• 제목/요약/키워드: generating performance characteristic

검색결과 56건 처리시간 0.029초

비선형 부하의 증감에 따른 고조파 특성 분석 (Analysis on the Harmonics Characteristics due to increase & decrease of Nonlinear load)

  • 김종겸;이운웅;김일중;김성헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.87-91
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

폐회로 기구학적 구조의 벽면이동 로봇 설계

  • 이정훈;류성무;최혁렬
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.2065-2073
    • /
    • 2000
  • In this paper, we present a wall climbing robot whose gate pattern takes after those of specialized climbing animals such as spiders. Characteristic features of the biological locomotion are partly realized in the design of the mechanism. The robot has two legs and a trunk. Each one-dof leg with suction pads is driven by a motor which employs a closed loop linkage mechanism, and the trunk with suction pads steers the whole body of the robot using a motor. By generating adequate trajectories of the leg and simultaneously alternating the suction pattern between the legs and the trunk, we can achieve the spider like motion. The proposed idea is implemented in a robot and some tests are performed to evaluate its performance.

불평형 전압으로 운전하는 비선형 부하의 고조파 특성 분석 (Analysis on the Harmonic Characteristics of Nonlinear Load Operated by Unbalance Voltage)

  • 김종겸;이은웅;이동주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권10호
    • /
    • pp.491-500
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

농업용 보를 이용한 소수력발전소의 타당성 분석 (Feasibility Assessment of Small Hydro Power Plants Using Diversion Weirs for Agricultural Purpose)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.229-234
    • /
    • 2011
  • Feasibility assessment for small hydropower plants using diversion weirs located in stream for agricultural purpose has been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the inflow caused from rainfall. And another model to predict hydrologic performance for small hydropower plants is established. Preliminary survey was performed identifying several candidate sites, and two sites were selected finally for actual site reconnaissance. During the course of site survey, generating capacity, construction and equipment cost, and payback through life time of each sites were calculated for economical feasibility analysis. The results of this study have estimated that the small hydropower plants using diversion weirs for agricultural purpose may offer better opportunities in future with increasing fuel cost and nation's energy policy.

  • PDF

Design of Simple Controller for Minicar BLDC Motor Based on Low Cost Microprocessor

  • Tao, Yu;Song, Doo-Young;Lei, Zhang;Park, Sung-Jun;Jung, Tae-Uk;Kim, Cheul-U
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.7-9
    • /
    • 2007
  • If used to drive the minicar, the BLDC Motor has advantages of weightless, efficient, small-size and credibleness. In this paper at first the position detecting method for BLDC was introduced, secondly the simulation of control algorithm was done and at last the prototype controller based one chip processor MEGA48 was fabricated. The controller proposed has characteristic of cheap cost, reliable performance and totally meeting demands of minicar control.

  • PDF

불평형 전압 공급시 비선형 부하의 고조파 특성 해석 (Analysis on the Harmonic Characteristics of Nonlinear Load operated by Unbalance Voltage)

  • 김종겸;이은웅;이동주;이화수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.696-698
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

Data Correction For Enhancing Classification Accuracy By Unknown Deep Neural Network Classifiers

  • Kwon, Hyun;Yoon, Hyunsoo;Choi, Daeseon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권9호
    • /
    • pp.3243-3257
    • /
    • 2021
  • Deep neural networks provide excellent performance in pattern recognition, audio classification, and image recognition. It is important that they accurately recognize input data, particularly when they are used in autonomous vehicles or for medical services. In this study, we propose a data correction method for increasing the accuracy of an unknown classifier by modifying the input data without changing the classifier. This method modifies the input data slightly so that the unknown classifier will correctly recognize the input data. It is an ensemble method that has the characteristic of transferability to an unknown classifier by generating corrected data that are correctly recognized by several classifiers that are known in advance. We tested our method using MNIST and CIFAR-10 as experimental data. The experimental results exhibit that the accuracy of the unknown classifier is a 100% correct recognition rate owing to the data correction generated by the proposed method, which minimizes data distortion to maintain the data's recognizability by humans.

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

인덱스 및 증분형 PWM 타입을 이용한 저가형 위치센서에 관한 연구 (The Study on Low-cost Position Sensor Using Index and Increment PWM)

  • 김영수;권순재
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.27-33
    • /
    • 2016
  • BLDC motors have the strong point of allowing high-efficiency operation, yet with the weak point of requiring position information for operation. Moreover, there have recently been frequent cases where the product differentiation of even a cheap BLDC motor demanded a high level of control performance similar to that of a controller using a high-precision position sensor. This paper proposes low cost position sensor that enables the acquisition of rotor position information based on index and incremental PWM, using a single position sensor instead of an expensive incremental encoder or a cheap 3 phase hall sensor. The characteristic of the proposed encoder is that index information at every $60^{\circ}$ of electrical angle is inscribed on the encoder disk, as well as a multiple number of values representing information about PWM, which is obtained by modulating information about the electrical angle of the rotor that has the resolution of $60^{\circ}$. Such a method has the characteristic of enabling the acquisition of high-precision position information based on the information about a multiple number of PWM waveforms and counter values that have all been inscribed on the encoder disk for each $60^{\circ}$ range. The feasibility of the proposed new encoder was verified by fabricating a prototype encoder generating 240 pulses, followed by confirming its performance using Micom's capture and software counter functions.

밸브리스 압전펌프 연동구동 제어기 설계 (Design of Multi-Phase Shift Controller for Valveless PZT Pump)

  • 조정대;박경민;노종호;함영복;유진산
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1282-1285
    • /
    • 2004
  • The high voltage driving system with multi-phase shifter including piezoelectric actuators comprised a driving power unit for outputting the driving power by converting input alternate current into direct current, a frequency shifting unit for supplying the direct current power and shifting or generating a frequency, a high-voltage amplification unit for amplifying the input signal outputted from the driving power unit and the frequency shifting unit into a high-voltage signal, and a phase shifting unit for shifting the phase difference of the amplified signal applied to the high-voltage amplification unit and driving plural piezoelectric actuators sequentially. The results that the operating voltage was stable, the voltage loss ratio was low and the response velocity was fast could be obtained. An experiment on performance of the high voltage driving system with multi-phase shifter designed and manufactured as above described was conducted by using a piezoelectric pump having 3 sheets of round unimorph piezoelectric actuators laminated respectively in a rectangular case. It sucks any fluid by causing the first piezoelectric actuator to shift from the inlet porter side, the phase delay of 60$^{\circ}$ causes the second piezoelectric actuator to begin to shift, and the phase delay of 120$^{\circ}$ causes the third piezoelectric actuator to begin to shift. As a result of measuring each change in the outlet flow rate of the piezoelectric pump, it was shown that the frequency-flow rate characteristic, the voltage-flow characteristic, and the load pressure-flow rate characteristic were improved.

  • PDF