• Title/Summary/Keyword: geothermal water

Search Result 338, Processing Time 0.027 seconds

Prediction of Possibility of Indoor Pipe Freezing in Heat Only Boiler Room through Thermal Analysis (열분석을 통한 열전용 보일러동 실내배관의 동파 가능성 예측)

  • Lim, Byoung-Ik;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.19-28
    • /
    • 2012
  • In a heat only boiler system of a steam power plant, outdoor air required for combustion is made to pass through indoor space for increasing the boiler efficiency. Due to heat generated by various equipments, temperature of the air that enters the boiler will increase resulting in combustion efficiency. If the outdoor air temperature is low, however, this will cause freezing and bursting of pipes which are filled with water. It is especially fatal to small diameter pipes and pipes connected to measuring instruments. The purpose of this study is find operation and outdoor conditions where this phenomena can happen and also establish preventive measures to avoid this problem.

Regional Distribution of Ground Thermal Conductivity for Vertical Closed Type Ground Heat Exchanger Design (수직 밀폐형 지중열교환기 설계를 위한 지중 열전도도의 지역별 분포)

  • Jung, Kye-Hoon;Sohn, Byong-Hu;Lim, Hyo-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.423-428
    • /
    • 2007
  • This study was performed to construct a geothermal data base about thermal conductivity of ground heat exchanger and thermal properties of grouting material which used to refill the borehole. We have acquired geothermal data sets from 39 sites over wide area of South Korea except to Jeju island. From data analysis, the range of thermal conductivity is 1.5$\sim$4.0 W/mK. It means that thermal conductivity varies with grouting material as well as regional geology and ground water system.

  • PDF

A Study on the GSHP System for Domestic application(I) (GSHP 시스템의 국내적용성에 관한 연구(I))

  • 백성권;안형준;박영진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.439-444
    • /
    • 2002
  • Geothermal or ground source heat pumps(GSHPs) are electrically powered systems that take advantage of the earth's relatively constant temperature to provide heating, cooling, and hot water for homes and commercial buildings. The buried pipe, or ground loop, is the most recent technical advance in heat pump technology. The idea to bury pipe in the ground to gather heat energy began in the 1940s. Only recently, however, have new heat pump designs and improved buried pipe materials been combined to make GHP systems the most efficient heating and cooling systems available. The aim of the study is application of the GSHP system in korea. Our environments for economy, politics and society are different from other countries. For a case, the progressive tax rate of home electricity is represented.

  • PDF

Optimum Installation Angle of Solar Collectors according to Region and Energy Consumption Patterns (지역 및 에너지소비패턴에 따른 태양열 집열기의 최적설치각 해석)

  • Jun, Yong-Joon;Park, Kyung-Soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.61-67
    • /
    • 2018
  • Solar energy depends on the altitude and azimuth of the sun, and the amount of energy collected on the slope depends on the latitude of the area being installed. However, since most solar heating systems are fixed to the ground, it is necessary to analyze the optimal installation angle from the early design stage. However, problems arise when energy consumption is not considered together because heating systems are not used in the summer In this study, the optimum installation angles of the solar collectors according to the latitude of the installation area are not simply determined by the amount of energy collected, but because the system is overheated due to climate change or energy usage patterns, And the amount of additional energy input.

A Experimental Study on the Application of GRNN for On-Off Control in Floor Radiant Heating System (바닥복사 난방시스템의 개폐식 제어에 대한 GRNN 적용에 관한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.16-23
    • /
    • 2020
  • In this study, the control characteristics and effects of control methods on heating performance and energy consumption for the hot water floor radiant heating control system of a residential apartment were research by experiment. As a control method, On-Off control and outdoor reset control methods with GRNN(General Regression Neural Network) and without GRNN are considered. Also, the control performances with regard to improvement of indoor thermal environment and reduction of energy consumption are compared, respectively. Experiment results show that the performance of the control method with GRNN is better than that of conventional on-off control method without GRNN in the responses of room set temperature and energy saving.

Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System (물-공기 지열 멀티형 열펌프 시스템 실증연구)

  • Kim, Cheol-Woo;Kim, Byoung-Kook;Lee, Pyeong-Gang;Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jong-Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers (Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가)

  • Pang, Seung-Ki;Ahn, Hye-Rin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

The Study of Radon and Uranium Distribution in the Groundwater at Regional Difference of Daejeon (대전지역별 지하수중의 우라늄, 라돈 농도준위 분포조사 연구)

  • Yoon, Yoon-Yeol;Cho, Soo-Young;Lee, Kil-Yong;Kim, Yong-Je
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.1
    • /
    • pp.25-30
    • /
    • 2006
  • To know radon and uranium concentration variations in groundwater with regional difference, groundwaters were sampled at five different Daejeon area. Seventy-five samples were analyzed and forty samples were collected twice at drying and after raining season to know surface water effect. The average radon and uranium concentration of five areas are $270.9{\pm}152.3\;Bq/L,\;43.8{\pm}23.5\;{\mu}g/L$ at Yusung-gu, $112.9{\pm}65.8\;Bq/L,\;0.45{\pm}0.23\;{\mu}g/L$ at Seo-gu, $41.3{\pm}24.0\;Bq/L,\;4.9{\pm}11.3\;{\mu}g/L$ at Dong-gu, $131.8{\pm}99.5\;Bq/L,\;54.3{\pm}127.5\;{\mu}g/L$ at Daeduk-gu and $44.0{\pm}43.0\;Bq/L,\;8.1{\pm}11.6\;{\mu}g/L$ at Jung-gu. The mean concentrations of analyzed samples to know surface water effect were ranged from 0.5 to 640 ${\mu}g/L$ for uranium and from 0.4 to 729 Bq/L for radon. The average concentration of radon and uranium after raining season were lower than those of drying season. The mean contents of radon End Uranium at drying season were $253{\pm}14\;Bq/L,\;63{\pm}12.2\;{\mu}g/L$, and $195{\pm}11\;Bq/L,\;45.4{\pm}11.7\;{\mu}g/L$ after raining season.

Quenching Curves for VOCs in the Analysis of Groundwater $^{14}C$ using Liquid Scintillation Counter (액체섬광계수기를 이용한 지하수의 $^{14}C$ 측정에서 휘발성유기화합물(VOC)에 대한 소광곡선)

  • Lee, Kil-Yong;Cho, Soo-Young;Yoon, Yoon-Yeol;Ko, Kyung-Seok;Kim, Yong-Je
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.53-59
    • /
    • 2007
  • Optimal quenching curves have been studied for the accurate analysis of $^{14}C$ in groundwater polluted by reducing efficiency of volatile organic compounds (VOCs) in liquid scintillation counter (LSC). The quenching parameters (SQP(E)) were measured for ten VOCs such as benzene, toluene, ethylbenzene, o-(m-,p-)xylene, trichloroethylene (TCE), tetrachloroethylene(PCE), carbon tetrachloride and chloroform. The quenching curves were plotted using $^{14}C$ standard solution and chloroform as a quenching agent. Optimal plotting conditions were determined for standard solution, LSC measuring time and the concentration of chloroform. The quenching effects of chlorinated organic compounds such as TCE, PCE, carbon tetrachloride and chloroform were greater than those of BTEX (benzene, toluene, ethylbenzene and xylene). Optimum measuring time was 100 minutes far 7,000 dpm/mL standard solution. A few mL of chloroform should be added for good quenching curves. These quenching curves have good correlation coefficients (> 0.99) and the curves could be applied to accurate analysis of $^{14}C$ in groundwater and tap water.

Evaluation of Water Temperature Difference Energy of the Raw Water from Paldang Water Intake Station (수도권 팔당취수장 원수 이용 온도차에너지 부존량 조사)

  • Cho, Yong;Park, Jin-Hoon;Kim, Youngjoon;Park, Tae Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.170.2-170.2
    • /
    • 2010
  • The amount of the heating and cooling energy of water source heat pump using the raw water from the Paldang water intake station is investigated in the study. The Han river water is conveyed in the large-size shallowly buried pipe. Averaged water temperature at the position, 27 km from the Paldang water intake station, is increased by $1.11^{\circ}C$ due to the geothermal energy transfer under the ground, therefore the raw water has more thermal energy than the river water. To estimate of the thermal energy for the raw water, it is assumed that the water source heat pump is used for the heating and cooling ventilation. When $5.0^{\circ}C$ temperature difference energy of the raw water is used in the heat pump system all the year except for the January and February in which $3.0^{\circ}C$ temperature difference energy is used. It is predicted that total 5,766.3 Tcal could be used in the metropolitan area a year, which is about 3.0% of the river water unutilized energy resources.

  • PDF