• Title/Summary/Keyword: gradiometer

Search Result 70, Processing Time 0.025 seconds

Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment (비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발)

  • Kim, In-Seon;Kim, Jin-Mok;Park, Yong-Ki
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

Fabrication of an HTS DC SQUID Electronic Gradiometer and it's application in NDE system (고온 초전도 Electronic Gradiometer의 제작과 NDE system 에의 응용)

  • Kim, Jin-Young;Han, Sung-Gun;Kang, Joon-Hee;Lee, Eun-Hong;Song, I-Hun
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.120-123
    • /
    • 1999
  • We designed and constructed a non-destructive evaluation system using an HTS DC SQUID electronic gradiometer. Our DC SQUID electronic gradiometer is composed of two DC SQUID magnetometers. The system included a non-magnetic stainless steel cryostat and a set of coaxial exciting coils, which were used to induce an eddy current in the test material. We also have calculated the eddy current density produced by an exciting coil in any direction of the testing object. We could compute the eddy current density distribution in 3D. The SQUIDs were computer controlled and the output data from the electronic gradiometer was obtained by using a Labview software.

  • PDF

Design and Construction of an HTS DC SQUID Electronic Gradiometer NDE system

  • Kim, J.Y.;Han, S.G.;Kang, J.H.;Lee, E.H.;Song, I.H.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.115-119
    • /
    • 2000
  • We designed and constructed a non-destructive evaluation system using an HTS DC SQUID electronic gradiometer. Our DC SQUID electronic gradiometer is composed of two DC SQUID magnetometers. The system included a non-magnetic stainless steel cryostat and a set of coaxial exciting coils, which were used to induce an eddy current in the test piece. We also have calculated the eddy current density produced by an exciting coil in any direction of the testing object. We could compute the eddy current density distribution in 3D. The SQUIDs were computer controlled and the output data from the electronic gradiometer was obtained by using a Labview software.

  • PDF

Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer (단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

Characteristics of directly-coupled single -layer second-order high Tc SQUID gradiometer

  • Hwang, Yun-Seok;Moon, Sunk-Yung;Ahn, Jong-Rok;Lee, Soon-Gul;Kim, Jin-Tae
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.184-188
    • /
    • 2000
  • We have fabricated directly-coupled single-layer second-order high-Tc SQUID gradiometer. The gradiometer consisted of 3 parallel-connected square pickup loops, and each loop was directly coupled to SQUID. YBCO thin film was deposited by pulsed laser deposition and patterned by photolithography with ion milling technique. Optimum balancing condition was achieved by varying the outer diameter of the center loop. We have investigated nearly zero response of the SQUID to uniform and 1 st-order field gradient.

  • PDF

Noise Properties of Directly-coupled Single-layer High-Tc 2nd-order SQUID Gradiometer

  • 황윤석;안종록;강찬석;이순걸;김진태
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.163-167
    • /
    • 2002
  • We have fabricated planar-type single-layer second-order high-Tc SQUID gradiometers. The devices consisted of symmetrically designed three parallel-connected square pickup loops that were directly coupled to the SQUID. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ substrate by a PLD system and patterned into a device by the photolithography with ion milling technique. Junctions of the SQUID were either step-edge or bicrystal type. All the structures were formed on a 10 mm $\times$ 5 mm substrate. Balancing of the gradiometer was achieved by adjusting the width of the central pickup loop. The gradiometer noise was measured both inside and outside a magnetically shielded room. Details of the results will be discussed.

  • PDF

Application of Magnetic Methods for finding the Egyptian archaeological features

  • Abdallatif Tareq Fahmy;Suh Mancheol;El-All Esmat Abd
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.157-179
    • /
    • 2004
  • The application of magnetic method for archaeoprospection has been carried out through two archaeological areas in Egypt, Abydos and Abu Sir, In order to find out tile ancient Egyptian archaeological features. The magnetic work at the selected archaeological site of Abydos area was carried out by gradiometer survey, while magnetic work at the selected archaeological site of Abu Sir area was carried out by gradiometer survey and magnetic susceptibility measurements. A gradiometer survey with raster of 0.5 m/0.5 m has been carried out on a surface area of $9600 m^2$ at Abydos area to relocate the buried Solar Boats. The magnetic data were processed using Geoplot software to treat the field noises and enhance the quality of the obtained images. The final magnetic images indicate the existence of 12 Solar Boats as well as tombs, remains of ancient rooms and walls. All of them are expected to belong to the Middle Kingdom, particularly from the 18th to 20th Dynasties. Two magnetic tools have been applied over a selected site of $25600 m^2$ at Abu Sir area in order to detect the hidden archaeological features nearby the Sun Temple. The acquisition of the magnetic data was initiated by the measurements of the topsoil magnetic susceptibility of 272 samples collected from the whole studied area, and then followed by the gradiometer survey to measure tile vertical gradient of the geomagnetic field over an area of $14400 m^2$. The magnetic susceptibility results show the presence of high concentration at the middle part of the study area with a little extension to the south western side, with maximum value of about $36{\times}10^5$ SI. They may indicate the proximity of ritual monuments. Also, they offered the site of interest for carrying out a gradiometer survey. The gradiometer results show tile existence of numerous distributed archaeological features made of mud-bricks with different shapes and sizes. They may indicate tombs, burial rooms, dissected walls; all of them are expected to belong to the 5th Dynasty of pharaohs, who used to build their buildings by mud bricks. The depth of the expected buried archaeological features has been estimated from tihe gradiometer. It is around 1.2m for deep features and 0.42 m for shallow features.