• Title/Summary/Keyword: geothermal potential

Search Result 70, Processing Time 0.027 seconds

Performance Analysis of an Earth Tube Heat Exchanger(I) -Temperature Variation Characteristics and Heat Exchange Performance on the Mode of Continuous Operation (지중매설관 열교환장치의 성능분석(I) -연속운전실험에서의 온도특성 및 열교환성능-)

  • Kim, Y.B.;Paek, Y.
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.436-448
    • /
    • 1996
  • An earth tube soil air heat exchange system was designed, installed and operated as a single pass heat exchanger to utilize the geothermal energy as an natural energy source. This study was undertaken to investigate the potential of the heating and cooling, energy gain, heat exchange efficiency and coefficient of performance of the system. The system consisted of 30m in length and 30cm in diameter polyethylene pipes buried 2m deep in soil. Maximum heating and cooling performance were 2.51㎾ and 1.26㎾ at the air mass rate of 21cmm. Energy gain and coefficient of performance were the function of temperature difference between outside air and soil temperature. They were expressed as Q=0.33$ imes$$Delta T_{max}$+0.134(㎾) for energy gain and COP=0.44$ imes$$Delta T_{max}$+0.178 for coefficient of performance with correlation factor of 0.95. The mean of heat exchange efficiencies was 85.6%.

  • PDF

RETScreen(R) Ground Source Heat Pump(GSHP) Application for Korea (RETScreen(R) 지중열 히트펌프 모듈 한국 적용에 관한 연구)

  • Naveed Ahmed T;Park Sanghyun;Lee Euijoon;Kim Byungseon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.678-683
    • /
    • 2005
  • Korea is utilizing geothermal resources mainly in the bathing and swimming facilities with very few applications for industrial processes or space heating. It is estimated that geothermal capacity and annual utilization are 36.2MWt and 761TJ/year as compared to global capacity and annual utilization of 15,145MWt and 190,699 TJ/year. RETScreen software is a user's friendly tool for analyzing the technical and financial pre-feasibility of potential Renewable Energy (RE) projects that promotes the use of RE applications through the capacity building of planners, decision-makers and industries for successful implementation of RE projects. Strong ties between Canada and Korean organizations such as Korean Solar Energy Society (KSES) and the Korea Institute of Energy Research (KIER) exist for knowledge transfer about RETScreen. In this paper, an overview of RETScreen and its ground source heat pump (GSHP) model with a practical example of an existing project of a community hall in Canada are described to illustrate effectiveness of RETScreenin the implementation of RE technologies. The same community hall project is then evaluated hypothetically considering its location at Kangnyng, Korea. The main objective is to demonstrate how RETScreen GSHP model can also be utilized effectively for GSHP applications in Korea.

  • PDF

Study on Heating Performance of Hybrid Heat Pump System Using Geothermal Source and Solar Heat for Protected Horticulture (시설원예용 지열 및 태양열 이용 하이브리드 히트펌프 시스템의 난방성능에 관한 연구)

  • Jeon, Jong Gil;Lee, Dong Geon;Paek, Yee;Kim, Hyung Gweon
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.49-56
    • /
    • 2015
  • In this study a hybrid heating system based on geothermal source and solar heat was developed in order to save energy for greenhouse heating and its field performance was evaluated. Developed system are composed of following parts: water tank, heat exchanger, heat pump, fan coil unit and heat storage unit. The working performance test was carried out in a greenhouse cultivating oriental orchids being managed by $23^{\circ}C$. Field performance test results showed that average heating coefficient of performance ($COP_h$) was 3.4 for the period from mid-January to mid-March 2013. Heating coefficient of performance ($COP_h$) of developed hybrid heat pump system was more sensitive to water tank temperature than outside air temperature. This study showed that developed hybrid heat pump system has a potential to save the heating costs up to 91% compared to conventional agricultural oil heaters.

A Study on the Possibility of Expanding the Use of Green Remodeling for Fire Stations (소방서를 대상으로 한 그린리모델링 용도 확대 가능성 분석에 관한 연구)

  • Sangheon Jeong;Jinhwan Oh;Sangmu Bae;Yujin Nam
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.1
    • /
    • pp.8-15
    • /
    • 2024
  • This study aims to investigate the possibility of expanding the support program for green remodeling of fire stations and analyze the standard design guidelines. Green remodeling is essential for reducing greenhouse gas emissions and promoting green buildings, but currently, it is only conducted for buildings with limited purposes. In this study, we conduct green remodeling for fire stations with severe aging to demonstrate energy performance improvement and investigate the potential for expanding the support program to other types of aging buildings. The research methodology includes analysis of previous studies, preliminary investigation and alternative setting, energy analysis, calculation of construction costs, evaluation of the possibility of introducing support programs, and examine of the fire station standard design guidelines. The research results confirm that green remodeling can reduce energy consumption in fire stations and present the possibility of including fire stations as targets in the support program for green remodeling of public buildings.

Development of Technology on Water Thermal Energy Utilization of Riverbank(including Alluvial and Riverbed deposits) Filtration (강변여과수(충적층 및 하상) 열자원 활용 기술 개발)

  • Kim, Hyoung-Soo;Seo, Min-Woo;Jung, Woo-Sung;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.591-594
    • /
    • 2005
  • Geothermal energy becomes to be one of the promising energy sources. In this study, technology using water thermal energy from riverbank filtration system(including alluvial and riverbed deposit) is reviewed and checked as an energy resources. The objects of this study are (1) long-term monitoring of alluvial and riverbed sites, (2) preliminary design of cooling and heating system at riverbank filtration facility, and (3) calculation of potential groundwater heat energy, including riverbank filtration system. Measuring data of alluvial and riverbank filtration show slight fluctuations comparing to temperature of atmospheric air which indicates that groundwater obtained from the riverbank filtration system have a sufficient potential as a source of cooling and heating energy.

  • PDF

Estimation of deep reservoir temperature of thermal groundwaters in Bugok and Magumsan areas, South Korea

  • Park, Seong-Sook;Yun, Seong-Taek;So, Chil-Sup
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.473-476
    • /
    • 2004
  • In this study, hydrochemical studies of thermal waters in the Bugok and Magumsan areas showing geothermal anomalies were carried, and the applicability of ion seothermometers and multiple mineral equilibrium approach was examined to estimate their potential deep reservoir temperatures. Typical thermal waters of the two areas are clearly grouped into two major types, according to water chemistry: Na-Cl type (group A) and Na-SO4 type (group D). Compared to group A, group B and C waters show some modifications in chemistry. Group E waters show the modified chemistry from group D. Geothermal waters from the two areas showed some different chemical characteristics. The thermal waters of group A and B in Magumsan area are typically neutral to alkaline (pH=6.7 to 8.1) and Cl-rich (up to 446.1 mg/L), while the waters of group D and E in Bugok area are alkaline (pH=7.6 to 10.0) and SO$_4$-rich (up to 188.0 mg/L). The group A (Na-Cl type) and group D (Na-SO$_4$ type) waters correspond to mature or partially immature water, whereas the other types are immature water. The genesis of geothermal waters are considered as follows: group A and B waters were formed by seawater infiltration into reservoir rocks along faults and fracture zones and possibly affected by fossil connate waters in lithologic units through which deep hot waters circulate; on the other hand, group D and E waters were formed by the oxidation of sulfide minerals (mainly pyrite) in surrounding sedimentary rocks and/or hydrothermal veins occurring along restricted fracture channels and were possibly affected by the input and subsequent oxidation of S-bearing gases (e.g. H2S) from deep thermal reservoir (probably, cooling pluton). The application of quartz, Na-K, K-Mg geothermometers to the chemistry of representative group A and D waters yielded a reasonable temperature estimate (99-147$^{\circ}C$ and 90-142$^{\circ}C$) for deep geothermal reservoir. Aqueous liquid-rich fluid inclusions in fracture calcites obtained from drillcores in Bugok area have an average homogenization temperature of 128$^{\circ}C$, which corresponds to the results from ion geothermometers. The multiple mineral equilibrium approach yielded a similar temperature estimate (105-135$^{\circ}C$ and 100-14$0^{\circ}C$). We consider that deep reservoir temperatures of thermal waters in the Magumsan and Bugok areas can be estimated by the chemistry of typical Na-Cl and Na-SO$_4$ type waters and possibly approach 105-135$^{\circ}C$ and 100-14$0^{\circ}C$.

  • PDF

The Greenhouse-Gas Mitigation Potential analysis by Distribution of Solar Thermal System in Housing Sector (태양열난방시스템 도입에 따른 주거부문에서의 온실가스 감축 잠재량 분석)

  • Jeong, Young-Sun;Mun, Sun-Hye;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.32-39
    • /
    • 2012
  • New and renewable energy systems(solar thermal system, photovoltaic system, geothermal system, wind power system) are environmentally friendly technologies and these in South Korea are very important measures to reduce greenhouse-gas(GHG) and to push ahead with Green Growth. The purpose of this paper is to analyze GHG mitigation potential by distribution of solar thermal system in housing sector with bottom-up model called 'Long-range Energy Alternative Planning system'. Business as usual(BAU) was based on energy consumption characteristic with the trend of social-economic prospects and the volume of housing. The total amount of GHG emission of BAU was expected to continuous increase from 66.0 million-ton $CO_{2e}$ in 2007 to 73.1 million-ton $CO_{2e}$ in 2030 because of the increase of energy consumption in housing. The alternative scenario, distribution of solar thermal system in housing sector had GHG mitigation potential 1.54 million-ton $CO_{2e}$ in 2030. The results of this study showed that new and renewable energy systems made a contribution of reducing the use of fossil fuel and the emission of greenhouse-gas in building.

Evaluation of Internal Blast Overpressures in Test Rooms of Elcetric Vehicles Battery with Pressure Relief Vents (압력배출구를 설치한 전동화 차량 배터리 시험실의 내부 폭압 평가)

  • Pang, Seungki;Shin, Jinwon;Jeong, Hyunjin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.7-18
    • /
    • 2022
  • Secondary batteries used in electric vehicles have a potential risk of ignition and explosion. Various safety measures are being taken to prevent these risks. A numerical study was performed using a computational fluid dynamics code on the cases where pressure relief vents that can reduce the blast overpressures of batteries were installed in the through-compression test room, short-circuit drop test room, combustion test room, and immersion test room in facilities rleated to battery used in electric vehicles. This study was conducted using the weight of TNT equivalent to the energy release from the battery, where the the thermal runaway energy was set to 324,000 kJ for the capacity of the lithium-ion battery was 90 kWh and the state of charge (SOC) of the battery of 100%. The explosion energy of TNT (△HTNT) generally has a range of 4,437 to 4,765 kJ/kg, and a value of 4,500 kJ/kg was thus used in this study. The dimensionless explosion efficiency coefficient was defined as 15% assuming the most unfavorable condition, and the TNT equivalent mass was calculated to be 11 kg. The internal explosion generated in a test room shows the very complex propagation behavior of blast waves. The shock wave generated after the explosion creates reflected shock waves on all inner surfaces. If the internally reflected shock waves are not effectively released to the outside, the overpressures inside are increased or maintained due to the continuous reflection and superposition from the inside for a long time. Blast simulations for internal explosion targeting four test rooms with pressure relief vents installed were herein conducted. It was found that that the maximum blast overpressure of 34.69 bar occurred on the rear wall of the immersion test room, and the smallest blast overpressure was calculated to be 3.58 bar on the side wall of the short-circuit drop test room.

Business Model of Renewable Energy Resource Map (신재생에너지 자원지도의 비즈니스 모델 개발)

  • Park, Nyun-Bae;Park, Sang Yong;Choi, Dong Gu;Kim, Hyun-Goo;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.1
    • /
    • pp.39-47
    • /
    • 2016
  • Geographic information system (GIS) based renewable energy resource map including potential analysis can play a crucial role not only to develop the national plan for renewable energy deployment but also to make strategic investment decision in the private sector. Korea Institute of Energy Research (KIER) has been developing domestic maps about several resources such as solar, wind, hydro, biomass, and geothermal, as well as conducting research on methodologies for potential analysis. Furthermore, the institute is trying to transfer related technologies and know-how to foreign countries, recently. In this context, the main purpose of this study is to introduce the business model of renewable energy resource map. From the value chain analysis, we focus on the government-side market in foreign countries, such as the development of the national level renewable energy resource map and the support of the national renewable energy plan. For about 180 countries, we segment the customers according to the consideration of economic capacity, renewable energy resource capacity, existence of renewable resource map, current portion of renewable energy facility capacity, and renewable energy policies, and we conclude that the target customers are non-Organization for Economic Co-operation and Development (non-OECD) countries or some OECD countries, their per capita GDP are under the average among OECD countries, that do not have renewable resource map yet. We segment the target customers into four groups, and suggest different strategies for market positioning and financing strategy based on Strengths, Weaknesses, Opportunities, Threats (SWOT) analysis. This study can help to develop the business strategy about the development of renewable energy resource map in foreign countries.

System Design for Activation of Renewable Energy and Cooperative Renewable Energy Plan Between South and North Korea -Based on the Survey of Renewable Energy Experts- (신.재생에너지 활성화를 위한 제도의 설계와 남북한 신.재생에너지 협력 추진방안 - 전문가 설문에 나타난 신.재생에너지 현황 -)

  • Lim, So-Young;Heo, Eun-Nyeong
    • New & Renewable Energy
    • /
    • v.1 no.3 s.3
    • /
    • pp.24-34
    • /
    • 2005
  • Ministry of Commerce, Industry [MOCIE] has taken it into consideration to introduce a Renewable Portfolio Standard (RPS) that is a purchase obligation program as an alternative plan to the FIT. We conducted a survey of renewable energy companies and experts to ask their opinions about renewable energy policy, the introduction of the RPS, and the scheme for aid of North Korea with renewable energy. Korean renewable energy companies show an impartial opinion about a FIT and a RPS system overall, although they tend to have distinctive opinions by technology each other. With respect to eligible resources for a RPS, the industries want to extend the scope of it as broad as possible. In addition, experts prefer the multi-tiered and energy production based RPS to the sing1e-tiered and installed capacity based RPS. We also conducted a surrey to find the best renewable energy sources. Wind, Geothermal, Solar-thermal, and Photovoltaic were selected to have the best potential capacities to support North Korea by renewable energy experts. However, these energy resources also have several problems to overcome in the aid of North Korea, and thus, the plans for solving them and for giving efficient support to North Korea in the area of Renewable Energy are discussed.

  • PDF