• Title/Summary/Keyword: goniometer

Search Result 250, Processing Time 0.028 seconds

3D Map Building of The Mobile Robot Using Structured Light

  • Lee, Oon-Kyu;Kim, Min-Young;Cho, Hyung-Suck;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.123.1-123
    • /
    • 2001
  • For Autonomous navigation of the mobile robots, the robots' capability to recognize 3D environment is necessary. In this paper, an on-line 3D map building method for autonomous mobile robots is proposed. To get range data on the environment, we use an sensor system which is composed of a structured light and a CCD camera based on optimal triangulation. The structured laser is projected as a horizontal strip on the scene. The sensor system can rotate $\pm$ $30{\Circ}$ with a goniometer. Scanning the system, we get the laser strip image for the environments and update planes composing the environment by some image processing steps. From the laser strip on the captured image, we find a center point of each column, and make line segments through blobbing these center poings. Then, the planes of the environments are updated. These steps are done on-line in scanning phase. With the proposed method, we can efficiently get a 3D map about the structured environment.

  • PDF

3D Map Building of the Mobile Robot Using Structured Light

  • Lee, Oon-Kyu;Kim, Min-Young;Cho, Hyung-Suck;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.123.5-123
    • /
    • 2001
  • For autonomous navigation of the mobile robots, the robots' capability to recognize 3D environment is necessary. In this paper, an on-line 3D map building method for autonomous mobile robots is proposed. To get range data on the environment, we use a sensor system which is composed of a structured light and a CCD camera based on optimal triangulation. The structured laser is projected as a horizontal strip on the scene. The sensor system can rotate$\pm$30$^{\circ}$ with a goniometer. Scanning the system, we get the laser strip image for the environments and update planes composing the environment by some image processing steps. From the laser strip on the captured image, we find a center point of each column, and make line segments through blobbing these center points. Then, the planes of the environments are updated. These steps are done on-line in scanning phase. With the proposed method, we can efficiently get a 3D map about the structured environment.

  • PDF

Effects of Foot orthotic on Postrual sway (발보조기가 자세동요에 미치는 효과)

  • Song, Chang-Ho;Lee, Seung-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.99-107
    • /
    • 2004
  • The purpose of this study was to investigate the effect of foot orthotic on postural sway. Subjects were 15 patients(7 men and 8 women) who prescribed foot orthotic at B hospital and L rehabilitation medicine clinic in Seoul. Postural sway during a single limb stance was measured using the CMS 10 Measuring System when subjects positioned on the balance trainer under two treatment conditions(orthotic and nonorthotic). RCSP(resting calcaneal stance position) while subjects were standing on the glass plate was measured using the angle finder after subjects were positioned in prone to divide equally lower leg and calcaneus using the goniometer. The result was as follows. There were significant difference between postural sway of orthotic and nonorthotic conditions(t=4.888, 4.589, p<0.001), and the leg of the small RCSP within a subject has the small postural sway index($x^2=26.000$, p<0.001). In conclusion, foot orthotics provide structural support for detecting and controlling postural sway in patients prescribed foot orthotics.

  • PDF

An Estimation of Comfort on the Automobile Driver Seat Korean Anthropometric Experiment (한국인 인체측정 실험에 의한 자동차 운전석의 안락감 평가)

  • 이영신;이석기;박세진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.61-72
    • /
    • 1996
  • In this paper, the driver seat comfort of eight automobiles was studied. The joint angles and anthropometric data of eleven subjects sitting on the seating buck were investigated using the instrument devices such as scale, goniometer, vernier calipers, protractor, Martin set. The joint angles of the most comfort posture were found by experiment and compared with previous studies. The anthropometric data of Korean(1992 year surveys) and American(1970∼1974 year) were applied to evaluate the driver seat layout of Korean automobile. The joint angles of the most comfort posture for eleven subjects were obtained with experimental results. The joint angles were agreed with reference angles. The driver seat layout was not suited to seat length and acceleratorseatpan forward distance in 5 percentiles female, pedal separation and seatpan-roof height in 95 percentiles male. Korean automobiles were not suited to seatpan length and steering wheelseatpan clearance, floor-roof height for American 95 percentiles male. The driver anthropometric dimensions were more suitable to middle size than small size automobiles.

  • PDF

Evaluation of Endothelial Cell Attachment on Polymer Surface (고분자 표면의 혈관내피세포 부착력에 관한 연구)

  • Choi, Jin-Wook;Ryu, Gyu-Ha;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.131-140
    • /
    • 1990
  • To improve antithrombogenicity of polymer that used in vascular graft and artificial organs, seeding of human endothelial cells on the polyurethane was studied. Human endothelial cells were ismlated from human umbilical veins, using type I collagenase, and identified with goat anti vWF antibodies. Human endothilial cell seeding was tried upon the polyurethane which has good mechanical property and resists stresses. The hydrophobic polyurethane surface was changed hydrophilic by corona discharf:e treatment. Surface hydrophilicity was measured with Wilhemly plate method and the goniometer. To evaluate matrix protein adsorption, fibronectin adsorption test was done. To eveluate cell adhesion, human endothelial cell attachment forces were measured rising a perfusion chamber of , ism diamter. Less cells were detached from the hydrophilically treated polyurethane. This showed that corona discharge on the polyurethane could improve matrix adsorption and endothelial cell attachment.

  • PDF

A Functional Design of Fire Fighter Coveralls (소방용 coverall의 기능적 디자인 연구)

  • Kim, Younghee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.12
    • /
    • pp.1739-1748
    • /
    • 2002
  • 본 연구의 목적은 소방용 coverall의 디자인이 소방수들의 동작기능성에 어떤 영 향을 주는지에 관하여 고찰하여, 보다 기능적 인 coverall을 개발, 궁극적으로 작업자의 노동력을 향상시키고, 보다 안락한 환경 속에서 작업할 수 있도록 도와주는데에 있다. 미국 캔사스 지역의 전문 소방수를 대상으로, interview 및 video analysis를 통하여, 그들이 현재 사용하고 있는 current coverall의 동작기능면에서의 문제점을 조사, 분석한 후, 이를 바탕으로 prototype coverall을 개발하였다 prototype coverall의 동작기능성을 객관적으로 측정하기 위하여 10가지 실험동작(shoulder adduction/ abduction, shoulder flexion/extension, trunk flexion/extension(standing), hip flexion/extension(knee), hip flexion/extension(trunk), upper leg flexion, trunk lateral flexion, hip adduction, trunk flexion/ extension(sitting), upper leg flexion)을 선택하여 이의 관절각도(range-of-motion)를 Leighton flexometer, goniometer, computer-aided method를 이용하여 측정하였으며, 착용자의 주관적 평가를 위하여서는 23 항목의 wearer acceptability scale를 사용하였다. ANOVA(Analysis of Variance)와 LSD(Least Significant Difference)를 이용한 통계처리 결과, prototype coverall이 current coverall에 비해 동작기능성 (특히 crotch, torso, hip movement)에 있어서 우수함을 보이고 있다.

The Knee Joint Position Sense in Healthy Women (정상 성인 여성의 무릎관절 위치감각)

  • Yang, Kyung-Hye;Lee, Hyun-Ok
    • PNF and Movement
    • /
    • v.8 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • Purpose : The purpose of this study is to ascertain whether age, body mass index(BMI) and exercise frequency(EF) are correlated with knee joint position sense in healthy women. Methods : Healthy women of 150 who participated in this study were tested knee joint position sense; each reposition error was analyzed according to the age, BMI and EF. Reposition error was measured with a Myrin goniometer. Results : The age groups, BMI groups and EF groups demonstrated significant differences of the knee joint position sense. The older the healthy women are, the higher BMI is, and the lower EF is, the more decreased knee joint position sense has become. Conclusion : The older the women are, the higher BMI is, and the lower EF is, the more decreased the knee joint position sense in healthy women is. Therefore it needs to be considered to require management of obesity and regular exercise for prevention of knee injuries due to decreased joint position sense.

  • PDF

Development of Quantitative Diagnostic Technique for Low-Back Pain Patients via Three Dimensional Dynamic Motion Analysis (3차원 동작분석에 의한 요통환자의 정량적 진단기법 개발에 관한 연구)

  • Kim, Jeong-Ryong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.11-23
    • /
    • 1998
  • Dynamic motion difference between normal subjects and low-back pain (LBP) patients has been investigated in terms of kinematic variables such as range of motion, velocity and acceleration of the back and hip. Ten healthy subjects and ten LBP patients were recruited in this study. Electro-goniometer such as Lumbar Motion Monitor and Hip Monitor have been used for quantitative measurement of the trunk motion during repetitive flexion and extension for ten seconds. Results indicated that the velocity and acceleration of the back and hip were important parameters to quantitatively identify LBP patients. The consistency of cyclic trunk motion and the relationship between the back and hip were measured in terms of Variance Ratio and Phase Angle in order to accurately assess the motion characteristics of LBP patients. In particular, the hip motion has been proven to be a very important factor in describing the kinematics of damaged lower back. The functional evaluation technique suggested in this study will be a tool to assist physicians for an accurate diagnosis and timely rehabilitation along with current image diagnosis techniques.

  • PDF

A study of measurement on range of arm joint motion of Korean male in twenties (한국인 20대 청년의 팔 관절 동작범위 측정 연구)

  • 이영신;이석기;김철중;박세진
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.39-52
    • /
    • 1996
  • This paper measured the range of arm joint motion for Korean 54 males in twenties. The range of the arm joint motion of the subjects was measured directly using Goniometer and protractor. The number of the static and the dynamic anthropometric variables are seven and thirteen, respectively. The anthropometric data are analyzed by basic statistical analysis (four group), correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach(1978). Thin subjects have larger movement angle as wrist flexion, wrist abduction, elbow flexion, and elbow wupination and have smaller as wrist adduction and shoulder flexion. Fat subjects have larger movement angle as shoulder flexion and are smaller wrist abduction, elbow flexion, pronation, shoulder extension, shoulder adduction, shoulder abduction, and shoulder medial rotation Korean are more flexible than American in wrist and ranges of elbow flexion and elbow rotation. The shoulder movement is similar to that of American, but shoulder flexion is less flexible.

  • PDF

Development of a Modified Exoskeletal Linkage Type Instrument for 3-D Motion Measurement of the Human Knee Joint (무릎관절의 3차원 회전량 측정을 위한 개선된 외골격 링크장치 형태의 측정기구 개발)

  • 김영은;안정호
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.289-294
    • /
    • 1994
  • A new type of electrogoniometer to measure the three dimensional motion of the human knee joint was developed. This instrument is composed of six potentiometers: four arranged for two universal joints, one for pin joint, and one for axial rotation measurement. The voltage change in six potentiometers were collected through A/D converter for acquisition, storage and analysis. With a developed instrument, gait analysis was performed. Compared to earlier developed triaxial type goniometer, new instrument shows its convenience in application and accuracy in measurement.

  • PDF