• Title/Summary/Keyword: gradient correlation

Search Result 370, Processing Time 0.041 seconds

The Effect of Cold Shock on Function and Morphology of Dog Epididymal Spermatozoa (개에서 cold shock이 정소상체유래의 정자의 기능과 형태에 미치는 영향)

  • Yu Il-jeoung
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.329-335
    • /
    • 2004
  • Dog spermatozoa were recovered from the caudae epididymides of 23 domestic dogs which were 11 pure breed and 12 mix-breed dogs ranging in age from 0.6 to 3 years. The experimental designs were as follows: 1) the effect of chilling to 0. 10 or 37$^{\circ}C$. 2) the kinetics of chilling injury at 0 or 4$^{\circ}C$, and 3) the effect of sugars at $0^{\circ}C$. Viable spermatozoa were recovered by percoll gradient separation and adjusted to 5${\times}$10$^{7}$ spermatozoa/ml. In experiment 1, spermatozoa were diluted with 0.33 M glucose supplemented with 3% BSA (G-BSA) at 1:2 dilution. Spermatozoa were loaded into straws and exposed at 0, 10 or 37$^{\circ}C$ for 30 min. In experiment 2, spermatozoa were prepared as the experiment 1 and exposed for 0.5, 5, 15, or 30 min at 0 or 4$^{\circ}C$. In experiment 3, spermatozoa were diluted with different sugars (0.33 M galactose, glucose, fructose, mannitol, lactose, sucrose, raffinose) and cooled to $0^{\circ}C$ for 30 min. Sperm membrane integrity, motility and acrosome integrity were assayed after rewarming at 37$^{\circ}C$ for 5 min. Sperm motility and membrane integrity abruptly decreased with decreasing temperature but acrosome integrity gradually decreased (P<0.05). Sperm motility was more sensitive to cold shock than membrane integrity and acrosome integrity. Spermatozoa cooled to $0^{\circ}C$ were more damaged than those at 4$^{\circ}C$. Sperm motility was not different among exposed times at both. 0 and 4$^{\circ}C$. However, membrane integrity of spermatozoa exposed for 30 min at both 0 and 4$^{\circ}C$ was significantly lower (P<0.05). Spermatozoa diluted in 0.33 M fructose or galactose showed lower motility and higher morphological abnormality with coiled tail at $0^{\circ}C$. These sperm characteristics were strongly related. These results indicate that dog epididymal spermatozoa are relatively sensitive to rapid cooling and higher morphological abnormality at $0^{\circ}C$ was shown in spermatozoa diluted in fructose and galactose.

Evaluations of Spectral Analysis of in vitro 2D-COSY and 2D-NOESY on Human Brain Metabolites (인체 뇌 대사물질에서의 In vitro 2D-COSY와 2D-NOESY 스펙트럼 분석 평가)

  • Choe, Bo-Young;Woo, Dong-Cheol;Kim, Sang-Young;Choi, Chi-Bong;Lee, Sung-Im;Kim, Eun-Hee;Hong, Kwan-Soo;Jeon, Young-Ho;Cheong, Chae-Joon;Kim, Sang-Soo;Lim, Hyang-Sook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.8-19
    • /
    • 2008
  • Purpose : To investigate the 3-bond and spatial connectivity of human brain metabolites by scalar coupling and dipolar nuclear Overhauser effect/enhancement (NOE) interaction through 2D- correlation spectroscopy (COSY) and 2D- NOE spectroscopy (NOESY) techniques. Materials and Methods : All 2D experiments were performed on Bruker Avance 500 (11.8 T) with the zshield gradient triple resonance cryoprobe at 298 K. Human brain metabolites were prepared with 10% $D_2O$. Two-dimensional spectra with 2048 data points contains 320 free induction decay (FID) averaging. Repetition delay was 2 sec. The Top Spin 2.0 software was used for post-processing. Total 7 metabolites such as N-acetyl aspartate (NAA), creatine (Cr), choline (Cho), lutamine (Gln), glutamate (Glu), myo-inositol (Ins), and lactate (Lac) were included for major target metabolites. Results : Symmetrical 2D-COSY and 2D-NOESY pectra were successfully acquired: COSY cross peaks were observed in the only 1.0-4.5 ppm, however, NOESY cross peaks were observed in the 1.0-4.5 ppm and 7.9 ppm. From the result of the 2-D COSY data, cross peaks between the methyl protons ($CH_3$(3)) at 1.33 ppm and methine proton (CH(2)) at 4.11 ppm were observed in Lac. Cross peaks between the methylene protons (CH2(3,$H{\alpha}$)) at 2.50ppm and methylene protons ($CH_2$,(3,$H_B$)) at 2.70 ppm were observed in NAA. Cross peaks between the methine proton (CH(5)) at 3.27 ppm and the methine proton (CH(4,6)) at 3.59 ppm, between the methine proton (CH(1,3)) at 3.53 ppm and methine proton (CH(4,6)) at 3.59 ppm, and between the methine proton (CH(1,3)) at 3.53 ppm and methine proton (CH(2)) at 4.05 ppm were observed in Ins. From the result of 2-D NOESY data, cross peaks between the NH proton at 8.00 ppm and methyl protons ($CH_3$) were observed in NAA. Cross peaks between the methyl protons ($CH_3$(3)) at 1.33 ppm and methine proton (CH(2)) at 4.11 ppm were observed in Lac. Cross peaks between the methyl protons (CH3) at 3.03 ppm and methylene protons (CH2) at 3.93 ppm were observed in Cr. Cross peaks between the methylene protons ($CH_2$(3)) at 2.11 ppm and methylene protons ($CH_2$(4)) at 2.35 ppm, and between the methylene protons($CH_2$ (3)) at 2.11 ppm and methine proton (CH(2)) at 3.76 ppm were observed in Glu. Cross peaks between the methylene protons (CH2 (3)) at 2.14 ppm and methine proton (CH(2)) at 3.79 ppm were observed in Gln. Cross peaks between the methine proton (CH(5)) at 3.27 ppm and the methine proton (CH(4,6)) at 3.59 ppm, and between the methine proton (CH(1,3)) at 3.53 ppm and methine proton (CH(2)) at 4.05 ppm were observed in Ins. Conclusion : The present study demonstrated that in vitro 2D-COSY and NOESY represented the 3-bond and spatial connectivity of human brain metabolites by scalar coupling and dipolar NOE interaction. This study could aid in better understanding the interactions between human brain metabolites in vivo 2DCOSY study.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Development and Validation of Analytical Method for Nitroxoline in Chicken Using HPLC-PDA (HPLC-PDA를 이용한 닭고기 중 Nitroxoline 분석법 개발)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Eun;Kim, Jae-Young;Kang, Ilhyun;Lee, Sang-Mok;Do, Jung-Ah;Oh, Jae-Ho;Chang, Moon-Ik;Hong, Jin-Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.1
    • /
    • pp.70-77
    • /
    • 2013
  • BACKGROUND: Nitroxoline is an antibiotic agent. It is used for the treatment of the second bacterial infection by the colibacillosis, salmonellosis and viral disease of the poultry. When the nitroxoline is indiscreetly used, the problem about the abuse of the antibiotics can occur. Therefore, this study presented the residue analytical method of nitroxoline in food for the safety management of animal farming products. METHODS AND RESULTS: A simple, sensitive and specific method for nitroxoline in chicken muscle by high performance liquid chromatograph with PDA was developed. Sample extraction with acetonitrile, purification with SPE cartridge (MCX) were applied, then quantitation by HPLC with C18 column under the gradient condition with 0.1 % tetrabutylammonium hydroxide-phosphoric acid and methanol was performed. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.999, analysed from 0.02 to 0.5 mg/L concentration. Limit of quantitation in chicken muscle showed 0.02 mg/kg, and average recoveries ranged from 72.9 to 88.1 % in chicken muscle. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 12 % in 0.02 and 0.04 mg/kg. CONCLUSION(S): Newly developed method for nitroxoline in chicken muscle was applicable to food inspection with the acceptable level of sensitivity, repeatability and reproducibility.

Enzyme Linked Immunosorbent Assay for the Detection of Antibody to Avian Infectious Bronchitis Virus (효소면역법에 의한 닭 전염성 기관지염 바이러스 항체검사)

  • 송현제;최정옥
    • Korean Journal of Poultry Science
    • /
    • v.18 no.3
    • /
    • pp.183-196
    • /
    • 1991
  • In order to establish ELISA method to detect antibody against IBV various factors involved were examined. Antigen was prepared from Massachusetts type IBV which is known to be one of serotypes distributed most widely. The virus was grown in embryonated SPF chicken eggs. Allantoic fluid harvested was processed to ultracentrifugation and sucrose density gradient centrifugation to produce a purified antigen The antisera selected from the field samples based on hemagglutination inhibition test were used as the standard positive and negative sera for this study and the results obtained were summarized as follows. 1 , It was found that ELISA test was satisfactory when the purified antigen was coated on the plate in the amount of about 40ng protein per well. In case of the phospholipase treated hemagglutinating antigen it gave satisfactory results when the each well wns coated with 1.2 to 2.5 hemagglutinating unit which was equivalent to 40 to 90ng of protein. 2. There was no significant difference in the ratio of optical density of positive to that of negative serum whether the coated antigen was held for 1 hour at 37$^{\circ}C$ or it was held overnight at 4$^{\circ}C$. The coated antigen could be kept in dried state without change of antigenecity for at least one month of experimental period at 4$^{\circ}C$. 3. There was a big variation in the optical density and P/N values depending on the maker of the plates and on the plate of the same maker. 4. It was found that background optical density was negligible when serum was diluted more than 1:50 and serum dilution of 1:100 appeared to be appropriate as a routine test dilution to screen the antibody. 5. Optical density was fairly constant 15 minutes afterward from the time substrate was treated and during the 4 hours after stopper was treated. 6. There was a low correlation(r=0.42) between ELISA and HI test. However, when 74serum samples were tested for the IBV antibody, 98.7% were found to be positive by both tests in which titers of 2$^{6}$ or more by HI test and P/N values of 1.4 or more by ELISA were considered to be positive, 7 Day-old IBV vaccinated chickens shows a similar antibody decay and rising pattern until 8 weeks of age by the two tests, ELISA and HI.

  • PDF

Geochemistry of Total Gaseous Mercury in Nan-Ji-Do, Seoul, Korea (난지도 지역의 대기수은 지화학)

  • Kim, Min-Young;Lee, Gang-Woong;Shin, Jae-Young;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.611-622
    • /
    • 2000
  • To investigate the exchange rates of mercury(Hg) across soil-air boundary, we undertook the measurements of Hg flux using gradient technique from a major waste reclamation site, Nan-Ji-Do. Based on these measurement data, we attempted to provide insights into various aspects of Hg exchange in a strongly polluted soil environment. According to our analysis, the study site turned out to be not only a major emission source area but also a major sink area. When these data were compared on hourly basis over a full day scale, large fluxes of emission and deposition centered on daytime periods relative to nighttime periods. However, when comparison of frequency with which emission or deposition occurs was made, there emerged a very contrasting pattern. While emission was dominant during nighttime periods, deposition was most favored during daytime periods. When similar comparison was made as a function of wind direction, it was noticed that there may be a major Hg source at easterly direction to bring out significant deposition of Hg in the study area. To account for the environmental conditions controlling the vertical direction of Hg exchange, we compared environmental conditions for both the whole data group and those observed from the wind direction of strong deposition events. Results of this analysis indicated that the concentrations of pollutant species varied sensitively enough to reflect the environmental conditions for each direction of exchange. When correlation analysis was applied to our data, results indicated that windspeed and ozone concentrations best reflected changes in the magnitudes of emission/deposition fluxes. The results of factor analysis also indicated the possibility that Hg emission of study area is temperature-driven process, while that of deposition is affected by a mixed effects of various factors including temperature, ozone, and non-methane HCs. If the computed emission rate is extrapolated to the whole study area we estimate that annual emission of Hg from the study area can amount to approximately 6kg.

  • PDF

The Variability of CDOM Along the Salinity Gradients of the Seomjin River Estuary During Dry and Wet Seasons (우기와 건기 중 섬진강 하구역에서 염분경사에 따른 유색용존유기물의 변동성)

  • Lee, Jae Hwan;Park, Mi Ok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.4
    • /
    • pp.362-371
    • /
    • 2016
  • The distribution patterns of Chromophoric Dissolved Organic Matter (CDOM) and the chemical characteristics of CDOM in the Seomjin river estuary were investigated in March, June and July 2012 in order to determine the spatial and temporal variability of CDOM along the salinity gradient considering the effects of mixing, nutrients and Chl a. The average CDOM values were $1.0{\pm}0.3m^{-1}$, $1.3{\pm}0.4m^{-1}$, and $1.4{\pm}0.3m^{-1}$ in March, June and July, respectively. A high concentration of CDOM (greater than $1.5m^{-1}$) was found at the head of the river which decreased towards the river mouth to as low as less than $0.5m^{-1}$. The average concentrations of CDOM increased from the dry season (March and June) to the wet season (July), and the average slope values ($S_{300-500}$), which were used as indicators of CDOM characteristics and sources, were in the range of $0.013-0.018m^{-1}$. The CDOM and $S_{300-50}$ values showed that not only the concentration of CDOM but also the chemical properties of DOM clearly changed between upstream and downstream in the Seomjin river. CDOM and FDOM showed a negative correlation with salinity ($R^2$ > 0.8), and CDOM was positively correlated with FDOM. Furthermore, the mixing pattern of CDOM was confirmed as conservative for all seasons. The main environmental factors influencing the concentration of CDOM was confirmed as conservative for all seasons. The main environmental factors influencing the concentration of CDOM were salinity (mixing) and water temperature, which meant the dilution of low CDOM seawater, was the controlling factor for the spatial distribution of CDOM. Increases in water temperature seemed to induce the production of CDOM during summer (June and July) through the biological degradation of DOM either by microbial activity or photo-degradation.

Identification of Flavonoids from Extracts of Opuntia ficus-indica var. saboten and Content Determination of Marker Components Using HPLC-PDA (손바닥선인장 추출물의 플라보노이드 구조 규명 및 HPLC-PDA를 이용한 지표성분의 함량 분석)

  • Park, Seungbae;Kang, Dong Hyeon;Jin, Changbae;Kim, Hyoung Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.210-219
    • /
    • 2017
  • This study aimed to establish an optimal extraction process and high-performance liquid chromatography (HPLC)-photodiode array (PDA) analytical method for determination of marker compounds, dihydrokaempferol (DHK) and 3-O-methylquercetin (3-MeQ), as a part of materials standardization for the development of health functional foods from stems of Opuntia ficus-indica var. saboten (OFS). The quantitative determination method of marker compounds was optimized by HPLC analysis, and the correlation coefficient for the calibration curve showed very good linearity. The HPLC-PDA method was applied successfully to quantification of marker compounds in OFS after validation of the method in terms of linearity, accuracy, and precision. Ethanolic extracts from stems of O. ficus-indica var. saboten (OFSEs) were evaluated by reflux extraction at 70 and $80^{\circ}C$ with 50, 70, and 80% ethanol for 3, 4, 5, and 6 h. Among OFSEs, OFS70E at $80^{\circ}C$ showed the highest contents of DHK and 3-MeQ of $26.42{\pm}0.65$ and $3.88{\pm}0.29mg/OFS100g$, respectively. Furthermore, OFSEs were determined for their antioxidant activities by measuring 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging and lipid peroxidation (LPO) inhibitory activities in rat liver homogenate. OFS70E at $70^{\circ}C$ showed the most potent antioxidant activities with $IC_{50}$ values of $1.19{\pm}0.11$ and $0.89{\pm}0.09mg/mL$ in the DPPH radical scavenging and LPO inhibitory assays, respectively. To identify active components of OFS, various chromatographic separation of OFS70E led to isolation of 11 flavonoids: dihydrokaempferol, dihydroquercetin, 3-O-methylquercetin, quercetin, isorhamnetin 3-O-glucoside, isorhamnetin 3-O-galactoside, narcissin, kaempferol 7-O-glucoside, quercetin 3-O-galactoside, isorhamnetin, and kaempferol 3-O-rutinoside. The results suggest that standardization of DHK in OFSEs using HPLC-PDA analysis would be an acceptable method for the development of health functional foods.

In Vitro Imaging of MRI and Ultrasound for Gastric Carcinoma (위암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Kil, Sung-Won;Jee, Keum-Nahn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.178-187
    • /
    • 2008
  • Purpose : To evaluate and compare the diagnostic accuracy of MRI and ultrasound(US) for estimation of invasion depth of gastric carcinoma by correlation with histopathologic findings in vitro and to find out the best MR pulse sequence for detection and accurate delineation of tumor. Materials and Methods : Resected specimen of total or subtotal gastrectomy from 53 patients with gastric carcinoma were done of imaging studies of MRI and US. And US was examined by using high frequency linear transducer for tumor invasion depth by a radiologist. In each case, both imaging findings of MRI and US were evaluated independently for tumor detection and invasion depth by consensus of two radiologists and were compared the diagnostic accuracy between two imaging modalities according to the histopathologic findings. MR imaging with five MR pulse sequences, spin echo T1 and in- and out-of phase gradient echo T1 weighted images, FSE and SSFSE T2 weighted images, were performed. Five MR pulse sequences were evaluated and compared on the point of detection and accurate distinction of tumor from surrounding normal tissue. Results : In EGC, diagnostic accuracy of US(77%) was superior than that of MRI(59%) but no statistically significant difference was noted between two imaging modalities(p=0.096). In AGC, both imaging modalities of MRI and US showed relatively high diagnostic accuracy as 97% and 84% respectively. Diagnostic accuracy of MRI was statistically better than that of US at the significant level(p<0.001). The best MR pulse sequence among five in each specimen was FSE T2WI(75.5%, 40/53) in both EGC and AGC. In AGC, FSE T2WI showed excellent imaging quality by showing very high ratio (93.5%, 29/31) of accurate delineation of tumor. Conclusion : MRI and US show relatively high diagnostic accuracy in the evaluation of tumor invasion depth of resected specimen in AGC. The most excellent pulse sequence of MRI for the evaluation of tumor invasion depth is FSE T2WI on the point of detection and accurate delineation of tumor in both EGC and AGC.

  • PDF

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.