• Title/Summary/Keyword: glass-fiber

Search Result 1,694, Processing Time 0.029 seconds

A Case of Giant Cell Interstitial Pneumonia (거대세포 간절성 폐렴(Giant Cell Interstitial Pneumonia) 1예)

  • Kang, Kyeong-Woo;Park, Sang-Joon;Suh, Gee-Young;Han, Joung-Ho;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.;Choi, Jae-Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.260-267
    • /
    • 2000
  • Giant cell interstitial pneumonia. a synonym for hard metal pneumoconiosis, is a unique form of pulmonary fibrosis resulting from an exposure to hard metal dust. A case of biopsy-proved giant cell interstitial pneumonia in the absence of appropriate history of exposure to hard metal dust is reported. The patient presented with clinical features of chronic interstitial lung disease or idiopathic pulmonary fibrosis. He worked in a chemical laboratory at a fertilizer plant, where he had been exposed to various chemicals such as benzene and toluene. He denied having any other hobby in his house or job at work, which may have exposed him hard metal dust. High-resolution CT scan revealed multi-lobar distribution of ground glass opacity with peripheral and basal lung predominance. The retrieved fluid of bronchoalveolar lavage contained asbestos fiber and showed neutrotphil predominance. Surgical lung biopsy was performed for a definite diagnosis. Lung specimen showed alveolar infiltration of numerous multinucleated giant cells with mild interstitial fibrosis. Upon detailed examination of the lung tissue, one asbestos body was found. An analysis for mineral contents in lung tissue was performed. Compared with the control specimen, the amount of cobalt and several hard metal components in the lung tissue of this patient was ten times higher. We speculated that the inconsistency between occupational history and the findings of pathologic and mineralogical analyses could be explained by the difference in individual immunologic reactivity to hard metal dust despite the relatively small amount of unrecognized environmental exposure(ED: It's hard to understand what this phrase is trying to say).

  • PDF

Ground Test & Evaluation of Conformal Load-bearing Antenna Structure for Communication and Navigation (통신 항법용 다중대역 안테나 내장 스킨구조의 지상시험평가)

  • Kim, Min-Sung;Park, Chan-Yik;Cho, Chang-Min;Jun, Seung-Moon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.891-899
    • /
    • 2013
  • This paper suggests a test and evaluation procedure of conformal load-bearing antenna structure(CLAS) for high speed military jet application. A log periodic patch type antenna was designed for multi-band communication and navigation antenna. Carbon/Glass fiber reinforced polymer was used as a structure supporting aerodynamic loads and honeycomb layer was used to improve antenna performance. Multi-layers were stacked and cured in a hot temperature oven. Gain, VSWR and polarization pattern of CLAS were measured using anechoic chamber within 0.15~2.0 GHz frequency range. Tension, shear, fatigue and impact load test were performed to evaluate structural strength of CLAS. Antenna performance test after every structural strength test was conducted to check the effect of structural test to antenna performance. After the application of new test and evaluation procedure to validate a new CLAS, a design improvement was found.

Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio (GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가)

  • You, Young-Jun;Park, Young-Hwan;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.491-497
    • /
    • 2014
  • The corrosion of steel reinforcement in reinforced concrete bridge decks significantly affects the degradation of the capacity. Due to the advantageous characteristics such as high tensile strength and non-corrosive property, fiber reinforced polymer (FRP) has been gathering much interest from designers and engineers for possible usage as a alternative reinforcement for a steel reinforcing bar. However, its application has not been widespread, because there data for short- and long-term performance data of FRP reinforced concrete members are insufficient. In this paper, seven full-scale decks with dimensions of $4000{\times}3000{\times}240mm$ were prepared and tested to failure in the laboratory. The test parameter was the bottom reinforcement ratio in transverse direction. The decks were subjected to various levels of concentrated cyclic load with a contact area of $577{\times}231mm$ to simulate the vehicle loading of DB-24 truck wheel loads acting on the center span of the deck. It was observed that the glass FRP (GFRP) reinforced deck on a restraint girder is strongly effected to the level of the applied load rather than the bottom reinforcement ratio. The study results showed that the maximum load less than 58% of the maximum static load can be applied to the deck to resist a fatigue load of 2 million cycles. The fatigue life of the GFRP decks from this study showed the lower and higher fatigue performance than that of ordinary steel and CFRP rebar reinforced concrete deck. respectively.

Evaluation of Bond Strength in FRP Hybrid Bar Affected by Freezing/thawing Test and UV Rays (동결융해 및 UV 폭로시험을 거친 FRP Hybrid Bar의 인발거동특성 평가)

  • Park, Jae-Sung;Yoon, Yong-Sik;Park, Ki-Tae;Kwon, Sung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • FRP Hybrid Bar, composed of an embedded steel and the coated composites with epoxy and glass fiber, is an effective construction material with tension-hardening performance and lightweight. The epoxy exposed to UV(Ultra Violet Rays) and FT(Freezing and Thawing) action easily shows a surface deterioration, which can cause degradation of bonding strength between inside-steel and outside-concrete. In the present work, surface inspection for 3 different samples of normal steel, FRP Hybrid Bar before UV, and FRP Hybrid Bar after UV test was performed, then concrete samples with 3 reinforcement types were prepared for accelerated FT test. Through visual inspection on 3 typed reinforcement, no significant deterioration like chalking was evaluated. The results from FT test to 120 and 180 cycles showed FRP Hybrid Bar exposed to UV test has higher bonding strength than normal steel by 106.3% due to enlarged bond area by silica coating. The 3 cases showed a similar bond strength tendency with increasing FT cycles, however a relatively big deviations of bond strength were evaluated in FRP Hybrid Bar after UV test due to loss of silica coating.

A Study on Removal of Abietic Acid Using Plasma (플라스마를 이용한 Abietic Acid의 제거에 관한 연구)

  • Kim, Ga-Young;Kim, Da-Seul;Kim, Dong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.788-794
    • /
    • 2020
  • This study was measured and analyzed from January to November 2019 to confirm the effect that Abietic acid, an asthma-causing substance, which can be exposed to workers in the electronics industry, is removed by plasma treatment. The experiment was carried out using a solder wire and natural rosin. Air at temperatures of 250℃, 300℃, and 350℃ was collected with a glass fiber filter paper using an air sampler for 10 minutes at a flow rate of 2ℓ/min. An analysis of the collected samples was performed by pretreatment with methyl alcohol and quantitative analysis by high performance liquid chromatography (HPLC). This procedure confirmed that abietic acid was generated in both natural rosin and solder wires, and the quantum of abietic acid increased as the treatment temperature increased. The amount of abietic acid was higher in natural rosin than solder wire. As a result of plasma treatment, a removal efficiency of about 92% or more was confirmed in natural rosin. A peak of abietic acid was not detected in the solder wire. Therefore, a removal efficiency of 100% was confirmed. This study, confirmed that abietic acid, an asthma-trigger can be generated in solder wire and natural rosin, and can be removed by plasma treatment.

Design of Mach-Scale Blade for LCH Main Rotor Wind Tunnel Test (소형민수헬기 주로터 풍동시험을 위한 마하 스케일 블레이드 설계)

  • Kee, YoungJung;Park, JoongYong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.2
    • /
    • pp.159-166
    • /
    • 2018
  • In this study, the internal structural design, dynamic characteristics and load analyses of the small scaled rotor blade required for LCH(Light Civil Helicopter) main rotor wind tunnel test were carried out. The test is performed to evaluate the aerodynamic performance and noise characteristics of the LCH main rotor system. Therefore, the Mach-scale technique was appled to design the small scaled blade to simulate the equivalent aerodynamic characteristics as the full scale rotor system. It is necessary to increase the rotor speed to maintain the same blade tip speed as the full scale blade. In addition, the blade weight, section stiffness, and natural frequency were scaled according to the Mach-type scaling factor(${\lambda}$). For the design of skin, spar, torsion box, which are the main components of the blade, carbon and glass fiber composite materials were adopted, and composite materials are prepreg types that can be supplied domestically. The KSec2D program was used to evaluate the section stiffness of the blade. Also, structural loads and dynamic characteristics of the Mach scale blade were investigated through the comprehensive rotorcraft analysis program CAMRADII.

Evaluation of Thermal Degradation of CFRP Flexural Strength at Elevated Temperature (온도 상승에 따른 탄소 복합재의 굽힘 강도 저하 평가)

  • Hwang Tae-Kyung;Park Jae-Beom;Lee Sang-Yun;Kim Hyung-Geun;Park Byung-Yeol;Doh Young-Dae
    • Composites Research
    • /
    • v.18 no.2
    • /
    • pp.20-29
    • /
    • 2005
  • To evaluate the flexural deformation and strength of composite motor case above the glass transition temperature$(T_g),\;170^{\circ}C$, of resin material, a finite element analysis(FEA) model in which material non-linearity and progressive failure mode were considered was proposed. The laminated flexural specimens which have the same lay-up and thickness as the composite motor case were tested by 4-point bending test to verify the validity of FEA model. Also. mechanical properties in high temperature were evaluated to obtain the input values for FEA. Because the material properties related to resin material were highly deteriorated in the temperature range beyond $T_g$, the flexural stiffness and strength of laminated flexural specimen in $200^{\circ}C$ were degraded by also $70\%\;and\;80\%$ in comparison with normal temperature results. Above $T_g$, the failure mode was changed from progressive failure mode initiated by matrix cracking at $90^{\circ}$ ply in bottom side and terminated by delamination at the center line of specimen to fiber compressive breakage mode at top side. From stress analysis, the progressive failure mechanism was well verified and the predicted bending stiffness and strength showed a good agreement with the test results.

Indoor Air Concentration of Particulate Matter and Endotoxin in Public Facilities (서울.경기 일부지역 다중이용시설실내공기 중 미세먼지와 미세먼지 중 내독소의 농도)

  • Jeon, Byung-Hak;Hwang, Yu-Kyung;Kim, Hyoung-Ah;Lee, Se-Hoon;Ahn, Kyu-Dong;Heo, Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.4
    • /
    • pp.262-270
    • /
    • 2008
  • This study was conducted to measure concentrations of particulate matter ($PM_{10}$, $PM_{2.5}$) and endotoxin in thirty public facilities (7 elderly-care facilities, 4 hypermarkets, 4 university hospitals, 7 child-care facilities, 4 subway stations and 4 bus terminals) from September 2004 to February 2007 in Seoul and Gyeonggi-do province. $PM_{10}$ or $PM_{2.5}$ was measured with glass fiber filter and mini volume air sampler for 6 to 8 hours in indoor and outdoor of the facilities and expressed as ${\mu}g/m^3$. After weighing the filter, endotoxin was analyzed by Limulus Ameobocyte Lysate method ($EU/m^3$). $PM_{10}$ in indoor air was higher (GM and GSD was 78.00 and $1.92\;{\mu}g/m^3$, respectively) than the outdoor air (GM and GSD was 60.70 and $2.23\;{\mu}g/m^3$, respectively, I/O=1.28). All measurements was not exceeded the national maintenance standard. Elderly-care and child-care facilities showed relatively higher concentrations ($83.27\;{\mu}g/m^3$ and $81.75\;{\mu}g/m^3$; I/O=2.01 and 1.19, respectively) than hypermarkets or university hospitals. The highest PM2.5 was seen in child-care facilities ($62.15\;{\mu}g/m^3$, I/O=2.42). The I/O of the endotoxin in the PM10 and the $PM_{2.5}$ was exceeded 1.0 (1.37 and 1.57, respectively). Indoor $PM_{10}$ was affected by user/day and humidity, and endotoxin in the PM10 was affected by temperature. In conclusion, elderly- and child-care facilities are high priority facilities to be improved indoor air quality.

Reliability and Accuracy of the Deployable Particulate Impact Sampler for Application to Spatial PM2.5 Sampling in Seoul, Korea (서울시 PM2.5 공간 샘플링을 위한 Deployable Particulate Impact Sampler의 성능 검증 연구)

  • Oh, Gyu-Lim;Heo, Jong-Bae;Yi, Seung-Muk;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.277-288
    • /
    • 2017
  • Previous studies of health effects of $PM_{2.5}$ performed spatial monitoring campaigns to assess spatial variability of $PM_{2.5}$ across people's residences. Highly reliable portable and cost-effective samplers will be useful for such campaigns. This study aimed to investigate applicability of the Deployable Particulate Impact Sampler(DPIS), one of the compact impact samplers, to spatial monitoring campaigns of $PM_{2.5}$ in Seoul, Korea. The investigation focused on the consistency of $PM_{2.5}$ concentrations measured by DPISs compared to those by the Low-volume Cyclone sampler (LCS). LCS has operated at a fixed site in the Seoul National University Yeongeon campus, Seoul, Korea since 2003 and provided qualified $PM_{2.5}$ data. $PM_{2.5}$ sampling of DPISs was carried out at the same site from November 17, 2015 through February 3, 2016. $PM_{2.5}$ concentrations were quantified by the gravimetric method. Using a duplicated DPIS, we confirmed the reliability of DPIS by computing relative precision and mean square error-based R squared value ($R^2$). Relative precision was one minus the difference of measurements between two samplers relative to the sum. For accuracy, we compared $PM_{2.5}$ concentrations from four DPISs (DPIS_Tg, DPIS_To, DPIS_Qg, and DPIS_Qo) to those of LCS. Four samplers included two types of collection filters(Teflon, T; quartz, Q) and impaction discs(glass fiber filter, g; pre-oiled porous plastic disc, o). We assessed accuracy using accuracy value which is one minus the difference between DPIS and LCS $PM_{2.5}$ relative to LCS $PM_{2.5}$ in addition to $R^2$. DPIS showed high reliability (average precision=97.28%, $R^2=0.98$). Accuracy was generally high for all DPISs (average accuracy=83.78~88.88%, $R^2=0.89{\sim}0.93$) except for DPIS_Qg (77.35~78.35%, 0.82~0.84). Our results of high accuracy of DPIS compared to LCS suggested that DPIS will help the assessment of people's individual exposure to $PM_{2.5}$ in extensive spatial monitoring campaigns.

Evaluation of Adhesion Property with Pot Life and Curing Humidity of GFRC and Epoxy Adhesive (유리섬유강화 복합재료와 에폭시 접착제의 가사시간과 경화습도에 따른 접착 강도 평가)

  • Yoo, Ji-Hoon;Shin, Pyeong-Su;Kim, Jong-Hyun;Lee, Sang-Il;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.21 no.2
    • /
    • pp.65-70
    • /
    • 2020
  • Epoxy adhesive was mainly used to combine different composite materials. Epoxy adhesive was a typical thermosetting resin that can be bonded by changing from a linear structure to a three-dimensional network structure by curing reaction of epoxy and hardener. The curing conditions of epoxy adhesive were different with different types of hardener such as mixing ratio, curing time, and temperature. These curing conditions affected to the adhesive property of epoxy adhesive. In industry, it was difficult to proceed the applying epoxy adhesive and combining two parts immediately. The adhesive property decreased by humidity and pre-curing of epoxy adhesive in waiting time between two processes. In this paper, the glass fiber reinforced composite (GFRC) was combined with epoxy adhesive and adhesion property between epoxy adhesive and GFRCs was evaluated using single lap shear test. The different waiting times and humidity conditions were applied to epoxy adhesive in room temperature and adhesive property decreased as the waiting time increased. In small amount of humidity, the adhesive property increased because a small amount of moisture in the surroundings accelerated the curing reaction. In certain amount of humidity, however, the adhesion property decreased.