• Title/Summary/Keyword: grafting degree

Search Result 109, Processing Time 0.021 seconds

A Study on Performance Improvement of Fruit Vegetables Automatic Grafting System (과채류 접목시스템 개선 연구)

  • Kang, Dong Hyeon;Lee, Si Young;Kim, Jong Koo;Park, Min Jung;Son, Jin Kwan;Yun, Sung-Wook;An, Se Woong;Jung, In Kyu
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.215-220
    • /
    • 2017
  • This study was conducted to improve the insufficiency of fruit vegetable grafting system developed by National Institute of Agricultural Sciences, Rural Development Administration. When the rotary blade cut the stem of scions and rootstocks, the grafting failure at curved cutting surfaces happened. The cutting depth of a tomato seedling by a rotated cutter was calculated 0.11 mm even when the cutting arm length and the maximum stem diameter were 50 mm and 5 mm, respectively. Mathematical analysis and high-speed photography showed that there was no problem by cutting in straight the stem of scions and rootstocks. The compression test of seedling stems to design the optimal shape of gripper showed that stems were not completely restored when they were compressed above 0.8 mm and 0.6 mm in case of rootstocks and scion, respectively. This study found that the bending angle of stem of tomato seedlings at the grafting period was 10 degree on average. The optimal gripper finger was the edge finger type which could be precisely set center point by adjusting the distance between fingers. In addition, it was found that most of seedling could be grasped without damage when the finger-to-finger distances is set to 2.5 mm for scion and 3.0 mm for rootstocks and finger are coated by 1 mm-thick flexible material.

Study on Physical Properties of Maleic anhydride Grafted Polypropylene (PP)/Kenaf Fiber (KF) Composites (말레인산 무수물 그래프트 폴리프로필렌/케나프 섬유 복합체의 물성에 대한 연구)

  • Ku, Sun Gyo;Kim, Yu Shin;Hong, Young Eun;Kim, Dong Won;Kim, Ki Sung;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.73-79
    • /
    • 2017
  • Maleic anhydride (MAH) grafted polypropylene (PP-g-MAH) copolymers were prepared by changing MAH and styrene monomer (SM) content, using a twin screw extruder at $190^{\circ}C$. The grafting degree was measured by non-aqueous back titration method. The grafting degree of PP-g-MAH-SM copolymer was higher than that of PP-g-MAH at the same MAH content. PP-g-MAH-SM/kenaf fiber (KF) composites were also prepared by using a PP-g-MAH as a matrix at $200^{\circ}C$ and the KF content was fixed at 20 wt%. Based on the degradation temperature investigated by TGA, the thermal stability of PP-g-MAH-SM/KF composites was more enhanced than that of PP-g-MAH only. Mechanical properties of the composites were also improved when MAH and SM applied together. The adhesion degree between the copolymer and KF was confirmed by both SEM pictures of the fractured surface and contact angles.

The Combined Effect of Autologous Fat Injection and Liposculpture for Gluteal Reshaping in Koreans (한국인에 있어 둔부몸매교정(Gluteal Reshaping)을 위한 자가지방주입술 및 지방흡입술의 효과)

  • Kim, Jee-Hoon;Hong, Jin-Joo
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.861-866
    • /
    • 2011
  • Purpose: Together with the breast, buttocks are an important element of attractive body contour. To make a beautiful buttocks, improvement of body contour around the buttock as well as buttock augmentation and lifting is also important. The authors investigated characteristic features of buttocks in Koreans and report about the results of liposculpture and autologous fat injection for improving buttock's contour. Methods: We performed a retrospective study of 21 patients who would like to gluteal reshaping. We checked about buttock's ptosis, projection, depression, gluteal retraction and excessive fat accumulation around buttocks. Depending on it, we performed liposculpture and autologous fat injection. Under general anesthesia, we harvested fat from excessive fat accumulation areas around buttocks, and injected into buttocks medio-superiorly. Postoperatively, pillows were positioned on the bed not to press the buttocks which were injected with the fat. Results: Based on the shape of buttocks, A-shape is seen in 4 cases (19%), V-shape 3 cases (14%), squareshape 9 cases (43%), round-shape 5 cases (24%). Based on the Gonzalez's ptosis grading method, 1 degree ptosis is 1 case (4%), 2 degree ptosis is 6 cases (29%), 3 degree ptosis is 8 cases (38%), 4 degree ptosis is 6 cases (29%). There were no complications such as infection, hematoma, pain, dysparethesia. The subjective assessment of surgical results by patients was excellent. Conclusion: To make a beautiful buttock, improvement of body contour around the buttock as well as buttock augmentation and lifting is also important. Liposculpture and autologous fat grafting are very safe, useful and easy methods for improving buttock's contour.

Synthesis of SAPP-g-(AN/St) Fibrous Ion-Exchanger by E-beam Pre-irradiation and Their Adsorption Properties for Uranium Ion (E-beam 전조사법에 의한 SAPP-g-(AN/St) 섬유상 이온교환체의 합성 및 우라늄 흡착특성)

  • Hwang, Taek-Sung;Park, Jin-Won;Kim, Kwang-Young
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.49-55
    • /
    • 2001
  • The bi-functional ion exchangers, SAPP-g-(AN/St) were synthesized with mixed vinyl monomers(acrylonitrile and styrene) onto PP fabric by the pre-irradiation grafting with E-beam and its subsequent amidoximination and sulfonation. The degree of grafting of PP-g-(AN/St) was increased with decreasing acrylonitrile composition in the mixed monomers. The water uptake of copolymers increased with decreasing in the amidoxime ratio in the copolymers and increased by sulfonation, but decreased by amidoximation. The $UO_2^{2+}$ adsorption capacity of SPP-g-St, APP-g-AN, and SAPP-g-(AN/St) were 12.4, 34.0, and 38.0 mg/g, respectively and the optimum adsorption time is about 50 hrs. As a result of uranium adsorption, the synthesized ion exchanger, which we obtained have also good affinity toward the adsorption or chelating with $UO_2^{2+}$ ions.

  • PDF

Surface Modification and Fibrovascular Ingrowth of Porous Polyethylene Anophthalmic Implants

  • Yang, Hee-Seok;Park, Kwi-Deok;Son, Jun-Sik;Kim, Jae-Jin;Han, Dong-Keun;Park, Byung-Woo;Baek, Se-Hyun
    • Macromolecular Research
    • /
    • v.15 no.3
    • /
    • pp.256-262
    • /
    • 2007
  • The purpose of this study was to determine the effect of surface modification on the fibrovascular ingrowth into porous polyethylene (PE) spheres ($Medpor^{(R)}$), which are used as an anophthalmic socket implant material. To make the inert, hydrophobic PE surface hydrophilic, nonporous PE film and porous PE spheres were subjected to plasma treatment and in situ acrylic acid (AA) grafting followed by the immobilization of arginine-glycine-aspartic acid (RGD) peptide. The surface-modified PE was evaluated by performing surface analyses and tested for fibroblast adhesion and proliferation in vitro. In addition, the porous PE implants were inserted for up to 3 weeks in the abdominal area of rabbits and, after their retrieval, the level of fibrovascular ingrowth within the implants was assessed in vivo. As compared to the unmodified PE control, a significant increase in the hydrophilicity of both the AA-grafted (PE-g-PAA) and RGD-immobilized PE (PE-g-RGD) was observed by the measurement of the water contact angle. The cell adhesion at 72 h was most notable in the PE-g-RGD, followed by the PE-g-PAA and PE control. There was no significant difference between the two modified surfaces. When the cross-sectional area of tissue ingrowth in vivo was evaluated, the area of fibrovascularization was the largest with PE-g-RGD. The results of immunostaining of CD31, which is indicative of the degree of vascularization, showed that the RGD-immobilized surface could elicit more widespread fibrovascularization within the porous PE implants. This work demonstrates that the present surface modifications, viz. hydrophilic AA grafting and RGD peptide immobilization, can be very effective in inducing fibrovascular ingrowth into porous PE implants.

Surface Functionalization of a Fluoropolymer by Ion Beam-induced Graft Polymerization of 4-Vinyl Pyridine

  • Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.341-345
    • /
    • 2010
  • The surface functionalization of a fluoropolymer by ion beam-induced graft polymerization was described in this research. The surface of poly(tetrafluoroethylene) (PTFE) films were irradiated by a 150 keV $H^+$ ions, and 4-vinyl pyridine (4VP) as a functional monomer was then thermally graft polymerized on the irradiated surface. The surface properties of poly(4-vinyl pyridine) (P4VP)-grafted PTFE films were investigated in terms of grafting degree, wettability, chemical structure, and morphology. The results revealed that the surface of PTFE films was successfully functionalized by ion beam-induced graft polymerization of 4VP.

Modification of Styrene-Butadiene-Styrene Block Copolymer and the Properties of Graft Products (스티렌-부타디엔-스티렌 블록 공중합체(共重合體)의 개질(改質)과 그 특성(特性))

  • Wang, Eun-Jin;Yoon, Jeong-Sik;Yoo, Chong-Sun;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.25 no.4
    • /
    • pp.273-279
    • /
    • 1990
  • The graft polymerization of 2-hydroxyethylmethacrylate(HEMA) and vinyltriethoxysilane(VTES) onto styrene-butadiene-styrene block copolymer(SBS) was carried out in toluene, with radical initiator such as benzoyl peroxide(BPO) and 2, 2'-azo-bis-isobutyronitrile(AIBIN) under nitrogen atmosphere. The degree of grafting was increased with the increases of the reaction temperature and time. And the effeciency of BPO was superior to that of AIBN. The mechanical properties and molecular weight of graft products were measured and the applicability as adhesive of plasticized PVC leather was examined.

  • PDF

Evaluation of the Various Artificial Skin Substitutes Implanted onto Nude Mice (누드마우스를 이용한 다양한 피부 대체물의 성능비교)

  • Lee, Won Jai;Lee, Dong Won;Hur, Jae Young;Lee, Young Dae;Park, Beyoung Yun;Rah, Dong Kyun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.127-133
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the remodeling process of the various skin substitutes in 4th and 6th weeks following the transplantation when transplanted onto nude mice. Methods: Three types of artificial skin substitutes, such as PLGA scaffold with keratinocyte sheets(group 1), acellular human dermis($Surederm^{(TM)}$) and keratinocyte sheet(group 2), bioengineered skin($Neoderm^{(TM)}$)(group 3), were applied to the wound on nude mice. All mice were killed in 2, 4 weeks and/or 6 weeks after grafting and tissue samples were harvested from the back of mice. The changes in wound size, degree of angiogenesis, formation of basement membrane and epidermis, density of collagen fibers and neural restoration were examined. Results: There was no significant changes in wound size among the three groups. However, the size of wound decreased in the non-substituted group due to contracture. Degree of angiogenesis and systhesis of collagen or neurofilaments were mostly increased in bioengineered skin($Neoderm^{(TM)}$)(group 3), followed by acellular human dermis($Surederm^{(TM)}$) and keratinocyte sheet(group 2), PLGA scaffold with keratinocyte sheets (group 1). However, group 3 and group 2 showed similar thickness of basement membrane and epidermis. Conclusion: We found that degree of angiogenesis, formation of basement membrane and skin appendages, density of collagen fibers and neurofilaments can be the categories to evaluate the success of artificial skin substitution in early stages.

Open Heart Surgeries in Septuagenarians. (70세이상 환자에서의 개심술)

  • 김형수;이원용;지현근;김응중;홍기우
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1017-1022
    • /
    • 1999
  • Background: An increasing number of elderly are referred for open heart surgeries(OHS). These patients are assumed to have significantly increased morbidity and mortality because of compromised functional reserves in their vital organs. We reviewed the results of OHS patients who were 70 years old or older. Material and Method: Thirty six consecutive septuagenarians underwent OHS from 1995 to 1997. Operations were coronary artery bypass grafting(CABG) in 26 including 3 left main surgical angioplasty, valve replacement in 7, MVR+CABG in 2, and ASD closure+TAP in 1. Statistical tests were carried out to compare survivor group with nonsurvivor group in respect to risk factors including NYHA functional class, LVEF, emergent operation, IABP support, CPB/ACC time, ventilator time cardiac index, ICU stay and hospital stay for operative mortality. Result: Operative mortality rate and postoperative complication were 16%(6/36) and 50%(18/36). One-year and 3-year actuarial survival rates were 76%. Nine patients(25%) had major complications including third-degree A-V block(2), respiratory failure(1), stroke(3), renal failure requiring dialysis(3) and postoperative hemorrhage(2). The causes of death were pneumonia(1), bleeding(1), acute renal failure(1), low cardiac output(1), third-degree A-V block(1), and ventricular tachycardia(1). The univariate analysis of mortality shows that NYHA class IV, LVEF<40%, lesser values for C.I, and longer time for ventilatory support were associated with the risk factors(p value=0.03, 0.001, 0.007, and 0.014). The emergent operation, CPB/ACC time, IABP support, ICU stay and hospital stay were not significant. Conclusion: We conclude that cardiac operation can be performed in septuagenarians with acceptable outcomes when done in patients with normal to moderately depressed left ventricular function and adequate functional reserves in their vital organs.

  • PDF

Polydopamine Coating Behaviors on the Acrylic Acid Grafted-Nanofibers (아크릴산이 그라프트된 나노섬유에서의 폴리도파민 코팅)

  • Shin, Young Min;Kim, Woo-Jin;Park, Jong-Seok;Gwon, Hui-Jeong;Nho, Young-Chang;Lim, Youn-Mook
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.371-376
    • /
    • 2011
  • The surface property of the materials used in tissue engineering application has been essential to regulate cellular behaviors by directing their adhesion on the materials. To modulate surface property of the synthetic biodegradable materials, a variety of surface modification techniques have used to introduced surface functional groups or bioactive molecules, recently polydopamine coating method have been introduce as a facile modification method which can be coated on various materials such as polymers, metals, and ceramics regardless of their surface property. However, there are no reports about the degree of polydopamine coating on the materials with different hydrophilicity. In the present study, we prepared acrylic acid grafted nanofibrous meshes using electron-beam irradiation, and then coated meshes with polydopamine. Polydopamine successfully coated on the all meshes, both properties of acrylic acid and polydopamine were detected on the meshes. In addition, the degree of polydopamine deposition on the materials has been altered according to surface hydrophilicity, which was approximately 8-times greater than those on the non-modified materials. In conclusion, dual effect from the acrylic acid grafting and polydopamine may give a chance as a alternative tool in tissue engineering application.