• Title/Summary/Keyword: glass penetration

Search Result 111, Processing Time 0.025 seconds

Fabrication of Low Temperature Cofired Ceramic (LTCC) Chip Couplers for High Frequencies ; II. Effect of Sintering Process on Ag Diffusion (고주파용 저온 동시소성 세라믹(LTCC)칩 커플러 제조: II. Ag 이온 확산에 대한 소결공정의 영향)

  • 이선우;김경훈;심광보;구기덕
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.5
    • /
    • pp.490-496
    • /
    • 1999
  • The sintering behavior of LTCC (low temperature cofired ceramics) chip couplers was investigated in relation with Ag diffusion at the interface of glass ceramic substrate-Ag electrode. Sintering temperature was in the range of 825$^{\circ}C$-975$^{\circ}C$. The commercial green sheet and silver electrode were used. Below 875$^{\circ}C$ the diffusion of the Ag ion into the substrate and the penetration of glassy phases into the electrode occurred due to an increase of fluidity. Thus the lectrode line was severely deformed and damaged. At 975$^{\circ}C$ the transformation of crystalline phases into glassy phases and the melting of the Ag electrode resulted in the diffusion of the considerable amount of Ag ions.

  • PDF

Analysis of Planar Metal Plasmon Waveguides

  • Jung, Jae-Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.97-102
    • /
    • 2010
  • Propagation modes of symmetric metal-insulator-metal SPP waveguides are analyzed. Main characteristics of these waveguides such as mode effective index, propagation length, and penetration depths are calculated at the telecom wavelength for different layer thickness. We adopt Au, Al as a metal material and air, glass as a dielectric material and obtain different optical characteristics. The surface plasmon characteristics in this paper provide a numerical insight for designing nanostructure metal plasmon waveguide.

A STUDY OF THE APICAL LEAKAGE OF VARIOUS RETROGRADE FILLING MATERIALS (Retrograde filling시 수종 충전재료에 따른 폐쇄효과에 대한 연구)

  • Do, Jeong-Wook;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.97-105
    • /
    • 1989
  • This study was conducted to evaluate and compare the apical leakage among the retrograde filling materials; retrograde filling with non-zinc amalgam, cavity varnish and non-zinc amalgam, z.o.e cement, Glass Ionomer cement, scotch bond and silux. Sixty single rooted teeth were divided into six groups and each tooth was individually prepared for its particular group. The specimens were incubated at $37^{\circ}C$ for 24 hrs and then were infiltrated by 2% methylene blue for 7 days. Apical leakage was evaluated by measuring the degree of dye penetration between the filling material and the canal wall. The results were as follows: 1. The scotch bond and silux group showed the least amount of apical leakage and the control group showed the greatest amount of apical leakage. 2. The groups retrofilled with cavity varnish and amalgam, glass-Ionomer cement, scotch bond and silux showed significantly good apical seal than control group. 3. The groups retrofilled with glass Ionomer cement, scotchbond and silux showed significantly good apical seal than the groups retrofilled with Amalgam and Zinc oxide eugenol cement.

  • PDF

Super-giant Magneto-Impedance Effect of a LC-resonator Using a Glass-Coated Amorphous Microwire

  • Lee, Heebok;Kim, Yong-Seok;Yu, Seong-Cho
    • Journal of Magnetics
    • /
    • v.7 no.4
    • /
    • pp.160-164
    • /
    • 2002
  • A new discovery of the super-giant magneto-impedance (SGMI) effect was found out in a LC-resonator consisted of a glass-coated amorphous $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire. The measurement was carried out at high frequency range from 100 MHz up to 1 GHz of an ac-current flowing along the wire and at varying axial dcmagnetic field in its range of $\pm$120 Oe. The wires, about 16${\mu}m$ in diameter, were fabricated by a glass-coated melt spinning technique. The shape of the impedance curves plotted vs. a dc-field is changing dramatically with the frequency. The phase angle was also strongly dependent on this field. The external dc-magnetic field changes the circumferential permeability as well as the penetration depth, both in turn change the impedance of the sample. The drastic increments of SGMI at high frequency can be understood in terms of the LC-resonance phenomena. The sudden change of the phase angle, as large as $180^{\circ}$ evidenced the occurrence of the resonance at a given intensity of the external dc-field. The maximum ratio of SGMI reached in the experiment by precise tuning frequency equals 450,000% at the frequency of around 551.9075 MHz.

IN VITRO STUDY ON THE ADHERENCE AND PENETRATION OF CANDIDA ALBICANS INTO DENTURE SOFT LINING MATERIALS (의치 연성이장재에 대한 Candida albicans의 부착과 침투연구)

  • Kim Min-Ju;Shin Sang-Wan;Lee Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.466-476
    • /
    • 2006
  • Purpose : Colonization of denture soft lining materials by Candida albicans can result in clinical problem, and deterioration of the materials. This study aimed to compare the retention and penetration of C. albicans into four denture soft lining materials commonly used. Materials and methods : Four denture soft lining materials (Coe-comfort$^{(R)}$, Coe-soft$^{(R)}$, GC soft liner$^{(R)}$, and Tissue conditioner$^{(R)}$) discs were prepared to glass slide and dental stone. Adherence of yeast to surfaces was monitored after one hour incubation of standardized washed cell suspension with test disc surfaces. Adherent cells stained with acridine orange were counted fluorescence microscopy. Penetration of yeast into materials bonded with acrylic resin after 1, 2, 3,4, 5, 6 and 7 days incubation was observed through sections stained using acridine orange and estimated to quantitative analysis using radioisotope. Results : There was statistical significance in cell numbers between smooth and rough surfaces(p<0.05). Higher numbers of cells were observed on rough surfaces. There was statistical significance in adherent cell numbers into smooth and rough surfaces individually(p<0.05). According to the increase of incubation periods, the cells penetrated into denture soft lining materials were shown to increase. The differences among all kinds of soft liner were statistically significant(p<0.05),and the largest number of cells penetrated into soft liners was observed in the Coe-soft$^{(R)}$. Conclusion : Initial adherence and penetration of yeast into denture soft lining materials has been influenced by surface roughness and chemical composition of them. The selection of appropriate materials and their fabrication may promote clinical performance.

THE MICROLEAKAGE OF LIGHT-CURED GLASS LONOMER RESTORATIVE MATERIALS IN CLASS V CAVITIES (제 5급와동에서 광중합 그래스 아이오노머 수복물의 미세변연누출에 관한 연구)

  • Cho, In-Sik;Park, Joon-Il;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.304-315
    • /
    • 1998
  • The purpose of this study was to evaluate the microleakage of light cured glass ionomer restorative materials in class 5 cavities. In this in vitro study, class 5 cavities were prepared on buccal and lingual surfaces of forty extracted human premolars and molars on cementum margin. These specimen were randomly divided into four groups of 10 each : Group 1 was Fugi II (control), Group 2 was Fugi II LC, Group 3 was Vitremer, and Group 4 was Dyract. Group 2 was also divided once more into 2 groups of 5 each : Group 2-1 was pretreated with dentin conditioner and Group 2-2 was not. All teeth were restored according to the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 40 teeth were placed in 2 % Methylene blue dye for 24hr, then rinsed with tab water. The specimen were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen were then observed with a stereomicroscope at 20. The results of the study were statistically analyzed using the Student-Newman-Keuls Methods and the Mann-Whitney Rank Sum Test. Tooth restorative interfaces were evaluated using SEM analysis. Results were as follows, 1. Compared to conventional glass ionomer restoratioqs, all light cured glass ionomer restorations were fairly resistant to microleakage (P<0.05). 2. Groups 3 (Vitremer) and Group 4 (Dyract) were found to be the most resistant, Group 2 (Fugi II LC) fairly resistant, and Group 1 (Fugi II) least resistant to microleakage(P<0.05). 3. No significant differences were found between Group 2-1 and Group 2-2 (P>0.08). 4. With the backscattered SEM analysis, the degrees to which tight bonding occurred were also observed in all the groups except for Group 1. Group 4 showed the highest degree of tight bonding than any other materials used in this study.

  • PDF

AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF THE POSTERIOR COMPOSITE RESTORATIONS (구치부 복합레진의 변연누출에 관한 실험적 연구)

  • Kwon, Byeong-Goo;Lee, Chung-Suck;Park, Dong-Soo;Lee, Seung-Jong;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.44-56
    • /
    • 1990
  • This study was designed to assess the degree of the marginal leakage of posterior composite restorations with glass ionomer cement base and Scotchbond$^{(R)}$ by means of the dye penetration at the enamel and dentinal margins. 160 cavities of class V were prepared on the buccal and lingual surfaces of 80 extracted premolar and molar teeth, which were divided into two groups. The buccal cavities of one group were filled with GC lining cement$^{(R)}$, Scotchbond$^{(R)}$ and P 50$^{(R)}$ and the lingual cavities were filled with Scotchbond$^{(R)}$ and Heliomolar$^{(R)}$. The Buccal cavities of other group were filled with Logobond$^{(R)}$, Scotchbond$^{(R)}$ and Heliomolar$^{(R)}$ and lingual cavities were filled with Scotchbond$^{(R)}$ and P 50$^{(R)}$. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$ and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours and buccolingually sectioned with diamond disc. The sectioned specimens were examined under light microscope. The following results were obtained. 1. The group filled with glass ionomer cement base showed less marginal leakage than the group filled without glass ionomer cement base. 2. The enamel margins showed less microleakage than the dentinal margins in both of the two groups. 3. No significant difference was showed in the microleakage, irrespective of two glass ionomer cement base and posterior composite resin.

  • PDF

Kinetic Study Of $La_2$O_3-A1_2O_3-SiO_2$ glass infiltration into Spinel Preforms (스피넬 전성형체의 $La_2$O_3-A1_2O_3-SiO_2$계 유리 침투 kinetic)

  • 이득용;장주웅;김병수;김대준;송요승
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.1
    • /
    • pp.31-35
    • /
    • 2002
  • Abstract Spinel powder having a particle size of 0.9$\mu$m was calcined for 30 min at $1300^{\circ}C$, followed by ball milling for 4h, to obtain the spinel particle size of 3.29$\mu$m. The die-pressed spinel was presintered at $1100^{\circ}C$ for 2h and then lanthanum aluminosilicate glass was infiltrated at $1080^{\circ}C$ for 0~2 h to investigate the penetration kinetics in glass-spinel composite. The infiltration distance is parabolic in time due to capillarity. The strength and the fracture toughness of glassspinel composites were 317 MPa and 3.56 MPa $m^{1/2}$ respectively and dual microstructure of column (needle) and polygonal shapes as a result of recrystallization was observed due to the high calcination temperature.

A STUDY ON MICROLEAKAGE OF LIGHT-CURING GLASS IONOMER CEMENTS (수종 광중합형 글라스 아이오노머 시멘트의 미세누출에 관한 연구)

  • Park, Kwang-Soo;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.721-731
    • /
    • 1995
  • The purpose of this study was to evaluate the adaptability to tooth structure of light-cured glass ionomer cements. In this, study, class V cavities were prepared on the buccal surfaces of thirty extracted human premolar teeth, and they were randomly assigned into 3 groups with 10 teeth. The cavities of each groups were filled with the Fuji II LC(GC International Corp., Japan), Vitremer(3M Dental Products Division, U.S.A) and VariGlass VLC(Caulk/Dentsply Inc., U.S.A.). The specimens were immersed in 1% methylene blue solution and stored in 100% realtive humidity at $37^{\circ}C$ for 5 days. And then, the specimens sectioned buccolingually. Degree of eke penetration at tooth--restoration interfaces were examined by magnifying glass at occlusal and gingival margin. The results were as follows : 1. On the occlusal margin, among the experimental groups, the group 2 showed the lowest microleakage($1.40{\pm}1.17$) and the group 1 showed the highest microleakage($3.10{\pm}0.99$). There was significant difference between group 1 and group 2(P<0.01). 2. On the gingival margin, among the experimental groups, the group 2 showed the lowest microleakage($2.50{\pm}1.08$) and the group 1 showed the highest microleakage($3.50{\pm}0.84$). But there was not significant. difference among the experimental groups(P>0.05). 3. The degree of microleakage at occlusal margin was less than gingival margin in all experimental groups.

  • PDF

A STUDY ON THE APICAL MICROLEAKAGE OF GLASS IONOMER ROOT CANAL SEALER (Glass Ionomer Root Canal Sealer의 치근단 미세누출에 관한 연구)

  • Lee, So-Young;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.236-246
    • /
    • 1998
  • The purpose of this study was to compare the degree of micro- leakage of new glass ionomer root canal sealer, Ketac-Endo(ESPE Co., Seefeld, Germany) with that of AH-26(De Trey Co., Ltd., U.S.A.). Root canal treatment using K -file, H -file, Gate Glidden drill was conducted on 49 extracted single-rooted teeth. 45 teeth were randomly divided into 3 experimental groups(15 teeth per group) and 4 teeth were used as the control group. Group 1 was used AH -26 sealer with the lateral condensation method for canal filling, group 2 was used Ketac-Endo with the single cone method and group 3 was used Ketac-Endo with the lateral condensation method. The control group was obturated with the single cone method without sealer. The teeth were covered with two coats of nail varnish after 48 hours of obturation. The teeth were immersed in India ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows: 1. 7 teeth in group 1, 5 in group 2, and 3 in group 3, were showed evidence of microleakage implying appropriate canal filling. 2, The mean average of microleakage was $0.17{\pm}0.32mm$ in group 1, $0.30{\pm}0.37mm$ in group 2. $0.10{\pm}0.21mm$ in group 3, showing that canal filling using the lateral condensation canal filling method with Ketac-Endo showed the least microleakage and using the single cone method with Ketac-Endo showed the largest amount of microleakage, 3. There were no statistically significant difference in the variation of microleakage among groups. From the results above, Ketac-Endo which has the advantage of glass ionomer, whether using the single cone method or the lateral condensation method, showed similar results as AH-26, but for clinical application it is thought that were studies on the properties of Ketac-Endo should be followed.

  • PDF