend of high-rise structures is changing from a cube-shaped box to a free-form. In the case of free-form structures, it is difficult to predict the behavior of the structure because it induces torsional deformation due to inclined columns and the eccentricity of the structure by the horizontal load. For this reason, it is essential to review the stability by considering the design variables at the design stage. In this paper, the position of the weak vertical member was analyzed by analyzing the behavior of the structure according to the change in the core position of the twisted high-rise structures. In the case of the shear wall, the shear force was found to be high in the order of proximity to the center of gravity of each floor of the structure. In the case of the column, the component force was generated by the axial force of the outermost beam, so the bending moment was concentrated on the inner column with no inclination.

Reliability analysis of external and internal stability of reinforced soil under static and seismic loads

  • Ahmadi, Rebin;Jahromi, Saeed Ghaffarpour;Shabakhty, Naser
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.599-614
    • /
    • 2022
  • In this study, the reliability analysis of internal and external stabilities of Reinforced Soil Walls (RSWs) under static and seismic loads are investigated so that it can help the geotechnical engineers to perform the design more realistically. The effect of various variables such as angle of internal soil friction, soil specific gravity, tensile strength of the reinforcements, base friction, surcharge load and finally horizontal earthquake acceleration are examined assuming the variables uncertainties. Also, the correlation coefficient impact between variables, sensitivity analysis, mean change, coefficient of variation and type of probability distribution function were evaluated. In this research, external stability (sliding, overturning and bearing capacity) and internal stability (tensile rupture and pull out) in both static and seismic conditions were investigated. Results of this study indicated sliding as the predominant failure mode in the external stability and reinforcing rupture in the internal stability. First-Order Reliability Method (FORM) are applied to estimate the reliability index (or failure probability) and results are validated using the Monte Carlo Simulation (MCS) method. The results showed among all variables, the internal friction angle and horizontal earthquake acceleration have dominant impact on the both reinforced soil wall internal and external stabilities limit states. Also, the type of probability distribution function affects the reliability index significantly and coefficient of variation of internal friction angle has the greatest influence in the static and seismic limits states compared to the other variables.