• Title/Summary/Keyword: grass concrete

Search Result 37, Processing Time 0.022 seconds

Planting-Ability Valuation of Porous Concrete Using Industrial By-Products (산업부산물을 이용한 포러스콘크리트의 식생능력평가)

  • 박승범;이봉춘;김정환;윤덕열
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.623-629
    • /
    • 2002
  • Porous concrete enables water and air to pass through a firmly hardened material and allows required nutrients to reach roots of plants. The purpose of this study is to analyze void ratio, strength property and planting ability when using silica fume and fly ash, the change of aggregate gradation and ratio of paste to aggregate. The results of an experiment from the planting ability of the porous concrete to its influence on the compressive strength are reported in this paper. As a result of the experiment, the compressive strength is higher when the gradation of aggregate is smaller, and it also goes higher when the ratio of paste to aggregate gets larger. The planting ability of porous concrete is decided by the germination and the grass length of perennial ryegrass. The grass length of perennial ryegrass is longer when the gradation of aggregate is greater and the ratio of paste to aggregate gets smaller. Therefore the efficiency of planting goes through the perennial ryegrass is in compliance with the void ratio, aggregate gradation.

A Study on Test Method for Evaluating Root Resistance in Waterproofing and Root Resistance Membrane Used in Landscape Architecture - A Test Method for Evaluating Root Resistance that Use a Simulated Needle and a Rhizome - (조경 녹화용 방수.방근층의 방근 성능평가 시험방법에 관한 연구 - 모의 바늘과 지하경을 이용한 방근 성능평가 시험방법 -)

  • Yi, Jun-Ho;Pyo, Soon-Ju;Shin, Jin-Hak;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.89-97
    • /
    • 2009
  • As landscaping building roofs and concrete structures increase gradually for low carbon green growth policy of government, But waterproofing membranes of those structures are effecting by root penetration of landscape plant. 80, we progressed study about test method for fast evaluating root resistance of waterproofing materials jointly with Tokyo Institute of Technology. The result of the study is as follows: (1) The penetrating load of the needle at the displacement speed of 1mm/min was measured for various membrane to basis and lap joints of membrane, the load force was $3{\sim}50$ N by material variously. (2) According to the test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane, there were no penetrated membrane until present, but need persistent observation. (3) Test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane can shorten from period of 2 years to 1 year for testing. Because rhizomes of bamboo grass can grow from May to September, test is possible in same period.

  • PDF

Impacts of Different Urban Surfaces on Summer Thermal Performance

  • Jo, Hyun-Kil;Wu, Qian
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.819-826
    • /
    • 2015
  • This study measured temperatures and albedos of urban surfaces for different colors and materials during summer, and calculated the energy budget over different urban surfaces to find out the thermal performance affecting the heat built-up. The study selected six surface colors and 13 materials common in urban landscape. Their surface temperatures (Ts) and albedos were measured at a given time interval in the daytime from June to August. Average Ts over summer season for asphalt-colored brick was $4.0^{\circ}C$ higher than that for light red-colored one and $9.7^{\circ}C$ higher than that for white-colored one. The Ts for artificial surface materials of asphalt paving, brown brick wall, and green concrete wall was $6.0^{\circ}C$ higher than that for natural and semi-natural ones of grass, grassy block, and planted concrete wall. There was the greatest difference of $16.3^{\circ}C$ at midafternoon in the Ts between asphalt paving and planted concrete wall. Average albedo over summer season of surface materials ranged from 0.08 for asphalt paving to 0.67 for white concrete wall. This difference in the albedo was associated with a maximum of $15.7^{\circ}C$ difference at midafternoon in the Ts. Increasing the albedo by 0.1 (from 0.22 to 0.32) reduced the Ts by about $1.3^{\circ}C$. Average storage heat at midday by natural and semi-natural surfaces of grass and grassy block was about 10% lower than that by artificial ones of asphalt, light-red brick, and concrete. Reflected radiation, which ultimately contributes to heating the urban atmosphere, was 3.7 times greater for light-red brick and concrete surfaces than for asphalt surface. Thus, surfaces with in-between tone and color are more effective than dark- or white-colored ones, and natural or semi-natural surfaces are much greater than artificial ones in improving the urban thermal environment. This study provides new information on correlation between Ts and air temperature, relationship between albedo and Ts, and the energy budget.

Planting-Ability Properties of Porous Concrete as Gradation and Void Ratio (포러스콘크리트의 골재입도 및 공극률에 따른 식생능력평가)

  • 윤덕열;김정환;조영수;표구영;박승범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.243-248
    • /
    • 2002
  • As a notion of environment protection changes throughout the world, construction engineers, as part of the effort to resolve environmental problems, have been actively doing research on environmental friendly porous concrete using large and non-uniform aggregate. Porous Concrete enables water and air to pass through a firmly hardened material and allows required nutrients to reach roots of plants. The purpose of this study is to analyze planting ability when the change of aggregate gradation and void ratio. The results of an experiment from the planting ability of the porous concrete to its influence on the compressive strength are reported in this paper. As a result of the experiment, the compressive strength is higher when the gradation of aggregate is smaller, and it also goes higher when the void ratio gets smaller The planting ability of porous concrete is decided by the germination and the grass length of Indigofera pseudo-tinctoria(IPT). The length of IPT is longer when the gradation of aggregate is greater and the void ratio gets smaller.

  • PDF

The Fundamental Properties and Planting Experiments on the Concrete with Continuous voids (다공성콘크리트의 기초적 특성과 녹화실험)

  • 김진춘;김기수;최광일;오희갑
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.153-159
    • /
    • 1996
  • The concrete with continuous voids (No Fine Concrete ; NFC) is the new planting material which may be used for stabilizing the sandy slope of river or road sides. The components of NFC are mainly coarse aggregate and low alkali cement paste, so to speak fine aggregate is not used. This report shows the fundamental properties of NFC, such as continous void ratio, compressive strength, permeability. As experimental results we can get the good quality of NFC, that is about 28% continuous void ratio, about 120kg/$\textrm{cm}^2$ compressive strength and high flowable permeability. And also planting grass and garden portulaca on the concrete with continuous voids is resulted in success.

  • PDF

Void Ratio and Strength of Porous Polymer Concrete and Initial Growth Properties within Planting Block with Binder Contents (결합재량에 따른 포러스 폴리머 콘크리트의 공극률과 강도 및 식생 블록 내 초기 생장 특성)

  • Sung, Chan-Yong;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.101-110
    • /
    • 2010
  • This study was performed to evaluate the void ratio and strength of porous polymer concrete used coarse aggregates and unsaturated polyester resin to find optimum mix design of porous polymer concrete for planting block. Also, this study was performed to evaluate the planting properties of herbaceous plant and cool-season grass in porous polymer blocks based on the experimental results of porous polymer concrete to develop environmentally friendly planting blocks. Tests for the void ratio and compressive strength of porous polymer concrete were performed at the curing age 7 days. Also, kinds of plants such as Tall fescue, Perennial ryegrass, Lespedeza and Alfalfa for planting were applied to porous polymer blocks. Within 6 weeks after seed, initial germination ratio, cover view and growth length for planting blocks were estimated by various methods.

A Planting Study on the Development of Eco-friendly Reinforced Earth-Retaining Wall Using Planting Green Net (환경친화형 그린넷 보강토 옹벽 개발을 위한 식생시험 연구)

  • Chung, Dae-Seouk
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1099-1102
    • /
    • 2007
  • This paper presents eco-friendly planting method to overcome the problems of existing concrete retaining wall and gabion retaining wall, respectively, based on the examination on existing concrete and gabion retaining wall. Prior to doing this, proper design method was provided through pull out test. Planting method using gabion metal net and L shape green net retaining wall were compared and analyzed. According to this study, it is confirmed that reduction of construction period and economical profit in construction can be achieved by both manufacturing at the factory and self procurement at the job site as well as the use of metal net, which is applied as a substitution of existing strengthening material. For the effect of planting method, the use of L shape green net retaining wall shows superiority to environment-friendly gabion retaining wall in its ability to rootage and germination of the grass. The L shape green net retaining wall had excellent performance in helping rootage of grass and prevention of soil leakage, and even if raining period, remarkable damage of planting mat does not occur when planting mat is applied.

Invention and Hydraulic Model Test of Combined Block System in River Bank Protection (일체형 하천호안블럭의 개발 및 모형실험 적용)

  • Jang, Suk-Hwan;Lee, Chang-Hae;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.449-453
    • /
    • 2008
  • This research focused on analyzing and comparing between the results of hydraulic physical modeling and the results of numerical modeling of Grass Concrete which is newly developed in-situ block system. The physical model was built as a scale of 1:50 by Froude similitude measuring the water levels and the water velocities for before and after vegetation and the effects were analyzed after reviewing the results. In consequence, the water velocities were observed to decrease meanly 19.1%, and the water depth were determined to increase meanly 27.8% in case of the of design flood, $Q=200m^3/sec$. Moreover, the velocities were produced reduction effects of 27.2%, and the water levels were derived from addition effects of the highest 31.3% in case of the probability maximum flood(PMF), $Q=600m^3/sec$. To verifying the hydraulic physical modeling, the numerical modeling was conducted for a close examination of before and after vegetation. HEC-RAS model was for 1 dimensional numerical analysis and RMA-2 was for 2 dimensional numerical analysis. The results of the numerical simulation, under the condition of roughness coefficient calibration, shows similar results of the physical modeling. These satisfactory results show that the accomplished results of hydraulic modeling and the predicted results of numerical modeling corresponded reasonably each others.

  • PDF

Function of Microclimate Amelioration by Urban Greenspace (도시녹지에 의한 미기후개선의 기능)

  • 조현길;안태원
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.4
    • /
    • pp.23-28
    • /
    • 1999
  • This study measured transpiration rate of urban trees and albedos of urban surfaces, and examined the function of microclimate amelioration by urban greenspace. Transpiration rates of trees were highest in July and August of growing months. Transpiration per unit leaf area for the two months was 300-350 g/$m^2$/h for Platanus occidentalis, 210-270 g/$m^2$/h for Ginkgo biloba and Zelkova serrata, and 130-140 g/$m^2$/h for Acer palmatum. Surface albedos were 0.09 for asphalt paving and 0.68 for white wall, which reveals that light-colored surfaces are better than dark-colored ones to lower the heat build-up. Due to lack of evapotranspiration, concrete surfaces were, at t midafternoon maximum, 8$^{\circ}C$ hotter than grass ones, though the albedo of concrete paving was higher thant that of grass and trees. Summer air temperatures at places with 12% and 22% cover of woody plants were, respectively, 0.6$^{\circ}C$ and 1.4$^{\circ}C$ cooler than a place with no vegetation. To mitigate the impacts of urban heat islands, required are minimization of hard surfaces, light-coloring for building surfaces, and greenspace enlargement including more plantings.

  • PDF

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.