• Title/Summary/Keyword: glare evaluation

Search Result 45, Processing Time 0.019 seconds

An Evaluation of Daylight Distribution with Korean Traditional Paper and Roller Shading Systems in the Mock-up model (Mock-up 실험을 통한 전통한지와 차양장치의 주광유입 특성 평가)

  • Lee, Soon-Ji;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.85-88
    • /
    • 2008
  • The purpose of this study is to analyze daylight distribution and light characteristics on the Ma-ji and Roller Shade fabric, and to investigate a possibility of using it as a shading system. Using a 1/2 Mock-up model, daylight distribution is analyzed with the Ma-ji and Sun-ji (Korean traditional paper) which have good efficiency and less glare. Ma-ji has the best daylight distribution, so that daylight experiment is conducted with the Ma-ji and Roller Shade fabric. In current office buildings and apartment houses, daylight characteristics of Korean traditional paper windows could be used as preliminary data to develop a window system which makes better daylight performance.

  • PDF

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

Comparative Analysis on Configurations and Characteristics of IEA's Advanced Daylighting Systems (IEA 첨단채광시스템의 형상 및 특성에 관한 비교분석)

  • Kim, Jeong-Tai;Chung, Yu-Gun;Ahn, Hyun-Tai;Ahn, Hyug-Keun
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • New and innovative technologies for utilizing daylight in buildings have been developed for saving energies and improving visual environments. This study describes the most up-to date information available about the application and evaluation of advanced daylighting systems to enhance daylighting in non-residential buildings from IEA's Task 21. IEA's Task 21 consists on 4 subtasks such as "Performance Evaluation of Daylighting Systems(subtask A)", "Daylighting Responsive Controls(subtask B)", "Daylighting Design Tools(subtask C)" and "Case Studies(subtask D)". For the study, the configurations and characteristics of IEA's advanced daylighting systems are comparatively analyzed. As results, innovative daylighting systems are designed to redirect sunlight or skylight to areas which it is required without glare. These systems use optical devices that initiate reflection or refraction of sunlight and skylight. And they can be designed to actively track the sun or passively control the direction of sunlight and skylight. The comprehensive overview of innovative daylighting systems presented in this study helps designer to understand the advantages of daylighting in building and choose a suitable system for building in the earliest stage of the design process.

Evaluation of the daylight performance of four-sided atria with various well configurations for interior vegitation growth (실내 조경 식물의 생육을 고려한 4면형 아트리움의 형태변수별 자연채광 성능평가)

  • Song, Il-Hak;Kim, Ji-Hyun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.137-143
    • /
    • 2011
  • An atrium space, unlike ordinary office rooms, accommodates variety of activities such as moving and resting of people and usually houses variety of vegitation to improve amenity and indoor environment. Many atrium buildings in Korea have been designed by considering the environmental criteria for human beings, not for the vegitation in the atrium space. Especially the daylighting designs are mostly focused on the required illuminances for various visual tasks of the occupants and glare controls. As a result, some atrium spaces do not provide sufficient light to the interior plants. Consequently, these atrium spaces require a high level of electric lighting to compensate the deficit of natural light for the photosynthesis of the vegitation. The purpose of this study was to suggest design guidelines for 4-sided atrium spaces having different well indices (WI), plan aspect ratio (PAR), and cardinal orientation. The findings from this study might be referenced by building designers when designing or selecting canopy systems by considering the daylight performances of the uncovered atrium spaces. In the study, the daylight performance was evaluated in terms of daylight autonomy (DA).

Performance Evaluation of An Azimuth Tracking Prismatic Daylighting System (방위각 추적식 프리즘형 집광조명시스템 성능평가)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Lee, Eul-Young;Park, Yeon-Min;Joung, Che-Bong;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • This thesis introduced an azimuth tracking prismatic daylighting system. The system improved several issues of the previous passive prismatic daylighting system: low efficiency at sunrise and sunset, glare effect and polarized. The system was developed to track the movement of sun with azimuth tracking device, and it has its own power from the attached solar cells. We compared the with previous passive one in terms with system efficiency and daylighting factors(DF).

Automated Blind Control Strategy to Minimize Occupant's Distractions (재실자 방해 최소화를 위한 자동 블라인드 제어 방안)

  • Koo, So-Young;Yeo, Myoung-Souk;Seong, Yoon-Bok;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.84-92
    • /
    • 2013
  • Blinds are a common type of shading device and are increasingly operated automatically to overcome the limitations of manual operation. Automated blinds need to be controlled to maximize benefits of daylight in the point of occupant comfort and energy consumption. However, the previous control methods could cause occupant's distractions by the undesirable control time interval and amount of blind movement. A few researches suggested the control concept for minimizing occupant's distractions by automatic blind control, but they did not provide optimal control algorithm to be useful in practice. In this paper, we propose an optimal control algorithm for automated blinds that can maximize not only visual comfort but also sunlight penetration into buildings based on occupants' preferences on blind movement and sunlight. The proposed control algorithm can prevent solar glare on workplane and minimize occupant's distractions to maximize occupants' visual comfort.

Experimental Evaluation of the Lighting Environment for Main Activities of the Residents in Living Room (거실 거주자의 주요 행위에 적합한 조명환경 평가 실험)

  • Kim, Hyun-Ji;Woo, Seong Jun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.6-14
    • /
    • 2013
  • The position of the light source, illuminance distribution, and color temperature were evaluated in each lighting environment for the three main activities in a living room - 'watching TV,' 'reading' and 'relaxing.' In 'watching TV', the experiment was done to estimate the degree of comfort felt by the subjects when they watch static video and moving video, respectably, with different ambient brightness, with or without partial lighting above the TV set, and with different color temperatures. In 'reading', the comfortableness was estimated by the illuminance ratio of the ambient lighting to the lighting for reading and by the difference in color temperature. And in 'relaxing', the comfortableness was estimated by means of the ambient brightness, use/no use of a relaxing lamp, and color temperature. This experiment determined the general satisfaction for each visual act and the optimum lighting environment to reduce glare.

DEVELOPMENT OF AN INTEGRATED GRADER FOR APPLES

  • Park, K. H.;Lee, K. J.;Park, D. S.;Y. S. Han
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.513-520
    • /
    • 2000
  • An integrated grader which measures soluble solid content, color and weight of fresh apples was developed by NAMRI. The prototype grader consists of the near infrared spectroscopy and machine vision system. Image processing system and an algorithm to evaluate color were developed to speed up the color evaluation of apples. To avoid the light glare and specular reflection, an half-spherical illumination chamber was designed and fabricated to detect the color images of spherical-shaped apples more precisely. A color revision model based on neural network was developed. Near-infrared(NIR) spectroscopy system using NIR reflectance method developed by Lee et al(1998) of NAMRI was used to evaluate soluble solid content. In order to observe the performance of the grader, tests were conducted on conditions that there are 3 classes in weight sorting, 4 classes in combination of color and soluble solid content, and thus 12 classes in combined sorting. The average accuracy in weight, color and soluble solid content is more than about 90 % with the capacity of 3 fruits per second.

  • PDF

Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method (광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가)

  • Kim, Dong-Su;Yoon, Jong-Ho;Shin, Woo-Chul;Lee, Kwang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind (베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.