• Title/Summary/Keyword: goniometer

Search Result 251, Processing Time 0.028 seconds

Concurrent Validity of a Universal Goniometer and a Double Meter Inclinometer for Passive Range of Motion in Beagle Dogs

  • Heo, Su-Young;Park, Yun-Sik;Lee, Hae-Beam
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.241-244
    • /
    • 2017
  • The purpose of this study was to evaluate the concurrent validity of the double meter inclinometer (DMI) for passive joint range of motion (ROM) in beagle dogs and to compare these results to a universal plastic goniometer (UPG). Fifteen beagle dogs were recruited for this study. Joint ROM was evaluated twice with each device to calculate the intraobserver reliability. The intraclass correlation coefficient (ICC) values of the UPG were good to excellent (> 0.75) for all joint ROM tests. Similar results were obtained with the DMI. The ICC values of the DMI were good to excellent (> 0.75) except in extension of the tarsal joint (ICC = 0.69). The majority of the ICC results between each device were poor (< 0.50) with the exception of six joints. Our findings suggest that the inclinometer can be used for passive joint ROM in veterinary medicine. However, caution should be taken when comparing measured values of passive joint ROM obtained utilizing both the DMI and UPG.

Reliability of measurement devices for measuring the ankle joint motion (발목 관절 가동범위 측정을 위한 측정도구의 신뢰도 연구)

  • Hong, Wan-Sung;Kim, Gi-Won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purposes of this study were to establish the concurrent validity of the universal goniometer and electronic inclinometer for ankle joint of motion, and to determine the inter-tester and the intra-tester reliability of these two instruments. Methods: Subjects were instructed 25 healthy subjects. Ankle range of motion was measured on two separate occasions 2 or 3 days by two physical therapists. Ankle dorsiflexion and plantarflexion was by using an universal goniometer and an electronic inclinometer. Results: The Pearson product-moment correlation between the two instruments was 0.78~0.80. The ICCs for inter-tester reliability ranged from 0.63 to 0.73 for universal goniometer and ranged from 0.81 to 0.88 for electric inclinometer. The ICCs for intra-tester reliability showed a wide variation(ICC=0.61 to 0.86). Conclusion: These findings indicate that the two instruments are reliable instruments for measuring ankle joint range of motion. The results also indicate that the two instruments can be used interchangeably for measuring ankle motions.

  • PDF

Usefulness of Smart Phone Application to Measure Cervical Range of Motion (목 관절가동범위 측정을 위한 스마트폰 어플리케이션의 유용성)

  • Chun-Yeop, Lee;Hae-Yoon, Song;Jung-Min, Lee;Moon-Young, Chang
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Objective : The purpose of this study was to estimate the reliability of cervical range of motion measurement in healthy adults using smart phone application and goniometer that can be easily applicated in clinical setting. Methods : The cervical range of motion was measured as the flexion, extension, right rotation, left rotation, right lateral flexion, and left lateral flexion. To measure the reliability of intra-rater and inter-rater reliability, the same examiner performed two measurements and the other examiner performed once, total measurement were performed three times. The order of tests was randomized and two examiners didn't know the results of measurements. Results : Thirty healthy adults were participated. The result of this study shows that there were are no significant differences in all movements except the right lateral flexion in comparison of average angle of smart phone application and goniometer. The intra-rater reliability of smart phone application and goniometer showed ICC as .841~.958 and the inter-rater reliability showed ICC as .720~.944 for all movements. Conclusion : These results suggest that smart phone application and goniometer have proven to be reliable in measuring the cervical range of motion. Smart phone application can be used as a useful tool in clinical setting due to fast and accurate measurements of cervical range of motion.

Comparison of Range-of-motion test methods for measuring Clothing Mobility (의복의 기능성 측정을 위한 관절각도법에 관한 비교연구)

  • Kim, Young-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.12
    • /
    • pp.1374-1380
    • /
    • 2003
  • 본 연구의 목적은 의복의 기능성 측정의 객관적 평가를 위한 관절각도측정의 방법들 간에 상관관계를 분석하고, 컴퓨터를 이용한 측정방법을 개발, 이를 기존의 방법과 비교, 분석함으로써, 의복의 기능성 측정 및 기능적 디자인 개발에 기여함에 있다. 미국 Kansas 지역의 전문 소방수를 대상으로, 선택된 10가지 실험동작에서의 관절각(range-of-motion)을 computer-aided method, Leighton flexometer, goniometer를 사용하여 측정하였으며, 측정순서는 무작위 순서(random order)로 하였다. 독립변인으로는 3종류의 측정방법(computer-aided method, flexometer, goniometer)이며, 종속변인으로는 선택된 동작에서의 관절각(range-of-motion)이다. 또한 상관분석(correlation analysis)을 실시하여, 상관계수(correlation coefficient)를 측정한 통계처리결과, 각 측정방법들 간에 긍정적이며 유의적인 상관관계가 있는 것으로 나타났다.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

Development of Mathematical Model to Predict Dynamic Muscle Force Based on EMG Signal (근전도로부터 동적 근력 산정을 위한 수학적 모델 개발)

  • 한정수;정구연;이태희;안재용
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.315-321
    • /
    • 1999
  • The purpose of this study is to develop a mathematical model for system identification in order to predIct muscle force based on eledromyographic signal. Therefore, a finding of the relalionship between characteristics of electromyographic signal and the corre spondng muscle force should be necessiiry through dynamic, joint model. To develop the dynamic joint model, the upper limb mcludmg the wrist and elbow joint has been considered. The kinematic and dynamic data, such as joint angular displacement, velocity, deceleration along with the moment of inertla, required to establish the dynamic model has been obtained by electrical flexible goniometer which has two degree-of-frcedoms. ln this model, muscle force can be predicted only electromyographs through the relationship between the integrated lorce and the mtegrated electromyographic signal over the duration of muscle contraclion in this study.

  • PDF

Determination of Surface Energy by Means of Home-Made Goniometer and Image Analyzing Software for Contact Angle Measurement (수제 접촉각 측정기와 영상 분석 프로그램을 이용한 표면에너지의 측정)

  • Cho, Seo-Rin;Cho, Han-Gook
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.4
    • /
    • pp.432-438
    • /
    • 2013
  • We report a contact angle goniometer that can be easily assembled and used in high school and general chemistry experiments. It consists of an LED flash, a sample stand, and a camera fixed on an optical bread board, and the sample area is covered to block light from outside with a box with holes on both sides. ImageJ, free image analyzing software and a JAVA plugin (Drop_analysis) were used to determine the contact angle of liquid drop resting on solid surface. The contact angles of various liquids were successfully measured on various surfaces. The solid surface energies have also been determined using the Owen-Wendt method from the contact angles of $H_2O$ and $CH_2I_2$. The results reasonably agree with the previously reported values, showing the surface characteristics and modification as well as the dispersive and polar contributions. These contact angle goniometer and method for determination of the contact angle and surface energy can be applied to observation of various surface properties including wettability, hydrophilicity, and water repelling. Students can learn how the surface properties are related to the intermolecular interactions and gain experience about the equilibrium between the related forces, optics, and mathematical derivations.

Observation Test of Field Surface Reflectance Using Vertical Rotating Goniometer on Tarp Surface and Grass (수직 축 회전형 측각기 제작 및 야외 지표면 반사도 관측 시험: 타프와 잔디에서)

  • Moon, Hyun-Dong;Jo, Euni;Kim, Hyunki;Cho, Yuna;Kim, Bo-Kyeong;Ahn, Ho-Yong;Ryu, Jae-Hyun;Cho, Jaeil
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1207-1217
    • /
    • 2022
  • Vegetation indices using the reflectance of selected wavelength, associating with the monitoring purpose such as identifying the progress of crop growth, on the vegetation canopy surface is widely used in the digital agriculture technology. However, the surface reflectance anisotropy can distort the true value of vegetation index related to the condition of surface, even though the surface property be unchanged. That causes difficulty to observe accurately crop growth on the monitoring system. In this study, a simple type goniometer was designed to measure the reflectance from the anisotropic surface according to various zeniths and azimuths of sun and viewing sensor in the field. On the tarp like as Lambertian surface, the reflectance of Blue, Green, Red, Near-Infrared band was similar to the tarps' reflectance properties. However, the reflectance was slightly overestimated in the cloudy day. The relative difference values of vegetation indices on grass were overestimated for the forward viewing and underestimated for the backward viewing. In addition, enhanced vegetation index (EVI) showed less sensitive according to the positions of sun and sensor viewing. Field observation with a goniometer will be helpful to understand the anisotropy characteristics on the vegetation surface.

Novel Technology for View Angle Performance Measurement

  • Rykowski, Ronald;Lee, Jong-Seo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1358-1361
    • /
    • 2008
  • Several different techniques currently exist for measuring display view angle performance. These include conoscopes, goniometric systems, and, most recently introduced to the market, instruments based on Imaging Sphere technology. This paper will compare measurement accuracy and speed of these various methodologies with different FPD types and even 3-D displays.

  • PDF